KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Similar documents
Industrial 3-Port Fast Ethernet Media Converter Switches

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

KFC-200. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS. KC-300DM Series. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS EM4000 EM4001. Installation Guide

10/100BASE-TX TO 100BASE-FX MEDIA CONVERTERS

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

M727xS 10/100BaseTX-FX Selectable Media Converter Installation Guide

KSD-800M Industrial Managed 8-Port Fast Ethernet Switches with Fiber Connectivity Operation Manual

M727xSP. PoE Powered. Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX. Installation Guide

Modular 8-Port Mid-span Power over Ethernet Injector

SF7085xM. 8-Port 10/100 Industrial Managed Switch. Operation Manual. Rev. B

KPW-T2P25. PoE Splitter. Industrial IEEE 802.3at High Power. User s Manual -1- DOC

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Installation Guide. Web Smart Managed 10/100 Fast Ethernet Switches with VLAN Support

S7055xM / S7075xM Web Smart Managed 5-Port / 7-Port 10/100 Fast Ethernet Switch w/vlan Support Installation Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

KGS-510F Web Smart 6-Port Gigabit Ethernet Switch with Fiber Connectivity Installation Guide

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

KGD-600 Industrial Web Smart 6-Port Gigabit Ethernet Switch with Fiber Connectivity Installation Guide

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch. ISW-500T/ISW-800T User s Manual

XPress-Pro SW User Guide

KGC-310 / KGC-310M. Installation Guide. Web Smart Gigabit Ethernet Media Converter. F/W v1.03 up DOC

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

Quick Start Guide. Physical Description. The Port Status LEDs

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

KGD-600-B Industrial Web Smart 6-Port Gigabit Ethernet Switch with Fiber Connectivity Installation Guide

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Hardened PoE Ethernet Switch

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

LNX-0702G-SFP Series

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

LNP-0501 Series. User Manual. 5-Port Industrial PoE+ Unmanaged Ethernet Switches with 4*10/100Tx (30W/Port) + 1*10/100Tx

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

IMC-21A Quick Installation Guide

IMC-21 Quick Installation Guide

USER S MANUAL. 10/100/1000Base-T 1000Base-SX/LX Gigabit Ethernet Converter GEP-5300TF-C GEP-5400TF-C

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

Industrial Ethernet Switch

LevelOne FSW PoE Fast Ethernet Switch User Manual

HES-3106-PLUS SERIES

Rugged Industrial Media Converter

Industrial PoE Media Converter

IMC-21GA Quick Installation Guide

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

PTC-101 Quick Installation Guide

XPress-Pro SW User Guide

LNX-1002C-SFP Series

Table of Contents... 1 Packing List... 2 FCC Statement... 2 Introduction Product Features... 3 Front Panel... 3 LEDs Installation...

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Fast Ethernet Converter. User Guide MICROSENS

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

IFS MC201-1P/1FS User Manual

Installation Guide 24-port 10/100 Fast Ethernet Switch with 1 Fiber Connection Model Name: KS-324F

PTC-101-M12 Hardware Installation Guide

gigabit industrial ethernet user manual Models , ,

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

FRG-3105 Series Residential Gateway

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

Switch manual Models &

BLACKBOX NETWORK SERVICES. one source for worldwide infrastructure services

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

FWRIII-2105 SERIES. 4 ports 10/100Mbps RJ-45; built-in IEEE802.11n WiFi and 1 port 100Mbps SFP slot uplink Residential Gateway. Residential Gateway

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

Hardened Media Converter

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

5-Port 10/100Mbps with 4-Port PoE. Industrial Fast Ethernet Switch ISW-504PT / ISW-514PT / ISW-514PT15 / ISW-514PTF. User's Manual

24-Port Gigabit Ethernet Switches

5/8-Port 10/100/1000Mbps. Industrial Gigabit Ethernet Switch IGS-501 / IGS-801 / IGS-501T / IGS-801T. User's Manual

IMC-P111FX Series IMC-P111P Series

Raven Series Standalone Media Converters

Industrial 8-Port 10/100TX Compact Ethernet Switch

EKI-7526I 16 Port Unmanaged Industrial Ethernet Switch. User Manual

10/100Base-TX to 100Base-TX Mini Converter. Operation Manual

Perle Gigabit Media Converter Module. Installation Guide P/N

Transcription:

KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1-

(C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without permission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc. to provide notification of such revision or change. For more information, contact: United States KTI Networks Inc. P.O. BOX 631008 Houston, Texas 77263-1008 Phone: 713-2663891 Fax: 713-2663893 E-mail: kti@ktinet.com URL: http://www.ktinet.com/ International Fax: 886-2-26983873 E-mail: kti@ktinet.com.tw URL: http://www.ktinet.com.tw/ -2-

The information contained in this document is subject to change without prior notice. Copyright (C). All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. WARNING: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference in which case the user will be required to correct the interference at his own expense. NOTICE: (1) The changes or modifications not expressively approved by the party responsible for compliance could void the user's authority to operate the equipment. (2) Shielded interface cables and AC power cord, if any, must be used in order to comply with the emission limits. CISPR A COMPLIANCE: This device complies with EMC directive of the European Community and meets or exceeds the following technical standard. EN 55022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment. This device complies with CISPR Class A. WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community. Such marking is indicative that this equipment meets or exceeds the following technical standards: EN 55022: Limits and Methods of Measurement of Radio Interference characteristics of Information Technology Equipment. EN 50082/1:Generic Immunity Standard -Part 1: Domestic Commercial and Light Industry. EN 60555-2: Disturbances in supply systems caused by household appliances and similar electrical equipment - Part 2: Harmonics. -3-

Table of Contents 1. Introduction... 5 1.1 Features...6 1.2 Product Panels...6 1.3 Front Panel...7 1.4 Network Ports...7 1.5 LED Indicators...8 1.6 Top Panel...9 1.7 Bottom Panel...9 1.8 Specifications...10 1.9 Model Definitions...12 2. Installation... 14 2.1 Unpacking... 14 2.2 Safety Cautions... 14 2.3 DIN-Rail Mounting... 15 2.4 Panel Mounting...16 2.5 Applying Power...18 2.6 Power Failure Relay Output...19 2.7 Reset Button... 20 2.8 Selecting UTP or Fiber... 20 2.9 Making UTP Connections... 21 2.10 Making Fiber Connections... 22 2.11 LED Indication...23-4-

1. Introduction The KSD-800 series is 8-port full wire speed Fast Ethernet switches for industrial applications. Depending on the fiber connectivity, the series is provided in three types of configuration as follows: Model series 10/100TX TP Ports 100FX fiber ports 800 8 ports - 800-1xxx 8 ports 1 port 800-2xxx 8 ports 2 ports The switches provide the following advantages: Plug and Play The switches provide eight 10/100TX copper ports for connections to Ethernet devices or 100Mbps Fast Ethernet devices. With the featured auto-negotiation function, the switches can detect and configure the connection speed and duplex automatically. The switches also provide auto MDI/MDI-X function, which can detect the connected cable and switch the transmission wire pair and receiving pair automatically. This auto-crossover function can simplify the type of network cables used. Selectable Copper/Fiber Connections The 100FX fiber ports can support 100Mbps fiber connection using optic fiber cable and extend a network connection up to several kilometers via fiber cables. The 100TX ports are designed to share the same switched ports with the associated 10/100TX copper ports. It means the switched port supports dual network media types, either copper cable or fiber cable. Designed for Industrial Applications For industrial environment, the switches are designed with the following enhanced features: High and wide operating Temperature Wide operating voltage range for DC power input Power input interface: Screw terminal block and DC jack for adapter Relay output for device power failure alarm DIN rail mounting support for industrial enclosure Panel mounting support for industrial enclosure -5-

1.1 Features Fast Ethernet switch with 8 10/100TX copper ports Auto MDI/MDI-X detection on all 10/100TX ports Auto-negotiation capable on all 10/100TX ports 100FX slots support wide range of fiber options - ST, SC connectors - Multi-mode fiber, Single mode duplex fiber Far End Fault function on 100FX ports Back pressure flow control for half duplex operation IEEE 802.3x flow control for full duplex operation Broadcast storm protection function Provides comprehensive LED indication Support DIN-rail and panel mounting 1.2 Product Panels The following figure illustrates three major panels of model 800-2 series as example: -6-

1.3 Front Panel The figure below shows the individual front panel of three model series. The main difference is the number of the equipped fiber ports. 1.4 Network Ports Model 800 provides eight 10/100TX copper ports only. No fiber connectivity is equipped. -7-

Model 800-1 series provide eight 10/100TX copper ports and one 100FX fiber connector on Port 8. Model 800-2 series provide eight 10/100TX copper ports and one 100FX fiber connector on Port 7 and Port 8 respectively. 1.5 LED Indicators LED Function PWR Power status LNK Network port link status (per port) 100M Network port speed status (per port) FX7 Fiber port link status (if fiber port is equipped on Port 7) FX8 Fiber port link status (if fiber port is equipped on Port 8) Mgt. Factory reserved -8-

1.6 Top Panel All three model series provide same top panel as figure shown below: The main functions are: DC Power Jack Terminal Block Reset This connector is used when a AC-DC power adapter is used as a power source to the switch. This connector provides the following interfaces: DC1 Positive(+) and Negative(-) - VDC power input from power system DC2 Positive(+) and Negative(-) - VDC power cascaded to next device PF Positive(+) and Negative(-) - Power failure relay output Hardware reset push button 1.7 Bottom Panel All three model series provide same bottom panel as figure shown below: The switch block SW is used for selecting the media connector type for Port 7 and Port 8. Model SW ON Position OFF Position 800 SW1 - Reserved SW2 - Reserved 800-1 SW1 - Reserved SW2 Select FX8 Select 10/100TX RJ-45 TP8 800-2 SW1 Select FX7 Select 10/100TX RJ-45 TP7 SW2 Select FX8 Select 10/100TX RJ-45 TP8-9-

1.8 Specifications Network Ports Switched Port Number Model 800 800-1 series 800-2 series Port 1 10/100TX 10/100TX 10/100TX Port 2 10/100TX 10/100TX 10/100TX Port 3 10/100TX 10/100TX 10/100TX Port 4 10/100TX 10/100TX 10/100TX Port 5 10/100TX 10/100TX 10/100TX Port 6 10/100TX 10/100TX 10/100TX Port 7 10/100TX 10/100TX 10/100TX 100FX Port 8 10/100TX 10/100TX 10/100TX 100FX 100FX Note: 10/100TX - TP RJ-45, 100FX - Fiber 10/100TX Twisted Pair Ports (TP) Compliance IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX Connectors Shielded RJ-45 jacks Pin assignments Auto MDI/MDI-X detection Configuration Auto-negotiation Transmission rate 10Mbps, 100Mbps Duplex support Full/Half duplex Flow control IEEE 802.3x pause frame base for full duplex operation Back pressure for half duplex operation Network cable Cat.5 UTP 100FX Fiber Ports Compliance Configuration Transmission rate Far end fault function IEEE 802.3u 100BASE-FX Forced 100Mbps, Full duplex 100Mbps Capable to receive FEFI (far end fault indication) signal Capable to send FEFI signal when Rx link failure detected Flow control IEEE 802.3x pause frame base for full duplex operation Back pressure for half duplex operation Network cables MMF 50/125 60/125, SMF 9/125 Eye safety IEC 825 compliant Optical Specifications Refer to Section 1.9. -10-

Switch Functions MAC Addresses Table 1K entries Forwarding & filtering Non-blocking, full wire speed 10Mbps - 14,880 pps at 64-byte packets 100Mbps - 148,800pps at 64-byte packets Switching technology Store and forward Maximum packet length 1536 bytes Broadcast storm 64 consecutive broadcast packets in 800ms Protection by dropping broadcast storm packets LED Indicators System Per 10/100TX port Per 100FX port Power status TP port link/activity status, speed status FX port link status DC Power Input Interfaces Euro type terminal block contacts (DC1 DC2 : 2 sets for power wire cascading) DC Jack ( -D 6.3mm / + D 2.0mm) Operating Input Voltages +7V ~ +30V(+5%) Power consumption Model 800 4.7W/7.5VDC input, 5.0W/30VDC input Model 800-1 5.3W/7.5VDC input, 5.6W/30VDC input Model 800-2 7.1W/7.5VDC input, 7.3W/30VDC input Mechanical Dimension (base) 140 x 106 x 40 mm Housing Enclosed metal with no fan Mounting Support DIN-rail mounting, Panel mounting Weight Model 800 455g, Model 800-1 465g, Model 800-2 475g Environmental Operating Temperature Typical -20 o C ~ 70 o C Storage Temperature -20 o C ~ 85 o C Relative Humidity 5% ~ 90% Electrical Approvals FCC CE Part 15 rule Class A EMC, CISPR22 Class A -11-

1.9 Model Definitions KSD-800-xxx Wavelength Reference Operating Model Ext.FX Connectors (nm) Fiber Distance Temperature -1T FX8 : ST MMF 1310 2 km -10 ~ 70 o C -1C FX8 : SC MMF 1310 2 km -10 ~ 70 o C -1SL2 FX8 : SC SMF 1310 20 km -20 ~ 70 o C -1SL3 FX8 : SC SMF 1310 30 km -20 ~ 70 o C -1SL4 FX8 : SC SMF 1310 40-50 km -20 ~ 70 o C -2T FX7 : ST MMF 1310 2 km -10 ~ 70 o C FX8 : ST MMF 1310 2 km -10 ~ 70 o C -2C FX7 : SC MMF 1310 2 km -10 ~ 70 o C FX8 : SC MMF 1310 2 km -10 ~ 70 o C -CSL2 FX7 : SC MMF 1310 2 km -20 ~ 70 o C FX8 : SC SMF 1310 20 km -20 ~ 70 o C -2SL2 FX7 : SC SMF 1310 20 km -20 ~ 70 o C FX8 : SC SMF 1310 20 km -20 ~ 70 o C -2SL3 FX7 : SC SMF 1310 30 km -20 ~ 70 o C FX8 : SC SMF 1310 30 km -20 ~ 70 o C -2SL4 FX7 : SC SMF 1310 40-50 km -20 ~ 70 o C FX8 : SC SMF 1310 40-50 km -20 ~ 70 o C -12-

Optical Specifications KSD-800-xxx WaveL. TX Power Rx Sens. Rx max. Model Ext.FX Connectors (nm) (dbm) (dbm) (dbm) -1T FX8 : ST MMF 1310-20 ~ -14-32 max. -8 min. -1C FX8 : SC MMF 1310-20 ~ -14-31 max. 0 min. -1SL2 FX8 : SC SMF 1310-15 ~ -8-30 max. -7 min. -1SL3 FX8 : SC SMF 1310-15 ~ -8-34 max. 0 min. -1SL4 FX8 : SC SMF 1310-5 ~ 0-35 max. -3 min. -2T FX7 : ST MMF 1310-20 ~ -14-32 max. -8 min. FX8 : ST MMF 1310-20 ~ -14-32 max. -8 min. -2C FX7 : SC MMF 1310-20 ~ -14-31 max. 0 min. FX8 : SC MMF 1310-20 ~ -14-31 max. 0 min. -CSL2 FX7 : SC MMF 1310-20 ~ -14-31 max. 0 min. FX8 : SC SMF 1310-15 ~ -8-30 max. -7 min. -2SL2 FX7 : SC SMF 1310-15 ~ -8-30 max. -7 min. FX8 : SC SMF 1310-15 ~ -8-30 max. -7 min. -2SL3 FX7 : SC SMF 1310-15 ~ -8-34 max. 0 min. FX8 : SC SMF 1310-15 ~ -8-34 max. 0 min. -2SL4 FX7 : SC SMF 1310-5 ~ 0-35 max. -3 min. FX8 : SC SMF 1310-5 ~ 0-35 max. -3 min. WaveL. : Wavelength, Rx Sens. : Rx sensitivity, Rx max. : Maximum Rx power -13-

2. Installation 2.1 Unpacking The product package contains: The switch unit One DIN-rail mounting kit One product CD-ROM 2.2 Safety Cautions To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the following precautions. Do not service any product except as explained in your system documentation. Opening or removing covers may expose you to electrical shock. Only a trained service technician should service components inside these compartments. If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your trained service provider: - The power cable, extension cable, or plug is damaged. - An object has fallen into the product. - The product has been exposed to water. - The product has been dropped or damaged. - The product does not operate correctly when you follow the operating instructions. Do not push any objects into the openings of your system. Doing so can cause fire or electric shock by shorting out interior components. Operate the product only from the type of external power source indicated on the electrical ratings label. If you are not sure of the type of power source required, consult your service provider or local power company. -14-

2.3 DIN-Rail Mounting In the product package, a DIN-rail bracket is provided for mounting the switch in a industrial DIN-rail enclosure. The steps to mount the switch onto a DIN rail are: 1. Install the mounting bracket onto the switch unit as shown below: 2. Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail. 3. Clamp the unit to the DIN rail and make sure it is mounted securely. -15-

2.4 Panel Mounting The switches are provided with an optional panel mounting bracket. The bracket support mounting the switch on a plane surface securely. The mounting steps are: 1. Install the mounting bracket on the switch unit. 2. Screw the bracket on the switch unit. -16-

3. Screw the switch unit on a panel. Three screw locations are shown below: -17-

2.5 Applying Power The power specifications of the switch are: Operating Voltage Power Consumption +7 ~ +30VDC Max. 7.3W @30VDC The switch provides two types of power interfaces, terminal block and DC power jack for receiving DC power input from external power supply. Using Terminal Blocks Either DC1 interface or DC2 interface can be used to receive DC power from an external power system. Or, DC2 also can be used to deliver the power received on DC1 to next switch in cascading way. DC1 + DC1 - DC2 + DC2 - Vdc Positive (+) terminal Vdc Negative (-) terminal Vdc Positive (+) terminal Vdc Negative (-) terminal Three 2P terminal plugs are provided together with the switch. Two of the three plugs are used for DC1 and DC2 interfaces respectively. The plug is shown below: Power wires : 24 ~ 12AWG (IEC 0.5~2.5mm 2 ) Install the power source wires with the plug properly. Then, plug in DC1 contacts. If cascading the power to next switch device is needed, install the power wires and plug for another switch. Then, use DC2 contacts. Note: Only up to four device units can be cascaded to receive power from one main power input source. -18-

Using DC Power Jack When an external power system is not available, the switch provides a DC jack to receive power from typical AC-DC power adapter alternatively. AC Power Adapters: Optional commercial rated adapters are available for purchasing. Rated AC120V/60Hz DC7.5V 1A Rated AC230V/50Hz DC7.5V 1A Rated AC100V/50-60Hz DC7.5V 1A Rated AC240V/50Hz DC7.5V 1A Note: Before you begin the installation, check the AC voltage of your area. The AC power adapter which is used to supply the DC power for the unit should have the AC voltage matching the commercial power voltage in your area. 2.6 Power Failure Relay Output The switch provides a relay output to report power failure event to a remote alarm monitoring system. The replay output is provided with two contacts in the terminal block next DC2 interface. Use the provided 2P terminal plug for signal wiring and plug into the PF+/- contacts. The function is designed as : Power is normal Power failure PF+ contact is shorted with PF- contact. PF+ contact is disconnected with PF- contact. Note: Be sure the voltage applied on PF+/- contacts is within the specification of 30VDC/1A max. or 120VAC/0.5A max. -19-

2.7 Reset Button The reset button is used to perform a hardware reset to the switch. It is not used in normal cases and can be used for diagnostic purpose. If any network hanging problem is suspected, it is useful to push the button to reset the switch without turning off the power. Check whether the network is recovered. 2.8 Selecting UTP or Fiber If the switch is equipped with FX7 port or FX8 port, it is required to select the media type to be used for the switched Port 7 and Port 8. Set the setting SW which is located on bottom panel to make the selection. Model SW ON Position OFF Position 800 SW1 - Reserved SW2 - Reserved 800-1 SW1 - Reserved SW2 Select FX8 Select 10/100TX RJ-45 TP8 800-2 SW1 Select FX7 Select 10/100TX RJ-45 TP7 SW2 Select FX8 Select 10/100TX RJ-45 TP8 Note: Do not change the reserved states specified in the above table. -20-

2.9 Making UTP Connections The 10/100TX ports supports the following connection types and distances: Network Cables 10BASE-T: 100BASE-TX: Link distance: 2-pair UTP Cat. 3,4,5, EIA/TIA-568B 100-ohm 2-pair UTP Cat. 5, EIA/TIA-568B 100-ohm Up to 100 meters The ports are equipped with auto MDI/MDI-X function and auto-negotiation function for the UTP connection. Auto MDI/MDI-X Function This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid MDI to MDI-X connection with the remote connected device automatically. No matter a straight through cable or crossover cable is connected, the ports can sense the receiving pair automatically and configure itself to match the rule for MDI to MDI-X connection. It simplifies the cable installation. Auto-negotiation Function The ports are featured with auto-negotiation function and full capability to support connection to : Auto-negotiation devices Auto-negotiation incapable 10BASE-T devices Auto-negotiation incapable 100BASE-TX devices It performs a negotiation process for the speed and duplex configuration with the connected device automatically when each time a link is being established. If the connected device is also auto-negotiation capable, both devices will come out the best configuration after negotiation process. If the connected device is incapable in auto-negotiation, the switch will sense the speed and use half duplex for the connection. -21-

2.10 Making Fiber Connections FX7 port and FX8 port operate on 100Mbps and full duplex. The following figure illustrates a connection example between two fiber ports: Make sure the Rx-to-Tx connection rule is followed on the both ends of the fiber cable. Far End Fault Function The FX ports are facilitated with this function, which conforms to IEEE 802.3u 100BASE-FX specifications. When the FX port detects a link failure on its receiving circuitry, it will send out an FEFI (Far End Fault Indication) signal to the remote connected device to indicate a remote fault is detected. It also is capable to receive FEFI signal sent from the remote link partner. Upon receiving an FEFI signal, it indicates a link failure occurred on the transmitting path. This function allows the switch to report a fiber link fault even when a link failure occurred on transmitting fiber cable. Network Cables Multimode (MMF) - 50/125, 62.5/125 Single mode (SMF) - 9/125-22-

2.11 LED Indication LED Function State Interpretation PWR Power status ON The power is supplied to the switch. OFF The power is not supplied to the switch. LNK Port link status ON An active link is established on the port. (No traffic) BLINK Port link is up and there is traffic. OFF Port link is down. 100M Port speed status ON 100Mbps OFF 10Mbps FX7 FX7 link status ON FX7 port is link up. BLINK Port link is up and there is traffic. OFF Port link is down. FX8 FX8 link status ON FX8 port is link up. BLINK Port link is up and there is traffic. OFF Port link is down. Mgt. Factory Reserved Ignore the indication. Note: FX7 LED is reserved and can be ignored for Model 800 and Model 800-1 series. FX8 LED is reserved and can be ignored for Model 800. -23-