General information. Display. Supply voltage. Input current

Similar documents
General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display

CPU 1214C. Overview. Design. The compact CPU 1214C has:

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Supply voltage. Input current. Encoder supply. Memory

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

General information. Supply voltage

Product type designation. General information. Supply voltage. Input current

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Product type designation. General information. Supply voltage

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

Product type designation

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

SIPLUS CPU 313C-2DP. Function

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

General information. Supply voltage. Input current

General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current. Power loss

Product type designation. General information. Supply voltage. Input current. Power losses

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

General information. Configuration control. Display. Control elements. Supply voltage

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

Data sheet VIPA CPU 115DP (115-6BL22)

Data sheet CC 03, Commander Compact (603-1CC21)

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

TM221M16R controller M IO relay

Product type designation. General information. Supply voltage

Data sheet CPU 115 (115-6BL02)

Data sheet VIPA CPU M13C (M13-CCF0000)

Siemens AG SIMATIC S Micro Controller for Totally Integrated Automation. Catalog ST 70 N April 2009 SIMATIC. Answers for industry.

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

CPU 412H. Function. Parameterizable properties

FEATURES DESCRIPTION FEATURES

Data sheet VIPA CPU 214PG (214-2BE03)

SIMATIC S /2 Introduction

AI561 Analog Input Module

TM221CE24R controller M IO relay Ethernet

AO561 Analog Output Module

DI572 Digital Input Module

TM221CE40T controller M IO transistor PNP Ethernet

CM597 Ethernet Communication Module

Data sheet CPU 013C (013-CCF0R00)

Data sheet VIPA CPU 214NET PG (214-2BT13)

TM241C40U controller M IO transistor NPN

TM221ME32TK controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM221M16TG controller M IO transistor PNP spring

TM241C24T controller M IO transistor PNP

TM241CE24U controller M IO transistor NPN Ethernet

TM221M32TK controller M IO transistor PNP

64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

DI561 Digital Input Module

General information. Supply voltage

TM241C40R controller M IO relay

TM221CE40R controller M IO relay Ethernet

SIMATIC S /2 3/4 3/22 SIPLUS 3/26 3/33 SIPLUS

Transcription:

Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 150 KB General information Product type designation CPU 1217C DC/DC/DC Firmware version V4.1 Engineering with Programming package STEP 7 V13 SP1 or higher Display with display Supply voltage Rated value (DC) 24 V DC permissible range, lower limit (DC) permissible range, upper limit (DC) Reverse polarity protection Load voltage L+ Rated value (DC) Input current Current consumption (rated value) Current consumption, max. No 20.4 V 28.8 V 24 V 600 ma; CPU only 1 600 ma; CPU with all expansion modules Page 1/8 19.01.2016 Copyright Siemens AG

Inrush current, max. Encoder supply 24 V encoder supply 24 V Power loss Power loss, typ. Memory Type of memory Work memory integrated expandable Load memory integrated Plug-in (SIMATIC Memory Card), max. Backup present without battery CPU processing times for bit operations, typ. for word operations, typ. for floating point arithmetic, typ. CPU-blocks Number of blocks (total) OB Number, max. 12 A; at 28.8 V DC L+ minus 4 V DC min. 12 W RAM 150 kbyte No 4 Mbyte with SIMATIC memory card ; maintenance-free 0.085 µs; / Operation 1.5 µs; / Operation 2.3 µs; / Operation DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used Limited only by RAM for code Data areas and their retentivity retentive data area in total (incl. times, counters, flags), max. Flag Number, max. Local data 10 kbyte 8 kbyte; Size of bit memory address area per priority class, max. 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB Address area I/O address area Inputs Outputs Process image 1 024 byte 1 024 byte Page 2/8 19.01.2016 Copyright Siemens AG

Inputs, adjustable Outputs, adjustable Hardware configuration Number of modules per system, max. 1 kbyte 1 kbyte 3 comm. modules, 1 signal board, 8 signal modules Time of day Clock Hardware clock (real-time clock) Backup time 480 h; Typical Deviation per day, max. +/- 60 s/month at 25 C Digital inputs Number of digital inputs of which inputs usable for technological functions integrated channels (DI) m/p-reading Number of simultaneously controllable inputs all mounting positions up to 40 C, max. 14 Input delay (for rated value of input voltage) for standard inputs 14; Integrated 6; HSC (High Speed Counting) 14; Of which, 10x 24 V DC and 4x RS 422/485 differential parameterizable 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four at "0" to "1", min. 0.2 ms at "0" to "1", max. 12.8 ms for interrupt inputs parameterizable for counter/technological functions Cable length parameterizable shielded, max. unshielded, max. Digital outputs Number of digital outputs 10 of which high-speed outputs integrated channels (DO) Output delay with resistive load "0" to "1", max. 1 µs "1" to "0", max. 5 µs Analog inputs Number of analog inputs 2 500 m; 50 m for technological functions 300 m; For technological functions: No 4; 100 khz Pulse Train Output 10; of which, 6x 24 V DC and 4x 1.5 V differential Page 3/8 19.01.2016 Copyright Siemens AG

integrated channels (AI) Input ranges Voltage Input ranges (rated values), voltages 0 to +10 V Input resistance (0 to 10 V) Cable length shielded, max. 2; 0 to 10V 100k ohms 100 m; twisted and shielded Analog outputs Number of analog outputs 2 integrated channels (AO) 2; 0 to 20 ma Output ranges, current 0 to 20 ma Analog value generation Integration and conversion time/resolution per channel Resolution with overrange (bit including sign), 10 bit max. Integration time, parameterizable Conversion time (per channel) 625 µs Encoder Connectable encoders 2-wire sensor 1. Interface Interface type PROFINET Physics Ethernet Isolated automatic detection of transmission rate Autonegotiation Autocrossing Functionality PROFINET IO Controller PROFINET IO Device Open IE communication Web server PROFINET IO Controller Transmission rate, max. 100 Mbit/s Services Number of connectable IO Devices, max. 16 PROFINET IO Device Services Shared device Page 4/8 19.01.2016 Copyright Siemens AG

Number of IO Controllers with shared device, max. Protocols Supports protocol for PROFINET IO PROFIBUS AS-Interface Protocols (Ethernet) TCP/IP Further protocols MODBUS Communication functions S7 communication supported as server as client Open IE communication TCP/IP ISO-on-TCP (RFC1006) UDP Web server supported User-defined websites Number of connections overall Test commissioning functions Status/control Status/control variable Variables Forcing Forcing Diagnostic buffer present Traces Number of configurable Traces 2 ; CM 1243-5 required 16; dynamically Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 2; Up to 512 KB of data per trace are possible Integrated Functions Number of counters 6 Counting frequency (counter) max. 1 MHz Frequency meter controlled positioning Number of position-controlled positioning axes, max. 8 Page 5/8 19.01.2016 Copyright Siemens AG

Number of positioning axes via pulse-direction 4; With integrated DO interface PID controller Number of alarm inputs 4 Number of pulse outputs 4 Limit frequency (pulse) 1 MHz Potential separation Potential separation digital inputs Potential separation digital inputs No between the channels, in groups of 1 Potential separation digital outputs between the channels No between the channels, in groups of 1 EMC Interference immunity against discharge of static electricity Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Test voltage at air discharge 8 kv Test voltage at contact discharge 6 kv Interference immunity to cable-borne interference Interference immunity on supply lines acc. to IEC 61000-4-4 Interference immunity on signal cables acc. to IEC 61000-4-4 Interference immunity against voltage surge on the supply lines acc. to IEC 61000-4-5 Interference immunity against conducted variable disturbance induced by high-frequency fields Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 Emission of radio interference acc. to EN 55 011 Limit class A, for use in industrial areas ; Group 1 Limit class B, for use in residential areas ; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 Degree and class of protection Degree of protection acc. to EN 60529 IP20 Standards, approvals, certificates CE mark UL approval culus FM approval RCM (formerly C-TICK) Page 6/8 19.01.2016 Copyright Siemens AG

Marine approval Marine approval Ambient conditions Free fall Drop height, max. (in packaging) 0.3 m; five times, in dispatch package Ambient temperature during operation min. -20 C max. 60 C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 C horizontal or 50 C vertical, 14 or 10 at 55 C horizontal or 45 C vertical horizontal installation, min. -20 C horizontal installation, max. 60 C vertical installation, min. -20 C vertical installation, max. 50 C Ambient temperature during storage/transportation min. -40 C max. 70 C Air pressure acc. to IEC 60068-2-13 Operation, min. 795 hpa Operation, max. 1 080 hpa Storage/transport, min. 660 hpa Storage/transport, max. 1 080 hpa permissible operating height -1000 to 2000 m Relative humidity permissible range (without condensation) at 25 95 % C Vibrations Vibrations 2G wall mounting, 1G DIN rail Operation, tested according to IEC 60068-2-6 Shock test tested according to IEC 60068-2-27 ; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms Extended ambient conditions Pollutant concentrations SO2 at RH < 60% without condensation S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free Configuration Programming Programming language LAD FBD SCL Cycle time monitoring Page 7/8 19.01.2016 Copyright Siemens AG

adjustable Dimensions Width Height Depth Weights Weight, approx. 150 mm 100 mm 75 mm 500 g last modified: 13.01.2016 Page 8/8 19.01.2016 Copyright Siemens AG