Monitoring Port Activity with Application Software

Similar documents
Table of Contents 1 RMON Configuration 1-1

Table of Contents Chapter 1 RMON Configuration

Contents. RMON commands 1

Operation Manual SNMP-RMON H3C S3610&S5510 Series Ethernet Switches. Table of Contents

802.3 Ethernet Interface YANG Task Force (802.3cf) and RMON MIB (RFC 3635) (Also Power over Ethernet YANG)

Contents. RMON commands 1

802.3 Ethernet Interface YANG Task Force (802.3cf) and RMON MIB (RFC 3635)

Remote Monitoring MIB

802.3 Ethernet Interface YANG Task Force (802.3cf) and RMON MIB (RFC 3635) (Also Power over Ethernet YANG)

Appendix A Remote Network Monitoring

Out-of-Band Management

Configuring and Monitoring from the Hub Manager

VERTICAL HORIZON VH-2402S FAST ETHERNET SWITCH MANAGEMENT GUIDE

Configuring the Catalyst 3920

Chapter. Managed Switch Software Monitoring. In This Chapter...

Overview. About the Catalyst 2820 and Catalyst 1900 Switches CHAPTER

Overview. Switch Features CHAPTER

RMON Commands. Cisco IOS Configuration Fundamentals Command Reference FR

STD: 59 May 2000 Obsoletes: 1757 Category: Standards Track. Remote Network Monitoring Management Information Base

Introduction to the Catalyst 3920

RMON on the Workgroup Catalyst Series

RMON Configuration Guide, Cisco IOS Release 12.4

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

10/100 MANAGED HUB. Network Management Guide JUNE 1999 LH8112A LH8124A

Managing Your Switches

Token Ring VLANs and Related Protocols

Software Update C.09.xx Release Notes for the HP Procurve Switches 1600M, 2400M, 2424M, 4000M, and 8000M

GEL Port Web Smart Gigabit Switch GEP Port Web Smart Gigabit PoE Switch. CLI Reference Guide V1.0

Radiance Gigabit Ethernet Services Line Card

Configuring RMON. Understanding RMON CHAPTER

Token Ring VLANs and Related Protocols

Troubleshooting the Network Analysis Module. Netflow Data Export. Web Application CHAPTER

Getting Started with the VG248

Configuring Port Security

Cajun P220FE Switch Software Release Notes

MR2324-4C. 24-Port Intelligent Gigabit Ethernet Switch. Management Guide

Configuring IP Addressing

Using the HP Web Browser Interface

Powered by Accton. ES Port Gigabit Web-Smart Switch. Management Guide.

Configuring Interface Characteristics

CCNA Practice Questions Exam Cram 2. Copyright 2004 by Que Publishing. International Standard Book Number: Warning and Disclaimer

Tracking Packet Flow Using Path Analysis

Configuring the System

Configuring the Cisco NAM 2220 Appliance

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20

RMON MIB. Presenter: Andreas Pitsillides. Based on presentation by Rouf Boutaba

VOL Volition Managed Ethernet Switch. User Guide. Innovation

Configuring Port-Based Traffic Control

EtherChannel, Neighbor View, and Trap Receiver Table

25-Port Fast Ethernet Switch

MR2228-S2C. Stack Fast Ethernet Switch Management Guide

Chapter 2. Switch Concepts and Configuration. Part I

Configuring Interfaces and Circuits

Configuring SPAN and RSPAN

The following steps should be used when configuring a VLAN on the EdgeXOS platform:

24-Port Fast + 2-Port Giga Intelligent Ethernet Switch SG9224B WEB USER GUIDE. Date: 02, Standard Version. Version: 1.02

Cisco Small Business SF200E Series Advanced Smart Switches

Clustering Switches. Understanding Switch Clusters CHAPTER

Switch configuration. By the end of this session, you will be able to: Describe basic switch configuration methods. Configure a switch.

Monitoring Policies Reference

CG-MSW2402TXR CG-MSW1601TXR コマンドリファレンス

Configuring SPAN and RSPAN

Cisco Discovery Protocol Version 2

16-SLOT IN-BAND MANAGEMENT CHASSIS

Configuring InterVLAN Routing

Configuring and Monitoring from the Switch Manager

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

AT-S41 Version 1.1.7C Management Software for the AT-8326GB and AT-8350GB Series Fast Ethernet Switches. Software Release Notes

802.1w Rapid Spanning Tree Protocol (RSTP) 802.1d Spanning Tree Protocol (STP)

Section 1. General Networking Theory

Chapter 4 Configuring Switching

Tracking Packet Flow Using Path Analysis

Using the Command-Line Interface

CCNA Practice test. 2. Which protocol can cause high CPU usage? A. NTP B. WCCP C. Telnet D. SNMP Answer: D

Configuring Port-Based Traffic Control

Selecting a Management Interface

Configuring Port-Based Traffic Control

Ethernet Switch ZyNOS 4.0

Part No , Rev. A June OmniStack Users Guide

Interconnecting Cisco Networking Devices

Configuring IEEE 802.3ad Link Bundling and Load Balancing

Configuring SNMP. Understanding SNMP CHAPTER

8-Port Fast Ethernet Switch

Configuring SPAN and RSPAN

Using Cisco IOS Software

Ethernet Operation G-Series Application CHAPTER

Performance Monitoring

Troubleshooting. Diagnosing Problems. Verify Switch Module POST Results. Verify Switch Module LEDs CHAPTER

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

Initial Configuration

Layer 2 Ethernet Switch Allied Telesyn AT-8000S

Implement VTP. LAN Switching and Wireless Chapter 4 Modified by Tony Chen 10/01/2008

Configuring Interface Characteristics

Managing Switches. Finding More Information About IOS Commands CHAPTER

Configuring VTP. Understanding How VTP Version 1 and Version 2 Work CHAPTER

Cajun P550/P880 Manger User Guide

HP 6125 Blade Switch Series

Upon completion of this chapter, you will be able to perform the following tasks: Identify what a VLAN is and how it operates. Configure a VLAN to

Configure Controller and AP Settings

Vendor: Cisco. Exam Code: Exam Name: Cisco Interconnecting Cisco Networking Devices Part 1 (ICND1 v3.0) Version: Demo

Transcription:

CHAPTER 9 Monitoring Port Activity with Application Software This chapter explains how to monitor a port on the Catalyst 3200 using: Network Management System (NMS) using CiscoView or any application that supports Simple Network Management Protocol (SNMP). The topics discussed are: SNMP Set-up IP Configuration SNMP Configuration SwitchProbe Analyzer port (SPAN) and RMON applications. The topics discussed are: Uses of the SwitchProbe Analyzer Port (SPAN) Selecting the Port to Analyze Using an RMON Application Monitoring Port Activity with Application Software 9-1

SNMP Set-up SNMP Set-up Follow these steps to use in-band management: Step 1 Step 2 Step 3 Attach the Catalyst 3200 to the console and start a console session as described in Chapter 6, Connecting a Network Management Console. Complete the IP Configuration menu. Complete the SNMP Configuration menu and following sub-menus: Community String menu. Trap Receiver menu. The following sections describe the SNMP set-up menus. IP Configuration The IP Configuration menu sets the IP address, gateway address, subnet mask, and IP state. The IP Address and Default Gateway must be in the same subnet address class that is, Class A, Class B, or Class C. The system prevents you from entering values from different classes. If you do inadvertently enter an incorrect value, enter 0.0.0.0 in every field, then re-enter the correct values. Refer to Chapter 7, Console Configuration, for a complete description on how to configure the IP Configuration menu. 9-2 Catalyst 3200 Installation and Configuration Guide

SNMP Configuration SNMP Configuration Use the SNMP Configuration Menu to configure specific attributes related to SNMP. SNMP Configuration Screen SNMP Configuration Return to Previous Menu Send Authentication Traps Community Strings... Trap Receivers... Yes Display the Configuration Menu Use cursor keys to choose item. Press <RETURN> to confirm choice. Press <CTRL><P> to return to Main Menu. H4660 Monitoring Port Activity with Application Software 9-3

SNMP Configuration Send Authentication Traps Indicates whether SNMP should issue an authentication trap to Trap Receivers whenever an unauthorized request is detected. Default: Yes Community String Menu Changes the community string table. The community string is the name associated with the Catalyst 3000 and a set of SNMP Managers. Entries in the table are saved across resets and power cycles. Trap Receiver Menu Displays table of managers to which traps are sent. Entries in the table are saved across resets and power cycles. 9-4 Catalyst 3200 Installation and Configuration Guide

SNMP Configuration Community String Menu Use the Community String menu to configure the community string for the Catalyst 3200. The community string is the name associated with the Catalyst 3200 and a set of SNMP managers allowed to manage it with the specified privilege level. Note Text within the community string is Upper/Lower case sensitive. Entries are displayed in the order in which they are encountered. There is a limit of 10 community strings. Community String Table entries are saved when you select Return to Previous Menu. Entries are preserved across resets and power cycles. Monitoring Port Activity with Application Software 9-5

SNMP Configuration Index Sequential number of entries in the table. Community Name The specified privilege level of the assigned community. Mode Specific access privileges of the community. Read Read/Write Add Entry Adds community string. Delete Entry Deletes community string. Change Entry Modifies community string and/or access mode. Clear Table Deletes all community strings. 9-6 Catalyst 3200 Installation and Configuration Guide

SNMP Configuration Trap Receiver Menu Trap Receiver Tables tell the Catalyst 3200 where to send traps. The table contains the IP address associated with an SNMP manager. Trap Receivers IP Address 1 192.9.200.1 2 192.9.200.2 Community Name public private VLAN default Return More Add Entry Delete Entry Change Entry Clear Table Return to previous menu Use cursor keys to select action. Press <RETURN> to confirm choice. Press <CTRL><P> to return to Main Menu. Zoom H4658 The Trap Receiver Table contains a maximum of 20 entries. It is displayed again each time the table changes. Each VLAN requires a separate entry. Trap Receiver Table entries are saved when you select Return to Previous Menu. Entries are preserved across resets and power cycles. Monitoring Port Activity with Application Software 9-7

SNMP Configuration IP Address The IP address associated with an SNMP manager. Community String The specified privilege level. VLAN Specifies a list of VLANs in which the trap is sent out. More To view next page of table. Add Entry Adds a new entry to the trap receiver table. Delete Entry Deletes an entry from the trap receiver table. Change Entry Modifies an entry in the trap receiver table. Clear Table Deletes all table entries. Zoom To display a Trap receiver entry in detail. 9-8 Catalyst 3200 Installation and Configuration Guide

Uses of the SwitchProbe Analyzer Port (SPAN) Uses of the SwitchProbe Analyzer Port (SPAN) The SPAN port, located on the front panel of the Catalyst 3200 Supervisor Engine, connects to probe devices such as protocol analyzers, RMON probes, and other Ethernet-compliant devices. This enables you to decode packet contents for troubleshooting or to analyze network characteristics. Using the SPAN port, you can monitor any one of the 10BaseT ports on the Catalyst 3200. The SPAN port can not monitor the high-speed expansion module ports. The SPAN port is used for monitoring only; it cannot be used to transmit data. Therefore, monitoring the Catalyst 3200 with an RMON probe requires the use of two ports: one to listen through the SPAN port and one to communicate with the SNMP station. To monitor several Catalyst 3200 devices using a single monitoring device, connect each SPAN port to a hub, then connect the monitoring device to the hub. Do not connect any ports other than SPAN ports. Only one SPAN port may be active at once; disable all other SPAN ports by entering 0 in the SwitchProbe Port field of the SwitchProbe Configuration menu (see the section, Selecting the Port to Analyze, later in this chapter). When traffic at a port that is being monitored by the SwitchProbe is very heavy (above 80 to 90%), the SwitchProbe (not the port) may drop some packets. Selecting the Port to Analyze You can select which port you want to analyze using either the network management console connected to the EIA RS-232 console port of the Catalyst 3200, or using an SNMP network management application such as the Cisco SwitchVision application or a Telnet session. Monitoring Port Activity with Application Software 9-9

Uses of the SwitchProbe Analyzer Port (SPAN) SwitchProbe Configuration Screen Follow these steps to select the port to analyze: Step 1 From the Main menu, select the Configuration menu, then select the SwitchProbe (Configuration) menu. The following screen appears: SwitchProbe Configuration SwitchProbe Port Numbers Traffic to Probe 0 None Display the Main Menu Use cursor keys to choose item. Press <RETURN> to confirm choice. Press <CTRL><P> to return to Main Menu. H4794 9-10 Catalyst 3200 Installation and Configuration Guide

Uses of the SwitchProbe Analyzer Port (SPAN) Step 2 Step 3 Step 4 Complete the field for the port number on the screen as follows: SwitchProbe Port Number Use the arrow keys to highlight the SwitchProbe Port Number field and press RETURN. At the New Value: prompt, enter the number of the port you want to monitor (be sure the Monitor Link is enabled [up] on that port) or enter zero to disable the SwitchProbe function on the port. Traffic to Probe The type of traffic that will be monitored. If the selected port is set for Half-Duplex communication, both Receive and Transmit traffic is monitored. If the selected port is set for Full-Duplex communication, you can monitor either Receive or Transmit traffic. To toggle between Receive or Transmit, select the field and press RETURN. Select Return to Previous Menu to accept the new settings. Begin monitoring port traffic using the probe equipment. Note If you change the duplex mode of a port that is being monitored by the SwitchProbe Port, traffic on that port will no longer be seen by the SwitchProbe Port. You must reenter this menu and reconfigure the SwitchProbe Port to that port. Monitoring Port Activity with Application Software 9-11

Using an RMON Application Using an RMON Application Use the RMON Configuration Menu to establish communications with an RMON application. Starting RMON Use the following steps to start, stop, or configure an RMON application: Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Go to the Configuration menu and select RMON Configuration. From the RMON Configuration menu, highlight Enable RMON and press RETURN. At the prompt, select Yes or No. Whether you enable or disable RMON, you must reboot before the new state takes effect. If you are going to do any SNMP configurations (Step 4), you can reboot after the configurations are complete. To add the community string, go to the Configuration menu and select the SNMP Configuration menu. From the SNMP Configuration menu, select the Community Strings menu. At the Community Strings menu: Add the Read/Write community string that the RMON manager (such as Traffic Director) will use. Return to the Configuration/SNMP Configuration menus to configure any Trap Receivers. Select the Trap Receivers menu at the SNMP Configuration menu. At the Trap Receivers menu: Add the RMON manager as a trap receiver so that the RMON agent can generate alarms to the RMON manager. 9-12 Catalyst 3200 Installation and Configuration Guide

Using an RMON Application RMON Groups Supported Ethernet Statistics (see the section on RMON Ethernet Statistics Counters). History Events Alarms RMON Requirements The following lists the RMON requirements for a single Catalyst switch and a Stack of switches. Stand alone Switch A single switch can run with 4MB of memory with some restrictions. Do not increase the number of history buckets beyond 50. The number of VLANS (in the VTP VLAN Configuration) should be no more than 100. Interface numbers 1-28 in Table 9-1. Stacked Switches The IP Controller switch (lowest number box in the Stack) must have 8MB of memory to run RMON on the Stack. Full configuration of all features is allowed. It is recommend that switches with only 4MB not be used is a Stack. Otherwise, many restrictions apply. If the IP Controller switch has only 4MB, RMON statistics can be gathered only on that box. The number of VLANS (in the VTP VLAN Configuration) should be no more than 64, with ports assigned to no more than 14 VLANs. Do not increase the number of history buckets beyond 50. ISL trunks should not be installed in the IP Controller box. Interface numbers 1-252. The interface numbers assigned to ports are listed in Table 9-1. They can also be calculated according to the following formula: interface_number = (box_number - 1) * 32 + port_number Monitoring Port Activity with Application Software 9-13

Using an RMON Application Table 9-1 Interface Numbers For Stack Ports Port # Box 1 Box 2 Box 3 Box 4 Box 5 Box 6 Box 7 Box 8 1 1 33 65 97 129 161 193 225 2 2 34 66 98 130 162 194 226 3 3 35 67 99 131 163 195 227 4 4 36 68 100 132 164 196 228 5 5 37 69 101 133 165 197 229 6 6 38 70 102 134 166 198 230 7 7 39 71 103 135 167 199 231 8 8 40 72 104 136 168 200 232 9 9 41 73 105 137 169 201 233 10 10 42 74 106 138 170 202 234 11 11 43 75 107 139 171 203 235 12 12 44 76 108 140 172 204 236 13 13 45 77 109 141 173 205 237 14 14 46 78 110 142 174 206 238 15 15 47 79 111 143 175 207 239 16 16 48 80 112 144 176 208 240 17 17 49 81 113 145 177 209 241 18 18 50 82 114 146 178 210 242 19 19 51 83 115 147 179 211 243 20 20 52 84 116 148 180 212 244 21 21 53 85 117 149 181 213 245 22 22 54 86 118 150 182 214 246 23 23 55 87 119 151 183 215 247 24 24 56 88 120 152 184 216 248 25 25 57 89 121 153 185 217 249 26 26 58 90 122 154 186 218 250 27 27 59 91 123 155 187 219 251 28 28 60 92 124 156 188 220 252 9-14 Catalyst 3200 Installation and Configuration Guide

Using an RMON Application Notes for Using TrafficDirector These notes also apply to other RMON managers. 1 When setting up an agent on a Stack port, change the timeout from the default of 5 to at least 15 seconds. Retries may be left at the default value. This will prevent TrafficDirector from thinking the agent is not responding during Stack updates or address aging. 2 No RMON agent settings are saved by the switch. If a switch is rebooted, agents will need to be reinstalled by TrafficDirector. 3 If the IP Controller box is removed from the Stack, the agents will need to be reinstalled by TrafficDirector. 4 If a new box that is already running is added to a working Stack, but has a different enable/disable state setting for RMON, reboot the Stack. Otherwise, change the RMON state to the one that matches the working Stack, reboot the box, then add it to the Stack. 5 If a box leaves and then rejoins a Stack, all agents on that box must be reinstalled by TrafficDirector. RMON Ethernet Statistics Counters The following sections list the Statistics anomalies and the following table, Table 9-2, contains RMON Statistics definition differences. Port counter resets When the packet count (etherstatspkts) wraps around at 4,294,967,295, the agent will think that the port s statistics have been cleared and will reset all the etherstats counters. If a network segment averages 5,000 pkts/sec, this counter will wrap around every 10 days. Differences from RMON counter definitions. The ISL ports have hardware support for accurate RMON counters, with one exception, etherstatsoversizepkts on ISL trunk ports. However, the other port types do not have special RMON counters, so the information may not be exactly according to the RMON counter definitions. Differences in the RMON definitions are listed in Table 9-2. Monitoring Port Activity with Application Software 9-15

Using an RMON Application Table 9-2 RMON Definition Differences Statistic Name Definition Differences etherstatsdropevents Total number of packets dropped by the monitor due to lack of resources. This is not necessarily the number of packets dropped, just the number of times this condition has been detected. For all ports, packets lost between the LMA and CPU buffers will not be counted. This can only happen under a long sustained, extremely heavy load of packets directed to the CPU. etherstatsoctets etherstatspkts etherstatsbroadcastpkts etherstatsmulticastpkts etherstatscrcalignerrors etherstatsundersizepkts Total number of octets (including those in bad packets) received on the network. This excludes framing bits but includes Frame Check Sum (FCS) octets. Total number of packets received, including multicast, broadcast, and bad packets. Total number of good packets received directed to the broadcast address. This does not include Multicast packets. Total number of good packets that are received directed to a multicast address (excluding broadcast addresses). Total number of packets received with valid size with checksum or alignment errors. Total number of packets received with fewer than 64 octets, otherwise well-formed. ISL and 100Mb ports are exact. 10Mb ports are missing octets from packets directed to the CPU, with errors, dropped due to buffer overflows, or limited to the local segment. 10Mb ports can only count octets of packets forwarded to other ports on the switch. ISL ports are exact. All other ports include packets from other ports to this port that may have been dropped internally, a very infrequent event. ISL ports are exact. All other ports are missing broadcast packets transmitted by this port and include broadcast packets with errors. ISL ports are exact. All other ports are missing multicast packets transmitted by this port and include multicast packets with errors. All ports are exact. ISL ports are exact. All other ports include short packets with errors, which are defined as etherstatsfragments. 9-16 Catalyst 3200 Installation and Configuration Guide

Using an RMON Application Statistic Name Definition Differences etherstatsoversizepkts etherstatsfragments etherstatsjabbers etherstatscollisions etherstatspkts60octets etherstatspkts65to127octets etherstatspkts128to255octets etherstatspkts256to511octets etherstatspkts512to1023octets etherstatspkts1024to1518octets Total number of packets longer than 1,518 octets, otherwise well formed. Total number of packets received with fewer than 64 octets, with checksum or alignment errors. Total number of packets received longer than 1518 with checksum or alignment errors. Best estimate of the total number of collisions on this ethernet segment. Total number of packets (including bad packets) received in this size range. ISL ports are exact in non-isl mode but are reported as 0 when port is in ISL trunk mode. All other ports include long packets with errors, which are defined as etherstatsjabbers. ISL ports are exact. All other ports include short packets without errors, which are defined as etherstatsundersizepkts. ISL ports include all packets larger than 1536 bytes. All other ports include long packets without errors, which are defined as etherstatsoversizepkts. ISL ports are exact. All other ports count all packets that have collided at least once on this network segment, rather than counting the separate collisions. ISL ports are exact. All other ports are 0. There is no way to get the packet size distribution without the appropriate hardware counters, because most packets are switched by the hardware. Monitoring Port Activity with Application Software 9-17

Using an RMON Application 9-18 Catalyst 3200 Installation and Configuration Guide