SAFETY INSTRUCTIONS WARNING DANGER CAUTION

Similar documents
Updating the DSC-60 Software

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

TECHNICAL MANUAL SAILOR SYSTEM 5000 GMDSS CONSOLE

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

FLP-PS DC Power Supply Model. Portable Sound System Mixer Amp/ Pre Amp/ Power Amp

A3 GMDSS CONSOLE DEALERS MANUAL

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

4170 POS System Installation Guide

2260B-RMK-Series Rack Mount Kit

Manual Control Unit GFC 32

Manual Control Unit GFC 16

Modified Sinewave Series. Power Inverter 1000/1500 MW 1210, MW1215. True Sinewave Power Inverter 1000/2000 SW 1210, SW 1220.

Manual Simatek Control Unit GFC 32

True Sinewave Power Inverter 1000W & 2000W 230V , Owner s Manual

16-SLOT IN-BAND MANAGEMENT CHASSIS

MEMORY CARD INTERFACE UNIT CU-300

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Installation Job Aid for Ethernet Routing Switch 3600 Series

Analog Input Installation Manual

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Model 2380 Rack-Mount Kit

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

LVDT Test Device. Product Manual (Revision B) Original Instructions. Testing and Calibration of LVDT Feedback Devices on PG Governors

Model 2380 Rack-Mount Kit

Analog Monitor Installation Manual

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Installation Job Aid for VSP 4850GTS

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Installation Job Aid for VSP 4450GTX-HT- PWR+

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

InView Communication Modules

Overview. Features CHAPTER

Coastal GMDSS Sea Area А1 Marinsys-GMDSS system. Doc. number: _Ed. 1_Rev. A Data: May 2017 г. MARCOM INTEGRALES DE SISTEMAS, S.L.

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Model 2657A-LIM-3 LO Interconnect Module

Switched Mode Power Supply Operating manual PAP800

Neets Switching Relay - 2. Installation manual

User's Guide. Model W 3-in-1 Switching DC Power Supply

Installation Job Aid for Ethernet Routing Switch 5900 Series

PS/IO Circuit Board Retrofit

S66 Series Electronic Fan Speed Control

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

A120 A W/240W PA Mixer-Amplifier 70V/100V

Installation Instructions

SIMATIC VPU Hardware Manual. Order Number: PPX:560/ Manual Assembly Number: Second Edition

PLC Racks IC697CHS782/783

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

HT2000 Transverter Installation & Operation Manual

Input Power Selector Switch. Product Manual (Revision NEW) Original Instructions for use with Generator Set Control Assembly

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Installation and Maintenance

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

PCT2000. User Manual. Precision current transducer 2000 A

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

DS-1H05 Ethernet-over-Coax Extender. User Manual

Model HM-535 Power Supply Installation and Service Instructions

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

IBM. Rack Installation Instructions

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

TRC-190 User s Manual

3190 Series Touch Screen POS Workstation

Nokeval. FD100 series. User Manual

1-36V, 0-3A DC Power Supply

SQ405 Controller CAUTION. The caution messages are displayed before procedures which, if not followed, could cause damage to the equipment.

iconverter 2-Module Power Chassis

Installing the IPS 4345 and IPS 4360

TRC-190 User s Manual

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

PV Rapid Shutdown device

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Configuration. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv)

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

FHOTON WI-FI MODULE Owner's Manual

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Scanner 2000 Steam Mass Flow Transmitter

High Precision Quad Output DC Power Supply

Manual. Network Expansion Port 2 NEP-2. English. Brands by Navico - Leader in Marine Electronics

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Transcription:

SAFETY INSTRUCTIONS DANGER Do not work inside the equipment unless totally familiar with electrical circuits. Hazardous voltage which will cause death or serious injury exists at the following locations: Transceiver unit Antenna and antenna coupler (both at TX) WARNING Turn off the power at the mains switchboard before beginning at installation. Post a sign near the switch to indicate it should not be turned on while the equipment is being installed. Fire, electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed. Use only the supplied cables. HAZARDOUS VOLTAGE is present at these points. Use of other cables can result in fire or serious equipment damage. Use the correct fuse. Use of wrong fuse can cause fire. ANTENNA COUPLER CAUTION Ground the equipment to prevent electrical shock and mutual interference. When using a copper plate for ground be careful of its edges. Edges can cut fingers. If the distress alert is accidentally transmitted, transmit appropriate message to nearest coast station to cancel the distress alert. i

Table of Contents Page 1. Rack Console Chassis (RC-1500-1T)... 1 2. AC/DC Power Supply and Battery Charger... 3 3. Connection... 5 4. Adjustment at Installation...10 Outline Drawings...D-1 System Diagram... S-1 Schematic Diagram... S-3 ii

1. Rack Console chassis (RC-1500-1T) General The RC-1500 series Radio Console comes in five models: RC-1500-1T-150/250, RC-1500-1T-400/800, RC-1500-1T-2P, and RC-1500-1T-TOKU. The type and number of components incorporated differs from model to model, however each model contains an Inmarsat-C mobile earth station, NBDP terminal, DSC terminal, DSC watch receiver, and SSB radiotelephone. Below are the distinguishing characteristics of each model. RC-1500-1T-150/250: Incorporates the FS-1562-15/1562-25 SSB radiotelephone. RC-1500-1T-400/800: Incorporates the FS-5000/8000 SSB radiotelephone. RC-1500-1T-2P: Russian model. RC-1500-2T: Incorporates the FM-8500 VHF radiotelephone. RC-1500-1T-TOKU: Special order model. Mounting considerations (tabletop mount) When selecting a mounting location; Make sure the location is strong enough to support the unit (about 100 kg) under the conditions of continued vibration and shock normally encountered on the vessel. Where necessary, reinforce the mounting location by lining block or doubling plate. Locate the unit where it is easily accessible and does not interfere with personnel or operation of other equipment; for example, ship s wheel. Select a location where temperature and humidity are moderate and stable. 1

Mounting The mounting dimensions of the RC-1500-1T are as shown in the figure below. (Refer to the outline drawing attached to the end of this manual for further details.) PP-510 80 950 630 Bottom Cable Entry Hanger MAX 735 530 Keyboard Rack consaole chassis (Top View) Unit: mm MIN 270 530 Side view 120 Rear cable gland Unit: mm Before mounting the unit, determine location of cable gland. The interconnection cable should be run though either the rear or bottom side of the rack console chassis. See the outline drawing attached for further details. Procedure 1. Place the rack console chassis on the tabletop. 2. Mount three hangers for the DSC-6, AA-50 and FS-1562 as shown above. 3. Set the DSC-6, AA-50 and FS-1562 (only 150W type or 250W type) to the hangers with knobs. Set the FM-8500 to the hanger with knobs (only RC-1500-2T). 4. Mount the two printers PP-510 and printer selector to the top of the console chassis. 5. Place the NBDP and FS-5000 on the tabletop (only 400W type). 6. Place the Inmarsat C outside of rack console. 2

2. AC/DC Power Supply and Battery Charger Mounting considerations The unit can be mounted almost anywhere provided the location satisfies the following requirements. Vibration-free location Well-ventilated area Free of water splash Leave enough space around the sides of the unit to permit maintenance and checking. The mounting location must be able to support the weight of the unit (PR-850A: 35 kg, PR-300: 14.5 kg, BC-6158/6200: 28 kg, S-5300A/8300A: 85/110 kg) under the condition of continued vibration normally encountered aboard the vessel. Mounting Refer to the outline drawing attached to the end of this manual for further details. PR-850A 250 AC IN 352 Cable terminal 440 55 120 120 55 DC IN DC OUT Cable terminal 6- φ6 Fixing holes Front view 233 PR-300 370 Top view 270 Unit: mm 4- φ6 Fixing holes 163 350 230 290 Front view Top view Cable terminal 3

BC-6158/6200 490 360 4- φ7 Fixing holes 200 510 360 490 Front view Top view S-8300A 2x φ15 400 Fixing holes Service space 100 Service space 100 Air Vent 875 890 Air Vent 850 Rear cable gland A Air Vent 25 520 Front view 4x φ15 Fixing holes 520 Side view Unit: mm 450 Bottom cable gland 520 TB1 TB2 TB3 45 80 360 80 View from A 45 Fasten the S-8300A to the mounting location by fixing four fixing screws (φ15) at the bottom and two fixing screws (φ15) at the top. The interconnection cable between the S-8300A and the rack console chassis should be run through either the bottom or rear side of the S- 8300A as shown above. 4

3. Connection The figure belows shows view of rack console chassis. Remove the cover access terminal boards to make connections. TB1 TB2 TB3 Front Cover Screw Remove cover to access three terminal boards, TB1, TB2 and TB3. TB1 1... 12 Remove jumper wires between TB2 and TB3. TB2 TB3 1... 11 12 1 2... 12 See next page. Connect cables to the AC/DC Power Supply Unit. 5

AC/DC POWER SUPPLY TYPE EMERGENCYL CHARGER ONL (+) (-) (+) (-) (+) (-) (+) (-) Battery TB2 (H) (C) TB1 ACIN ACIN 1 2 1 2 TB1 1 2 3 4 5 6 7 8 9 10 11 12 DPYC-38 DPYC-1.25 DPYC-5.5 DPYC-3.8 DPYC-3.5 DPYC-8 CHARGER SOURCE 100-120/200-240 VAC 1φ, 50/60Hz No.1 MAIN SOURCE 100-120/200-240VAC 1φ, 50/60Hz TB3 1 2 3 4 5 6 7 8 9 10 11 12 DPYC-5.5 DPYC-5.5 AC-FAIL TB3 TB3 (L) (N) F. G. TB1 DPYC-3.5 (L) (N) F. G. AC-DC POWER SUPPLY PR-850A No.2 MAIN SOURCE 100-120/200-240VAC 1φ, 50/60Hz AC-DC POWER SUPPLY PR-300 ALL CABLES SHIPYARD SUPPLY BATT.(1) CHARGE(1) 24V(1) 24V(2) 1 2 1 2 (+) (-) TB2 (+) TB3 (H) (C) (H) (C) (+) 24V CHARGE 1 2 3 4 5 6 DPYC-5.5 1 4...... (+) (-) DC-OUT TB2 (+) (-) BATT (-) DC-OUT BATT AC-IN TB1 6

AC/DC RADIO SWITCH BOX TYPE GND (U) (V) MAIN SOURCE RADIO BATT 24VDC-OUT AC-FAIL CHARGE BTT DC-OUT (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) EMERGENCYL CHARGERONL (+) (-) BATT(1) (+) (-) CHARGER(1) (+) (-) 24V(1) BATTERY TB1 1 2 3 4 5 6 7 8 9 10 11 12 TB2 1 2 3 4 5 6 7 8 9 1011 12 TB3 1 2 3 4 5 6 7 8 9 1011 12 DPYC-5.5 DPYC-5.5 DPYC-38 DPYC-5.5 DPYC-38 TPYC-1.25 DPYC-3.5 TB2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 TB1 1 2 3 TB2 1 2 TB3 1 2 (L)(N) F.G TB2 1 2 3 S-5300A/8300A AC/DC RADIO SWITCH BOX PR-300 AC-DC POWER SUPPLY No.2 MAIN SOURCE 100-120/200-240VAC, 1φ, 50/60Hz DPYC-8 No.1 MAIN SOURCE 100-120/200-240VAC, 1 φ, 50/60Hz ALL CABLES SHIPYARD SUPPLY 7

Connect cables with connectors in the rack console chassis among the equipment. RC-1500-1T-150/250, RC-1500-2T type TO PRINTER SELECTOR PRINTER ANTENNA OPTION FOR POWER DC24V FOR POWER MF/HF DSC DMC-5 (option) FOR POWER DC24V POWER DMC POWER NBDP REMOTE B PRINTER DSC-6 NBDP REMOTE B DP-6 MH-HF RX NMEA REMOTE A NMEA MF-HF RX CO-2P (*1) REMOTE A DSC TB6 TB7 TB5 DISTRIBUTION PCB (05P0606) TB7 TB3 TB7 TB4 NMEA DSC NMEA IN TO-IC-212 (Inmarsat C) ANT AA-50 MF-HF TR POWER MF-HF TR REMOTE DC24V FS-1562 REMOTE POWER FOR POWER ANT H.P.A DC24V PRINTER IB-581 TERMINAL SERIAL TO PRINTER SELECTOR (*1):Shipyard supply FOR POWER :Labels on the connectors from rack console chassis RC-1500-1T-400/800, RC-1500-1T-2P type TO PRINTER SELECTOR PRINTER ANTENNA OPTION FOR POWER FOR POWER DC24V MF/HF DSC DMC-5 (option) POWER PRINTER DSC-6 DMC NBDP NBDP REMOTE B MH-HF RX NMEA NMEA NMEA MF-HF RX CO-2P (*1) DSC NMEA IN DSC TB6 TB7 TB7 DISTRIBUTION PCB (05P0606) TB7 TB7 ANT AA-50 POWER MF-HF TR MF-HF TR REM1 NMEA DC24V REM1 NMEA FS-5000C FOR POWER MAIN FOR FS-5000T REMOTE B TO-IC-212 (Inmarsat C) REM3 POWER FOR POWER DC24V TERMINAL POWER DP-6 REMOTE A REMOTE A DC24V FOR POWER PRINTER IB-581 SERIAL TO PRINTER SELECTOR (*1):Shipyard supply :Labels on the connectors from rack console chassis 8

IC-302 DISTRESS ALERT UNIT TO DISTRIBUTION PCB DMC NMEA FOR POWER DC24V Inmarsat C TERMINAL UNIT (IB-581) REMOTE A PRINTER SERIAL DTE1 DMC Inmarsat C COMMUNICATION UNIT (IC-212) PRINTER DC24V FOR POWER TO DSC-6 TO DP-5/6 PRINTER DSC NBDP TO DISTRIBUTOR FOR PRINTER SELECTOR POWER PP-510 PP-510 DC24V PRINTER DC24V FOR POWER PRINTER PRINTER Distribution PCB TB1 +9V 1 GND 2 POWER CABLE 9V Printer Selector TB2 +24V 0V 1 2 FOR POWER TB6 NMEA-IN-H NMEA-IN-C 1 2 C0-0. 2x2P NMEA IN 05P0606 9

4. Adjustment at Installation 1. SSB Radiotelephone For FS-1562 Register permitted frequency and change system setting if necessary, referring to the Service Manual SME-5572. For FS-5000 Register permitted frequency and change system setting if necessary, referring to the Service Manual SME-5519. 2. DP-6 To change the system setting and conduct self-test, refer to the Operator s Manual OME-5610. 3. FELCOM 12 To carry out log-in and set the system setting, refer to Installation Manual IME-5613 and Operator s Manual OME-5613. 4. DSC-6 To set the system setting and conduct self-test, refer to the Operator s Manual and Installation Manual. 5. PP-510 Set a recording paper and a cartridge and carry out self-test, referring to Operator s Manual OME-5080. 6. DMC-5 (option) To set the system setting, refer to Operator s Manual OME-5544. To check the printer selector, transmit data from the DSC-6 and the NBDP and confirm that it is printed correctly. 10