EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

Similar documents
A Line of Fixed-Port Industrial Ethernet 10/100 Mbps Switches INSTALLATION GUIDE

EISB Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed and Unmanaged Ethernet Switching Hubs

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

AI-SRVR Series ARCNET Server to Ethernet Client

SHEET. CTRLink. Automation Switch Series comprehensive set of features plus high port density. EIDX_M Series

USB22 Series INTRODUCTION INSTALLATION GUIDE

16- or 24-port Managed Switching Hubs

AI-SRVR Series INSTALLATION GUIDE CONTEMPORARYCO

USB22 Series INTRODUCTION INSTALLATION GUIDE

SHEET. Automation Switch Series comprehensive set of features plus high port density and PoE. EIDX_MP Series

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

10BASE-T/ 10BASE-FL or 100BASE-TX/100BASE-FX compliant. Auto-negotiated data rate and flow control on twisted-pair ports

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

BASRTP-B. Portable. BACnet Multi-Network Router. Installation Guide. TD II For Firmware Versions 2.7.x

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

EISC Series Ethernet Configurable Switch Hubs. User Manual # TD MB

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

CNSEISK 5, 8 & 16- Port Copper and Fibre Sub Miniature Ethernet 10/100 Switches

CTI 3570A SERIES INDUSTRIAL ETHERNET SWITCH INSTALLATION AND OPERATION GUIDE Version 1.2

Stride Industrial Ethernet Switches

Universal Voltage PCI Bus ARCNET Network Interface Modules INSTALLATION GUIDE

FSM-510G Series Ethernet Management Switch Quick Start Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Owner s Manual. Media Converters Models: N SC & N ST

EDG Port Industrial 10/100 Mbps Ethernet Switch. User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

EIGR-E Series Skorpion Gigabit Wired IP Routers

KFC-200. Installation Guide

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

PTC-101 Quick Installation Guide

Industrial PoE Media Converter

Instruction Manual MX2-MM-LX-SC MXR2-MM-LX-SC MX2-SM-LX-SC MXR2-SM-LX-SC Media Converter

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch. ISW-500T/ISW-800T User s Manual

INDUSTRIAL POE SWITCH

WaveLine managed switches with IOs

Switch manual Models &

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Industrial Switches Industrial Switches

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

ex-s1110-xt Gigabit Ethernet Extenders

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Industrial Switches. 9 Industrial. Industrial Switch, 5 Ports 100Base-TX 554 Industrial Switch, 8 Ports 100Base-TX 555

Industrial Slim Type Fast Ethernet Rail Switch

Industrial 3-Port Fast Ethernet Media Converter Switches

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Quick Start Guide Elinx ESW500 Series. Managed Din Rail Ethernet Switch

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

RightWON Satellite Ethernet switch module (ESM), multi-mode

Hardened PoE Ethernet Switch

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

Fieldbus Extender for DeviceNet

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Owner s Manual. Media Converters

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

PTC-101-M12 Hardware Installation Guide

Overview. Features CHAPTER

Enclosure TS-530 User Manual

IMC-21 Quick Installation Guide

ROCKETLINX ES7110. Quick Installation Guide Rev C ES7110 ES7110-VB. Industrial PoE Switch

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

Rugged Industrial Media Converter

BASRT-B. BASrouter. BACnet Multi-Network Router. Installation Guide. TD IP For Firmware Version 2.7.x

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

TC /100Base-T Ethernet Fiber Optic Switch User's Manual. 4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

IMC-21A Quick Installation Guide

10/100Base-TX to 100Base-FX Media Converter

exp-s1110pe PoE+ Gigabit Ethernet Extenders

ROCKETLINX ES7110 ES7110/ES7110-VB

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

ADAM Fiber Optic to RS-232/422/485 Converter

FLEXPOINT MODULAR MEDIA CONVERTERS

iconverter 1-Module Redundant Chassis

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

800xA Networks. NE801 User Manual. Power and productivity for a better worldtm

5/8-Port 10/100/1000Mbps. Industrial Gigabit Ethernet Switch IGS-501 / IGS-801 / IGS-501T / IGS-801T. User's Manual

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

EXTEND-A-BUS for. A Line of Fieldbus Extenders for DeviceNet. User Manual #TD MF

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

LevelOne FSW PoE Fast Ethernet Switch User Manual

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

IES7110-2GS Series. Managed Industrial Ethernet Switch. User manual. Summarize. Panel layout. Packing list. Feature

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

Manual Elinx EIR408-T. 8 Port-10/100/1000 Unmanaged Din Rail Ethernet Switch

Transcription:

EIDX_M Series A Line of Managed Ethernet Switching Hubs INTRODUCTION INSTALLATION GUIDE The EIDX_M Series of managed Industrial Ethernet switches provides the user with a sophisticated instrument with several advanced features for the discriminating network professional. Each of the 8 models in the series operates in extended temperatures while offering a choice of mounting, port count, media and support. To optimise speed and throughput, some functions are automatically negotiated: Each twisted-pair port automatically optimises its data rate to 10 Mbps or 100 Mbps. The data rate of fibre ports is fixed at 100 Mbps. Each port negotiates flow control supporting the PAUSE function for fullduplex links, and using the backpressure scheme for half-duplex segments. All units offer non-blocking wire-speed operation with a maximum data rate of 148,810 frames per second for 100 Mbps Ethernet on all ports at full duplex. Copper ports are wired MDI-X (internal crossover) for attaching NICs via straightthrough cables. All units support SNMP and offer these advanced features: RapidRing high-speed redundancy (link loss recovery under 300 ms) VLANs to limit broadcast/multicast domains and improve performance Trunking to allow high-bandwidth redundant backbones QoS message priority for either port-based or MAC-based priority Programmable fault relay to indicate the loss or addition of a link Auto-MDIX for all copper ports enabled/disabled by software control All units operate from low-voltage AC/DC sources and redundant power connections are available for backup considerations. They come with the ability for either DIN rail or panel mounting. The front panel features LED indicators for power and CPU status and link status, activity and data rate of each port.

SPECIFICATIONS Electrical (for 24-port models) INPUT DC AC Voltage ±5%: 24 VDC 24 VAC Power (max): 14 W 35 VA Temperature Operating: Storage: Shipping Weight 2 lbs. (.9 kg) 40 C to +75 C 40 C to +85 C Regulatory Compliance CE Mark; CFR 47, Part 15 Class A UL508 Listed Industrial Control Equipment (intended for use with Class 2 circuits) Functional Compliance: ANSI/IEEE 802.3 Data Rate: Signalling: LED Indicators Power Status Ports 10 Mbps and 100 Mbps 10BASE-T, 100BASE-TX, 100BASE-FX green red/green green/yellow Warning: This is a Class A product. In a domestic environment the product may cause radio interference in which case the user may be required to take adequate measures. Mechanical Figure 1 EIDX Dimensions 2

RJ-45 Connector Pin Assignments PIN MDI-X 1 TD+ 2 TD 3 RD+ 4 unused 5 unused 6 RD 7 unused 8 unused Figure 2 RJ-45 Connector 3

INSTALLATION Mounting The EIDX is designed for mounting in an industrial enclosure or wiring closet using either set of the provided mounting hardware listed below: TS-35 DIN Rail Mounting Panel Mounting DIN rail clip Panel mounting bracket M3x5 screws, flat-head (4) M3x5 screws, flat-head (4) For quick snap-mounting to 35 mm DIN rail, a reinforced DIN rail clip is preattached to the back of the EIDX enclosure with four M3x5 flat-head screws. If the clip is removed, the EIDX can be panel-mounted by extending the top and bottom brackets which are shipped in retracted position. The extended brackets can then anchor the EIDX to a wall or other flat vertical surface with two #8 pan-head screws (not provided). The left illustration of Figure 3 shows a rear view of the EIDX with brackets in retracted position. The right illustration of Figure 3 shows the brackets extended and secured to the EIDX enclosure with the same screws used in retracted position. Figure 3 Using the Panel-Mounting Brackets 4

Cabling Considerations When attaching signal cables to the EIDX, Table 1 should be considered. Medium Signalling and Data Rate Minimum Required Cable Maximum Segment Distance Copper Copper Fibre Fibre 10BASE-T 10 Mbps 100BASE-TX 100 Mbps 100BASE-FX 100 Mbps 100BASE-FX 100 Mbps Category 3 UTP Category 5 UTP 1300 nm, multimode 50/125 or 62.5/125 µm 100 m (328 ft) 100 m (328 ft) Full-Duplex : 2 km (6562 ft) Half-Duplex : 412 m (1352 ft) 1300 nm, single-mode Full-Duplex : 15 km (49213 ft) Half-Duplex : 412 m (1352 ft) Table 1 Cabling Considerations Observe in Table 1 that segment distance is very limited when using copper media regardless of data rate. Although 10BASE-T links can successfully use Category 3, 4 or 5 cable 100BASE-TX segments must use Category 5. A popular choice for improved distance is multimode fibre which also gives good electromagnetic noise immunity and optimum protection from lightning strikes. Considerable distance can be achieved in full-duplex mode and the greatest distance can be realized in full-duplex mode with single-mode fibre. Note that half-duplex operation yields a modest, fixed distance which does not vary with the type of fibre in use. This is because half-duplex mode is limited by the collision domain irrespective of the length and type of fibre. EIDX switches offer three types of field connectors. Copper ports accept RJ-45 modular plugs. Two choices of fibre connectors are available: ST and SC. 5

Powering The EIDX requires low-voltage AC or DC power via a four-pin removable keyed connector. Power conductors can be stranded (16 18 AWG) or solid (16 22 AWG). Consult the Specifications section for power requirements. The various power options are explained below. DC Powered NOTE: This device is intended for use with Class 2 circuits. The EIDX accepts a voltage of 24 VDC ±5% and draws current commensurate with power consumption. Power conductors should be sized accordingly. COM and the equipment chassis are isolated from zero volts. The input connections are reverse-polarity protected. Figure 4 DC Powered Redundant DC Powered Figure 5 Redundant DC Powered Redundant diode-isolated DC power inputs are provided so the EIDX can operate despite the loss of primary power. Both sources must provide required power. AC Powered The EIDX accepts a voltage of 24 VAC ±5% and draws current commensurate with power consumption. Figure 6 AC Powered AC Powered with Battery Backup The EIDX can also operate in the AC mode with a backup battery providing power if the AC source fails. The EIDX does NOT charge the battery, so separate provisions are required for charging. Figure 7 AC Powered with Grounded Secondary Figure 8 AC Powered with Battery Backup 6

LED Indicators Power This LED glows green when proper power is applied to the EIDX. Status This bicolour LED will be green in an operational state and red in a fault state. The green LED blinks periodically to indicate the management CPU is fully operational. Port Each port has an associated bicolour LED which glows green when a valid Ethernet link has been established at 100 Mbps but yellow if the data rate is 10 Mbps. The LED flashes when data transfer is occurring. Port Locations Ports 1 8 are accessed on the front panel. Other ports are located on the bottom of the enclosure and for 24-port models, also on the top surface. An example of port arrangement on the top and bottom of the enclosure is shown in Figure 6 which locates a few of the ports on the model EIDX24M-100T/FC. Fault Relay This relay is disabled by default. Its operation is explained in the Software Manual. Its contact is normally closed and rated at 500 ma, 24 V (max). Figure 9 Port Locations Console Port The Console Port uses the standard RS-232 protocol for configuring the switch. For proper communication : Set the Baud rate to 9600. Set the Data bits to 8. Set the Parity to None. Set the Stop bits to 1. Set the Flow control to None. Figure 10 Console Port 7

NEED MORE HELP INSTALLING THIS PRODUCT? Additional information exists on our web site at www.ccontrols.com. When contacting one of our offices, just ask for Technical Support. WARRANTY Contemporary Controls (CC) warrants its new product to the original purchaser for two years from the product shipping date. Product returned to CC for repair is warranted for one year from the date that the repaired product is shipped back to the purchaser or for the remainder of the original warranty period, whichever is longer. If a CC product fails to operate in compliance with its specification during the warranty period, CC will, at its option, repair or replace the product at no charge. The customer is, however, responsible for shipping the product; CC assumes no responsibility for the product until it is received. CC s limited warranty covers products only as delivered and does not cover repair of products that have been damaged by abuse, accident, disaster, misuse, or incorrect installation. User modification may void the warranty if the product is damaged by the modification, in which case this warranty does not cover repair or replacement. This warranty in no way warrants suitability of the product for any specific application. IN NO EVENT WILL CC BE LIABLE FOR ANY DAMAGES INCLUDING LOST PROFITS, LOST SAVINGS, OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT EVEN IF CC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, OR FOR ANY CLAIM BY ANY PARTY OTHER THAN THE PURCHASER. THE ABOVE WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED OR STATUTORY, INCLUDING THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR USE, TITLE AND NONINFRINGEMENT. Returning Products for Repair Return the product to the location where it was purchased by following the instructions at the URL below: www.ccontrols.com/rma.htm DECLARATION OF CONFORMITY Information on the regulatory compliance of this product exists at the URL below: www.ccontrols.com/compliance.htm 8