ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Similar documents
ZBRN1. Main. Device short name

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RM35LM33MW liquid level control relay RM35-L V AC/DC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

RE9RA21MW7 off-delay timing relay s V AC -

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

TM258LD42DT4L compact base M I/O - 24 V DC

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

TM3DI16G module TM3-16 inputs spring

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RM4TR31 three-phase network control relay RM4-T - range V

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

TM258LF42DT compact base M I/O - 24 V DC - CANopen

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RM4TA32 three-phase network control relay RM4-T - range V

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RMCN22BD Analog Converter ma - for Zelio Analog

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

TM3TI4 module TM3-4 inputs temperature

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TM221CE40T controller M IO transistor PNP Ethernet

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

TM221CE24R controller M IO relay Ethernet

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

TM241CE24T controller M IO transistor PNP Ethernet

K1F006ALH cam switch - 6-pole A - screw mounting

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

TM3SAF. Main. Device short name

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

RM4LA32M liquid level control relay RM4-L V AC

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

TM241CE40R controller M IO relay Ethernet

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

RM4JA31M current measurement relay RM4-J - range ma V AC

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

RM35TF V AC

TM221ME32TK controller M IO transistor PNP Ethernet

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

ABS2EC01EB input interface module mm - solid state - 24 V DC

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

TM221M16R controller M IO relay

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

LMC058LF42 compact base - 42 I/O - 24 V DC supply

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

XPSMC32Z safety controller XPS-MC - 24 V DC - 32 input - 46 LEDs signalling

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

TM3SAK. Main. Device short name

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

SR2E121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - no display

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Transcription:

Characteristics access point- 2 RJ45-24..240V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio Main Range of product Product or component type Device short name Product specific application Function of module Communication port protocol Harmony Wireless access point Interface to PLC Monostable Zigbee green power at 2.4 GHz conforming to IEEE 802.15.4 Complementary [Us] rated supply voltage 24...240 V AC/DC at 50/60 Hz (- 10...10 %) Immunity to microbreaks Maximum sensing distance Response time 10 ms Channels utilisation <= 60 Power consumption in W Breaking capacity Breaking capacity 60 m (transmitter in a plastic box type XAL D and use relay-antenna) 40 m (transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna) 25 m (transmitter in a plastic box type XAL D and receiver in a metal enclosure) 100 m (in free field) < 30 ms after transmitter clicks <= 4 W AC/DC 15 W 750 VA Control circuit frequency 50...60 Hz +/- 10 % Short circuit protection Operating position Electrical connection 16 A by GB2 circuit breaker Any position without derating 2 conductors cable 0.2...2.5 mm² AWG24...AWG18 flexible with cable end conforming 1 conductor cable 0.2...0.75 mm² AWG24...AWG14 flexible with cable end conforming 2 conductors cable 0.2...1.5 mm² AWG24...AWG16 solid without cable end conforming 1 conductor cable 0.2...4 mm² AWG24...AWG12 solid without cable end conforming Tightening torque 0.35...0.4 N.m conforming to EN/IEC 60947-1 Housing material Status LED Mounting support Rated short-duration power frequency withstand voltage [Uimp] rated impulse withstand voltage Self-extinguishing plastic 1 LED (green and yellow) : reception signal 5 LEDs (red) : function mode 1 LED (yellow) : communication network 1 LED (green) : power ON Mounting plate 35 mm symmetrical DIN rail conforming to EN/IEC 60715 1.5 kv at 50 Hz conforming to EN/IEC 60947-5-1 Surge withstand 2 kv (common mode) conforming to IEC 61000-4-5 1 kv (differential mode) conforming to IEC 61000-4-5 Width Height Depth Product weight 4 kv 122 mm 90 mm 60 mm 0.26 kg The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Aug 21, 2015 1

Marking Integrated connection type Data storage equipment Topology Port Ethernet Cable length Web services CE Ethernet Modbus TCP/IP (RJ45 in Modbus TCP network) 10/100 Mbit/s 2 twisted pairs SD card Devices linked by daisy-chaining or tap junctions 10BASE-T/100BASE-T 0...1000 m Predefined web pages configuration Environment Radio agreement Product certifications SRRC RSS category 1 conforming to EN 300-440-1 ICASA FCC category 2 conforming to EN 300-440-1 ANATEL type III conforming to EN 301-489-3 CCC CE CSA C-Tick GOST UL EMC directive 2004/108/EC R&TTE directive 1999/5/EC LVD directive 2006/95/EC Standards EN 300328 EN/IEC 60950-1 EN/IEC 61131-2 UL 508 EN 300-440-2 EN 62311 CSA C22.2 No 14 Ambient air temperature for storage -40...70 C Relative humidity 90 % (-25...55 C) without condensation conforming to EN 300-440-1 Operating altitude Storage altitude 0...2000 m 0...3000 m Vibration resistance 2 gn (f= 8...150 Hz) on DIN rail conforming to IEC 60068-2-6 1 gn (f= 5...150 Hz) on panel mounting conforming to IEC 60068-2-6 +/- 3.5 mm (f= 5...14 Hz) conforming to IEC 60068-2-6 Shock resistance 10 gn (6000 shocks during 16 ms) conforming to IEC 60068-2-27 IP degree of protection IP20 (terminals) IP20 (casing) conforming to IEC 60529 Pollution degree 2 conforming to IEC 60664-1 Electromagnetic compatibility Immunity to microbreaks and voltage drops :10 ms conforming to IEC 61000-4-11 1.2/50 µs shock waves immunity test :2 kv (common mode) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test :1 kv (differential mode) conforming to IEC 61000-4-5 Dielectric strength 2150 V DC between input and ground 1500 V AC between input and ground 4250 V DC between input and output 3000 V AC between input and output 2

Dimensions Drawings Access Point Dimensions 3

Mounting and Clearance Access Point on a Mounting Panel The Access Point is installed according to its vertical axis Access Point on DIN rail Mounting Clearances Maximum Distance between Transmitter and the Access Point in Free Field Unobstructed (2) Access Point Maximum Distance between Transmitter and the Access Point in a Metal enclosure without a Relay Antenna (3) Access Point in a Metal enclosure 4

Maximum Distance between Transmitter and the Access Point in a Metal Enclosure with a Relay Antenna (3) Access Point in a Metal enclosure (4) Relay Antenna Maximum Distance between Transmitter and the Access Point in a Metal Enclosure with a Passive Antenna (2) External Antenna (3) Access Point in a Metal enclosure The range is reduced if the transmitter is placed in a metal enclosure (reduction factor : approx 10%) Glass window 10...20 % Plaster wall 30...45 % Brick wall 60 % Concrete wall 70...80 % Metal structure 50...100 % Access Point Clearances (1) Power Supply (2) Programmable Logic Controller 5

Connections and Schema Access Point Wiring Diagram (1) wire sizes for Power Supply terminals (L/+,N/-) 6