Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

Similar documents
Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

Liebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Precision Cooling. Precision Cooling Advantages

PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers

Liebert : The Right Cooling For IT Environments

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Liebert. icom Thermal System Controls Greater Data Center Protection, Efficiency & Insight

Rack & Enclosure Systems

We Invented Precision Cooling

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

Liebert APM. The Compact, Row-Based UPS with Flexpower Technology 30kW - 300kW

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Liebert NX Series. 30kVA to 200kVA. AC Power For Business-Critical Continuity

Liebert. PCW from 25 to 220 kw. Chilled Water Units Optimizing Data Center Efficiency

APMTM UPS 30kW - 300kW The Compact Row-Based UPS With Flexpower Technology

Ecotel Free Cool 5-15kW

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Liebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert PDX from 15 to 120 kw

Liebert PDX from 15 to 120 kw

Total Modular Data Centre Solutions

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Liebert RDU-M Dynamic Environment Monitoring for Secure Data Center Infrastructure

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Liebert PCW. Cool the Cloud

Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Why would you want to use outdoor air for data center cooling?

Liebert. PDX and PCW Compact Perimeter Cooling Solutions

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

SUPERSAVER. Energy Efficiency Optimization Software for Freecooling Systems

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Ecoflair Air Economizers

Liebert exm, 80kW - 200kW

Liebert HPM from 4 kw to 100 kw

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Product Brochure Eaton 93PR UPS kw

Close-coupled cooling

Precision Cooling for Business-Critical Continuity. Liebert CRV. Efficient Cooling For IT Equipment NEW. Extended Range Available From 10 To 50 kw

Data Center Optimized Controls

MSYS 4480 AC Systems Winter 2015

Rittal LCP T3+ High-availability IT cooling with no compromise

Liebert DCW CATALOGUE

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

SmoothAir Modular Precision Cooling

Reducing Data Center Cooling Costs through Airflow Containment

Tel: AC Power for Business-Critical Continuity TM

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Liebert APM 30, 60, 90, 120, 150kVA UPS Adaptive Power Quality Solution for Critical Applications

Power and Cooling Design Guidelines for Network Access Rooms. A White Paper from the Experts in Business-Critical Continuity TM

Liquid Cooling Package LCP Cooling Systems

Running Your Data Center Under Ideal Temperature Conditions

Schneider Electric Easy UPS 3S

INNOVATE DESIGN APPLY.

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

INNOVATE DESIGN APPLY.

Liebert NXC from 10 to 60kVA

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

DATA CENTER AIR HANDLING COOLING SOLUTIONS

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

Environmental Monitor (RSMICRO)

VERTIV SERVICE CAPABILITY

Thermal management. Thermal management

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Liebert GXT MT kva

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

Liebert NXC. 10 to 40kVA Compact and Reliable Power in a Fully Integrated Packaged Solution

Installation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Rack cooling solutions for high density racks management, from 10 to 75 kw

CTC Low Temperature Process Chillers

Transcription:

Liebert DM High Performance, Sensible Cooling for Small Computer Rooms and Network Closets

Emerson Network Power, a business of Emerson (NYSE: EMR), is a worldwide leader in infrastructure solutions across the globe. Emerson Network Power delivers innovation and solutions without sacrificing efficiency, availability and reliability. Its 12 Centres of Expertise are distinct and uniquely positioned to help you achieve your business objectives, identifying which solutions fit your requirements. Over the years, Precision Cooling systems from Emerson Network Power have been proven as the world s standard for reliable operations in computer rooms and critical infrastructure applications. Installed in thousands of data centres around the world, our latest precision cooling portfolio offers the highest efficiency and flexibility without compromising reliability for your mission critical operations. 2

Why Precision Cooling? Start with the right kind of Cooling Some operations use standard comfort cooling systems to save money or to avoid using additional floor space within the facility. But this approach may provide some benefits in the short term they must be balanced against the cost of downtime and equipment damage resulting from serious overheating as well as the risk of financial loss. Issues when using Comfort Cooling in Small Data Centre/Computer Room (Datacom Rooms) 1. Using rigid over head ducts provides insufficient air volume (45-55 l/sec per kw) which results in hot spots, and they are also difficult to relocate 2. Comfort cooling systems cannot control humidity levels and do not typically have integral humidity control. 3. Using separate humidification systems, not controlled by the cooling system, can waste energy and reduce the stability of the environment. These issues can have long and short term effects on your IT operations. The business risks range from degraded IT services to system interruption and shutdown. 3

Precision Cooling vs. Comfort Cooling Computers Generate Heat, But Not Humidity. 100% 90% Offices & Non IT Rooms 80% generate lots of moisture due to human 70% activities 35% 10% 60% 50% 40% 30% 65% 90% IT equipment rooms have high sensible (temperature) heat loads 20% 10% 0% Office & Non-IT Rooms Datacom Rooms Latent Sensible 90%-95% of a precision cooling system s energy and capacity are designed to remove the dry heat that electronic equipment produces. Comfort cooling systems are designed to keep people comfortable and are only capable of using about 60%-65% of their cooling capacity to remove heat generated by computers. The other 35%-40% is used to remove moisture, commonly found in office space, but not server or network rooms. This can lower humidity too much causing electricity problems and even electronic failure. Why run the risk of relying on building air? RISK: These systems shut down overnight and weekends RISK: Systems designed to operate 5 x 8 vs. Continuous Operation RISK: Insufficient filtration for IT equipment and no humidity control RISK: Building air removes too much moisture, introducing the risk of static discharge RISK: Insufficient airflow causes overheating in IT equipment COST: Building air is designed to cool people (heat and perspiration) As a consequence a lot of energy (cost) goes into removing moisture Energy is wasted where building air is used to cool IT equipment 4

Liebert DM Domestic/Split Systems Benefits Comment Temperature Control +/- 1C +/- 3C Stable temperatures ensure operational integrity and reliability of IT equipment Wide temperature fluctuations shorten operational life of IT equipment and will increase the risk of catastrophic failure Humidity Control +/- 5%RH > =/- 15% RH Only Precision cooling units can control room humidity High humidity can lead to condensation and corrosion, low humidity increases the risk of electrostatic discharge, both are major threats to IT equipment Network Managed Yes IP network managed No Liebert DM is a network managed device. It will notify you if there is a failure or potential threat to your equipment Standard IP connectivity: Email (SMTP) SMS (through email gateway) SNMP (MIB and trap support) HTTP (browser) Optional temperature and humidity sensors can be placed directly into the racks Reliability and Warranty for 24x7 operation Yes No Liebert DM Precision cooling is designed to run nonstop in demanding IT environments Domestic air conditioning warranty only covers applications for human comfort and explicitly not for the climatic control of electronic equipment. Load sharing/ Duty Cycling Yes No Interconnected units provide standby rotation and lead/ lag operation through a single cable Domestic units require third party or customised management devices adding complexity, warranty and operational risk Operational life 10 years+ 1-3 years est. Not designed for IT operations Liebert DM is designed to run 24hrs x365 with a mean time to failure of 4 years. Domestic units typically designed to run only 2000-4000 hours/year If you run a Domestic unit 24hrsx365 the expected mean time to failure is 1 year!! Operating Range -10C to 46C Most Domestic units will only provide cooling when the outside temperature is above 10C Liebert DM provides continuous cooling operation down to -10C outdoor temperatures. (-30C optional). Most comfort systems can only cool if the outside temperature its above 10C. Domestic systems are designed to cool in summer and heat in winter, IT equipment requires cooling all year round. Misapplication may lead to loss of cooling 5

Product Overview Liebert DM delivers enterprise level precision cooling to small computer rooms and network closets. It is designed for year-round temperature and humidity control for IT applications across the critical infrastructure. With a small footprint it is ideal for small and medium-sized computer rooms. The Liebert DM is a fully featured precision cooling solution for your critical IT infrastructure. It also features network management capabilities and integrates with your standard IT management systems using standard IT protocols such as http, SMTP, SNMP and SMS. Liebert DM variants: Air Cooled / Water Cooled Chilled Water The Liebert DM is ideally suited for: Small and medium sized computer rooms UPS and battery rooms Outdoor electronic and communication equipment rooms Transformer stations, substations Description Air Cooled / Water Cooled Chilled Water System Models DME07 & DME12 DMH09U/D/F, DMH12U/D/F, DMH17U/D/F & DMH25U/D/F Available Capacities 7.5kW & 12.5kW 8.2kW, 11.6kW, 16.3kW & 23.2kW Upflow Plenum Yes Yes Ducted No Yes Downflow No Yes Power Supply 400V/3PH/50Hz 400V/3PH/50Hz Condenser Type Air Cooled: Outdoor Condenser Water Cooled Heat Exchanger Not Applicable Refrigerant R407C Not Applicable 6

Features and Benefits Energy saving Energy efficient design optimised for IT applications Equipped with Copeland Scroll Compressors Provides stable temperature and humidity environment Intelligent outdoor fan speed control ECO-mode and other energy saving options Space Saving Small footprint 100% front service access User-Friendly and Maintenance-Free Large screen display with multi-level password protection and expert fault-diagnosis functions Automatic startup on power recovery and scheduled startup also available Monitoring and exception management through standard network interface and protocols Loss of air and filter clog event notification Email and SMS notification for remote monitoring functions Highly adaptive Designed for 24x7 operation Ultra wide input voltage range; multiple power protection functions 7

Liebert DM Air Cooled / Water Cooled Series The Liebert DM Air Cooled and Water Cooled Precision Cooling System is suitable for precise air conditioning of small and medium sized computer rooms and UPS & Battery rooms. Designed with the latest precision cooling technology, the Liebert DM Air Cooled and Water Cooled series has passed industry standards for precision cooling systems and features high energy efficiency, excellent reliability and long service life. The user friendly LCD display allows the operator to set temperature and humidity setpoints. The Water Cooled series adopts a separate water cooled heat exchanger module and rejects heat thru the circulating condenser water from its source. Key Features of the Liebert DM Air Cooled Series: Highly adaptable to environment conditions and varying temperature Equipped with Scroll Compressor Eco-mode option available Variable speed and low noise fans for outdoor units Front door access Constant temperature and humidity function Large on screen display (OSD) with multi-level password protection Product series Automatic and scheduled startup functions up to 2 units RS485 monitoring interface standard Low maintenance Wide input voltage range and multiple power protection functions (400V +10%/-20%) Compatible with remote monitoring software Model Cooling Capacity (kw) Heating capacity (kw) Humidifying capacity (Kg/h) FLA (A) Indoor unit size L x W x H (mm) Standard condenser Low-temperature condenser DME07MHP1 Heating and humidifying DME12MHP1 Heating and humidifying 7.5 3.2 1.5 20 510 385 1750 12.5 3.2 2.5 22 600 500 1850 DMC07WT1 (787 352 829) DMC12WT1 (787 352 1240) DML07W1 (1037 352 829) DML12W1 (1037 352 1240) Optional water cooled heat exchanger Model Water flow m 3 /h Pressure drop (kpa) DMW07 1.65 15 DMW12 2.9 25 Dimension and weight Unit Model Length x Width x Height (mm) Weight (kg) Water cooled heat DMW07 843 533 704 35 exchanger DMW12 843 533 704 35 Standard Options and Accessories Air/Water Cooled Systems Extended Piping Kit (Air Cooled Only) Lee-temp Condenser Unit (Air Cooled Only) Water Cooled Heat Exchanger (Water Cooled Only) Power SPD Energy Saving Card Network Management card (RDU-SIC) 8

Liebert DM Chilled Water Series The Liebert DM Chilled Water utilizes low-temperature chilled water available on site as the cooling source and does not require an outdoor unit. This is ideally suited to computer rooms located in commercial buildings with adequate chilled water source. Key Features of the Liebert DM Chilled Water Series: Eliminates outdoor condenser, ideal for small rooms Eco-mode option available Front door access Constant temperature and humidity function Large on screen display (OSD) with multi-level password protection Automatic and scheduled startup functions RS485 monitoring interface standard Low maintenance Ultra-wide input voltage range and multiple power protection functions (400V+15%/-20%) Compatible with remote monitoring software Product series Model Cooling Capacity (kw) Heat capacity (kw) Humidifying capacity (kg/h) Water flow (l/s) Chilled water parameters Total pressure drop (kpa) Inlet/outlet water pipe diameter (mm) DMH09U/D/FMH1 8.2 4 3 0.39 46 25 DMH12U/D/FMH1 11.6 4 3 0.55 62 25 DMH17U/D/FMH1 16.3 6 5 0.78 46 32 DMH25U/D/FMH1 23.2 6 5 1.1 45 32 Remark: 1. As for Model, U indicates upflow unit (supply via hood), D indicates upflow unit (supply via duct), F indicates downflow unit (supply under floor). 2. Test conditions: 400V/50Hz ~ 3P, indoor temperature of 24 C, relative humidity of 50%RH, chilled water supply temperature of 7 C and return temperature of 12 C. 3. The system is configured with two-way valve as a standard configuration, with three-way valve optional. 4. If the water pressure of chilled water system is higher than 1600kPa, please contact Emerson Network Power. 5. If the required data are not listed in the table, please contact Emerson Network Power. Dimension and weight Unit model Number of fan(s) Length x Width x Height (mm) Weight (kg) DMH09U/D/FMH1 1 510 386 1740 90 DMH12U/D/FMH1 1 608 575 1900 127 DMH17U/D/FMH1 2 1102 386 1740 169 DMH25U/D/FMH1 2 1202 575 1900 210 Standard Options and Accessories Chilled Water System Energy Saving Card RDU-SIC Card 9

Communications The Liebert DM Series can be managed through your IP network. As a standalone network management device it provides the following: Browser access through HTTP protocol Email notifications of critical events and potential operational impacts SMS alerts through your SMS gateway SNMP management through GET/SET requests and industry standard MIB It is also compatible with Emerson management and monitoring systems for comprehensive integration with computer rooms and critical applications. Liebert RDU Monitoring Interface The Liebert RDU offers maximum visibility for insight in the infrastructure. 10

The Liebert DM is ready to respond to the challenges and rapid changes in the critical infrastructure, be it power disturbances or fluctuating humidity levels. The Liebert DM delivers 24 x 7 precision cooling in the critical space. 11

Emerson Network Power Asia Australia T: 1800-065345 F: 61-2-97438737 Indonesia T: 62-21-2513003 F: 62-21-2510622 Japan T: 81-3-54038564 F: 81-3-54032919 Korea T: 82-2-34831500 F: 82-2-5927886 Malaysia T: 603-78845000 F: 603-78845188 Pakistan T: 92-42-36622526 to 28 F: 92-42-36622530 Philippines T: 63-2-7207400 F: 63-2-6203693 Singapore T: 65-64672211 F: 65-64670130 Thailand T: 66-2-6178260 F: 66-2-6178277 to 78 Vietnam T: 84-4-37628908 F: 84-4-37628909 New Zealand T: 64-3-3392060 F: 64-3-3392063 Emerson Network Power. www.emersonnetworkpower.asia While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. Emerson Network Power and Liebert are trademarks of Emerson Electric Co. or one of its affiliated companies. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. 2013 Emerson Electric Co. AU13DPG-LiebertDMV1-BR