SC846 X9 Universal Air Shroud User s Guide

Similar documents
SC835 Air Shroud User s Guide

SC823 Air Shroud User s Guide

BPN-SAS3-743A Backplane USER'S GUIDE

BPN-NVMe3-216N-S4 Backplane USER'S GUIDE 1.0

BPN-NVMe3-116UN Backplane USER'S GUIDE

BPN-SAS-F424-A6 Backplane USER'S GUIDE

BPN-SAS3-F418-B6N4 Backplane USER'S GUIDE

SUPER. BPN-NVMe3-227SSB Midplane USER'S GUIDE. Revision 1.0

BPN-NVMe3-136NB-L Backplane BPN-NVMe3-136NB-R Backplane BPN-NVMe3-136PL Backplane BPN-NVMe3-136PL-J Backplane USER'S GUIDE

BPN-SAS-825MTQ Backplane

SAS-833TQ BACKPLANE USER'S GUIDE

SAS-809T/TQ BACKPLANE

SUPER QUICK REFERENCE GUIDE SC847 CHASSIS SERIES CONNECTIVITY CONFIGURATIONS 1.0

BPN-SAS3-825TQ BAckPlANe USeR'S GUIDe 1.0a

1.0 S UPER SAS815TQ #0 ACT IN REV 1.00 #2 JP29:9071 RST JP18 JP18:BUZZER RESET JP46 JTAG UPGRADE JP29 SIDEBAND +5V +5V +12V +5V +12V JP42 JP33 JP34

AOC-SLG3-2M2. User's Guide. Revision 1.0a

SAS-113TQ BACKPLANE USER'S GUIDE

M.2 Carrier Card. Installation Guide. Revision 1.0

SAS-510T BACKPLANE USER'S GUIDE

SUPER. SAS3-216A Backplane USER'S GUIDE 1.0 BPN-SAS3-216A + + SAS IN#1 SAS IN#2 SAS IN#6 JP35 JP JSM6 JP35 ATMEL RST 1-2:RST 2-3:NO RST

AOM-S3108M-H8. User's Guide. Revision 1.0

AOC-SLG3-2E4T. User's Guide. Revision 1.0

CSE-M14T Mobile Rack USER'S GUIDE

BPN-SAS3-216A-N4 Backplane

Installing Cache Protection for RAID 3108 Card on BigTwin Server. User s Guide. Revision 1.0

AOC-SLG3-4E4R. User's Guide. Revision 1.0a

AOC-SLG3-4E4T. User's Guide. Revision 1.0a

SIDEBAND#2 3 JP43 JP37 JP45 JP38 JP41 J10 I C#2 JP36 JP50:I2CRST#1 JP38:I2CRST#2 OFF:SGPIO ON:I2C JP50 JP29 2 I C#1 JP40 JP44 JP51 JP29:9072 RESET

SAS-216EL1/EL2 BACKPLANE USER'S GUIDE

Large Deployment of. SuperDoctor 5 on Windows. User s Guide

AOC-TBT-DSL5320 USER GUIDE. Revision 1.0a

AOC-SLG3-2E4R. User's Guide. Revision 1.0a

TPM AOM-TPM-9670V AOM-TPM-9670H AOM-TPM-9670V(H)-S

SBA-7121M-T1 Blade Module RAID Setup Procedure

BPN-SAS-939H Backplane USER'S GUIDE

1.0a BPN-SAS3-116A-N2 REV 1.10 BAR CODE + + PRESS FIT MH2 MH3 T-SGPIO1 GND MH4 MH V JPW1 GND CG2 4 JPW2 J23 C79 CG2 CG3 JSM2 PRESS FIT C88 C33

SAS-213LTQ BACKPLANE USER'S GUIDE

Management Plugin for SCOM/SCCM

SAS-218A BACKPLANE USER'S GUIDE

BPN-SAS3-116A-N2 Backplane

JP45 JP45:OH#2 TEMP. OPEN:45 C 1-2:50 C 2-3:55 C C203 C197 U63 JP35:9072#1 RESET 1-2: RESET 2-3: NO RESET C173 C243 R423 R270 JP97 JP98 JP99 JP100

SUPER USER S MANUAL SC731 CHASSIS SERIES. 1.0b

742S 742i SC742 CHASSIS USER'S GUIDE

U42 1 JP51 J16 JP13 4 RP7 4 1 SAS116TQ REV 1.00 #5 # RST J12 JP29 JP34 C RST BAR CODE J10 C285 C98 SAS-116TQ BACKPLANE USER'S GUIDE

BPN-SAS3-809H BAckPlANe USeR'S GUIDe 1.0

SAS826A + C44 JP25 REV 1.00 R63 C1 C A U41 JP25:OH#1 TEMP C SAS IN #2 OPEN:45 C 1-2:50 JSM2 RT2 R200 R201 C D36 JP18 C138 BUZZER RESET JP45:OH#2 TEMP

AOC-S3008L-L8e. User's Guide. Revision 1.0

SUPER USER S MANUAL. SC503 Chassis Series SC B. 1.0b

DIVAR IP 2000 DIP N, DIP HD, DIP HD. en Quick Installation Guide

JP39: OPEN:DEFAULT CLOSE:PS_ON JP36: OPEN:DEFAULT CLOSE:ANY POWER BUTTON JP38: OPEN:DEFAULT A C JPW1 MB-D JF4 R V 5V-SB C246 GND C86 C75 U30

FAN2 JP56 32 A C BAR CODE 53 DEBUG JP55 FAN3 U81 F36 A 49 1 J25 X Y2 JF4 JPW1 TO PS JF3 JPI2C1 Q875 C201 Q873 Q876 F55 C197

SAS-933EL SERIES BACKPLANE USER'S GUIDE

AOC-STG-I2 USER'S GUIDE

BPN-SAS3-827HD-N4 Backplane

SUPER USER S MANUAL. SC510T Chassis Series SC510T-200B 1.0

TPM AOM-TPM-9655V AOM-TPM-9655V-S AOM-TPM-9655V-C AOM-TPM-9655H AOM-TPM-9655H-S AOM-TPM-9655H-C

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

AOC-USASLP-S8i AOC-USASLP-S8iR USER'S GUIDE

SCA 813S Backplane USER'S GUIDE

Memory Configuration Guide. X11 UP/DP/MP Motherboards. for. Revision 1.0a

SAS 846 TQ BACKPLANE

2U Server. User Manual

AOC-CGP-i2. User's Guide. Revision 1.0

ATX12V 2.2 Power Supply for HP & Compaq Systems

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

PRESS FIT A PRESS FIT A PRESS FIT A B C D B C D B C D F G H F G H F G H J24 J23 J22 J21 J20 J19 J18 J17 REV:1.02 BPN-EXP-847DF2EL1 + + EC1

LVN5200A-R2, rev. 1, Hardware Installation Guide

Reliable ATX 12V 2.01 Power Supply

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SC832/SC833 CHASSIS USER'S GUIDE

AOC-CIBF-M1. User's Guide. Revision 1.0

ATX2POWER430 ATX2POWER530. Instruction Manual. ATX Power Supply. 430W/530W ATX12V 2.3 EPS Computer Power Supply - 80 Plus Certified

Professional ATX Power Supply

AOC-STG-b4S. User's Guide. Revision 1.0

High-Performance Dual Fan 350-Watt ATX Power Supply. ATXPOW350DF Instruction Manual

AOC-UIBF-m1. User's Guide. Revision 1.0a

SUPER USER S MANUAL. SC808 Chassis Series SC808T-1200W. 1.0b

L2 / L3 Switches. Access Control Lists (ACL) Configuration Guide

Reliable High-Performance 350 Watt ATX 12V Power Supply. ATXPOW350PRO Instruction Manual

Trayless SATA Drive Bay 5.25" Trayless SATA Hot Swap Drive Bay

SUPER USER S MANUAL. SC219 Chassis Series SC219A-R920WB 1.0 SUPERMICR

SATA Hard Drive Enclosure

DIVAR IP 3000 DIP N, DIP HD, DIP HD. en Quick Installation Guide

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

AOC-S3216L-L16iT USER S GUIDE. Revision 1.0

IceBreaker 2816 PENGUIN COMPUTING. Technical Guide Rev PENGUIN ( )

2U ATX12V 2.01 Power Supply

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Broadband Automatic Disconnect Switch. User Manual

SUPER USER S MANUAL SC812L CHASSIS SERIES SC812L-420C 1.0 SC812L-280U SC812L

Trusted Platform Module (TPM) TCG 1.2 / 2.0

LED FOLDING WORKLIGHT TM

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

User Manual PCL channel Isolated Digital Output Card

StoneGate SG-200 Appliance Installation Guide

AC4G-D User s Manual

3190 Series Touch Screen POS Workstation

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Bluetooth Shielding Instructions

Transcription:

SC846 X9 Universal Air Shroud User s Guide Revison 1.0

SC846 Air Shroud User s Guide The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com. Super Micro Computer, Inc. ( Supermicro ) reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent. IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product. FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense. California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate for further details. Manual Revison 1.0 WARNING: HANDLING OF LEAD SOLDER MATERIALS USED IN THIS PRODUCT MAY EXPOSE YOU TO LEAD, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE BIRTH DEFECTS AND OTHER REPRODUCTIVE HARM. Release Date: October 3, 2011 Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders. Copyright 2011 by Super Micro Computer, Inc. All rights reserved. Printed in the United States of America ii

About this Manual Preface This manual is written for professional system integrators, Information Technology professionals, service personnel and technicians. It provides information for the installation and use of Supermicro's SC846 X9 universal air shroud. Installation and maintenance should be performed by experienced professionals only. Manual Organization Chapter 1: Introduction The first chapter provides a checklist of the main components included with the SC846 X9 universal air shroud and describes its main features. Chapter 2: System Safety You should familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SC846 X9 universal air shroud. Chapter 3: Configuration and Installation Refer here for details on installing and configuring the SC846 X9 universal air shroud on a computer system mainboard. iii

SC846 Air Shroud User s Guide Notes iv

: Table of Contents Chapter 1 Introduction... 1-1 1-1 Overview... 1-1 1-2 Product Checklist of Typical Components... 1-1 1-3 Features...1-2 1-4 Returning Merchandise for Service... 1-2 1-5 Contacting Supermicro... 1-3 Chapter 2 System Safety...2-1 2-1 Electrical Safety Precautions... 2-1 2-2 General Safety Precautions... 2-2 2-3 Electrostatic Discharge Precautions... 2-2 2-4 Operating Precautions... 2-2 Chapter 3 Configuration and Installation... 3-1 3-1 Overview... 3-1 3-2 SC846 X9 Universal Air Shroud Components... 3-1 Component Part B... 3-2 Component Part C... 3-3 Component Part D... 3-4 Component Part E... 3-5 3-3 Removing Breakable Tabs for Cabling... 3-6 3-4 Configuring the SC846 X9 Universal Air Shroud... 3-7 3-5 Installing the SC846 X9 Universal Air Shroud... 3-9 v

SC846 Air Shroud User s Guide vi

1-1 Overview Chapter 1 Introduction The SC846 X9 universal air shroud is a configurable air shroud for system mainboards to enable maximum efficient air flow through the system. It can be configured to fit different sized system mainboards of the same general shape and size. The SC846 X9 universal air shroud is optimized for use with Supermicro SC846 series chassis designs and for Supermicro X8DTx/X9DRx/H8DGx series mainboards. See Chapter 3 for configuration details. 1-2 Product Checklist of Typical Components The SC846 X9 universal air shroud comes packaged with components and parts as shown in Table 1-1: Table 1-1. SC846 X9 Universal Air Shroud Parts and Components Part Number Description Quantity MCP-310-49003-0N SC846 Intel DP X9 universal PC air shroud 13.68 x13/12 x13 motherboard MCP-310-49005-1N SC846 X9 universal air shroud component, main body (Part A) 1 MCP-310-39003-1N SC836 X9 universal air shroud component, moving part (Part B) 1 MCP-310-28005-1N X8 air shroud universal component, partition (Part C) 1 MCP-310-28006-1N X8 universal air shroud component, tear-drop 55mm (part D) 1 MCP-310-39004-1N SC836 X9 universal air shroud component, moving part (Part E) 1 NOTE: The default configuration is for Component Parts A, B, C, D and E to all be connected. NOTE: Each individual part for the SC846 X9 universal air shroud is labeled with its component part letter for easy identification. 1-1

SC846 Air Shroud User s Guide 1-3 Features The SC846 X9 universal air shroud includes the following features: Main air shroud component Four detachable components for creating multiple configurations Breakable tabs for power cable management Clear plastic material construction for ease of viewing 1-4 Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. You can obtain service by calling your vendor for a Returned Merchandise Authorization (RMA) number. When returning to the manufacturer, the RMA number should be prominently displayed on the outside of the shipping carton, and mailed prepaid or hand-carried. Shipping and handling charges will be applied for all orders that must be mailed when service is complete. For faster service, RMA authorizations may be requested online at: http://www. supermicro.com/support/rma/ Whenever possible, repack the chassis in the original Supermicro carton, using the original packaging material. If these are no longer available, be sure to pack the chassis securely, using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping. This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failure due to the alteration, misuse, abuse or improper maintenance of products. During the warranty period, contact your distributor first for any product problems. 1-2

Chapter 1: Introduction 1-5 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: Web Site: Europe Address: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) www.supermicro.com Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML s-hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 sales@supermicro.nl (General Information) Email: support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support) Asia-Pacific Address: Super Micro Computer, Inc. 4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: +886-(2) 8226-5990 1-3

SC846 Air Shroud User s Guide Notes 1-4

Chapter 2 System Safety Please read and follow all safety precautions below before using your Supermicro product. 2-1 Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the server from damage: Be aware of how to power on/off the enclosure power supplies and the individual blades as well as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system. Do not work alone when working with high voltage components. Power should always be disconnected from the blade module when removing or installing such system components as the mainboard, memory modules and processors. When working around exposed electrical circuits, another person who is familiar with the power-off controls should be nearby to switch off the power if necessary. Use only one hand when working with powered-on electrical equipment. This is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with. Do not use mats designed to decrease electrostatic discharge as protection from electrical shock. Instead, use rubber mats that have been specifically designed as electrical insulators. The power supply power cords must include a grounding plug and must be plugged into grounded electrical outlets. Power input requires 110-240 VAC, depending upon your power supply module. Mainboard Battery: This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032 Lithium 3V battery). Dispose of used batteries according to the manufacturer's instructions. WARNING: There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarities. Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Temperature Coefficient) fuses on the mainboard must be replaced by trained service technicians only. The new fuse must be the same or equivalent as the one replaced. Contact technical support for details and support. 2-1

SC846 Air Shroud User s Guide 2-2 General Safety Precautions Follow these rules to ensure general safety: Keep the area around the server clean and free of clutter. Place the blade module cover and any system components that have been removed away from the system or on a table so that they won't accidentally be stepped on. While working on the system, do not wear loose clothing such as neckties and unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan. Remove any jewelry or metal objects from your body, which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present. After accessing the inside of the system, replace the blade module's cover before installing it back into the blade enclosure. 2-3 Electrostatic Discharge Precautions Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic components and printed circuit boards. The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD: Use a grounded wrist strap designed to prevent static discharge. Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use. Touch a grounded metal object before removing the board from the antistatic bag. Do not let components or PCBs come into contact with your clothing, which may retain a charge even if you are wearing a wrist strap. Handle a board by its edges only; do not touch its components, peripheral chips, memory modules or contacts. When handling chips or modules, avoid touching their pins. Put the mainboard and peripherals back into their antistatic bags when not in use. For grounding purposes, make sure the blade enclosure provides excellent conductivity between the power supplies, the blade modules and the mainboard. 2-4 Operating Precautions Care must be taken to assure that the cover of the blade unit is in place when the blade is operating to assure proper cooling. Out of warranty damage to the blade can occur if this practice is not strictly followed. Any drive carrier without a hard drive installed must remain fully installed in the drive bay when the blade module is operating to ensure proper airflow. 2-2

Chapter 3 Configuration and Installation 3-1 Overview This chapter covers the configuration and installation of the SC846 X9 universal air shroud into a server or into a chassis. The main section (Component Part A) is connected to other sections (Component Parts B, C, D and E) to make up many possible configurations based upon the sliding positions of the components and locking tabs (even more if parts are detached). 3-2 SC846 X9 Universal Air Shroud Components Figure 3-1. SC846 X9 Universal Air Shroud Components B E D A C Item Table 3-1. SC846 X9 Universal Air Shroud Components Description A SC846 X9 universal air shroud component, main body (Part A) B X9 universal air shroud component, moving part (Part B) C X8 air shroud universal component, partition (Part C) D X8 universal air shroud component, tear-drop 55mm (Part D) E X9 universal air shroud component, moving part (Part E) The SC846 X9 universal air shroud comes with the main body and four detachable component partss (Figure 3-1 and Table 3-1). See below for details. These component parts can be used to create multiple different configurations for use in sytems. See Section 3-4 for further details on configurations. The SC846 X9 universal air shroud is optimized for use with Supermicro X8DTx/X9DRx/ H8DGx series mainboards. 3-1

SC846 Air Shroud User s Guide Component Part B Figure 3-2. Moving Component Part B B The SC846 X9 universal air shroud s Component Part B (Figure 3-2) can be moved in and out to resize the X9 universal air shroud s size to fit the mainboard using three sliding positions (labeled 0, 1 and 2 ). The bottom of Component Part B can be detached to allow for cable access under the air shroud. 3-2

Chapter 3: Configuration and Installation Component Part C Figure 3-3. Component Part C Component Part C Alignment Slots C C The SC846 X9 universal air shroud s partition Component Part C (Figure 3-3) can be mounted on the underside of Component Part A by inserting its locking tabs into the four aligned slots provided on part A. Component Part C can only fit onto 12" X 13" motherboards, so it can be removed out if it is not required. 3-3

SC846 Air Shroud User s Guide Component Part D Figure 3-4. Component Part D D D Component Part D Alignment Slots The SC846 X9 universal air shroud s Component Part D, 55mm wide tear-drop module, can be mounted on the underside of Component Part A by inserting its locking tabs into the alignment slots provided on component part A. Component Part D may also be removed out if it is not required (see Figure 3-4). 3-4

Chapter 3: Configuration and Installation Component Part E Figure 3-5. Moving Component Part E E The SC846 X9 universal air shroud s Component Part E (Figure 3-5) can be moved in and out to resize the X9 universal air shroud s size to fit the mainboard using three sliding positions (labeled A, B and C ). The bottom of Component Part E can also be detached to allow for cable access under the air shroud. 3-5

SC846 Air Shroud User s Guide 3-3 Removing Breakable Tabs for Cabling Figure 3-6. Removing the Breakable Tabs Breakable Tabs Component Parts A, B, C and E for the SC846 X9 universal air shroud have breakable tabs that can be permanently removed to allow cabling access if required for your system (see Figure 3-6 for details). To remove, simply cut or break the tabs off from their attachments with a pair of scissors and discard them. 3-6

Chapter 3: Configuration and Installation 3-4 Configuring the SC846 X9 Universal Air Shroud The SC846 X9 universal air shroud can be customized into multiple configurations for Supermicro systems. With all parts attached, with three positions each for Component Parts B and E, and Component Part C and D, many possible combinations can be configured for the SC846 X9 universal air shroud. With component parts detached more configurations are possible. Some recommended example configurations for specific Supermicro motherboards are shown below in Table 3-2. Component Parts not listed in the table have been removed. All are 13.68 x 13 or 12 x 13 Intel Xeon or AMD Opteron motherboards. Table 3-2. Examples of SC846 X9 Universal Air Shroud Configurations Motherboard Slot and Tab Positions H8DG6 Tab Position 1 (Part B), Tab Position B (Part E), Part D and Partition Part C attached X8DT6-F Tab Position 0 (Part B), Tab Position A (Part E), Part D and Partition Part C attached X8DTN+-F Tab Position 0 (Part B), Tab Position A (Part E), Part D attached X9DA6 Tab Position 2 (Part B), Tab Position C (Part E), Partition Part C attached X9DR6-F Tab Position 2 (Part B), Tab Position B (Part E), Partition Part C attached X9DR6-LN4F+ Tab Position 2 (Part B), Tab Position C(Part E) NOTE: The default configuration is with Component Parts A, B, C, D and E already connected (Figure 3-7). 3-7

SC846 Air Shroud User s Guide Figure 3-7. Default Configuration 3-8

Chapter 3: Configuration and Installation 3-5 Installing the SC846 X9 Universal Air Shroud To install the SC846 X9 universal air shroud follow the procedure below. This procedure is the same for all configurations of the SC846 X9 universal air shroud in Supermicro systems. Installing the SC846 X9 Universal Air Shroud in SC846 Chassis Systems 1. Configure the air shroud to fit in your system. See Section 3-4 for details on configuring the air shroud. 2. Secure the rear edge of the SC846 air shroud (component part A) to the top-rear part of the chassis interior. Align the air shroud so that the slot of air shroud s front mounts with the top-front part of the chassis interior (see Figure 3-8). Figure 3-8. Inserting Air Shroud onto a System Mainboard 3-9

SC846 Air Shroud User s Guide 3. Make sure the SC846 X9 universal air shroud is mounted directly on the mainboard of its system so that the air shroud covers the system mainboard over the CPU s and memory slots (see Figure 3-9). Figure 3-9. Air Shroud Mounted into System Chassis NOTE: The air shroud should be mounted flush with the power supply housing, the front fans in the chassis and the rear fans of the chassis if it has been installed properly. Some cables are supposed to go under the air shroud. Detach breakaway tabs if required for cable access. 4. Secure the top cover back on your system. 3-10

Disclaimer The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and proceedings of any kind arising out of or related to such ultra-hazardous use or sale.

SC846 Air Shroud User s Guide Notes