EUROPEAN STANDARD EN : 2000 EUROPEAN STANDARD EN : A1: TEST DATE 06, 10 and 14 April 2004

Similar documents
Reg Model : SKR001 Regulatory Assurance Certification

OBSOLETE. CanWorks itrax Two-Channel Control Unit Installation. Instruction Sheet P/N A

ELECTRONICS TESTING CENTER, TAIWAN Report No.: RBO EMC TESTING DEPARTMENT Page: 1/9

Test Report. Product Name : Stackable Gigabit Ethernet Switch Model No. : DGS-3224SR, DGS-3324SRI, DGS-3324SR, DPS-500, DPS-900

SANnet II Family Safety, Regulatory, and Compliance Manual

F1000 User's Manual. (Version: V1.01)

Coda cx1 EMI/EMC Test Procedure

General-Purpose 8-Slot Chassis for PXI

Installation Requirements for Conformance to Standards

CompuScope 3200 product introduction

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

Recommended Practices for Installation For EC Directive 2004/108/EC Relating to EMC Supplement to Installation and Operating Manual

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

NIST Designation of CABs: Upcoming Changes for the US and EU Review for Japan

ENGINEERING SPECIFICATION. 40W AC Adaptor. Part Number: PA W1

HEC-100RTN-48QSCA Rev A1.0

Power Factor Model Number Voltage Voltage

C-Bus Pascal Automation Controller

TEST REPORT. Fobsun Electronics Limited

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

LED Driver. Xitanium DALI 40W A 54V DALI XI040C110V054YPT2

CompuScope product introduction

AXIS 250S Blade Rack Solution Installation Guide

Modular 8-Port Mid-span Power over Ethernet Injector

1 LIMITED WARRANTY STORCASE TECHNOLOGY, Incorporated ( StorCase ) warrants that its products will be free from defects in material and workmanship, su

CE Radio Test Report

Revision Issue Date Pages Affected A0 08/14/2006 ALL Modify From CP-8120 Specification Rev:ED by Customer given.

DPS SERIES DC POWER SUPPLIES

AX3000 Platine Terminal Ethernet TCP/IP

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

EI Series INSTALLATION GUIDE INTRODUCTION. A Line of Fixed-Port Industrial Ethernet Hubs

Safety Standards. Model Number:

1.0 Description. 2.0 Unpacking. 3.0 Installation

AX3000 Platine Terminal Ethernet TCP/IP

ACT-1B Series Panel Tachometer

Efficiency (1) 110Vac 220Vac. (2, 3) 3330 ma 90 ~ 305 Vac 11 Vdc 35 W 84% EUC-040S333DS(6) EUC-040S333PS(6)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. LAIRD TECHNOLOGIES, INC. W66 N220 Commerce Court Cedarburg, WI Adam Alger Phone:

CompuScope 1602 product introduction

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

HP Deskjet 3550 Series Printers - Product Specifications

Embed AIO v5 User Manual

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Efficiency (1) 110Vac 220Vac

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

ONETECH Testing & Evaluation Lab.

CERTIFICATE. Issued Date: Sep. 15, 2011 Report No.: R-ITUSP02V02

Efficiency (1) 110Vac 220Vac

VCCI CLASS B COMPLIANCE REPORT

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

H-series (Rectifier Module)

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

Reliable ATX 12V 2.01 Power Supply

Industrial PC for real-time rapid prototyping KEY FEATURES

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

Technical Documentation

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

IVN Safety Guidelines GETTING STARTED GUIDE. 100BASE-T1 Media Converter

Installation Instructions

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Versatile, Automatic RCL Meters

Typical Efficiency (2) 0 ~ 12.5 A 150 W 90.0% EUV-150S012DTA(STA) 0 ~ 6.25 A 150 W 90.5% EUV-150S024DTA(STA) (4)

60 Watt Medical (MWLT)

The SFP BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD). Datacom Distributed Power Systems

Barracuda Web Application Firewall Hardware Features

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

Installing the Tracer MP503 Input/Output Module Ordering number: ,

2 Channel DALI Power Supply and Interface Installation Instructions. This page was intentionally left blank

Typical Efficiency (2) 350 ma 90 ~ 305 Vac 57~114Vdc 160 W 92.0% EUC-160Q035DT(ST) (3 ) Parameter Min. Typ. Max. Notes

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Installation Guide Controller Series E130/E230/E430

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Read Me First for the HP ProCurve Wireless Products - software ver

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy

Environmental. Electrical Specifications at 25 O C. Programmable Maximum Value. Factory Default

Model SPDT Switch Module

SFP450-12BG AC-DC Front-End Data Sheet 12V Output, 450 Watts

ENGINEERING SPECIFICATION 90 WATT POWER SUPPLY PART NUMBER PA P1

Typical Efficiency (2) Max. Output Power. 700 ma 140 ~ 305 Vac 107 ~ 214 Vdc 150 W 92.0% 0.96 EDC-150S105SV-0007

Ethernet/Serial Interfaces for Compact FieldPoint

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

DENISON HYDRAULICS Jupiter Power Supply Accessory Series S

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Constant Voltage Mode

SYSTIUM MODEL 526EX UATX

OPERATING MANUAL. Measurement Microphones

INSTALLATION GUIDE ADAPTEC SCSI CARD 29320LP

HYDROTHUNDER PARTS C H A P T E R F O U R

CERTIFICATE. Issued Date: Aug. 16, 2012 Report No.: R-ITCEP07V03

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

Enclosed Power Supplies

^2 Accessory 8DCE ^1 USER MANUAL. ^3 CE Certified PC Board/Terminal Block. ^4 3Ax xUxx. ^5 October 27, 2003

SySTIUM TM TECHNOLOGIES Model 215

REVISION HISTORY REV DESCRIPTION SALES RFS DATE A INITIAL RELEASE MS /20/2011 B UPDATE LABEL: CHANGE CQC PSE NAME TO COGNEX K.K.

zseries 9-Slot Chassis 9-Slot 3U PXI Express Chassis

CONTROL MICROSYSTEMS and 5404 Digital Input Module. Hardware Manual

WI-130 WDAC User s Manual

8x16, 2-Wire Terminal Block for the NI PXI The following conventions are used in this guide:

Transcription:

PRODUCT SERVICE TEST RESULT SUMMARY EUROPEAN STANDARD EN 61000-3-2: 2000 EUROPEAN STANDARD EN 61000-3-3: 1995 + A1: 2001 MANUFACTURER'S NAME MODEL NUMBER(S) / DESCRIPTION MANUFACTURER'S ADDRESS TEST REPORT NUMBER Performance Design Incorporated OD4012 - Paper Punch Machine CI4170 - Paper Punch Machine APES-14 - Paper Take-Away/Stacking Paper System HD7000 - Paper Punch Machine HD7500 - Paper Punch Machine 2350 East Braniff Boise, ID 83716 WC400764.1 TEST DATE 06, 10 and 14 April 2004 According to testing performed at TÜV Product Service Inc, the above-mentioned unit is in compliance with the electromagnetic compatibility requirements defined in European Standards EN 61000-3-2: 2000 and EN 61000-3-3: 1995 + Amendment A1: 2001. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical characteristics. Any modifications necessary for compliance made during testing on the above mentioned date(s) must be implemented in all production units for compliance to be maintained. TÜV Product Service Inc, as an independent testing laboratory, declares that the equipment tested as specified above complies with the requirements of European Standard EN 61000-3-2: 2000: Electromagnetic Compatibility Part 3-2: Limits - Limits for Harmonic Current Emissions (Equipment Input Current 16 Amps Per Phase), and with European Standard EN 61000-3-3: 1995: Electromagnetic Compatibility Part 3-3: Limits - Limitation of Voltage Changes, Voltage Fluctuations and Flicker in Public Low-Voltage Supply Systems for Equipment with Rated Current 16 Amps Per Phase and not Subject to Conditional Connection + Amendment A1: 2001. Date: 29 March 2005 Location: New Brighton MN Michael Schultz Ronald R Amundson USA EMC Technician EMC Engineer Not Transferable TÜV PRODUCT SERVICE INC 1775 Old Hwy 8 NW, Suite 104 New Brighton MN 55112-1891 USA Tel: 651 631 2487 Fax: 651 638 0285 Rev.No 1.0

Form EMC Test Plan and Constructional Data Form PLEASE COMPLETE THIS DOCUMENT IN FULL, ENTERING N/A IF THE FIELD IS NOT APPLICABLE. Applicant -- NOTE: This information will be input into your test report as shown below. Press the F1 key at any time to get HELP for the current field selected. Company: Address: Performance Design Inc. 2350 East Braniff Boise ID 83716 Contact: Frank Bagrosky Position: General Manager Phone: 208 384 8551/845 236 7224 Fax: 1208 384 8583 E-mail Address: fbagrosky@rhin-o-tuff.com General Equipment Description -- NOTE: This information will be input into your test report as shown below. EUT Description EUT Name see excel doc. see excel doc. Model No.: see excel doc. Serial No.: see excel doc. Product Options: Configurations to be tested: used by itself except for APES-14 Mounts on other punch machine one by itself except for APES-14 Mount on another punch machine Test Objective EMC Directive 89/336/EEC (EMC) FCC: Class A B Part Std: EN61000-6-1 and EN61000-6-3, EN610003-2, EN61000-3-3 VCCI: Class A B Machinery Directive 89/392/EEC (EMC BSMI: Class A B Std: Canada: Class A B Medical Device Directive 93/42/EEC (EMC) Australia: Class A B Std: Other: Vehicle Directive 72/245/EEC (EMC) Std: FDA Reviewers Guidance for Premarket Notification Submissions (EMC) TÜV Product Service Certification Requested Attestation of Conformity (AoC) Certificate of Conformity (CoC) EMC Certification (used with Octagon Mark) Compliance Document Protection Class (N/A for vehicles) Class I Class II Class III (Press F1 when field is selected to show additional information on Protection Class.) Attendance Test will be: Attended by the customer Unattended by the customer FILE: EMCU_F09.02E, REVISION 1, Effective: 06 February 2001 Page 1 of 6

Form EMC Test Plan and Constructional Data Form Failure - Complete this section if testing will not be attended by the customer. If a failure occurs, TUV Product Service should: Call contact listed above, if not available then stop testing. (After hrs phone): Continue testing to complete test series. Continue testing to define corrective action. Stop testing. EUT Specifications and Requirements Length : see excel doc. Width: see excel doc. Height: see excel doc. Weight: see excel doc. Power Requirements Regulations require testing to be performed at typical power ratings in the countries of intended use. (i.e., European power is typically 230 VAC 50 Hz or 400 VAC 50 Hz, single and three phase, respectively) Voltage: 230 VAC (If battery powered, make sure battery life is sufficient to complete testing.) # of Phases: Single Current (Amps/phase(max)): 2A Current (Amps/phase(nominal)): 2A Other Other Special Requirements Typical Installation and/or Operating Environment (ie. Hospital, Small Business, Industrial/Factory, etc.) Office/Industrial - factory type environment EUT Power Cable Permanent OR Removable Length (in meters): Shielded OR Unshielded Not Applicable FILE: EMCU_F09.02E, REVISION 1, Effective: 06 February 2001 Page 2 of 6

Form EMC Test Plan and Constructional Data Form EUT Interface Ports and Cables Interface Shielding Type Type Termination EXAMPLE: RS232 2 Foil over braid Coaxial Connector Type Metallized 9- pin D-Sub Port Termination Characteristic Impedance 6 FILE: EMCU_F09.02E, REVISION 1, Effective: 06 February 2001 Page 3 of 6

Form EMC Test Plan and Constructional Data Form EUT Software. Revision Level: Description: Equipment Under Test (EUT) Operating Modes to be Tested -- list the operating modes to be used during test. It is recommended the equipment be tested while operating in a typical operation mode. FCC testing of personal computers and/or peripherals requires that a simple program generate a complete line of upper case H s. Provide a general description of all software, firmware, and PLD algorithms used in the equipment. List all code modules as described above, with the revision level used during testing. Consult with your TÜV Product Service Representative if additional assistance is required. 1. one mode of operation for all units - ON 2. 3. Equipment Under Test (EUT) System Components -- List and describe all components which are part of the EUT. For FCC testing a minimum configuration is required. (ie. Mouse, Printer, Monitor, External Disk Drive, Motherboard, etc.) Description Model # Serial # FCC ID # FILE: EMCU_F09.02E, REVISION 1, Effective: 06 February 2001 Page 4 of 6

Form EMC Test Plan and Constructional Data Form Support Equipment -- List and describe all support equipment which is not part of the EUT. (i.e. peripherals, simulators, etc) Description Model # Serial # FCC ID # Oscillator Frequencies Frequency Derived Frequency Component # / Location Description of Use Power Supply Manufacturer Model # Serial # Type Switched-mode: (Frequency) Linear Other: Switched-mode: (Frequency) Linear Other: Power Line Filters Manufacturer Model # Location in EUT See exel doc FILE: EMCU_F09.02E, REVISION 1, Effective: 06 February 2001 Page 5 of 6

Form EMC Test Plan and Constructional Data Form Critical EMI Components (Capacitors, ferrites, etc.) Description Manufacturer Part # or Value Qty Component # / Location See excel doc EMC Critical Detail -- Describe other EMC Design details used to reduce high frequency noise. (PLEASE INSERT ELECTRONIC SIGNATURE BELOW IF POSSIBLE) Authorization Signatures Customer authorization to perform tests according to this test plan. Date Test Plan/CDF Prepared By (please print) Date Reviewed by TÜV Product Service Associate Date FILE: EMCU_F09.02E, REVISION 1, Effective: 06 February 2001 Page 6 of 6

Model EUT Name EUT Description of Use Serial # Length Width Height Weight Power Line Filter EMI Components OD4012 OD4012 Punches holes in paper for different types of binding styles 1AC1005 18" 16" 6-1/5" 48 lbs Corcom #6EP1 Inductor RD5132-6-5MO Steward ferrite 28A2024-0A0 APES-14 APES-14 Paper Take-Away/ Stacking System XC1005 22" 38" 15" 55 lbs Qualtek 864-10/009 Steward ferrite 28B0686-200 CI4170 CI4170 Punches holes in paper for different types of binding styles ZC1001 10" 17" 5-1/2" 25 lbs. Qualtek 864-10/009 None HD7500 HD7500 Punches holes in paper for different types of binding styles 755024 16-3/4" 27" 8" 127LBS Corcom #6EP1 Inductor RD5132-6-5MO Steward ferrite 25B11142-000 HD6500 HD6500 Punches holes in paper for different types of binding styles 655043 16-3/4" 17" 8" 87LBS Qualtek 864-10/009 Corcom 6EHT1 Steward ferrite 28A2024-0A0 HD7000 HD7000 Punches holes in paper for different types of binding styles 705133 16-3/4" 17" 8" 87LBS Qualtek 864-10/009 Corcom 6EHT1 Steward ferrite 28A2024-0A0