Instrument Configuration Software March dolphin PLUS

Similar documents
DOLPHIN PLUS. Instrument configuration software OLPHIN PLUS

Instrument Configuration Software

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Instruction Manual July sitrans RD SOFTWARE

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

Operating Instructions July milltronics ZSS

Instruction Manual August milltronics ZSS

Ultrasonic Transmitters SITRANS LU150. Operating Instructions 03/2015 SITRANS

Remote Data Manager. SITRANS RD500 Module 8 Inputs, 6 Relay Outputs. Operating Instructions 01/2010 SITRANS

ENVIRORANGER ERS 500 NVIRORANGER ERS 500 COMMUNICATIONS REFERENCE. Instruction Manual August 2001

SMARTLINX INTERFACE MODULE

Instruction Manual February smartlinx interface module MODBUS RTU

SMARTLINX INTERFACE MODULE

Instruction Manual June smartlinx module DEVICENET

SMARTLINX INTERFACE MODULE

Instruction Manual April milltronics SF500

Instruction Manual January milltronics MLC BELT SCALE

Disclaimer of Liability

Instruction Manual March smartlinx interface module REMOTE I/O

Disclaimer of Liability

Instruction Manual February smartlinx interface module PROFIBUS-DP

MultiVOIP SIP Gateways

Ultrasonic Transmitters

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

S7-300 Programmable Controller

Serial Communication Converters & Adapters Instruction Manual

Point Level Transmitters. Pointek CLS200 (Standard) Functional Safety Manual 02/2015. Milltronics

ENVIRORANGER ERS 500 NVIRORANGER ERS 500 USER GUIDE. Instruction Manual PL-600 January Rev. 1.2

MARTLINX INTERFACE MODULE

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

Communication. SmartLinx PROFIBUS DP-V1. Operating Instructions

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP

NanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

4170 POS System Installation Guide

DVAA Series Disk Array for DVR1 Series Digital Video Recorder

PARTNER Contact Closure Adjunct

Instruction Manual March airanger XPL PLUS

MC-12 Software Installation Instructions

DPT - EN1 R1 Users Manual

GRAVIMETRIC GATEWAY PRE-SALES SUPPORT DOCUMENT. December 3, Computer Communications

Blue LED Pulsed Light Source LS-475. Installation and Operation Manual Document Number

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Ultrasonic Transmitters SITRANS LU150. Operating Instructions

INSTALLATION GUIDE ADAPTEC SCSI CARD ULTRA160 SCSI CONTROLLER

Leased-Line Extenders over IP

Port PCI Quick Installation Guide

READ ME FIRST Windows 98/ME/2000

AHA PCI-to-Fast SCSI Host Adapter. Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs

Instruction Manual April 2001 CCUMASS SF500

CA-A480-A Elevator Controller. Reference & Installation Manual

Iomega Microdrive 340MB. Quick Install

NT1-220 Rack. Installation Instructions. Specifications. Contents of Shipping Box. Important Safety Instructions. NT1-220 Rack

CodeLoader. Users Guide. P/N: Rev: OCT04

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

This Errata Sheet contains corrections or changes made after the publication of this manual.

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

High Power over Ethernet Midspans PD Port Model PD Port Model

SMART Response LE. Quick Start Guide. Safety and compliance information...2. Compliance...2. About SMART Response...3. What s in the box?...

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

WebRamp M3 Quick Start. for Windows and Macintosh

EP/2 Installation Instructions

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide

Net-Ritef Continuity and Wiremap Tester Trace-Ritef Tone Generator and Amplified Tone Tracer User's Guide.

Support for Non-Ultra2 SCSI Devices

Optical Multiplexer. Quick Start Guide

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

OnRISC. OnRISC Baltos ir 2110

Integrators. Milltronics BW500 and BW500/L. Operating Instructions 04/2014. Milltronics

Setup Guide. KD-CATHD500Pro. HDBT/HDMI via Single CAT6/STP (Tx/Rx) Extenders with EDID Control, RS-232, IR, HDMI Pass-through and Ethernet

2012 Dealer Price List

Model 7705 Control Module

Serial PROFIBUS Interface

G.SHDSL NTU DECEMBER 2006 LB510A

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Pow-R-Command Human Machine Interfaces. Table of Contents: July Technical Data

DATA CONNECT ENTERPRISE

Quick Start Manual May sitrans PROBE LU (HART)

User Manual TP412RA-4K. Ultra-thin HDBaseT Receiver. 131ft/40m 4K UHD, support audio de-embedding. All Rights Reserved. Version: TP412RA-4K_2017V1.

TAC I/NETTM 1284, 1280, Security Control Unit

SCROLL GAS PRICE DISPLAY SYSTEM ROS SERIES INSTALLATION MANUAL REV 3.0

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

KD-CATHD300Lite. Setup Guide. HDBT/HDMI via Single CAT6/STP (Tx/Rx) Extenders with EDID Control, RS-232, IR

For SITRANS LUT400 (HART) Manual 02/2014

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Instruction Manual July sitrans RD200

PowerBrick-CV User s Manual Edition 2.0

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Transcription:

Instrument Configuration Software March 2004 dolphin PLUS

Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel: This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Unit Repair and Excluded Liability: The user is responsible for all changes and repairs made to the device by the user or the user s agent. All new components are to be provided by Siemens Milltronics Process Instruments Inc. Restrict repair to faulty components only. Do not reuse faulty components. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc. 2005. All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 Email: techpubs.smpi@siemens.com For a selection of Siemens Milltronics level measurement manuals, go to: www. siemens.com/processautomation. Under Process Instrumentation, select Level Measurement and then go to the manual archive listed under the product family. For a selection of Siemens Milltronics weighing manuals, go to: www. siemens.com/processautomation. Under Weighing Technology, select Continuous Weighing Systems and then go to the manual archive listed under the product family. Siemens Milltronics Process Instruments Inc. 2005

Dolphin Plus Introduction Dolphin Plus is the configuration and diagnostic tool used with Milltronics brand measurement instruments. Dolphin Plus Features Introduction manage instrument parameters configure parameters with or without a connected instrument upload and download parameters from an instrument open and save parameter sets from disk monitor parameters in real time view the measured value as a bar graph save and view echo profiles for level instruments Note: Use the online help for instructions on these and other tasks. System Requirements Dolphin-compatible Milltronics instrument 486/66 or better processor (Pentium/120 or better recommended) 16MB RAM (32MB recommended) Windows 95/98, NT 4.0, Windows ME, Windows 2000 640x480 or higher with 256 colours (800x600 or higher resolution recommended) CD-ROM drive for installation RS-232 serial connection RS-485 converter (if required by instrument) Milltronics ComVerter (if required by instrument) 7ML1998IFW01 Dolphin Plus INSTALLATION MANUAL Page 1

Specification For equipment used with Dolphin Plus Milltronics software to configure and monitor Milltronics instruments ComVerter (optional) Power 9V battery (style ANSI / NEDA 1604) Specifications Temperature 20 C to 50 C ( 5 F to 122 F) Enclosure 67mm x 100mm x 35mm Plastic Body Modular jack, RJ-11 (telephone) style Communication Serial from IBM PC optically coupled to Milltronics instruments Patents South Africa: 93/5198 Pending USA, Canada Approvals CE Cable (included) 2.1m (7 ft) Modular RJ-11 (telephone) plug both ends Adapter (included) RJ-11 (telephone) to DB-9 (PC-Serial) RS-232 to RS-485 converter direct connect (powered from PC serial port) optically isolated (externally powered) Page 2 Dolphin Plus INSTALLATION MANUAL 7ML1998IFW01

Connecting Dolphin Plus For parameter and flash upgrades, Dolphin Plus configuration software needs to have access to the instrument. Serial Cable Connection Direct Connect Some instruments (especially rack mount and panel mount models) have a RJ-11 (modular telephone) jack built into the front. Note: The Milltronics BW 500 and SF500 wallmount units have adirect connection inside the closure. For tempory access (upgrades), open lid and plug the jack in. For permananent installation, consult the instrument manual. Required Equipment RJ-11 equipped, two-wire, modular telephone cable (included) long enough to reach from the instrument to your computer. The maximum modular cable length is 2.1m (7 ft.). 9-pin to RJ-11 adapter (included) Installation ComVerter Some instruments (especially wall mount models) have only an infrared programmer connection. A ComVerter is required to place into the instrument s programmer bay. ComVerter in programmer bay 7ML1998IFW01 Dolphin Plus INSTALLATION MANUAL Page 3

Required Equipment ComVerter (Milltronics RJ-11 to IR adapter) RJ-11 equipped, two-wire, modular telephone cable (included) long enough to reach from the instrument to your computer 9-pin to RJ-11 adapter (included) Notes: ComVerter goes into into bay with the Milltronics logo at the bottom Press firmly to insert ComVerter Battery Replacement Before changing the battery, disconnect the RJ-11 cable and remove the ComVerter from the instrument. 1. Remove screw from the back panel. and open the case. nistallation 2. Replace the battery Note: Disconnect ComVerter when not in use to conserve battery life. Page 4 Dolphin Plus INSTALLATION MANUAL 7ML1998IFW01

Terminal Block Some instruments that support Dolphin serial communications also have the option to connect to Dolphin Plus through the terminal block. This permanently connects your computer to the instrument or sets up a central communications area where you can plug into any instrument at the site. Required Equipment RJ-11 equipped, two-wire cable long enough to reach from the instrument to your computer 9-pin to RJ-11 adapter (included) Note: See your Milltronics instrument instruction manual for instructions on wiring to the terminal block. Wiring DB-9 to RJ-11 When wiring a DB-9 (9-pin serial) connection from your computer to a RJ-11 (telephone) connection, use this wiring scheme. Installation Rx Tx signal ground Tx Rx Note: Jumper 4/5 and 7/8 only if hardware flow control is set. Generally, this is not required. The longest run that a telephone-style cable can support is m (7 ft.). To achieve longer runs use twisted pair shielded cable. 7ML1998IFW01 Dolphin Plus INSTALLATION MANUAL Page 5

RS-485 Non Optically Isolated To communicate with some Milltronics instruments you must use the RS-485 protocol. To do this requires an RS-232 to RS-485 adapter (optional). Only use a non-isolated adapter only on very short cable runs. This option works best with a laptop in the field. The advantage of using a non-isolated adapter is that some models will run directly from the computer s serial port and do not require an external power supply. See your Milltronics instrument instruction manual for instructions on wiring to the terminal block. Contact your Siemens Milltronics representative to order this part. nistallation Go to www.siemens.com/processautomation for a list of contacts near you. RS-485 Optically Isolated To communicate with some Milltronics instruments you must use the RS-485 protocol. To do this requires an RS-232 to RS-485 adapter (optional). On longer cable runs, use an optically isolated adapter. These adapters require external power supply and so are more difficult to use with battery-powered laptops in the field. See your Milltronics instrument instruction manual for instructions on wiring to the terminal block. Contact your Siemens Milltronics representative to order this part. Go to www.siemens.com/processautomation for a list of contacts near you. Page 6 Dolphin Plus INSTALLATION MANUAL 7ML1998IFW01

www.siemens.com/processautomation Siemens Milltronics Process Instruments Inc. 1954Technology Drive, P.O. Box 4225 Peterborough, ON, Canada K9J 7B1 Tel: (705) 745-2431 Fax: (705) 741-0466 Email: techpubs.smpi@siemens.com Siemens Milltronics Process Instruments Inc. 2005 Subject to change without prior notice *7ml19981FW01* Printed in Canada Rev. 1.1