Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Similar documents
Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor with analog output BI15-M30-LI-EXI

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

Magnetic Field Sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive sensor BI5-EM18-Y1X-H1141

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Flow monitoring For the connection of intrinsically safe flow sensors IO-Link device with relay outputs FMX-IM-3UR38X

Temperature Converters

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 12/2007

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Operating Instructions

Safety Instructions Cerabar S PMP71, PMP75

PHOENIX CONTACT - 01/2008

M E M O R A N D U M I.S.

Product manual plug, sockets and coupler 16 A.- Z0251

Instruction Manual. T3110 T3110L T3110Ex

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

PHOENIX CONTACT - 05/2007

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Safety instructions VEGATOR 121, 122

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

Installation & Operation Manual

Operating instructions. Switching amplifier DN0210 DN / / 2015

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

PHOENIX CONTACT - 02/2008

Operating Instructions

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

MINI MCR-SL-MUX-V8-FLK 16

FLEX Ex Spring Clamp Terminal Base

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Technical Data. Dimensions

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Operating Instructions for Level Switch for Liquids. Model: RFS

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

Operating instructions Evaluation system for flow sensors VS / / 2013

SolConeX Wall-Mounted Socket, 16 A

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

SolConeX extra-low voltage flange socket

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Operating instructions. Speed monitor D / / 2014

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Safety Instructions Micropilot FMR56/57

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Safety Instructions Micropilot FMR50/51/52/53/54/56/57

Rosemount 248 Wireless Temperature Transmitter

Emergency power supply NV2.1-12iaE

Refer to attachment for more details. Andreas Meyer

Zener Barriers Bulletin 937Z

Operating Manual Touchpad CHALLENGER TPi

MINI MCR-SL-CVS NC

5 Fieldbus Technology

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

SUBCON-PLUS-PROFIB...

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Installation & Operation Manual

Safety instructions Overvoltage protection B81-35

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MANUAL Surge Protectors

Manual Mouse Module CHALLENGER Mi-PS2 / Mi-PS2-B

SMARTLINE RM76 Supplementary instructions

Vibration Sensor Type 640

Safety Instructions Cerabar M PMC51, PMP51, PMP55

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Operation Manual Series W-500

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

MINI MCR-SL-PT100-UI-200

Intrinsically safe batch controller Batching Master 110i

DR7100 SERIES Supplementary instructions

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Transcription:

MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment via potentiometer 6 LEDs for display of the flow state intrinsically safe control circuit, [EExia] IIC switch-off delay adjustable in a range of 0 25 s wire-break monitoring 198 242 VAC Type code MS96-11EX0-R/230VAC Ident no. 5231400 Ambient temperature -20 60 C Changeover contact, relay output Wiring diagram Operating voltage 198 242 VAC No-load current I 0 ð 28 ma Output function Relay output, changover contact Device designation É II(1) G D [EEx ia] IIC Protection type II(1) G D [EEx ia] II C Ex approval acc. to conformity certificate TÜV 96 ATEX 1098 Protection class IP20 Protection class (terminals/housing) IP20 / IP40 Design Dimensions Housing material Connection Indication: Drop below setpoint Indication: Setpoint reached Indication: Setpoint exceeded 110 x 50 x 75 mm polycarbonate/abs LED red LED yellow 4 x LEDs green Functional principle Signal processors not only supply insertion and inline sensors with voltage, they also process and display the measured signals. Devices with MK96, MS96 and MC96 housing styles are available. The individual housing styles are designed for different operating voltages and feature various output and supplementary functions. For intrinsically safe flow sensors it is required to use signal processors with intrinsically safe control circuits of the series MS96 Ex and MC96 Ex.

MS96-11EX0-R/230VAC Operating manual Intended use This device fulfils the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN50014 and EN50020. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) Ex II 1 G and Ex ia IIC T6 acc. to EN60079-11 and -26 and Ex II 1 D Ex iad 20 T95 C acc. to EN60079-11 and EN61241-0 and -11 Local admissible ambient temperature -20 +60 C Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is accessory equipment which features intrinsically safe circuits as well as non-intrinsically safe circuits. It may only be installed outside the explosion hazardous area in dry, clean and well monitored areas. If a declaration of conformity or declaration of the manufacturer as a category 3 device exists, the device may be installed in zone 2. Special conditions for safe operation must be observed. Intrinsically-safe electrical equipment can be connected to the intrinsically-safe connections. All equipment must comply with the demands for operation in the existing zone of the explosion hazardous area. If the intrinsically safe circuits lead to the dust explosion hazardous zones 20 or 21, it is important to ensure that the devices connected to this circuit fulfil the demands for category 1D or 2D and are certified accordingly. If the equipment is interconnected, it is necessary to perform the "Proof of intrinsic safety" (EN 60079-14). Equipment which has been used once to connect intrinsically safe circuits to non-intrinsically safe circuits is no longer suitable for subsequent use with intrinsically safe circuits. Relevant regulations exist for the establishment of intrinsically-safe circuits, mounting of external connection parts as well as the characteristics and laying of cables. Cables and terminals with intrinsically-safe circuits must be marked. They should be separated from non-intrinsically safe circuits or must feature appropriate insulation (EN 60079-14). Observe the prescribed clearances to earthed components and connections of other devices to the intrinsically-safe connections of this device. Unless expressed specifically in the device-specific operating instructions, the approval becomes void if the device is opened, repaired or actions are performed on the device by someone other than approved experts or the manufacturer. Visible changes to the device housing, such as brown-black discolourations caused by heat, as well as holes or bulges also indicate a serious danger. Switch off the device immediately. With the associated electrical equipment the interconnected intrinsically-safe equipment must also be checked. Inspection of a device with regard to the explosion protection can only be performed by an expert or the manufacturer. The operation of the devices is only permitted in conjunction with the permitted data printed on the side of the housing. Before any commissioning or modification of the device interconnections, ensure that the respective regulations, directives and conditions have been complied with and also ensure that use is only for the intended purpose and the safety requirements have been fulfilled. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Special conditions for safe operation The device must be protected against any kind of mechanical damage. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.

MS96-11EX0-R/115VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment via potentiometer 6 LEDs for display of the flow state intrinsically safe control circuit, [EExia] IIC switch-off delay adjustable in a range of 0 25 s wire-break monitoring 99 121 VAC Type code MS96-11EX0-R/115VAC Ident no. 5231402 Ambient temperature -20 60 C Changeover contact, relay output Wiring diagram Operating voltage 99 121 VAC No-load current I 0 ð 75 ma Output function Relay output, changover contact Device designation É II(1) G D [EEx ia] IIC Protection type II(1) G D [EEx ia] II C Ex approval acc. to conformity certificate TÜV 96 ATEX 1098 Protection class IP20 Protection class (terminals/housing) IP20 / IP40 Design Dimensions Housing material Connection Indication: Drop below setpoint Indication: Setpoint reached Indication: Setpoint exceeded 110 x 50 x 75 mm polycarbonate/abs LED red LED yellow 4 x LEDs green Functional principle Signal processors not only supply insertion and inline sensors with voltage, they also process and display the measured signals. Devices with MK96, MS96 and MC96 housing styles are available. The individual housing styles are designed for different operating voltages and feature various output and supplementary functions. For intrinsically safe flow sensors it is required to use signal processors with intrinsically safe control circuits of the series MS96 Ex and MC96 Ex.

MS96-11EX0-R/115VAC Operating manual Intended use This device fulfils the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN50014 and EN50020. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) Ex II 1 G and Ex ia IIC T6 acc. to EN60079-11 and -26 and Ex II 1 D Ex iad 20 T95 C acc. to EN60079-11 and EN61241-0 and -11 Local admissible ambient temperature -20 +60 C Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is accessory equipment which features intrinsically safe circuits as well as non-intrinsically safe circuits. It may only be installed outside the explosion hazardous area in dry, clean and well monitored areas. If a declaration of conformity or declaration of the manufacturer as a category 3 device exists, the device may be installed in zone 2. Special conditions for safe operation must be observed. Intrinsically-safe electrical equipment can be connected to the intrinsically-safe connections. All equipment must comply with the demands for operation in the existing zone of the explosion hazardous area. If the intrinsically safe circuits lead to the dust explosion hazardous zones 20 or 21, it is important to ensure that the devices connected to this circuit fulfil the demands for category 1D or 2D and are certified accordingly. If the equipment is interconnected, it is necessary to perform the "Proof of intrinsic safety" (EN 60079-14). Equipment which has been used once to connect intrinsically safe circuits to non-intrinsically safe circuits is no longer suitable for subsequent use with intrinsically safe circuits. Relevant regulations exist for the establishment of intrinsically-safe circuits, mounting of external connection parts as well as the characteristics and laying of cables. Cables and terminals with intrinsically-safe circuits must be marked. They should be separated from non-intrinsically safe circuits or must feature appropriate insulation (EN 60079-14). Observe the prescribed clearances to earthed components and connections of other devices to the intrinsically-safe connections of this device. Unless expressed specifically in the device-specific operating instructions, the approval becomes void if the device is opened, repaired or actions are performed on the device by someone other than approved experts or the manufacturer. Visible changes to the device housing, such as brown-black discolourations caused by heat, as well as holes or bulges also indicate a serious danger. Switch off the device immediately. With the associated electrical equipment the interconnected intrinsically-safe equipment must also be checked. Inspection of a device with regard to the explosion protection can only be performed by an expert or the manufacturer. The operation of the devices is only permitted in conjunction with the permitted data printed on the side of the housing. Before any commissioning or modification of the device interconnections, ensure that the respective regulations, directives and conditions have been complied with and also ensure that use is only for the intended purpose and the safety requirements have been fulfilled. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Special conditions for safe operation The device must be protected against any kind of mechanical damage. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.

MS96-11EX0-R/24VDC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment via potentiometer 6 LEDs for display of the flow state intrinsically safe control circuit, [EExia] IIC switch-off delay adjustable in a range of 0 25 s wire-break monitoring 21 28 VDC Type code MS96-11EX0-R/24VDC Ident no. 5231407 Ambient temperature -20 60 C Changeover contact, relay output Wiring diagram Operating voltage 21 28VDC No-load current I 0 ð 125 ma Output function Relay output, changover contact Device designation É II(1) G D [EEx ia] IIC Protection type II(1) G D [EEx ia] II C Ex approval acc. to conformity certificate TÜV 96 ATEX 1098 Protection class IP20 Protection class (terminals/housing) IP20 / IP40 Design Dimensions Housing material Connection Indication: Drop below setpoint Indication: Setpoint reached Indication: Setpoint exceeded 110 x 50 x 75 mm polycarbonate/abs LED red LED yellow 4 x LEDs green Functional principle Signal processors not only supply insertion and inline sensors with voltage, they also process and display the measured signals. Devices with MK96, MS96 and MC96 housing styles are available. The individual housing styles are designed for different operating voltages and feature various output and supplementary functions. For intrinsically safe flow sensors it is required to use signal processors with intrinsically safe control circuits of the series MS96 Ex and MC96 Ex.

MS96-11EX0-R/24VDC Operating manual Intended use This device fulfils the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN50014 and EN50020. In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives. For use in explosion hazardous areas conform to classification II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for dust atmospheres). Marking (see device or technical data sheet) Ex II 1 G and Ex ia IIC T6 acc. to EN60079-11 and -26 and Ex II 1 D Ex iad 20 T95 C acc. to EN60079-11 and EN61241-0 and -11 Local admissible ambient temperature -20 +60 C Installation / Commissioning These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas. Please verify that the classification and the marking on the device comply with the actual application conditions. This device is accessory equipment which features intrinsically safe circuits as well as non-intrinsically safe circuits. It may only be installed outside the explosion hazardous area in dry, clean and well monitored areas. If a declaration of conformity or declaration of the manufacturer as a category 3 device exists, the device may be installed in zone 2. Special conditions for safe operation must be observed. Intrinsically-safe electrical equipment can be connected to the intrinsically-safe connections. All equipment must comply with the demands for operation in the existing zone of the explosion hazardous area. If the intrinsically safe circuits lead to the dust explosion hazardous zones 20 or 21, it is important to ensure that the devices connected to this circuit fulfil the demands for category 1D or 2D and are certified accordingly. If the equipment is interconnected, it is necessary to perform the "Proof of intrinsic safety" (EN 60079-14). Equipment which has been used once to connect intrinsically safe circuits to non-intrinsically safe circuits is no longer suitable for subsequent use with intrinsically safe circuits. Relevant regulations exist for the establishment of intrinsically-safe circuits, mounting of external connection parts as well as the characteristics and laying of cables. Cables and terminals with intrinsically-safe circuits must be marked. They should be separated from non-intrinsically safe circuits or must feature appropriate insulation (EN 60079-14). Observe the prescribed clearances to earthed components and connections of other devices to the intrinsically-safe connections of this device. Unless expressed specifically in the device-specific operating instructions, the approval becomes void if the device is opened, repaired or actions are performed on the device by someone other than approved experts or the manufacturer. Visible changes to the device housing, such as brown-black discolourations caused by heat, as well as holes or bulges also indicate a serious danger. Switch off the device immediately. With the associated electrical equipment the interconnected intrinsically-safe equipment must also be checked. Inspection of a device with regard to the explosion protection can only be performed by an expert or the manufacturer. The operation of the devices is only permitted in conjunction with the permitted data printed on the side of the housing. Before any commissioning or modification of the device interconnections, ensure that the respective regulations, directives and conditions have been complied with and also ensure that use is only for the intended purpose and the safety requirements have been fulfilled. Installation and mounting instructions Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and avoid build-up of dust deposits on the device. If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic fields. The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet. In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before inserting the cable or opening the cable socket. Special conditions for safe operation The device must be protected against any kind of mechanical damage. service / maintenance Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important data from the approval are listed.