Sarix Professional IMP Series 3.75 Indoor Dome Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)
Sarix Professional IJP Series 2 Micro Indoor Dome Quick Start Guide IJP121-1IS IJP221-1IS C2291M-A-EN (12/16)
Contents Contents... 3 Important Notices Statement... 5 Regulatory Notices... 5 Radio and Television Interference... 5 Korean Class A EMC... 5 Warranty Statement... 5 UL Safety Notices... 5 Models Instructions... 6 IMP Series 3.75 Indoor Dome... 6 IJP Series 2 Micro Indoor Dome... 6 Description... 7 IMP Series 3.75 Indoor Dome... 7 IJP Series 2 Micro Indoor Dome... 7 Package Contents... 7 IMP Series 3.75 Indoor Dome... 7 IJP Series 2 Micro Indoor Dome... 7 Optional Accessories... 7 IMP Series 3.75 Indoor Dome... 7 IJP Series 2 Micro Indoor Dome... 7 Installation - IMP Series 3.75 Indoor Dome... 8 In-Ceiling Flush Mount... 8 Wall Surface Mount... 10 Pendant Mount... 11 Position the Camera... 13 Adjusting the Focus... 13 Installation - IJP Series 2 Micro Indoor Dome... 14 Wall/Ceiling Surface Mount... 14 Surface Mount with IMPEBAP... 15 3
Wall Mount with IMPPMB-1I... 16 Positioning & Adjusting the Field of View... 17 Pelco Troubleshooting Contact Information... 18 Note for Dimension Drawings... 18 4
Important Notices Statement For information about Pelco s product-specific important notices and thereto related information, refer to www.pelco.com/legal. REGULATORY NOTICES This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules. CAN ICES-3(A)/NMB-3(A) Korean Class A EMC Warranty Statement For information about Pelco s product warranty and thereto related information, refer to www.pelco.com/warranty. UL SAFETY NOTICES The product is intended to be supplied by a Listed Power Unit marked "L.P.S." (or "Limited Power Source") and rated output 12Vdc/0.70A or 24Vac, 0.56A minimum or 48Vdc, 0.15A minimum. The product shall be installed by a qualified service person and the installation shall conform to all local codes. 5
Models Instructions IMP SERIES 3.75 INDOOR DOME The physical appearances and installation methods for the models indicated within the list below are, by and large, the same. Therefore, please use this quick guide where we use the example from IMP521-1IS as a reference to apply to all the varied models. Model IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS Description 1MP Indoor Dome with Vari-focal lens 2MP Indoor Dome with Vari-focal lens 3MP Indoor Dome with Vari-focal lens 5MP Indoor Dome with Vari-focal lens IJP SERIES 2 MICRO INDOOR DOME The physical appearances and installation methods for the IJP 2 Indoor models indicated within the list below are, by and large, the same. Therefore, please regard use manual where we use the example from IJP221-1IS as a reference to apply to all the models. Model IJP121-1IS IJP221-1IS Description 1MP 2 Micro Indoor Dome 2MP 2 Micro Indoor Dome 6
Description IMP SERIES 3.75 INDOOR DOME The Sarix Professional Series IP 3.75 Indoor Dome is ideal for indoor applications. Before installing it, please verify your model and read this guide carefully. IJP SERIES 2 MICRO INDOOR DOME The Sarix Professional Series IP 2 Micro Indoor Dome is ideal for indoor applications. Before installing it, please verify your model and read this guide carefully Package Contents IMP SERIES 3.75 INDOOR DOME 3.75 Indoor Dome camera * 1 Plastic Anchor * 4 Flat Head Screw (Tapping Type) * 4 T10 Security Torx Wrench * 1 Mounting Template * 2 Terminal Block * 1 Conduit Hole Plug * 1 Important Notices Declaration * 1 Printed Quick Start Guide * 1 Supplemental Resources Sheet * 1 Important Safety Instruction * 1 ROHS Statement Slip * 1 IJP SERIES 2 MICRO INDOOR DOME Fixed Indoor Dome Camera * 1 Plastic Anchor * 2 Flat Head Screw (Tapping Type) * 2 Mounting Template * 1 Important Notices Declaration * 1 Printed Quick Start Guide * 1 Supplemental Resources Sheet * 1 Important Safety Instruction * 1 ROHS Statement Slip * 1 Optional Accessories IMP SERIES 3.75 INDOOR DOME IMPICM-1l: In-ceiling wall mount, for use with the indoor dome models IMPPM-1l: Pendant adapter, for use with the indoor dome models IMPLD2-0I: Lower dome (smoked) IMPLD2-1I: Lower dome (clear) IJP SERIES 2 MICRO INDOOR DOME IMPEBAP: 4S electrical box adapter IMPPMB-1I: Wall mount bracket for micro indoor dome models 7
Installation - IMP Series 3.75 Indoor Dome Sarix Professional Series IP 3.75 Indoor Dome can be installed using the following methods. In-Ceiling Flush Mount (requires in-ceiling mounting kit) Wall Surface Mount Pendant mount (requires pendant mounting kit) IN-CEILING FLUSH MOUNT Install the indoor dome camera to an in-ceiling area as shown in the following procedure. 2 1 3 4 1. Utilize torx wrench to loosen the screws on lens base and top cover in order to disassemble the 3 parts of camera individually. 2. Connect the required cables (Ethernet and Alarm/Audio Input/Output threads) with the corresponding ports on rear side. The digital IO ports are described below: Alarm Out: Via Au/I and GND ports, connect to external device like microphone that receives sound for camera. Audio Out: Via Au/O and GND ports, connect to device like speaker to be triggered through alarm output signals. Alarm Out: Via COM and AO ports, connect to external device to be triggered through alarm output signals. Alarm In: Via GND and AI ports, connect to external device that can trigger alarm input signals. 8
3. Attach the mounting template onto an in-ceiling surface followed by drilling a hole based on the template indication. 4. Embed the in-ceiling mount bracket into the hole that was drilled based on the mounting template. 5 6 9 Spring Hook * 2 Protective Cover 5. Use a cross screw driver to turn the 2 bracket screws clockwise to extend the locking arms and tighten them securely to compress the locking arms so that the bracket can be fixed within the in-ceiling area firmly. 6. Based on your needs, use the bottom conduit hole or side conduit hole on lower case for cable entry and connect the cables. NOTE: Please properly lock the conduit hole plug on the unused hole. For example, lock the side conduit hole with the plug while using the bottom conduit hole for cable entry and vice versa. 7. Fix the lower case onto the in-ceiling bracket by fastening the 4 screws followed by aligning the identifying red dots of lower case and lens base to properly assemble them together with securing the 3 lens base screws. 8. After adjusting focus position to the satisfied field of view, mount the top cover on the lens base, both of which have a red dot respectively also for aligning identification and tighten the 3 top cover screws firmly. 9. Attach the 2 spring hooks flanked the protective cover to the in-ceiling bracket for mounting completion. NOTE: It is strongly recommended that you first ensure the mounting area is stable enough to withstand the in-ceiling bracket and locking arms clamping on the ground of safety concern. 9
WALL SURFACE MOUNT Install the indoor dome camera to a wall surface as shown in the following procedure. T2 T1 T1 T1 T1 T2 1. Based on your needs, use the bottom or side conduit hole on the lower case for cable entry and connect the required cables first. Then mount the lower case on a surface by securing screws (supplied) into the inserted plastic anchors tightly. 2. Align the lower case and the lens base, both of which have a red dot on the top side respectively for aligning identification. Use the red dots to properly align them and then securely fasten the 3 screws of the lens base to the bottom case with torx key (supplied). 3. Adjust the focusing position by rotating, panning and tilting the camera lens base. When rotating the camera lens, do not rotate it over the stop point. 4. Fit the inner liner over the camera lens base until it snaps into the place. 5. Mount the top cover on the lens base, both of which similarly have a red dot for aligning identification. Be aware that the red dot of the top cover is within the interior instead of on the top side. 6. Use the torx wrench (supplied) to tighten the 3 top cover screws to complete mounting. NOTE: Please properly lock the conduit hole plug on the unused hole. For example, lock the side conduit hole with the plug while using the bottom conduit hole for cable entry and vice versa. 10
PENDANT MOUNT The Pendant Installation involves mounting IMPPM-1l Sarix Indoor Pendant Mount for Indoor Dome camera. The camera must be first installed within the pendant mount back box with an adaptor ring before assembled with additional pendant mount brackets. Below are the recommended brackets, which are NOT provided, for additional pendant mount applications for your reference. NOTE: Mounts and conduits must be sealed to prevent condensation in the camera Pendant Wall Mount Pendant Pole Mount 1. Rotate the adaptor ring, which can connect with brackets of 1 1/2 -conform screw thread, clockwise to the pendant mount back box securely as shown below. The rubber o-ring provides seal on grooves between back box and adaptor ring. Note that it is highly suggested to apply waterproof repellent onto the upper screw thread as shown below for complete ingress protection. The diagram in the right side is the back box mounted with the adaptor ring. Apply Waterproof Repellent Adaptor Ring Rubber O-Ring NOTE: Anti-seize compound should be applied on pendant mount. Not doing so might prevent the unit from being separated in the future. Waterproof tape can also be used to help prevent water ingress damage. 11
2. After wires connection, attach the lens base to the pendant mount back box by aligning the red dots for identification of both parts and securely fasten the 3 screws of the lens base with the torx wrench (supplied). Finally, assemble the top cover with the lens base, both of which, similarly, have red dots for aligning identification, followed by fastening the 3 screws of top cover to complete the installation. 12
POSITION THE CAMERA The camera has three axes for adjusting field of view on different applications. While screening live view on your monitor, adjust the position by using the procedures below simultaneously for desired focusing position. Pan Adjustment (A) Rotate the lens base until you are satisfied with the field of view. Note that the side conduit hole of lower case is the point where the camera lens shouldn t be rotated over. Horizontal Rotation (B) Rotate 3D assembly in the lens base, but do not turn assembly more than 355 as this may have the internal cables twisted, disconnected, or broken. Tilt Adjustment (C) Lift to open the inner liner, and tilt the camera lens to your desired angle. Restore the inner liner back to its default position after adjustment. NOTE: Limitation for three axes position: Pan range: ±177, Rotate range: ±177, Tilt range: 35 ~ 90 A B C ADJUSTING THE FOCUS 1. View the camera image using the browser (refer to the user manual). 2. Use the settings in the Web interface (refer to the user manual) to adjust the zoom and focus of the lens to the desired field of view. 3. Also the focus can be adjusted by moving the zoom slider and using the Focus options in the live webpage. NOTE: Focus adjustment is done exclusively with the Web UI. 13
Installation - IJP Series 2 Micro Indoor Dome You can install the Sarix Professional Series Micro Indoor Dome using the following method. Wall/Ceiling Surface Mount Surface Mount with IMPEBAP Wall Mount with IMPPMB-1I WALL/CEILING SURFACE MOUNT Install the 2 indoor Micro dome camera to a surface (wall/ceiling) as shown in the following procedure. 1 2 3 4 5 1. Pull the top cover downward to take apart it from the camera body after pressing and holding the 2 latch buttons at 2 sides. 2. Connect the required network cable and the optional digital IO cables if necessary. Thread the cables through either bottom or side conduit hole depending on different mounting applications. The digital IO ports are described below: Alarm Out: Via OUT and COM ports, connect to external device to be triggered through alarm output signals. Alarm In: Via GND and IN ports, connect to external device that can trigger alarm input signals. Audio Out: Via GND and OUT ports, connect to device like speaker to be triggered through alarm output signals. Audio In: Via GND and IN ports, connect to external device like microphone that receives sound for camera. 3. Drill 2 hole patterns on applied surface in accordance with the indications on the mounting template (2-Ø 4.5 Holes) followed by hammering the 2 plastic anchors into the drilled holes. Also, drill another hole for cable threading as the indication for bottom conduit installation (Ignore drilling cable hole if applying side conduit method). 4. Attach the camera to the surface properly and fasten the 2 screws into the plugged plastic anchors securely to fix the camera on the location. 5. Install the top cover upward to assemble the camera completely. The camera is thus stably fixed on the surface. 14
SURFACE MOUNT WITH IMPEBAP You can mount the camera to a surface with IMPEBAP, a Sarix 4S electrical box adaptor mount for Micro Indoor Dome. Refer to the figures below for surface installation with IMPEBAP. 1 2 3 4 1. Fix the adaptor plate to the surface embedded with 4S electrical box with 2 screws. Note the hole pattern with 4 indicators that represent the exact holes for 4S installation on the adaptor for proper mounting. 2. Pass all the cable thread from camera body into the adaptor plate and surface followed by wiring them if necessary. Fasten the camera body onto the adaptor plate with 2 screws. Note the hole pattern with D indicators that represent the exact holes for Micro Indoor Dome installation on the adaptor for proper mounting. 3. Properly attach the dome cover until click to the camera body that was fixed with the adaptor plate already. 4. The Micro Indoor Dome is eventually properly mounted on the surface with IMPEBAP. 15
WALL MOUNT WITH IMPPMB-1I Wall mount with IMPPMB-1I requires both the L-shape bracket and the adaptor plate from IMPEBAP. Refer to the figures below for detailed process for Wall Mount with IMPPMB-1I. 1 2 3 4 5 1. Fasten the L-shape bracket onto the desired wall with 4 screws. 2. Further fix the adaptor plate from IMPEBAP onto the L-shape bracket with 2 screws. Note the hole pattern with L indicators that represent the exact holes for L-shape bracket assembly on the adaptor for proper installation. 3. Pass all the cable thread from camera body into the adaptor plate and L-shape bracket followed by wiring them if necessary. Fasten the camera body onto the adaptor plate with 2 screws. Note the hole pattern with D indicators that represent the exact holes for Micro Indoor Dome installation on the adaptor for proper mounting. 4. Properly attach the dome cover until click to the camera body that was fixed with the adaptor plate already. 5. The Micro Indoor Dome is eventually properly mounted on the wall with IMPPMB-1I. 16
POSITIONING & ADJUSTING THE FIELD OF VIEW The camera has three axes for adjusting field of view on different applications. While screening live view on your monitor, adjust the position using the procedures below simultaneously for desired focusing position. Pan Adjustment (A) Rotate the lens base until satisfied with the field of view. Note that the bottom conduit hole of camera body is the point where the camera lens shouldn t be rotated over. Horizontal Rotation (B) Rotate 3D assembly in the lens, but do not turn assembly more than the limit as this may have the internal cables twisted, disconnected, or broken. Tilt Adjustment (C) Adjust the camera lens tiltedly within the certain range (35-90 ) to your desired field of view. A B A. Pan = ±177 B. Rotate = ±177 C. Tilt = 35 ~ 90 C 17
Pelco Troubleshooting Contact Information If the instructions provided fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 (USA and Canada) or +1-559-292-1981 (international) for assistance. Be sure to have the serial number available when calling. Do not try to repair the unit yourself. Leave maintenance and repairs to qualified technical personnel only. Note for Dimension Drawings NOTE: VALUES IN PARENTHESES ARE INCHES; ALL OTHERS ARE CENTIMETERS. 3.75 INDOOR DOME 2 MICRO INDOOR D 18
19 Copyright 2016, Pelco, Inc. All rights reserved.