Improved Efficiency for Multi-Technology Inspections (UT and ECT)

Similar documents
Developments in Ultrasonic Phased Array Inspection IV

Riser Bolt Inspection

Applications Group; Zetec, zndt Solutions, Québec; Phone: ;

Simulation in NDT. Online Workshop in in September Software Tools for the Design of Phased Array UT Inspection Techniques

High Resolution Phased Array Imaging using the Total Focusing Method

Shaft inspection using Phased-Array compared to other techniques

DEVELOPMENT AND VALIDATION OF A FULL MATRIX CAPTURE SOLUTION. Patrick Tremblay, Daniel Richard ZETEC, Canada

High Resolution Phased Array Imaging using the Total Focusing Method

PORTABLE PHASED-ARRAY ULTRASOUND FULL-FEATURED SYSTEM

TC5700 TUBE INSPECTION SYSTEM

Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array

Phased Array Assisted Manual Nozzle Inspection Solution with Data Archiving Capability

EDDY CURRENT ARRAYS. A major leap for reliable measurements over conventional surface NDT methods used in aerospace industry.

ScanMaster. Aluminum Plate Inspection Using Phased Array Technology

2. Equipment, specimens and inspection procedures

Developing an Ultrasonic NDE System for a Research Reactor Tank

Vajira Jayasinghe, Chris Eaton, & Brian Millejours. Application of Flexible PAUT probes for small diameter FAC elbow inspection II

In partnership with.

Impact of 3D Laser Data Resolution and Accuracy on Pipeline Dents Strain Analysis

ADVANCED PHASED ARRAY TECHNOLOGIES

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada

ULTRAVISION 3.7R21. Product Bulletin. UltraVision, a complete UT and Phased Array inspection package!

Ultrasonic Detection and Sizing of Off-Axis Flaws in Pressure Tubes. Alex Karpelson. 3rd International COG/CINDE In-Service Inspection NDE Conference

SLOFEC TANK FLOOR INSPECTION REPORT

Shaft Inspection using Phased Array Compared to other Techniques

S. Galošić, T. Tomašić, I. Vuković, A. Bakić, INETEC,Croatia

Automatic analysis and weld indications classification on TFM acquisitions

ADVANCED METHOD FOR ULTRASONIC PROBE CHARACTERIZATION

John R. Mandeville Senior Consultant NDICS, Norwich, CT Jesse A. Skramstad President - NDT Solutions Inc., New Richmond, WI

SURFACE ARRAY AND TUBE INSPECTION SYSTEM. High performance Multi-technology User-centered

Adaptive Focusing Technology for the Inspection of Variable Geometry. Composite Material

Other Major Component Inspection I

Flexible EC Array Probe for the Inspection of Complex Parts Developed Within the European VERDICT Project

ULTRAVISION 3.8R13. Technical Guidelines. UltraVision, a complete UT and Phased Array inspection package!

TRULY AFFORDABLE EDDY CURRENT

M2M GEKKO. State-of-the-art phased-array flaw detector with TFM

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE

SIGNAL PROCESSING ADVANCEMENTS FOR CASS UT EXAMINATIONS. T. Seuaciuc-Osório, M. Dennis, D. MacDonald, EPRI, USA D. Braconnier, D.B. Ltd.

Application of a 3D Laser Inspection Method for Surface Corrosion on a Spherical Pressure Vessel

Hand-held Fully Featured Eddy Current Flaw Detector ET NDE

Application of portable modules for fatigue crack characterization

SMALL SIZE. BIG VALUE. TOPAZ 16 BEST IN CLASS FULLY INTEGRATED 16 CHANNEL PHASED ARRAY UT DEVICE.

True Advancements for Longitudinal Weld Pipe Inspection in PA

Sizing in Phased Array Technique using Diffraction and Amplitude Displacement

Phased-array applications for aircraft maintenance: fastener-hole inspection

GE Sensing & Inspection Technologies. Apollo. Multi-Channel/Multi-Frequency Eddy Current System

Advanced ultrasonic 2D Phased-array probes

Magnetic Field Mapping System MMS-1-RS KEY FEATURES:

Results of the New Eddy Current Tester for Steam Generator Applications

Robot-Based Solutions for NDT Inspections: Integration of Laser Ultrasonics and Air Coupled Ultrasounds for Aeronautical Components

QUALIFICATION OF A BUTT-WELD INSPECTION USING PHASED ARRAY IN LIEU OF RADIOGRAPHY

MANTIS Compact Phased Array Ultrasonic (PAUT) Flaw Detector featuring TFM, TOFD and Conventional UT

Portable Phased Array Applications

TOPAZ 32 FULLY INTEGRATED PHASED ARRAY UT DEVICE WITH MULTI-TOUCH SCREEN PERFORMANCE AND PRODUCTIVITY REDEFINED

Immersion Scanning Systems

ARTICLE 4 ULTRASONIC EXAMINATION METHODS FOR WELDS

UltraVision TOUCH 3.8R11

ARIA Software. Total Focusing Method. - Real-Time TFM Imaging - Acquire all FMC data - FMC/TFM Wizard - TFM Viewer - Analysis Mode

When speed matters.

ULTRASONIC FLAW DETECTOR SONOSCREEN ST10 FOR NONDESTRUCTIVE TESTING MADE IN GERMANY

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE

Contents. Introduction... iii. CHAPTER 1 - Getting Started... 5

Test probes for non-destructive crack detection using eddy-current method. Individual probes for permanent installation into a test station

ULTRASONIC INSPECT ABILITY MODELS FOR JET ENGINE FORGINGS

LaserFleX New Generation of High Performance Infrastructure Measurement System

3D modeling and experimental validation of flaw responses provided by Magnetic Flux Leakage NDT system inspecting ferromagnetic pipes

VALIDATION OF THE SIMULATION SOFTWARE CIVA UT IN SEPARATED TRANSMIT/RECEIVE CONFIGURATIONS

Recent advances in aerospace inspection with ultrasonic phased arrays

ULTRASONIC FLAW DETECTOR SONOSCREEN ST10 FOR NONDESTRUCTIVE TESTING MADE IN GERMANY

ED-1100 PORTABLE VARIABLE EDDY CURRENT INSTRUMENT

Simulation of ultrasonic guided wave inspection in CIVA software platform

Applications of Phased Array Techniques to NDT of Industrial Structures

UMASIS, an analysis and visualization tool for developing and optimizing ultrasonic inspection techniques

Automated Eddy Current Inspections of Complex, Irregular Surfaces

Advanced Ultrasonic. Proceq Flaw Detector 100. Proceq Flaw Detector 100. Interactive

UT phased array inspection of turbines

Comparison Corrosion Mapping Solutions using Phased Array, Conventional UT and 3D scanners

AFCS. Jesse Skramstad NDT Solutions, Inc.

SIZING THE HEIGHT OF DISCONTINUITIES, THEIR CHARACTERISATION IN PLANAR / VOLUMETRIC BY PHASED ARRAY TECHNIQUE BASED ON DIFFRACTED ECHOES

Pomini Tenova sold its first-generation roll inspection

Pomini Tenova sold its first-generation roll inspection

2. Combination of eddy current inspection and imaging analysis

Automatic Ultrasonic testing for Metal Deposition

VALIDATION 3D RAY TRACING FOR UT EXAMINATION OF THE NOZZLE

MIZ-21C Software Product Bulletin

UltraVision TOUCH 3.8R16

REACTOR PRESSURE VESSEL FLANGE SEALING SURFACES PROFILOMETRY SYSTEM

3D SCANNING SOLUTION FOR PIPELINE INTEGRIT Y ASSESSMENT!

3D 3D SCANNING SOLUTION FOR FOR PIPELINE INTEGRITY ASSESSMENT

ULTRASONIC NONDESTRUCTIVE TESTING OF COMPLEX COMPONENTS WITH FLEXIBLE PHASED-ARRAY TRANSDUCERS

Regional Contact Information

Simulation Supported POD Methodology and Validation for Automated Eddy Current Procedures

A FLEXIBLE PHASED ARRAY TRANSDUCER FOR CONTACT EXAMINATION OF COMPONENTS WITH COMPLEX GEOMETRY

UltraVision 3. Technical Guidelines Release 3.8R30.

High-End Ultrasonic Phased-Array System for Automatic Inspections

3D INTELLIGENDT MODELING AND VISUALIZATION SOFTWARE FOR UT INSPECTIONS OF COMPLEX GEOMETRIES

Minimize your cost for Phased Array and TOFD

Research on Correction and Optimization of Post-processing Imaging of Structure with Non-planar Interface Using Full Matrix Data of Ultrasonic Array

EDM LASER STEM Drilling

Developments in Ultrasonic Phased Array Inspection II

Transcription:

Improved Efficiency for Multi-Technology Inspections (UT and ECT) More info about this article: http://www.ndt.net/?id=22727 Abstract Michaël Monette 1, Lance Maggy 2, Yannick Bellerive 3 Dirk Verspeelt 4, Frédéric Laprise 5 1 Zetec, Québec, Canada, mmonette@zetec.com 2 Zetec, Snoqualmie, USA, lmaggy@zetec.com 3 Zetec, Québec, Canada, ybellerive@zetec.com 4 Zetec, Québec, Canada, dverspeelt@zetec.com 5 Zetec, Québec, Canada, flaprise@zetec.com Mission-critical NDT inspections of components and equipment in power generating plants often require both surface examination and complete volumetric examination of the considered components. Obviously, permanent data records are a key requirement for such inspections. Conventional or phased array UT technology is preferred over RT as the volumetric inspection technique, because it is non-disruptive to other activities, and for its superior inspection capability. Although PT or MT can be used for surface examination, Eddy Current Array (ECA) technology is an obvious trade-up, because it provides permanent data records. It is easy to deploy one or more ECA probes and UT probes on a common scanning mechanism. Unfortunately, the combined implementation of the two techniques can be laborious, because it often requires different testers ran by different software. This paper will explain how a single comprehensive software package can streamline the inspection process, by simultaneously driving best-in-class UT and ECA systems from a single computer, and collect examination data from both inspection technologies. Application examples (e.g. rotor bore inspection) will illustrate the value of this solution. Dedicated data analysis features for both inspection technologies are presented, and the benefits of a single software platform for data imaging, evaluation and reporting are demonstrated. 1 Introduction Rotating items such as turbine shafts, generator rotors and alternator end rings, made of steel with different alloying elements depending upon the required mechanical properties, are susceptible to metallurgical degradation processes due to the high stress during start up and shut down as well as during operation. These critical components are submitted to periodic in-service examinations in order to assure the integrity necessary for safe operation and for minimizing loss of production. 1

Mechanized Eddy current surface and ultrasonic volumetric techniques, both offering permanent data records, are applied for this purpose since many years. Volumetric examination using the ultrasound technique (UT) is typically performed by moving the probes following a given pattern while acquiring the data at discrete locations. The minimum distance between the locations are mostly based upon the size of the ultrasonic beam and on examination performance requirements. Due to the ability of covering a given surface, the Eddy current array (ECA) technique can be designed to cope with the acquisition steps defined by the ultrasound technique. This allows for a simultaneous deployment of both examination methods on the same mechanical device. Up to date the combined implementation of the two mentioned techniques requires two different software packages, each one dedicated to a specific method, resulting in a laborious and inefficient solution susceptible to operator frustration and errors, and consequently loss of time. The next paragraphs will, based upon a turnkey solution for turbine bore examinations, describe how a single comprehensive software package, UltraVision ECA, can streamline the inspection process by simultaneously driving best-in-class UT and ECA systems from a single computer. The UltraVision ECA software is used for set-up and calibration of the UT and ECA technologies as well as for collection and analysis of the examination data from both inspection methods. 2 Turbine Shaft Examination 2.1 Context Many turbine shafts in service were manufactured in a period when forging techniques were not as sophisticated as the present methods. Impurities and inclusions migrating towards the centre during the forging process were removed by machining a bore through the centre and consequently minimising the risk of crack initiation (Figure 1). This approach shows to be effective but cannot exclude that still some discontinuities can occur around the bore and possibly grow during operation. Figure 1: Typical turbine shaft with centre bore (upper image) and scanning principle (lower image) 2

Making use of the bore, an inspection head allows for, from the centre of the shaft, performing eddy current and ultrasonic inspections on the bore surface, near surface, and far surface allowing detection of flaws initiated by possible discontinuities. A rotating probe head fitted with ultrasound and eddy current probes is introduced in the bore. In combination with an axial movement of the head, the probes describe a helicoidally pattern with a given pitch on the inside bore surface as shown in Figure 1. 2.2 UT method The applied UT method is usually based upon angle beam shear wave and straight beam longitudinal wave examination. Shear wave beams with different refracted angles and orientations are applied to detect the most critical flaws. The figures below show a typical setup. Two 60 SW beams pointing axially forward and backward are applied for detection of conferential oriented flaws. The zero degree inspection is done by two transmit-receive straight beam probes for coverage of sub-surface zone and the far surface zone. Two 45 SW probes are used for detection of axially oriented flaws. Figure 2: UT method, 2 x 60deg Axial, 2 x 0deg Near & Far field, 2 x 45deg circumferential 2.3 EC method The EC surface inspection method is based upon the implementation of an array of absolute EC coils. The rotor bore ECT array probe contains seven absolute pancake coils of 3mm diameter staggered on three rows in a way to allow a very fine resolution on defects with various orientations. The frequency ranges from 100 khz to 500 khz. The probe housing curvature is adjusted to a given bore diameter range to reduce lift off variations as much as possible. The probe design allows for a maximal axial pitch of 6.0 mm without overlapping. The probes are intended to detect axial, circumferential, 45 and 135 notches with a minimum length of 1 mm, a depth of 0.5 mm and a width of 0.15 mm. 3

3 The inspection system 3.1 Scanning mechanism A cylindrical inspection head is deployed by means of a TSIS (Phoenix ISL, UK) scanning mechanism (Figure 3). Figure 3: TSIS scanning mechanism, inspection head and probe head detail An adaptable frame allows fixing the system to the shaft. A linear movement drives the inspection head into the bore. As the amplitude of the linear movement is limited (a linear drive having the complete length of the shaft would be very cumbersome), multiple drive rods are inserted during the inspection to move the inspection head towards the end of the bore. The inspection head has spring-loaded centering devices and provides for a local rotation of two legs fitted with probe heads which include UT and ECA transducers. Since the probe heads rotate in relation to the inspection head main body, slip rings are used to transfer the UT and ECA signals towards the acquisition systems. As electrical crosstalk is a known issue related to slip rings, local preamplifiers increase the level of the UT signals before passing through the slip rings improving the signal-to-noise level. The inspection head is connected to the UT and ECA equipment through a long umbilical cable conducting the UT, ECA and motor drive and encoder signals as well as a plastic hose for transporting the liquid required for the coupling of the UT probes to the bore surface. 3.2 Instruments A Zetec Z-Scan UT unit is used for UT data acquisition. It is a powerful, flexible, and compact multi-channel conventional UT acquisition system for high-end applications. It easily integrates with all Zetec and many commercially available scanners. The Eddy current inspection is performed with a Zetec MIZ-200A ECA unit. It is a fully portable, battery operated, remote data acquisition unit delivering significant benefits including an industry leading signal to noise ratio to improve probability of detection in industrial environments. Designed with operator ease of use in mind, the MIZ-200 automatically recognizes the probe type connected to it and configures its internal multiplexor accordingly. 4

The MIZ-200 Eddy current instrument can handle the most demanding environments with ease. Offered in both tubing and surface array configurations, MIZ-200 is ideal for applications within Balance-of-Plant/Power Generation, Transportation and Oil and Gas markets. The motor steering of the mechanical system is performed by a Zetec ZMC 2 motor controller. It is a small lightweight, and versatile 2-axis DC motor drive unit with builtin controller. It supports both single-axis and dual-axis scanning sequences. All the instruments are linked to a single PC through Ethernet connections. 3.3 Probes The probes are embedded in probe heads. Different probes are combined in a single head (Right image of Figure 3). Probe heads and probes are shaped to the curvature of the bore. As a result each head can cover a limited bore diameter range. Multiple head-sets with different shaping are applied to cope with the bore diameter ranges. 4 UltraVision ECA UltraVision ECA is used for setting up the inspection parameters, for data acquisition and for data analysis and reporting. Covering the many features of the UltraVision ECA software is not possible in the frame of this paper. Therefore only some typical aspects, required for the presently described application, will be highlighted. 4.1 Mechanical set up The bore inspection requires a typical helical scanning pattern (see 2.1). The pitch is obtained by a combination of the head rotation speed and the axial speed. Specific settings allowing easy steering of the scanner system are provided in a dedicated mechanical sequence. The required speed of the axial movement is automatically defined by the program on the basis of the pitch and head rotation speed specified by the operator. The inspection head is equipped with a sensor which detects when the head rotation is located at given physical reference position. This signal is used to set the rotation encoders to the reference position for each turn of the head. The software reads the sensor signal and applies the position of the reference at each revolution of the head. This avoids rotational position drift during the inspection of long bore lengths. 5

4.2 ECA setup UltraVision ECA provides different configuration windows to define the Eddy Current parameter settings such as probe and generator related parameters and multiple groups creation for C-Scan image build-up. 4.3 Data acquisition Multiple drive rods are used to move the probe head inside the bore. However, the axial encoder range is limited to the length of approximately 1 rod (see 3.1). This is taken into account by UltraVision. The data is acquired rod-by-rod and a data file is created for each section corresponding to the rod length. Automatic file naming referring to the rod number reduces operator errors. The acquisition process is controlled by the software which automatically takes into account the real axial position based upon the number of drive rods used. The UT and ECA data are acquired simultaneously and stored in a single UVData file. By this way the Ultrasound and ECA data are, for each data point, univocally linked to the same encoder positions. A specific layout showing the UT and the ECA data is used for monitoring the data during the acquisition. 4.4 Data analysis 4.4.1 UT data analysis Qualitative analysis is realized by using different views of the acquired data. Standard views such as Top, End and Side views allow viewing the data in a conventional way. The Polar view is used to display the indications in a front view of the bore making interpretation of the data much more user friendly (Figure 4, left image). Figure 4: Polar view and 3D data presentation of the indications 6

Polar cursors allow for defining the circumferential position as well as the depth position related to the bore surface of given indications. Depending upon settings, the Polar view shows the projection of all indications over the complete length of the bore or only of a given slice of the bore. UltraVision also has 3D view capability which can offer advantages for visualisation of the UT data, for example in case of complex geometries or during procedure development or for displaying the data in a comprehensive way to be shown to non-ut specialized people. The right image of Figure 4 above shows UT data obtained on a demonstration block with several artificial flaws. The 3D view gives an understandable view of the UT data and helps, for instance, discriminating the response of fixture holes from the intended artificial flaws. During the analysis process the operator can create a table containing all relevant information of the found indications. This table is automatically stored in an extension file and remains attached to the considered data file. It is available each time the data file is opened allowing different analysts, e.g. UT and ECT analysts, to use separate tables adapted to the specific requirements of each technique or to group the indications into a single table. The table can, together with typical detailed views of the indication, be printed out for documentation. Application specific calculations can be performed by using a dynamic Excel exchange tool. This tool allows for transferring UltraVision information, e.g. indication position and amplitude, to Excel and reading back the calculated fields from Excel (Figure 5). In this way it is possible to create user defined information fields. Once set-up the exchange process is totally transparent for the operator. This feature allows, as an example, to include in the indication table the theoretical calculated equivalent size of an indication using the DGS method. 4.4.2 EC data analysis Figure 5: UltraVision Excel link UltraVision ECA combines data analysis, display, and reporting in a user-friendly Windows-based environment. The program offers innovative features for sizing and locating flaws, and numerous ways of displaying data: Lissajous, strip charts, C scans and 3D C-scans. It offers channel scan calibration, possibility to filter C-Scan and channels as well as subtraction cursor on C-Scan. Figure 6 shows a combined analysis view of a 7

surface notch detected by ECA as well as UT. The left side shows the analysis of the UT data while the right side shows the ECA data analysed with typical EC windows: Figure 6: Analysis view showing combined analysis of UT and ECA data The indications found during the Eddy current analysis can, if desired, be added to the same indication list used for UT analysis. This process reduces human errors since it eliminates transcription of information from one application to another. A complete report combining both technologies is made available by simply printing out the indication table. An exporting tool also allows the creation of the table in an xml or a Microsoft XML database file format. 5 Conclusions By means of a typical bore inspection application example it has been shown that: A single software package can perform simultaneous ultrasound and Eddy current inspections Eddy current array probes, offering a large surface coverage, and ultrasound probes can be easily integrated on the same inspection head Ultrasound, Eddy current and motor steering equipment can be controlled by a single PC running a user friendly multi-technology software package UltraVision ECA offers dedicated set-up tools for the Ultrasound as well as for the Eddy current surface techniques A single data file assures that the acquired ECA and UT packets are unequivocally linked to the same physical position UltraVision ECA offers dedicated data analysis and reporting tools for ultrasound as well as for Eddy current techniques 8