SINGLEstream Link Aggregation Tap (SS-100)

Similar documents
Ixia xbalancer. A Purpose-Built Load Balancer for 10G Networks. The Load Balancing Solution DATA SHEET. Highlights

Smart Network Access System

Ixia Net Optics ilink Agg xstream

TS-1404, TS-1406, TS G Aggregation Taps

Ixia Net Optics ibypass 1Gb Fiber

Ixia Net Optics Flex Tap TM

Summit Virtual Chassis Design and Installation Guide

SS-1200 Series Link Aggregating Taps. SS-2200 Series Dual-Link Aggregating Tap. VS-1200 Series Link Regenerator/Aggregator

GigaVUE-420 Specifications

Network Packet Brokers FASTstart Guide

New Product: Cisco Catalyst 2950 Series Fast Ethernet Desktop Switches

GigaVUE-2404 // Data Sheet

Cubro 10/100/1000 Copper TAP

MX Ring. WDM - MUX/DeMUX. MUX/DeMUX. Features Full native mode performance Optical connectors Passive model requires no power.

GigaVUE-420 // Data Sheet

10/100/1000, 10G & 40G

IXIA IBYPASS HD DATA SHEET PROBLEM: INLINE TOOLS ARE A SINGLE POINT OF FAILURE IN THE NETWORK

Cubro 10/100/1000 Copper TAP

Ixia xstream TM 10. Aggregation, Filtering, and Load Balancing for 1GbE/10GbE Networks. Aggregation and Filtering DATA SHEET

Datasheet. Gigabit Passive Optical Network. Models: UF-OLT, UF-OLT-4, UF-Nano, UF-LOCO. GPON End-to-End Solution. High-Performance, Provider OLT

Installation Guide for Fiber Tap HD8

The Conversion Technology Experts. Choosing a Fast Ethernet Media Converter

FMUX1001 Modularized 16E1/T1 + 4x GbE Managed Fiber Multiplexer FMUX101 Modularized 16E1/T1 + 4x FE Managed Fiber Multiplexer

Datasheet. Gigabit Passive Optical Network. Models: UF-OLT, UF-Nano, UF-LOCO. GPON End-to-End Solution. High-Performance, Provider OLT

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

5U CWDM Managed Platform SML-5000

Brochure. ION Multi-Service Integration Platform. Integrate. Optimize. Navigate. Transition Networks Brochure.

Save installation time and money with PoE.

4 PWR XL: Catalyst 3524 PWR XL Stackable 10/100 Ethernet

C Mb Ethernet Copper Tap

Anue Net Tool Optimizer 5273

Datasheet. 10G 16-Port Managed Aggregation Switch. Model: US-16-XG. Non-Blocking Throughput Switching. Maximum Performance and Low Latency

GigaVUE-2404 // Data Sheet

C1-1G Single Port Copper Tap

Gigabit Ethernet Fiber Media Converter - Compact - 850nm MM LC - 550m

Datacom Systems Inc. SS G(-F) Aggregation Taps USERguide. Access Your Network TM SS-1204LR-10G SS-1204SR-10G SS-1214LX-10G SS-1214SX-10G

Ixia Flex Tap PASSIVE NETWORK MONITORING HIGHLIGHTS KEY FEATURES. Data Sheet

Ref: C8-1G. The 8-Link Gigabit Copper TAP is a high density solution, providing 8 TAP links in a 1U rack space

Datasheet. 10G 16-Port Managed Aggregation Switch. Model: US-16-XG. Non-Blocking Throughput Switching. Maximum Performance and Low Latency

Cisco DCM Series D9901 Digital Content Manager IP Video Gateway

Installing the IPS 4345 and IPS 4360

2015 Product Catalog

Datasheet Gigabit Passive Optical Network Models: UF-OLT, UF-Nano GPON End-to-End Solution High-Performance, Provider OLT Low-Cost, Robust ONU CPE

PE2G4SFPI80 Quad Port SFP Gigabit Ethernet PCI Express Server Adapter Intel 82580EB Based

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X FE/GbE Media Converter Concentrator

Gigabit Ethernet Fiber Media Converter with Open SFP Slot

PHB-200M PHB x 100/1000Base-T to 20x 100/1000Base-X

FVT Slot Media Converter Chassis w/ Redundant Power User Manual

Cisco Series Gigabit Ethernet Half-Height Line Card

Cisco 100 Series Unmanaged Switches Cisco Small Business

Extended Managed Ethernet Switch - 8 Ports

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

QUICK START GUIDE 7000 SERIES DEVICES. 3D7010/7020/7030 (Chassis: CHRY-1U-AC) 3D7115/7125, AMP7150 (Chassis: GERY-1U-4C8S-AC)

Datasheet Gigabit Passive Optical Network Models: UF-OLT, UF-Nano GPON End-to-End Solution High-Performance, Provider OLT Low-Cost, Robust ONU CPE

Switch manual Models &

CVH Slot Media Converter Chassis Quick Installation Guide

MEDIA CONVERTERS AND CHASSIS

ProCurve Switch 1400 Series

Media Converters & Chassis

SUN BLADE 6000 VIRTUALIZED 40 GbE NETWORK EXPRESS MODULE

Industrial Gigabit Managed Ethernet Switch

OmniConverterTM. OmniConverter GPoE+/Sx KEY FEATURES. Unmanaged 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

V C ALIANT OMMUNICATIONS. VCL-Gigabit Optical Add-Drop Multiplexer. Product Brochure U.S.A. U.K. INDIA

USER guide. Datacom Systems Inc. FVS-1044 Data Access Switch. FVS-1080 Data Access Switch. Access Your Network TM. May U-B.

IEC /IEEE 1613 Lite L3 Hardened Managed 24-port Gigabit SFP. 10GbE Connectivity Four 10G SFP+ for connecting the switch to the core network

308FX2-N. Phone: Fax: Web:

Maximizing visibility for your

Product Overview. Switch Models CHAPTER

FOM-FXO32 / FOM-FXS32 32 Voices (FXS/FXO) POTS Fiber Multiplexer

alliedtelesis.com/products

FlowDirector x 1G//10G SFP/SFP+ Ports Network Fabric Visibility Appliance

IXIA FLEX TAP TM DATA SHEET PASSIVE NETWORK MONITORING KEY FEATURES HIGHLIGHTS

Installation Manual. Table of Contents

Perle 10GT Media Converters

FlowDirector x 1G/2.5G/10G SFP/SFP+ and 4x 40Gb QSFP+ Ports Network Fabric Visibility Appliance

QUICK START GUIDE 7000 SERIES DEVICES

ETHERNET FIBER OPTIC CONVERTERS

QuickSpecs. Models HP TippingPoint S8010F Next Generation Firewall Appliance

Industrial 10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Managed Ethernet Switches

SECURE 6. Secure64 Appliances Purpose-built DNS appliances for the most demanding environments DNS APPLIANCES DATA SHEET. Appliance Descriptions

Key Benefits Ixia xstreamtm 40 Fail -safe Inline Security NPB Offers Aggregation, Filtering, and Load Balancing for 10GbE/40GbE Networks

HARTING econ 3000 Introduction and features

3299 Rack Mount. Product Highlights. Multifunctional BypassP 2 Segment. Switching Fabric

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

JPEG p Low Latency Video over IP Encoder with KVM, PoE, SFP, HDMI NMX-ENC-N2135 (FGN2135-SA), Stand Alone NMX-ENC-N2135-C (FGN2135-CD), Card

Optical Networking. Applications

OmniConverterTM. OmniConverter FPoE/SL, FPoE/S and FPoE+/S 10/100 Media Converter with Power over Ethernet (PoE or PoE+) KEY FEATURES

317FX-N. Phone: Fax: Web: -

INSTRUCTION MANUAL FMX-GE-1000 ETHERNET TO OPTICAL MEDIA CONVERTER

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

Industrial Switches Industrial Switches

IS100 Silicom 100G Intelligent Bypass Switch

RGS-7244GP / RGS-7244GP-E

Save installation time and money with PoE. Power over Ethernet 802.3at

Save installation time and money with PoE.

Standalone or rackmounted

Gigabit Desktop. manual Models & Model shown: INT / UM

Optimux-34, Optimux-25

Transcription:

SINGLEstream Link Aggregation Tap (SS-00) Optional 3-Unit Rack Mount Datacom Systems SINGLEstream 0/00 Link Aggregation Tap provides a superior solution for 4x7 monitoring of full-duplex Ethernet links. While traditional 0/00 taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the monitoring device (e.g. analyzer, IDS, probe) in two separate half-duplex streams. Not only does this require the monitoring device to have two network interface cards (NIC), it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring devices have that capability. The SINGLEstream Link Aggregation Tap faultlessly combines the two data streams, allowing any connected monitoring device to receive a full-duplex stream of data with one NIC. Connect any compatible device (protocol analyzers, probes, intrusion detection system, more) for permanent In-Line monitoring of full-duplex links - eliminates the need for network connectors to be disconnected and connected each time a segment needs to be monitored Two monitor ports allow two devices to simultaneously monitor the same link, providing extended security and analysis options, while eliminating contention for network access Redundant power supply insures seamless monitoring even if the main power source is unavailable Never lose packets from power failure - industry-leading no break the link design guarantees network traffic will continue to flow uninterrupted* Simple plug-and-play solution - requires no additional configuration of external monitoring devices Supports Power over Ethernet (PoE) Optional TCP Resets Available * SS-00 and SS-0 Models Ports T e c h n i c a l S p e c i f i c at i o n s One () 0/00 (RJ45) Network Connection Two () 0/00 (RJ45) Tap/Monitoring Connections Power Requirements Two () (External AC Adapters Included) Input: 00-40 VAC, 50-60 Hz, 0.4A - 0.A Output: 5 VDC, A Physical Dimensions (H x W x D).07 x 5 x 5 in.7 x.7 x.7 cm Weight oz..34 kgs. Environmental Operating Temperature: 0 to 40 C Storage Temperature: -30 to 65 C Humidity: Less than 95 C Non-Condensing Warranty -Year Limited Warranty Ordering Information Port In: Port Out: SS-00-0/00-0/00 SS-0-00MB - 00MB SS-0** - 0/00-0/00 SS-03** - 00MB - 00MB ** Includes TCP Resets RMC-3 RMC-4 3 - Unit U Rack Mount Chassis 4 - Unit 4U Rack Mount Chassis ACCESS YOUR NETWORK 9 Adler Drive East Syracuse, NY 3057 T: (35) 463-954 F: (35) 463-9557 DatacomSystems.com Datacom Systems Inc. Copyright 99-007. All rights reserved.

You Can t Monitor What You Can t See SINGLEstream Dual Link Aggregation Tap (SX) with 6 - SFP Monitoring Ports SS-0SX-SFP Full-Duplex Visibility for Two () In-Line Network Links even with Single Interface Monitoring Solutions Aggregation Monitoring full duplex network traffic from multiple sources is often a critical requirement for network monitoring applications. For example, in order to properly monitor redundant networks or a pair of load balanced links, network professionals might need to receive traffic simultaneously from two different network segments. In some cases, two network links may be bound together and operate as one logical network in order to improve bandwidth. In such an implementation, packets are distributed across two different physical links. Often, traffic transmits on one segment and receives on another. This makes network analysis and monitoring especially challenging. If an analyzer or monitoring device is put on only one physical link, it will not see the entire conversation Also, while traditional taps might enable fullduplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems have the required hardware to aggregate traffic. The SINGLEstream Dual Link Aggregation Tap has two () network taps. Each tap combines both directions of a full duplex data stream and allows connected monitoring devices, even those with only one NIC, to receive a copy of all the data collected from both taps in a single trace file. Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-0SX-SFP s six (6) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. Benefits View entire full-duplex conversations even across redundant or load balanced links using single-interface monitoring tools Save money by reducing number of required tools or tool interfaces necessary to monitor all your data Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Single point of deployment and remote management minimizes management expenses and reduces MTTR Automatic coverage of redundant network - One tool can monitor two networks Features Aggregation - Receive copies of multiple network links or channels into one stream for visibility into complete network conversations 00% Network Uptime - Multi-mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Monitoring Port Speeds from 0 to 000MB; full duplex, half duplex, or auto-negotiate SFP Flexibility - monitor fiber links with copper tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Dual Link Aggregation Tap (SX) with 6 - SFP Monitoring Ports SS-0SX-SFP SS-0BT-BT/SFP Shown SS-0SX-SFP SS-0BT-BT/SFP www.datacomsystems.com 3 4 5 6 7 8 9 0 Power LEDs SX Tap SFP Monitor Ports SX Tap Management Port Network A Data Recorder 3 4 5 6 7 8 9 0 Network B Application Performance Monitor Technical Specifications - VS-4-0G SS-0SX-SFP PORTS Network: Two () Duplex LC Multi-Mode Taps (50 or 6.5 Micron) Monitoring: Six (6) SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-0SX-SFP SX SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Dual Link Aggregation Tap (SX) with 6 - SFP Monitoring Ports Specify 50 or 6.5 Micron SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 3

You Can t Monitor What You Can t See SINGLEstream Dual Link Aggregation Tap (SX) with - SFP Monitoring Ports SS-06SX-SFP Achieve Full-Duplex Visibility for Two () In-Line Network Links even with Single Interface Monitoring Solutions Aggregation Monitoring full duplex network traffic from multiple sources is often a critical requirement for network monitoring applications. For example, in order to properly monitor redundant networks or a pair of load balanced links, network professionals might need to receive traffic simultaneously from two different network segments. In some cases, two network links may be bound together and operate as one logical network in order to improve bandwidth. In such an implementation, packets are distributed across two different physical links. Often, traffic transmits on one segment and receives on another. This makes network analysis and monitoring especially challenging. If an analyzer or monitoring device is put on only one physical link, it will not see the entire conversation Also, while traditional taps might enable fullduplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems have the required hardware to aggregate traffic. The SINGLEstream Dual Link Aggregation Tap has two () network taps. Each tap combines both directions of a full duplex data stream and allows connected monitoring devices, even those with only one NIC, to receive a copy of all the data collected from both taps in a single trace file. Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. While some copper Gigabit taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other, the passive nature of optical fiber also eliminates this possibility of network failure. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. 4 Benefits View entire full-duplex conversations even across redundant or load balanced links using single-interface monitoring tools Save money by reducing number of required tools or tool interfaces necessary to monitor all your data Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Single point of deployment and remote management minimizes management expenses and reduces MTTR Automatic coverage of redundant network - One tool can monitor two networks Features Aggregation - Receive copies of multiple network links or channels into one stream for visibility into complete network conversations 00% Network Uptime - Multi-mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Monitoring Port Speeds from 0 to 000MB; full duplex, half duplex, or auto-negotiate SFP Flexibility - monitor fiber links with copper tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Dual Link Aggregation Tap (SX) with - SFP Monitoring Ports SS-06SX-SFP SS-06BT-SFP Shown SS-06SX-SFP SS-06BT-SFP ww w.datacomsystems.com 34 56 Power LEDs SX Tap SFP Monitor Ports SX Tap Management Port Network A 3 4 5 6 Tools Network B Technical Specifications - VS-4-0G SS-06SX-SFP PORTS Network: Two () Duplex LC Mult-Mode Taps (50 or 6.5 Micron) Monitoring: Two () SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-06SX-SFP SX SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Dual Link Aggregation Tap (SX) with - SFP Monitoring Ports Specify 50 or 6.5 Micron SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 5

You Can t Monitor What You Can t See SINGLEstream Dual Link Aggregation Tap (LX) with - SFP Monitoring Ports SS-06LX-SFP Achieve Full-Duplex Visibility for Two () In-Line Network Links even with Single Interface Monitoring Solutions Aggregation Monitoring full duplex network traffic from multiple sources is often a critical requirement for network monitoring applications. For example, in order to properly monitor redundant networks or a pair of load balanced links, network professionals might need to receive traffic simultaneously from two different network segments. In some cases, two network links may be bound together and operate as one logical network in order to improve bandwidth. In such an implementation, packets are distributed across two different physical links. Often, traffic transmits on one segment and receives on another. This makes network analysis and monitoring especially challenging. If an analyzer or monitoring device is put on only one physical link, it will not see the entire conversation Also, while traditional taps might enable fullduplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems have the required hardware to aggregate traffic. The SINGLEstream Dual Link Aggregation Tap has two () network taps. Each tap combines both directions of a full duplex data stream and allows connected monitoring devices, even those with only one NIC, to receive a copy of all the data collected from both taps in a single trace file. Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. While some copper Gigabit taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other, the passive nature of optical fiber also eliminates this possibility of network failure. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. 6 Benefits View entire full-duplex conversations even across redundant or load balanced links using single-interface monitoring tools Save money by reducing number of required tools or tool interfaces necessary to monitor all your data Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Single point of deployment and remote management minimizes management expenses and reduces MTTR Automatic coverage of redundant network - One tool can monitor two networks Features Aggregation - Receive copies of multiple network links or channels into one stream for visibility into complete network conversations 00% Network Uptime - Single mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Monitoring Port Speeds from 0 to 000MB; full duplex, half duplex, or auto-negotiate SFP Flexibility - monitor fiber links with copper tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Dual Link Aggregation Tap (LX) with - SFP Monitoring Ports SS-06LX-SFP SS-06BT-SFP Shown SS-06LX-SFP SS-06BT-SFP ww w.datacomsystems.com 34 56 Power LEDs LX Tap SFP Monitor Ports LX Tap Management Port Network A 3 4 5 6 Tools Network B Technical Specifications - VS-4-0G SS-06LX-SFP PORTS Network: Two () Duplex LC Single Mode Taps (9 Micron) Monitoring: Two () SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-06LX-SFP SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Dual Link Aggregation Tap (LX) with - SFP Monitoring Ports SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 7

You Can t Monitor What You Can t See SINGLEstream Quad Link Aggregation Tap (BT) with - SFP Monitoring Ports SS-40BT-SFP Achieve Full-Duplex Visibility across Four (4) In-Line Network Links even with Single Interface Monitoring Solutions Aggregation Monitoring full duplex network traffic and traffic from multiple sources is often a critical requirement for network monitoring applications. For example, in order to properly monitor channelized links (e.g. Gigabit EtherChannel), network professionals need to receive traffic simultaneously from multi-trunked full duplex channels. Because traffic in a Gigabit EtherChannel implementation is load balanced, packets are distributed across several different physical links. Often, traffic transmits on one segment and receives on another. This makes network analysis and monitoring especially challenging. If an analyzer or monitoring device is put on only one physical link, it will not see the entire conversation Also, while traditional taps might enable fullduplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Quad Link Aggregation Tap contains four (4) network taps. Each tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data collected from all four taps - even in a single trace file. protect Many traditional taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other. The built-in protect feature eliminates this point of network failure by continuously monitoring both sides of the tapped network for link status. If one side of the tap loses link status, protect will close the other side of the link, so routers and switches can engage protocols to bypass the failed link. protect will also keep monitoring both sides of the link until repaired, where it can then automatically re-establish the primary link. Timers (polling and recovery) and link reestablishment settings (manual or auto) are all user-configurable on both sides of the link and provide a level of convenience and flexibility not previously available in copper Gigabit taps. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Quad Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. 8 Benefits View entire full-duplex conversations even across meshed, channelized, or load balanced links using single-interface monitoring tools Save money by reducing number of required tools or tool interfaces necessary to monitor all your data Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Single point of deployment and remote management minimizes management expenses and reduces MTTR Features Aggregation - Receive copies of multiple network links or channels into one stream for visibility into complete network conversations protect - Ensure automatic failover and recovery of redundant paths and routing protocols Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Port Speeds from 0 to 000MB; supports full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security SFP Flexibility - monitor copper links with fiber tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Quad Link Aggregation Tap (BT) with - SFP Monitoring Ports SS-40BT-SFP SS-40BT-SFP www.datacomsystems.com 9 3 4 MONITOR SS-40BT-SFP www.datacomsystems.com RJ45 Network Tap Power LEDs RJ45 Network Tap RJ45 Network Tap RJ45 Network Tap SFP Monitoring Ports Management Port 9 3 4 MONITOR 3 4 3 4 5 6 7 8 9 0 Meshed Network Technical Specifications - VS-4-0G SS-40BT-SFP PORTS Network: Four (4) 0/00/000 Network Taps (RJ45) Monitoring: Two () SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-40BT-SFP SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Quad Link Aggregation Tap (BT) with - SFP Monitoring Ports SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 9

SS-0BT-BT/SFP SINGLEstream Configurable Dual Link Aggregation Optional -Unit (9 Inch) Rack Mount The SINGLEstream SS-0BT-BT/SFP Configurable Dual Link Aggregation provides maximum flexibility allowing a choice of aggregation or nonaggregation of the bi-directional data on two 0/00 or 000Mb links. This In-Line hands off the data to up to six tools with single NIC interfaces when used as an aggregation. When not aggregating, the bi-directional traffic on the link is handed off as two separate data streams to up to three tools with a dual NIC. The ports can also be configured as inputs to accept data from a SPAN/mirror port or to allow traffic injection back onto the link from connected tools. Manage via management port or local serial port protect feature allows the relay failover circuit to close if either or both sides of the link go down architecture on 6 ports allows the enduser to steer traffic as desired Dual redundant, load balanced power supplies SFP's available in SX and LX fiber and RJ45 copper for greater flexibility In-Line design eliminates contention for network access by freeing up SPAN/Mirror ports 4X7 access point for network monitoring and security tools Connection T E C H N I C A L S P E C I F I C AT I O N S Two () 0/00/000 (RJ45) Ports Four (4) 0/00/000 (RJ45), Two () SFP* Management Port (front) RJ45 @ 00Mbs Full-Duplex Serial Port (rear) DB9F Power Requirements Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A Certifications CE Physical Dimensions (HxWxD).0 x 8.00 x 7.0 in (.79 x 0.3 x 7.78 cm) Weight.6 lbs (0.7 kgs) Environmental Operating Temperature: 0º to 40ºC (3º to 04ºF) Storage Temperature: -30º to 65ºC (-º to 49F) Humidity: 5 to 95% non-condensing Warranty Two () Year Limited Warranty Order Information SS-0BT-BT/SFP RMC- SFPs SINGLEstream Configurable Dual Link Aggregation ( - 0/00/000 s, 4-0/00/000 & - SFP Ports) U Rack Mount Chassis SFP-LX, SFP-SX or SFP-RJ45 (Optional Additional Purchase) * SFP = Small Form Pluggable ACCESS YOUR NETWORK 9 Adler Drive East Syracuse, NY 3057 T: (35) 463-954 F: (35) 463-9557 DatacomSystems.com 8/08 Rev. Datacom Systems Inc. Copyright 99-008. All rights reserved. 0

You Can t Monitor What You Can t See SINGLEstream Dual Link Aggregation Tap (BT) with - SFP Monitoring Ports SS-06BT-SFP Achieve Full-Duplex Visibility for Two () In-Line Network Links even with Single Interface Monitoring Solutions Aggregation Monitoring full duplex network traffic from multiple sources is often a critical requirement for network monitoring applications. For example, in order to properly monitor redundant networks or a pair of load balanced links, network professionals might need to receive traffic simultaneously from two different network segments. In some cases, two network links may be bound together and operate as one logical network in order to improve bandwidth. In such an implementation, packets are distributed across two different physical links. Often, traffic transmits on one segment and receives on another. This makes network analysis and monitoring especially challenging. If an analyzer or monitoring device is put on only one physical link, it will not see the entire conversation Also, while traditional taps might enable fullduplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems have the required hardware to aggregate traffic. The SINGLEstream Dual Link Aggregation Tap has two () network taps. Each tap combines both directions of a full duplex data stream and allows connected monitoring devices, even those with only one NIC, to receive a copy of all the data collected from both taps in a single trace file. protect Many traditional taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other. The built-in protect feature eliminates this point of network failure by continuously monitoring both sides of the tapped network for link status. If one side of the tap loses link status, protect will close the other side of the link, so routers and switches can engage protocols to bypass the failed link. protect will also keep monitoring both sides of the link until repaired, where it can then automatically re-establish the primary link. Timers (polling and recovery) and link reestablishment settings (manual or auto) are all user-configurable on both sides of the link and provide a level of convenience and flexibility not previously available in copper Gigabit taps. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. Benefits View entire full-duplex conversations even across redundant or load balanced links using single-interface monitoring tools Save money by reducing number of required tools or tool interfaces necessary to monitor all your data Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Single point of deployment and remote management minimizes management expenses and reduces MTTR Automatic coverage of redundant network - One tool can monitor two networks Features Aggregation - Receive copies of multiple network links or channels into one stream for visibility into complete network conversations protect - Ensure automatic failover and recovery of redundant paths and routing protocols Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Port Speeds from 0 to 000MB; supports full duplex, half duplex, or auto-negotiate SFP Flexibility - monitor copper links with fiber tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Dual Link Aggregation Tap (BT) with - SFP Monitoring Ports SS-06BT-SFP SS-06BT-SFP SS-06BT-SFP ww w.datacomsystems.com 5 34 56 Power LEDs RJ45 Tap RJ45 Tap Monitoring Ports Management Port Network A 3 4 5 6 Tools Network B Technical Specifications - VS-4-0G SS-06BT-SFP PORTS Network: Two () 0/00/000 Network Taps (RJ45) Monitoring: Two () SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-06BT-SFP SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Dual Link Aggregation Tap (BT) with - SFP Monitoring Ports SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved.

You Can t Monitor What You Can t See SINGLEstream Dual Link Aggregation Tap (BT) with - 0/00/000 Monitoring Ports SS-06BT-BT Achieve Full-Duplex Visibility for Two () In-Line Network Links even with Single Interface Monitoring Solutions Aggregation Monitoring full duplex network traffic from multiple sources is often a critical requirement for network monitoring applications. For example, in order to properly monitor redundant networks or a pair of load balanced links, network professionals might need to receive traffic simultaneously from two different network segments. In some cases, two network links may be bound together and operate as one logical network in order to improve bandwidth. In such an implementation, packets are distributed across two different physical links. Often, traffic transmits on one segment and receives on another. This makes network analysis and monitoring especially challenging. If an analyzer or monitoring device is put on only one physical link, it will not see the entire conversation Also, while traditional taps might enable fullduplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems have the required hardware to aggregate traffic. The SINGLEstream Dual Link Aggregation Tap has two () network taps. Each tap combines both directions of a full duplex data stream and allows connected monitoring devices, even those with only one NIC, to receive a copy of all the data collected from both taps in a single trace file. protect Many traditional taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other. The built-in protect feature eliminates this point of network failure by continuously monitoring both sides of the tapped network for link status. If one side of the tap loses link status, protect will close the other side of the link, so routers and switches can engage protocols to bypass the failed link. protect will also keep monitoring both sides of the link until repaired, where it can then automatically re-establish the primary link. Timers (polling and recovery) and link reestablishment settings (manual or auto) are all user-configurable on both sides of the link and provide a level of convenience and flexibility not previously available in copper Gigabit taps. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. 3 Benefits View entire full-duplex conversations even across redundant or load balanced links using single-interface monitoring tools Save money by reducing number of required tools or tool interfaces necessary to monitor all your data Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Single point of deployment and remote management minimizes management expenses and reduces MTTR Automatic coverage of redundant network - One tool can monitor two networks Features Aggregation - Receive copies of multiple network links or channels into one stream for visibility into complete network conversations protect - Ensure automatic failover and recovery of redundant paths and routing protocols Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Port Speeds from 0 to 000MB; supports full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Dual Link Aggregation Tap (BT) with - 0/00/000 Monitoring Ports SS-06BT-BT SS-06BT-BT SS-06BT-SFP ww w.datacomsystems.com 34 56 Power LEDs RJ45 Tap RJ45 Tap Monitoring Ports Management Port Network A 3 4 5 6 Network B Tools Technical Specifications - VS-4-0G SS-06BT-BT PORTS Network: Two () 0/00/000 Network Taps (RJ45) Monitoring: Two () 0/00/000 Ports (RJ45) Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-06BT-BT Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Dual Link Aggregation Tap (BT) with - 0/00/000 Monitoring Ports - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 4

SINGLEstream Gigabit to 0 Gigabit Link Aggregation Tap (SS-4LX-0G) Four (4) Configurable (XFP) Ports (0 Gigabit) Five (5) LX Network Taps (Gigabit) AGGREGATION The SINGLEstream 4LX-0Gb can combine data from up to five single mode Gigabit network segments into one or more streams of data. Connected 0 Gigabit monitoring devices can receive aggregated data from multiple network segments with just one network interface card (NIC) each. Any of the configurable 0 Gigabit Ports can also be set to receive data from SPAN ports. REGENERATION With a total of four (4) configurable ports the SS-4LX-0Gb can be configured to have multiple monitoring ports to allow connected devices to receive multiple copies of the same data stream. Allowing multiple monitoring and analysis devices to collect data from the same network segments at the same time eliminates contention for SPAN ports. PORT STEERING The port architecture of the SS-4LX-0Gb allows you to send traffic from any network port to any monitoring port eliminating the need for network personnel to manage or change complex configurations of SPAN ports or move tools around their network. 4X7 access point for network monitoring and security tools Passive taps are 00% fault tolerant and won t break the link even if power is lost to the device architecture can send traffic from any network port to any monitoring port, while XFP ports can be configured as monitoring ports or accept input from SPAN Many-to-Any architecture combines traffic from multiple ports, providing visibility into multiple network connections One-to-Many architecture allows you to send multiple copies of data from the input port to multiple monitoring devices Hot swapable dual redundant load balanced power supplies Hot swappable management card compatible with filtering T e c h n i c a l S p e c i f i c at i o n s Connectors Network Ports: Five (5) Taps w/ Quad LC Connectors [9 micron] Ports: Four (4) XFP Management Port (rear): RJ45 @ 00Mbs Full-Duplex Configuration Port (rear): DB9F Serial Port Power Requirements Input: 00-40VAC, 50-60Hz, 0.4-0.A Split Ratio 50/50 Insertion Loss 4dB Certifications CE Physical Dimensions (HxWxD).75 x 9.00 x.00 in (4.45 x 48.6 x 53.35 cm) Weight 3.75 lbs (6.4 kgs) Environmental Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing Warranty Two () Year Limited Warranty Order Information SS-4LX-0G XFPs Dual Redundant Hot Swappable Power Supplies Serial Ports Management Port SINGLEstream Gigabit to 0 Gigabit Link Aggregation Tap (4 - XFP Ports, 5 LX Network Taps) XFP-SR or XFP-LR (Required Additional Purchase) Upgradable Management Card 9 Adler Drive East Syracuse, NY 3057 T: (35) 463-954 F: (35) 463-9557 DatacomSystems.com ACCESS YOUR NETWORK Datacom Systems Inc. Copyright 99-008. All rights reserved. 5

You Can t Monitor What You Can t See SINGLEstream 0 Gigabit Link Aggregation Tap with 4 - XFP Monitoring Ports SS-06-0G Models Multiple Tool Access and Full-Duplex Visibility at 0G for Single Interface Monitoring Solutions 0 Gigabit Full Duplex Aggregation While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream 0 Gigabit Link Aggregation Tap combines both directions of a 0 Gigabit full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Data Filtering Instead of tools attempting to keep up with high-speed aggregated traffic streams, the SS-06-0G-F (with data filtering) model provides the option of applying filters to the data to increase tool efficiency and eliminate port oversubscription. Line-rate hardware filtering on each port allows you to customize and streamline the amount and type of data each connected monitoring tool receives. Because they are receiving only traffic of interest, tools run faster, data is easier to work with, and issues are resolved quicker. Filters include IP and MAC ranges, VLAN, frame, port number, protocol type, even customizable offsets in the packet header. Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Any of the SS-06-0G s four (4) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. Benefits 00% Network Uptime - fiber tap is completely passive and won t disrupt the network even if power is lost to the tap View entire 0G full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources - port steer traffic to different tools or turn monitoring ports into additional network ports to receive input from SPAN Filtering - Line-rate hardware-based filtering can eliminate port oversubscription and customize data flow to each tool (-F Model) Monitoring Ports can be set for full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security Dual Redundant Power Supplies are hot swappable and load balanced to ensure monitoring uptime 6

You Can t Monitor What You Can t See SINGLEstream 0 Gigabit Link Aggregation Tap with 4 - XFP Monitoring Ports SS-06-0G Models Internal Port Diagram 3 4 5 6 Rear View Insert between two network devices Data Recorder Dual Redundant Hot Swappable Power Supplies Serial Ports Management Port Upgradable Management Card Any-to-any ports can receive input from SPAN Technical Specifications - VS-4-0G SS-06-0G PORTS Network: One () Network Tap with Dual LC Connectors Monitoring: Four (4) XFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F and DB9M REQUIREMENTS Hot Swappable Dual Redundant Power Supplies (AC or DC) AC: 00-40VAC, 50-60 Hz, 0.4A-0.A DC: 40.5-7.0VDC, 0.0-5.0A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).75 x 9.00 x.00 in (4.45 x 48.6 x 53.35 cm) WEIGHT 3.5 lbs (6. kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Standard Model: Two () Year Limited Warranty Filter Model: One () Year Limited Warranty -Support Contract Required ORDER INFORMATION SS-06-0G SS-06-0G-F SR*, LR, or ER AC or DC XFP S-SS-06-0G-F Note: SINGLEstream 0 Gigabit Link Aggregation Tap with 4 - XFP Monitoring Ports SINGLEstream 0 Gigabit Link Aggregation Tap with Data Filtering and 4 - XFP Monitoring Ports SR (Short Range): Multi-mode (50 or 6.5 micron) LR (Long Range): Single mode (9 micron) ER (Extended Range): Single mode (9 micron) *Specify tap diameter when ordering AC or DC Power XFP-SR: 850nm XFP-LR: 30nm XFP-ER: 550nm One () Year Hardware and Software Support SFPs and XFPs are Optional Additional Purchase 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 7

You Can t Monitor What You Can t See SINGLEstream 0 Gigabit Link Aggregation Tap with - XFP Monitoring Ports SS-04-0G Models Full-Duplex Visibility at 0G for Single Interface Monitoring Solutions 0 Gigabit Full Duplex Aggregation While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream 0 Gigabit Link Aggregation Tap combines both directions of a 0 Gigabit full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Data Filtering Instead of tools attempting to keep up with high-speed aggregated traffic streams, the SS-04-0G-F (with data filtering) provides the option of applying filters to the data to increase tool efficiency and eliminate port oversubscription. Line-rate hardware filtering on each port allows you to customize and streamline the amount and type of data each connected monitoring tool receives. Because they are receiving only traffic of interest, tools run faster, data is easier to work with, and issues are resolved quicker. Filters include IP and MAC ranges, VLAN, frame, port number, protocol type, even customizable offsets in the packet header. Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. Benefits 00% Network Uptime - fiber tap is completely passive and won t disrupt the network even if power is lost to the tap View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Filtering - Line-rate hardware-based filtering can eliminate port oversubscription and customize data flow to each tool (-F Model) Monitoring Ports can be set for full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security Dual Redundant Power Supplies are hot swappable and load balanced to ensure monitoring uptime 8

PORT P ORT You Can t Monitor What You Can t See SINGLEstream 0 Gigabit Link Aggregation Tap with - XFP Monitoring Ports SS-04-0G Models Internal Port Diagram 3 4 TM SINGLEstream SS-04SR-0G ww w.datacomsystem s.com NETWORK PORTS AB MONITOR PORTS Rear View Router Dual Redundant Hot Swappable Power Supplies Serial Ports Management Port Upgradable Management Card Switch Technical Specifications -- SS-04-0G VS-4-0G PORTS Network: One () Network Tap with Dual LC Connectors Monitoring: Two () XFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F and DB9M REQUIREMENTS Hot Swappable Dual Redundant Power Supplies (AC or DC) AC: 00-40VAC, 50-60 Hz, 0.4A-0.A DC: 40.5-7.0VDC, 0.0-5.0A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).75 x 9.00 x.00 in (4.45 x 48.6 x 53.35 cm) WEIGHT 3.5 lbs (6. kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F ( 0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Standard Model: Two () Year Limited Warranty Filter Model: One () Year Limited Warranty -Support Contract Required ORDER INFORMATION SS-04-0G SS-04-0G-F SR*, LR, or ER AC or DC XFP S-SS-04-0G-F Note: SINGLEstream 0 Gigabit Link Aggregation with - SFP Monitoring Ports SINGLEstream 0 Gigabit Link Aggregation with Data Filtering and - SFP Monitoring Ports SR (Short Range): Multi-mode (50 or 6.5 micron) LR (Long Range): Single mode (9 micron) ER (Extended Range): Single mode (9 micron) *Specify tap diameter when ordering AC or DC Power XFP-SR: 850nm XFP-LR: 30nm XFP-ER: 550nm One () Year Hardware and Software Support SFPs and XFPs are Optional Additional Purchase 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 9

You Can t Monitor WhatYou Can t See SINGLEstream Link Aggregation Tap (LX) with 8 - SFP Monitoring Ports SS-0LX-SFP Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-0LX-SFP s eight (8) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. 0 Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources - port steer traffic to different tools or turn monitoring ports into additional network ports to receive input from SPAN 00% Network Uptime - Single mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate SFP Flexibility - monitor fiber links with copper tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access WhatYou Your Network Can t See SINGLEstream Link Aggregation Tap (LX) with 8 - SFP Monitoring Ports SS-0LX-SFP SS-0SX-BT Shown SS-0LX-BT SS-0SX-BT 3 4 5 6 7 8 3 4 5 6 7 Power LEDs Monitoring Ports LX Tap Management Port 3 4 5 6 7 8 9 0 Application Performance Monitor Data Recorder Tools Insert between two network devices Technical Specifications - VS-4-0G SS-0LX-BT PORTS Network: One () Single Mode Tap [9 Micron] Monitoring: Eight (8) SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-0LX-SFP SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (LX) with 8 - SFP Monitoring Ports SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved.

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (SX) with 8 - SFP Monitoring Ports SS-0SX-SFP Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-0SX-SFP s eight (8) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources - port steer traffic to different tools or turn monitoring ports into additional network ports to receive input from SPAN 00% Network Uptime - Multi-mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate SFP Flexibility - monitor fiber links with copper tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

TM You Can t Monitor Access What Your Network Can t See SINGLEstream Link Aggregation Tap (SX) with 8 - SFP Monitoring Ports SS-0SX-SFP SS-0SX-BT 3 4 5 6 7 Power LEDs SX Tap Monitoring Ports Management Port Application Performance Monitor 3 4 5 6 7 8 9 0 Insert between two network devices Data Recorder Tools Technical Specifications - VS-4-0G SS-0SX-BT PORTS Network: One () Multi-mode Tap [50 or 6.5 micron] Monitoring: Eight (8) SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-0SX-SFP *SX SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (SX)* with 8 - SFP Monitoring Ports Specify 50 or 6.5 Micron SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 3

You Can t Monitor WhatYou Can t See SINGLEstream Link Aggregation Tap (LX) with 8-0/00/000 Monitoring Ports SS-0LX-BT Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-0LX-BT s eight (8) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. 4 Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources - port steer traffic to different tools or turn monitoring ports into additional network ports to receive input from SPAN 00% Network Uptime - Single mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Compatible with all major manufacturers monitoring systems and analyzers Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access WhatYou Your Network Can t See SINGLEstream Link Aggregation Tap (LX) with 8-0/00/000 Monitoring Ports SS-0LX-BT SS-0SX-BT Shown SS-0LX-BT SS-0SX-BT 3 4 5 6 7 8 3 4 5 6 7 Power LEDs Monitoring Ports LX Tap Management Port 3 4 5 6 7 8 9 0 Application Performance Monitor Data Recorder Tools Insert between two network devices Technical Specifications - VS-4-0G SS-0LX-BT PORTS Network: One () Single Mode Tap [9 Micron] Monitoring: Eight (8) 0/00/000 (RJ45) Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-0LX-BT Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (LX) with 8-0/00/000 Monitoring Ports - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 5

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (SX) with 8-0/00/000 Monitoring Ports SS-0SX-BT Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-0SX-BT s eight (8) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. 6 Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources - port steer traffic to different tools or turn monitoring ports into additional network ports to receive input from SPAN 00% Network Uptime - Multi-mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Link Aggregation Tap (SX) with 8-0/00/000 Monitoring Ports SS-0SX-BT SS-0SX-BT SS-0SX-BT 3 4 5 6 7 3 4 5 6 7 Power LEDs Monitoring Ports SX Tap Management Port Application Performance Monitor 3 4 5 6 7 8 9 0 Insert between two network devices Data Recorder Tools Technical Specifications - VS-4-0G SS-0SX-BT PORTS Network: One () Multi-mode Tap [50 or 6.5 micron] Monitoring: Eight (8) 0/00/000 (RJ45) Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-0SX-BT Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (SX) with 8-0/00/000 Monitoring Ports - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 7

You Can t Monitor WhatYou Can t See SINGLEstream Link Aggregation Tap (LX) with 4-0/00/000 Monitoring Ports SS-06LX-BT Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-06LX-BT s four (4) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. 8 Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources - port steer traffic to different tools or turn monitoring ports into additional network ports to receive input from SPAN 00% Network Uptime - Single mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Compatible with all major manufacturers monitoring systems and analyzers Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

Access Your Network SINGLEstream Link Aggregation Tap (LX) with 4-0/00/000 Monitoring Ports SS-06LX-BT SS-06SX-BT Shown SS-06LX-BT www.datacomsystems.com TM 3 4 3 4 Power LEDs Monitoring Ports LX Tap Management Port Data Recorder 3 4 5 6 Application Performance Monitor Insert between two network devices Technical Specifications - VS-4-0G SS-06LX-BT PORTS Network: One () Single Mode Tap [9 Micron] Monitoring: Four (4) 0/00/000 (RJ45) Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-06LX-BT Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (LX) with 4-0/00/000 Monitoring Ports - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 9

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (SX) with 4-0/00/000 Monitoring Ports SS-06SX-BT Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-06SX-BT s four (4) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. 30 Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources - port steer traffic to different tools or turn monitoring ports into additional network ports to receive input from SPAN 00% Network Uptime - Multi-mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Link Aggregation Tap (SX) with 4-0/00/000 Monitoring Ports SS-06SX-BT SS-06SX-BT TM 3 4 3 4 Power LEDs Monitoring Ports SX Tap Management Port Data Recorder 3 4 5 6 Application Performance Monitor Insert between two network devices Technical Specifications - VS-4-0G SS-06SX-BT PORTS Network: One () Multi-mode Tap [50 or 6.5 micron] Monitoring: Four (4) 0/00/000 (RJ45) Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-06SX-BT Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (SX) with 4-0/00/000 Monitoring Ports - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 3

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (LX) with - SFP Monitoring Ports SS-04LX-SFP Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. While some copper Gigabit taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other, the passive nature of optical fiber also eliminates this possibility of network failure. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources 00% Network Uptime - Single mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security SFP Flexibility - monitor fiber links with copper tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime 3

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (LX) with - SFP Monitoring Ports SS-04LX-SFP SS-04LX-SFP SS-04BT-BT Shown SS-04BT-BT ww w.datacomsystems.com Power LEDs LX Tap Monitoring Ports (SFP) Management Port PO WER 3 4 Technical Specifications -- SS-04LX-SFP VS-4-0G PORTS Network: One () Single Mode Tap [9 Micron] Monitoring: Two () SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60 Hz, 0.4A-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F ( 0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-04LX-SFP SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation (LX) with - SFP Monitoring Ports SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 33

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (LX) with - 0/00/000 Monitoring Ports SS-04LX-BT Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. While some copper Gigabit taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other, the passive nature of optical fiber also eliminates this possibility of network failure. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources 00% Network Uptime - Single mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security Compatible with all major manufacturers monitoring systems and analyzers Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime 34

You Can t Monitor Access What Your Network Can t See SINGLEstream Link Aggregation Tap (LX) with - 0/00/000 Monitoring Ports SS-04LX-BT SS-04LX-B T www.datacomsystems.com SS-04BT-BT Shown SS-04BT-BT ww w.datacomsystems.com Power LEDs Monitoring Ports LX Tap Management Port 3 4 Technical Specifications - VS-4-0G SS-04LX-BT PORTS Network: One () Single Mode Tap [9 Micron] Monitoring: Two () 0/00/000 (RJ45) Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-04LX-BT Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (LX) with - 0/00/000 Monitoring Ports - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 35

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (SX) with - SFP Monitoring Ports SS-04SX-SFP Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic in timestamp order from two different sources is often an important and frequent requirement in network analysis, commonly referred to as data aggregation. By aggregating full duplex data, network professionals can measure latency between two sources such as the ingress and egress of a router or switch. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have that capability. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream, preserves the ordering of packets, and allows any connected monitoring device (even those with one NIC) to receive a copy of all the data in timestamp order. Dual Stream Mode For dual-receive capable tools or times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. While some copper Gigabit taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other, the passive nature of optical fiber also eliminates this possibility of network failure. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources 00% Network Uptime - Multi-mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security SFP Flexibility - monitor fiber links with copper tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime 36

You Can t Monitor Access What Your Network Can t See SINGLEstream Link Aggregation Tap (SX) with - SFP Monitoring Ports SS-04SX-SFP SS-04SX-SFP SS-04BT-BT Shown SS-04BT-BT ww w.datacomsystems.com Power LEDs SX Tap Monitoring Ports (SFP) Management Port 3 4 Technical Specifications - SS-04SX-SFP VS-4-0G PORTS Network: One () Multi-Mode Tap [50 or 6.5 Micron] Monitoring: Two () SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60 Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storeage Temperature: - to 49 F (-30 to 65 F) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-04SX-SFP *SX SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (SX)* with - SFP Monitoring Ports) Specify 50 or 6.5 Micron SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 37

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (SX) with - 0/00/000 Monitoring Ports SS-04SX-BT Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools and times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. While some copper Gigabit taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other, the passive nature of optical fiber also eliminates this possibility of network failure. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources 00% Network Uptime - Multi-mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Monitoring Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security Compatible with all major manufacturers monitoring systems and analyzers Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime 38

You Can t Monitor Access What Your Network Can t See SINGLEstream Link Aggregation Tap (SX) with - 0/00/000 Monitoring Ports SS-04SX-BT SS-04SX-BT www.datacomsystems.com SS-04BT-BT Shown SS-04BT-BT ww w.datacomsystems.com Monitoring Ports (RJ45) Power LEDs LX Tap Management Port 3 4 Technical Specifications - VS-4-0G S 0 4 S X-B T PORTS Network: One () Multi-Mode Tap [50 or 6.5 Micron] Monitoring: Two () 0/00/000 (RJ45) Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-04SX-BT *SX Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (SX)* with - 0/00/000 Monitoring Ports Specify 50 or 6.5 Micron Fiber - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 39

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (BT) with 8 Monitoring Ports (6-BT and -SFP) SS-0BT-BT/SFP Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools and times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). protect Many traditional taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other. The built-in protect feature eliminates this point of network failure by continuously monitoring both sides of the tapped network for link status. If one side of the link fails for any reason, protect will close the other side of the link immediately, so routers and switches can engage redundant protocols and failover systems. protect will also keep monitoring both sides of the link until they become available again, where it can then automatically re-establish the primary link. Timers (polling and recovery) and link re-establishment settings (manual or auto) are all user-configurable on both sides of the link and provide a level of convenience and flexibility not previously available in copper Gigabit taps. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-0BT-BT/SFP s eight (8) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. 40 Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations - port steer traffic to different tools or turn monitoring ports into additional network ports to receive input from SPAN Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources protect - ensure automatic failover and recovery of redundant paths and routing protocols Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate SFP Flexibility - monitor copper links with fiber tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Link Aggregation Tap (BT) with 8 Monitoring Ports (6-BT and -SFP) SS-0BT-BT/SFP SS-0SX-BT Shown SS-0BT-BT/SFP SS-0SX-BT 3 RJ45 Network Tap Power LEDs RJ45 Monitoring Ports SFP Monitoring Ports Management Port 3 4 5 6 7 Application Performance Monitor 3 4 5 6 7 8 9 0 Insert between two network devices Data Recorder Tools Technical Specifications - - SS- VS-4-0G 0BT- Bt/ SFP PORTS Network: One () 0/00/000 Network Tap (RJ45) Monitoring: Six (6) 0/00/000 and Two () SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-0BT-BT/SFP SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (BT) with 8 Monitoring Ports (6-BT and -SFP) SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 4

You Can t Monitor What You Can t See SINGLEstream Link Aggregation Tap (BT) with - SFP Monitoring Ports SS-04BT-SFP Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools and times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). protect Many traditional taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other. The built-in protect feature eliminates this point of network failure by continuously monitoring both sides of the tapped network for link status. If one side of the link fails for any reason, protect will close the other side of the link immediately, so routers and switches can engage redundant protocols and failover systems. protect will also keep monitoring both sides of the link until they become available again, where it can then automatically re-establish the primary link. Timers (polling and recovery) and link re-establishment settings (manual or auto) are all user-configurable on both sides of the link and provide a level of convenience and flexibility not previously available in copper Gigabit taps. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. 4 Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations protect - ensure automatic failover and recovery of redundant paths and routing protocols Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security SFP Flexibility - monitor copper links with fiber tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream Link Aggregation Tap (BT) with - SFP Monitoring Ports SS-04BT-SFP RJ45 Network Tap Power LEDs SS-04BT-SFP www.datacomsystems.com SFP Monitoring Ports Management Port SS-04BT-BT ww w.datacomsystems.com SS-04BT-BT Shown 3 4 Technical Specifications - VS-4-0G SS-04BT-SFP PORTS Network: One () 0/00/000 Network Tap (RJ45) Monitoring: Two () SFP Ports Management: RJ45 @ 00Mbs Full-Duplex Serial: DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.4-0.A Output: 5VDC,.5A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENTAL Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-04BT-SFP SFP Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream Link Aggregation Tap (BT) with - SFP Monitoring Ports SFP-LX, SFP-SX or SFP-RJ45 (Required Additional Purchase) - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 43

You Can t Monitor What You Can t See SINGLEstream 0/00/000 Link Aggregation Tap SS-04BT-BT Full-Duplex Visibility for Single Interface Monitoring Solutions Full Duplex Aggregation Monitoring network traffic from two different sources is an important and frequent requirement in network analysis, commonly referred to as data aggregation. For example, in order to properly troubleshoot most network problems, network professionals need to receive traffic from both sides of a full duplex conversation. While traditional taps might enable full-duplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems, including the most popular software solutions, have the required hardware to aggregate traffic. The SINGLEstream Link Aggregation Tap combines both directions of a full duplex data stream and allows any connected monitoring device, including those with only one NIC, to receive a copy of all the data - even in a single trace file. Dual Stream Mode For dual-receive capable tools and times when there is no substitute for full line rate data capture (e.g. network attacks), the SINGLEstream can be configured to work exactly like a traditional full duplex tap, providing a copy of full-rate Gigabit data to connected tools in two separate streams (Tx and Rx). protect Many traditional taps prevent the operation of redundant routing and failover systems because they keep both sides of the network invisible to the other. The built-in protect feature eliminates this point of network failure by continuously monitoring both sides of the tapped network for link status. If one side of the link fails for any reason, protect will close the other side of the link immediately, so routers and switches can engage redundant protocols and failover systems. protect will also keep monitoring both sides of the link until they become available again, where it can then automatically re-establish the primary link. Timers (polling and recovery) and link re-establishment settings (manual or auto) are all user-configurable on both sides of the link and provide a level of convenience and flexibility not previously available in copper Gigabit taps. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Reliable and Easy to Use Unlike setting up operating systems and binding NICs, the SINGLEstream Link Aggregation Tap is simple to deploy, and every unit comes with dual redundant power supplies to ensure monitoring uptime. 44 Benefits View entire full-duplex conversations using single-interface monitoring tools Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Easily share test access points without maintenance windows or approval Single point of deployment and remote management minimizes management expenses and reduces MTTR Keep your monitoring tool plugged in while troubleshooting the same link Features Aggregation - Combine multiple network links or channels into one stream for visibility into complete network conversations protect - ensure automatic failover and recovery of redundant paths and routing protocols Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Port Speeds from 0 to 000MB, full duplex, half duplex, or auto-negotiate Stays invisible to the network for enhanced security Compatible with all major manufacturers monitoring systems and analyzers Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime

You Can t Monitor Access What Your Network Can t See SINGLEstream 0/00/000 Link Aggregation Tap SS-04BT-BT SS-04BT-BT www.datacomsystems.com SS-04BT-BT ww w.datacomsystems.com Power LEDs Network Tap Monitoring Ports Management Port 3 4 Technical Specifications - - SS-04BT-BT VS-4-0G PORTS Network: One () 0/00/000 Network Tap (RJ45) Monitoring: Two () 0/00/000 Ports (RJ45) Management (front): RJ45 @ 00Mbs Full-Duplex Serial (rear): DB9F REQUIREMENTS Two () External AC Adapters (Included) Input: 00-40VAC, 50-60Hz, 0.6-0.3A Output: 5VDC, A CERTIFICATIONS CE Fully RoHS Compliant PHYSICAL DIMENSIONS (HXWXD).0 x 8.00 x 7.00 in (.79 x 0.3 x 7.78 cm) WEIGHT.6 lbs (0.7 kgs) ENVIRONMENT Operating Temperature: 0 to 40 C (3º to 04ºF) Storage Temperature: -30 to 65 C (-º to 49ºF) Humidity: 5 to 90% non-condensing WARRANTY Two () Year Limited Warranty ORDER INFORMATION SS-04BT-BT Optional Equipment RMC- RMC-- RPS--5-AC (or -DC) SINGLEstream 0/00/000 Link Aggregation Tap with - 0/00/000 Monitoring Ports - U Rack Mount Chassis - 6U Rack Mount Chassis - Dual Redundant Rack Mountable Power Supply Unit (specify AC or DC) 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 45

Access Your Network FILTERED SINGLEstream DUAL Link Aggregation Tap FSS-000 SERIES Apply port level packet filtering to your data, so you can easily ensure your network and security tools only receive traffic of interest. Collect only the data YOU want and Increase Tool Efficiency The SINGLEstream Aggregation Tap w/ Filtering gives you the power to apply port level packet filtering to your data, so you can easily ensure your network and security tools only receive traffic of interest. Prevent Port Oversubscription and Data Overload Line-rate filtering provides you the ability to eliminate unwanted traffic from your analysis tools or security sensors. With less data to work with, network devices run faster and more effectively. While filtering can eliminate the possibility of port oversubscription, providing an effective solution, especially for software-based monitoring systems. Eliminate Bottlenecks - Load Balance your Network and your Network Tools Using the built-in technologies of link aggregation, regeneration, and filtering, you can quickly and easily load balance both your network and your network tools and eliminate bottlenecks. Aggregation lets you load balance your network with confidence. The Filtered SINGLEstream will combine one or more full duplex streams of data from one or more network segments, reassemble the conversation, and send an exact copy to your connected monitoring device. Regeneration allows you to attach more than one device to a single network segment. Connect an analyzer and a security sensor to the same link, and you can troubleshoot your network without having to disconnect your IDS. Add filtering, and you can send only the data you want to each tool, improving monitoring efficiency, speed, and network uptime. (Network A + B ) (Network A + B ) (Network A + B ) (Network A + B ) NETWORK ANALYZER # ALL TRAFFIC IP A ddress R ange (9.68.8.x - 9.68.54.x) NETWORK ANALYZER # WEB IDS ALL TRAFFIC IP A ddress R ange (9.68.0.x - 9.68.7.x) PORT 8 0 ALL TRAFFIC Monitor Asymmetrically Routed Data with Ease Aggregate and reassemble full duplex conversations from multi-trunked links, redundant networks, EtherChannel, load balanced servers, and asymmetrically routed traffic Simultaneously monitor data at multiple points on the network with the same set of devices for a complete end-to-end view of your traffic Fewer Tools to Manage - Save Time and Money Aggregation lets you combine multiple network segments into one output of data, so you can use as little as one tool to monitor multiple networks. Central deployment saves time, while fewer tools saves money on deployment and ongoing maintenance and licensing costs. Empower your Legacy Network Devices Don t throw out your old tools - empower them! With proper uses of filtering, you can use a 0/00 tool to monitor a Gigabit network. Available in fiber and copper, the Filtered SINGLEstream Link Aggregation Tap can maximize the ROI of your existing network devices. With the Filtered SINGLEstream s flexible any to any architecture, you can designate the port assignments to meet your specific needs. Any of the connected monitoring devices can see any of the connected network links. You can also quickly and easily change and customize port assignments on the fly with software, so there is no need to disconnect and reconnect any of the physical links if you want to assign a different tool to view a different network segment. Additional Features & Benefits Flexible network connectivity - Small form pluggables (SFP) allow you to connect up to four (4) SX, LX, or 0/00/000 monitoring tools. Network ports are available in both fiber and copper. Easy to use client management interface simply access and manage from anywhere in your network. Built-in 5MB buffer manages utilization overflow and significantly reduces chances of port over-subscription. Dual redundant power supplies insure seamless monitoring even if the main power source is unavailable. Easy to install U space-saving design fits conventional 9 rack. 46

AGGREGATION BUFFER FILTER Access Your Network FILTERED SINGLEstream DUAL Link Aggregation Tap FSS-000 SERIES NETWORK ANALYZER Router Firewall Switch Network A PROBE FORENSICS COLLECTION Filtered SINGLEstream Network B Analyzer Application Monitor IDS IDS Forensic Collection Technical Specifications - FSS-000 Connectors Network: Two () RJ45 or LC (SX or LX) Network Taps Monitor: Four (4) RJ45 or SFP (LX or SX) Monitoring Ports Management: RJ45 Configuration: DB9F Serial PoweR 5VDC,.5A Redundant Power Supplies Source Voltage: 85-64 Volts AC Frequency Range: 47-63 Hz Certifications CE RoHS Compliant Physical Dimensions (H x W x D).75 x 9.00 x.75 in (4.45 x 48.6 x 53.35 cm) Weight 7.00 lbs 3.8 kgs Environmental Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WarrantY One () Year Limited Warranty (Support Contract Required) order information FSS-000BT FSS-000BT/SX FSS-000BT/LX FSS-000SX FSS-000LX SFP-SX SFP-LX S-FSS-000 Filtered singlestream dual link Aggregation tap (BT to BT) Filtered singlestream dual link Aggregation tap (BT to SFP-SX) Filtered singlestream dual link Aggregation tap (BT to SFP-LX) Filtered singlestream dual link Aggregation tap (SX to SFP-SX) Filtered singlestream dual link Aggregation tap (LX to SFP-LX) SX Gigabit Small form Pluggable SX Gigabit Small form Pluggable One () Year Hardware and Software Support 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 47

Access Your Network FILTERED SINGLEstream Link Aggregation Tap FSS-000 SERIES Apply port level packet filtering to your data, so you can easily ensure your network and security tools only receive traffic of interest. Collect only the data YOU want and Increase Tool Efficiency The SINGLEstream Aggregation Tap w/ Filtering gives you the power to apply port level packet filtering to your data, so you can easily ensure your network and security tools only receive traffic of interest. Prevent Port Oversubscription and Data Overload Line-rate filtering provides you the ability to eliminate unwanted traffic from your analysis tools or security sensors. With less data to work with, network devices run faster and more effectively. While filtering can eliminate the possibility of port oversubscription, providing an effective solution, especially for software-based monitoring systems. Load Balance your Network Tools Using the built-in technologies of link regeneration and filtering, you can quickly and easily distribute traffic to multiple tools and eliminate bottlenecks. The Filtered SINGLEstream will combine and reassemble both sides of a ful duplex conversation in time stamp order, so your network tools don t have to, while regeneration allows you to receive up to four copies of the data, so you can attach more than one device to a single network segment. For example, onnect an analyzer and a security sensor to the same link, and you can troubleshoot your network without having to disconnect your IDS. Add filtering, and you can send only the data you want to each tool, improving monitoring efficiency, speed, and network uptime. Filter up to Four (4) Copies of One Data Stream NETWORK ANALYZER # ALL TRAFFIC IP A ddress R ange (9.68.8.x - 9.68.54.x) NETWORK ANALYZER # WEB IDS Empower your Legacy Network Devices Don t throw out your old tools - empower them! With proper uses of filtering, you can use a 0/00 tool to monitor a Gigabit network. Available in fiber and copper, the Filtered SINGLEstream Link Aggregation Tap can maximize the ROI of your existing network devices. With the Filtered SINGLEstream s flexible any to any architecture, you can designate the port assignments to meet your specific needs. Any of the connected monitoring devices can see any of the connected network links. You can also quickly and easily change and customize port assignments on the fly with software, so there is no need to disconnect and reconnect any of the physical links if you want to assign a different tool to view a different network segment. 48 ALL TRAFFIC IP A ddress R ange (9.68.0.x - 9.68.7.x) PORT 8 0 ALL TRAFFIC Additional Features & Benefits Flexible network connectivity - Small form pluggables (SFP) allow you to connect up to four (4) SX, LX, or 0/00/000 monitoring tools. Network ports are available in both fiber and copper. Easy to use client management interface simply access and manage from anywhere in your network. Built-in 5MB buffer manages utilization overflow and significantly reduces chances of port over-subscription. Dual redundant power supplies insure seamless monitoring even if the main power source is unavailable. Easy to install U space-saving design fits conventional 9 rack.

AGGREGATION BUFFER FILTER Access Your Network FILTERED SINGLEstream Link Aggregation Tap FSS-000 SERIES NETWORK ANALYZER Router Switch Network Tap PROBE FORENSICS COLLECTION Filtered SINGLEstream Analyzer Application Monitor IDS IDS Forensic Collection Technical Specifications - FSS-000 Connectors Network: One () RJ45 or LC (SX or LX) Network Tap Monitor: Four (4) RJ45 or SFP (LX or SX) Monitoring Ports Management: RJ45 Configuration: DB9F Serial PoweR 5VDC,.5A Redundant Power Supplies Source Voltage: 85-64 Volts AC Frequency Range: 47-63 Hz Certifications CE RoHS Compliant Physical Dimensions (H x W x D).75 x 9.00 x.75 in (4.45 x 48.6 x 53.35 cm) Weight 7.00 lbs 3.8 kgs Environmental Operating Temperature: 3 to 04 F (0 to 40 C) Storage Temperature: - to 49 F (-30 to 65 C) Humidity: 5 to 90% non-condensing WarrantY One () Year Limited Warranty (Support Contract Required) order information FSS-000BT FSS-000SX FSS-000LX SFP-SX SFP-LX S-FSS-000 Filtered singlestream link Aggregation tap (BT to BT) Filtered singlestream link Aggregation tap (SX to SFP) Filtered singlestream link Aggregation tap (LX to SFP) SX Gigabit Small form Pluggable SX Gigabit Small form Pluggable One () Year Hardware and Software Support 9 Adler Drive East Syracuse, NY 3057 (T) 35.463.954 (F) 35.463.9557 datacomsystems.com Datacom Systems Inc. Copyright 99-009. All rights reserved. 49

SINGLEstream Port SPAN Aggregation Tap (SS-00) Optional 3-Unit Rack Mount T e c h n i c a l S p e c i f i c at i o n s Datacom Systems SINGLEstream 00 Series SPAN Aggregation Tap provides a secure solution for combining the network traffic from two SPAN ports into one single stream of data. Connect up to two network monitoring devices to the SINGLEstream SPAN Aggregation Tap to monitor the combined full duplex traffic from both of the tapped SPAN Ports. Connect any compatible device (protocol analyzers, probes, intrusion detection system, more) for permanent In-Line monitoring of SPAN Ports - eliminates the need for network connectors to be disconnected and connected each time a segment needs to be monitored Multiple monitor ports allows extra devices to simultaneously monitor the same SPAN Port, providing extended security and analysis options, while eliminating contention for network access Redundant power supply insures seamless monitoring even if the main power source is unavailable Ports Two () 0/00 SPAN (RJ45) Network Connections Two () 0/00 (RJ45) Tap/Monitoring Connections Power Requirements Two () (External AC Adapters Included) Input: 00-40 VAC, 50-60 Hz, 0.4A - 0.A Output: 5 VDC, A Physical Dimensions (H x W x D).07 x 5 x 5 in.7 x.7 x.7 cm Weight oz..34 kgs. Environmental Operating Temperature: 0 to 40 C Storage Temperature: -30 to 65 C Humidity: Less than 95 C Non-Condensing Warranty -Year Limited Warranty Ordering Information Port In: Port Out: SS-00-0/00-0/00 SS-0-00MB - 00MB SS-0** - 0/00-0/00 SS-03** - 00MB - 00MB ** Includes TCP Resets RMC-3 RMC-4 3 Tap U Rack Mount Chassis 4 Tap 4U Rack Mount Chassis ACCESS YOUR NETWORK 9 Adler Drive East Syracuse, NY 3057 T: (35) 463-954 F: (35) 463-9557 DatacomSystems.com Datacom Systems Inc. Copyright 99-007. All rights reserved. 50

You Can t Monitor What You Can t See SINGLEstream Dual Link Aggregation Tap (LX) with 6 - SFP Monitoring Ports SS-0LX-SFP Full-Duplex Visibility for Two () In-Line Network Links even with Single Interface Monitoring Solutions Aggregation Monitoring full duplex network traffic from multiple sources is often a critical requirement for network monitoring applications. For example, in order to properly monitor redundant networks or a pair of load balanced links, network professionals might need to receive traffic simultaneously from two different network segments. In some cases, two network links may be bound together and operate as one logical network in order to improve bandwidth. In such an implementation, packets are distributed across two different physical links. Often, traffic transmits on one segment and receives on another. This makes network analysis and monitoring especially challenging. If an analyzer or monitoring device is put on only one physical link, it will not see the entire conversation Also, while traditional taps might enable fullduplex monitoring of all traffic on a network link, they transmit the data to the connected monitoring device in two separate half-duplex streams (one for Tx and one for Rx). Not only does this require the monitoring device to have two network interface cards, it also requires that the device be capable of combining and processing both streams of data in order to monitor both sides of the conversation. Not all monitoring systems have the required hardware to aggregate traffic. The SINGLEstream Dual Link Aggregation Tap has two () network taps. Each tap combines both directions of a full duplex data stream and allows connected monitoring devices, even those with only one NIC, to receive a copy of all the data collected from both taps in a single trace file. Totally Passive and Power Fault Tolerant Fiber taps are completely passive devices and are not a point of failure on the network. Even if power is lost to the tap, the network traffic will not be affected. If one side of the link fails for any reason, the device on the other side of the link will recognize this outage immediately, so routers and switches can engage redundant protocols and failover systems. Because both sides of the link are always open, the network will automatically re-establish the primary link as soon as both sides of the network and the endpoint devices become operational. Regeneration One-to-Many configurations replicate copies of identical network traffic to provide multiple tools monitoring access to the same links. In addition to eliminating contention for access to critical links, multiple tools can be connected to the same link for redundancy, testing, or advanced monitoring applications. Any of the SS-0LX-SFP s six (6) any-to-any ports can be configured as input (network) or output (monitoring) ports on the fly through easy to use command line interface (CLI). Any monitoring port can receive traffic from any of the other ports, eliminating the need for network managers to change complex network configurations or move tools around their network. Additionally, the any-to-any ports can be configured to receive data from a switch s SPAN port providing the flexibility of a combined in-line and out-of-band monitoring solution. 5 Benefits View entire full-duplex conversations even across redundant or load balanced links using single-interface monitoring tools Save money by reducing number of required tools or tool interfaces necessary to monitor all your data Decreased reliance on switch resources for network management visibility - eliminate SPAN port contention, oversubscription, and configuration errors After installation, deploy tools right away without impacting your production network Single point of deployment and remote management minimizes management expenses and reduces MTTR Automatic coverage of redundant network - One tool can monitor two networks Features Aggregation - Receive copies of multiple network links or channels into one stream for visibility into complete network conversations 00% Network Uptime - Single mode fiber tap is completely passive and won t disrupt the network even if power is lost to the tap Regeneration - Send copies of traffic from the tap to multiple connected tools to share data sources Monitoring Port Speeds from 0 to 000MB; full duplex, half duplex, or auto-negotiate SFP Flexibility - monitor fiber links with copper tools Flexible traffic flow to monitoring tools - single-direction or bidirectional for traffic injection Dual Redundant Power ensures monitoring uptime