AC modules LED linear / area. Engine LLE AC G1 24mm SNC Module LLE ESSENCE

Similar documents
AC modules LED compact

Tunable White LED linear / area. Module QLE G2 PREMIUM QLE PREMIUM

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G1 24mm ADV-SE Modules LLE ADVANCED

PHASED OUT. LED light engine / OLED LED flexible. Module LLE-FLEX Modules LLE FLEX ADVANCED

LED light engines LED flexible

LED light engines LED flexible

LED light engines LED flexible

PHASED OUT. LED light engines ready2apply. Engine SLA ready2apply phase-cut SNC Engine SLA ESSENCE

LED light engines ready2apply

LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

LED light engines ready2apply. Module SLA DC G2 50mm SNC Modules SLA ESSENCE

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE. uengine STARK DLE PREMIUM system

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

LED light engine / OLED LED compact

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Compact fixed output

) Forward voltage (V f. Typ. Max. Typ. [V] [V]

LED Driver Compact fixed output

LX-562A. Linear LED Module, LX Series. 450 ma, 62.7 V. Electrical specifications. Lifetime specifications. Operating Conditions and Characteristics

LED Driver Compact fixed output

LED Driver Compact fixed output

L-iC-282. Tunable White Linear LED Module, L-iC Series. 450 ma, 14.9 V. Electrical specifications. Lifetime specifications

LED Driver DC-String

LED Driver Compact fixed output

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

LED Driver DC-String

Colour Luminous flux Φv Forward voltage Power consumption Tc= 65 C Tc= 25 C Tc= 65 C Tc= 65 C Tc= 65 C

Colour Luminous flux Φv Forward voltage Power consumption Tc= 65 C Tc= 25 C Tc= 65 C Tc= 65 C Tc= 65 C

) Forward voltage (V f. Typ. Typ. Typ. Max. Typ. Typ. Typ. [K] [lm] [lm] [V] [V] [lm/w] [lm/w] Operating Tc. current Temp

LED Driver Compact fixed output

LED Driver Compact fixed output

LED Driver Constant voltage. Driver LC 35W 24V SC SNC essence series

LED Driver Compact fixed output

LED Driver Compact dimming

LED Driver Compact dimming

LED Driver Constant voltage. Driver LC 200W 24V SC SNC essence series

LED Driver Linear / area dimming

LED Driver Linear / area dimming

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Compact fixed output

LED Driver Linear / area dimming

LED Driver Compact fixed output

LED Driver DC-String

LED Driver DC-String

LED Driver Linear / area dimming

LED Driver Linear / area dimming. Driver LC 50W mA 54V 0-10V lp EXC UNV EXCITE series SELV

LED LINE SMD EASY L28/56 W2

LED Driver Compact dimming

LED LINE SMD EASY L14/28/56 W2

LED Driver Constant voltage. Udriver LCU 100/96W 12/24V IP67 EXC EXCITE outdoor IP67 series

LED Driver Linear / area dimming

LED LINE SMD LIGHTBAR

LED Driver Constant voltage. Udriver LCU 180W 12/24V IP67 EXC EXCITE outdoor IP67 series

LED LIGHT PANEL QUADRANT SMD

Linear LED system with matching light engines and drivers in one

LED LINEAR ALLROUND GEN. 3

LED LINE SMD KIT GEN. 3

LED LINE SMD SLIM GEN. 2

MERAKI LED MODULES. 5Years ECO 250X20 - LINEAL CV 12V (250X20MM) >100 I M P R O V I N G T E C H N O L O G Y

LED LINE SMD KIT 3R GEN. 3

LED LINE SMD KIT 3R CSP TUNEABLE

LED INDUSTRY KIT. LED Industry Kit LED Modules for Industry Lighting WU-M-564 LED INDUSTRY KIT WU-M-564

LED LINE CSP TUNEABLE

LINEAR LED BUILT-IN MODULES

LED power supplies Constant voltage. Uconverter LCU 180W 12/24V IP67 TOP Outdoor IP67 series

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-542-G (270X540) LED MODULES FOR OFFICE LIGHTING WU-M-542-G

LED FlatPanel Gen. 2 DALI

LED MODULES FOR MAINS VOLTAGE

LED MODULES FOR MAINS VOLTAGE

PHASED OUT. LED control gear Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO series

LED Driver Linear / area dimming

ALULED IP66/IP V System WHITE, BLUE AND RGB LED MODULES IN FLAT ALUMINIUM PROFILE ALULED IP66/IP67

LED Driver Linear / area dimming

LED LIGHT PANEL SMD. LED Light Panel SMD LED Modules for Office Lighting WU-M-520 (250X250) WU-M-537 (270X270) LED MODULES FOR OFFICE LIGHTING

Input Voltage [Vac] NominalP ower [W]

LED Driver Linear / area dimming

SYM I AND SYM II. LED Industry and Hall Lighting LED LightEngine IP66 LED LIGHTENGINE IP66 LED INDUSTRY AND HALL LIGHTING WU-M-496-C

LED MODULES. LUGA Shop Gen. 5 DMS128 Food LUGA SHOP GEN. 5 DMS128 SPECIAL COLOUR FOOD LUGA SHOP GEN. 5 DMS128. Typical Applications

basicdim Wireless Wireless module for basicdim

LED Driver Linear / area dimming

Fortimo LED Line Gen3

Emergency lighting units PC COMBO

Fortimo LED Line Gen3

LINEAR LED BUILT-IN MODULES

Transcription:

Engine LLE AC G1 24mm SNC Module LLE ESSENCE Product description Module with integrated electronic Ideal for linear luminaires Economic one-stop solution Enables thin designs of luminaires Typ. luminous flux (HO) 2,400 lm, 4,800 lm, 6,000 lm, 6,0 lm and 7,500 lm High system efficacy up to 140 lm/w (HE), 150 lm/w (HO) Colour temperatures 3,000 K, 4,000 K und 6,500 K Module dimensions 24 x 560 mm, 24 x 1,150 mm and 24 x 1,450 mm Colour rendering index CRI > 80 Colour tolerance MacAdam 5 Perfect homogenous light with LINEAR COVER SY Diffuse Push terminals for quick and simple wiring Simple installation (e.g. ACL ENDCAP PUSH-FIX) Self-cooling (no additional heat sink required) Long life-time: 50,000 hours 5-year guarantee LLE AC G1 24x560mm 2400lm SNC LLE AC G1 24x1150mm 4800lm SNC È Standards, page 7 Colour temperatures and tolerances, page 10 LLE AC G1 24x1150mm 6000lm SNC LLE AC G1 24x1450mm 60lm SNC LLE AC G1 24x1450mm 7500lm SNC www.tridonic.com 1

Engine LLE AC G1 24mm SNC Module LLE ESSENCE Technical data Rated supply voltage 2 240 V Input voltage, AC 196 264 V Mains frequency 50 / 60 Hz λ (at 0 V, 50 Hz) 0.95 THD % Flicker < % Beam characteristic 1 Ambient temperature ta -25... +45 C tp rated 75 C tc for 560, 1150 mm 105 C tc for 1450 mm 110 C ESD classification severity level 2 Risk group (IEC 62471:08) RG1 Classification acc. to IEC 631 Built-in Type of protection IP00 4,5 1,6,6 35 5,5 560 1 3 110 tp 315 LLE AC G1 24x560mm 2400lm SNC 4,5 1,6 5,5 tc 0 5xM4 1150 145 335 245 250 175 25 tc tp 10,6 4 145 250 250 50 35 9xM4 LLE AC G1 24x1150mm 4800lm SNC 4,5 1,6 5,5 1150 145 335 245 250 175 tc 25 tp,6 4 145 250 250 50 35 9xM4 LLE AC G1 24x1150mm 6000lm SNC 4,5 1,6 5,5 1450 1 3 227 250 250 250 tc tp,6 50 373 122 250 250 250 155 12xM4 LLE AC G1 24x1450mm 60lm SNC 4,5 1,6,6 5,5 1450 1 3 227 250 250 250 tc tp 50 373 122 250 250 250 155 12xM4 LLE AC G1 24x1450mm 7500lm SNC www.tridonic.com 2

Engine LLE AC G1 24mm SNC Module LLE ESSENCE Ordering data Type Article Colour Packaging Weight number 1 temperature carton 2 per pc. LLE AC G1 24x560mm 2400lm 8 SNC 87500608 3,000 K 36 pc(s). 0.075 kg LLE AC G1 24x560mm 2400lm 840 SNC 87500609 4,000 K 36 pc(s). 0.075 kg LLE AC G1 24x560mm 2400lm 865 SNC 87500610 6,500 K 36 pc(s). 0.075 kg LLE AC G1 24x1150mm 4800lm 8 SNC 87500611 3,000 K 36 pc(s). 0.151 kg LLE AC G1 24x1150mm 4800lm 840 SNC 87500612 4,000 K 36 pc(s). 0.151 kg LLE AC G1 24x1150mm 4800lm 865 SNC 87500613 6,500 K 36 pc(s). 0.151 kg LLE AC G1 24x1150mm 6000lm 8 SNC 87500693 3,000 K pc(s). 0.164 kg LLE AC G1 24x1150mm 6000lm 840 SNC 87500694 4,000 K pc(s). 0.164 kg LLE AC G1 24x1150mm 6000lm 865 SNC 87500695 6,500 K pc(s). 0.157 kg LLE AC G1 24x1450mm 60lm 8 SNC 87500614 3,000 K 36 pc(s). 0.176 kg LLE AC G1 24x1450mm 60lm 840 SNC 87500615 4,000 K 36 pc(s). 0.176 kg LLE AC G1 24x1450mm 60lm 865 SNC 87500616 6,500 K 36 pc(s). 0.176 kg LLE AC G1 24x1450mm 7500lm 8 SNC 87500696 3,000 K pc(s). 0.181 kg LLE AC G1 24x1450mm 7500lm 840 SNC 87500697 4,000 K pc(s). 0.183 kg LLE AC G1 24x1450mm 7500lm 865 SNC 87500698 6,500 K pc(s). 0.181 kg Sample box for design-in LLE AC G1 24x560mm 2400lm 840 SNC QTY4 87500699 4,000 K 4 pc(s). 0.075 kg LLE AC G1 24x1150mm 4800lm 840 SNC QTY4 87500700 4,000 K 4 pc(s). 0.151 kg LLE AC G1 24x1450mm 60lm 840 SNC QTY4 87500701 4,000 K 4 pc(s). 0.176 kg LLE AC G1 24x1150mm 6000lm 840 SNC SAMP 87500705 4,000 K 4 pc(s). 0.157 kg LLE AC G1 24x1450mm 7500lm 840 SNC SAMP 87500706 4,000 K 4 pc(s). 0.182 kg 1 KC approval mark for art. no.: 87500608, 87500609, 87500610, 87500614, 87500615 and 87500616. 2 Orders only in full carton quantities. www.tridonic.com 3

Specific technical data Type Photometric code Typ. luminous flux at tp = 25 C 3 Operating mode HE Typ. luminous flux at tp = 75 C 3 Input current at tp = 75 C 3 Input power at tp = 75 C 3 Efficacy of the system at tp = 75 C Colour rendering index CRI LLE AC G1 24x560mm 2400lm 8 SNC 8/559 1,3 lm 1,0 lm 47 ma 10.4 W 118 lm/w > 80 LLE AC G1 24x560mm 2400lm 840 SNC 840/559 1,410 lm 1,3 lm 47 ma 10.4 W 126 lm/w > 80 LLE AC G1 24x560mm 2400lm 865 SNC 865/559 1,390 lm 1,0 lm 47 ma 10.4 W 124 lm/w > 80 LLE AC G1 24x1150mm 4800lm 8 SNC 8/559 3,070 lm 2,860 lm 107 ma.8 W 119 lm/w > 80 LLE AC G1 24x1150mm 4800lm 840 SNC 840/559 3,270 lm 3,050 lm 107 ma.8 W 118 lm/w > 80 LLE AC G1 24x1150mm 4800lm 865 SNC 865/559 3,2 lm 3,000 lm 107 ma.8 W 126 lm/w > 80 LLE AC G1 24x1150mm 6000lm 8 SNC 8/559 3,960 lm 3,650 lm 121 ma 27.2 W 133 lm/w > 80 LLE AC G1 24x1150mm 6000lm 840 SNC 840/559 4,280 lm 3,940 lm 121 ma 27.2 W 144 lm/w > 80 LLE AC G1 24x1150mm 6000lm 865 SNC 865/559 4,160 lm 3,8 lm 121 ma 27.2 W 140 lm/w > 80 LLE AC G1 24x1450mm 60lm 8 SNC 8/559 4,040 lm 3,760 lm 136 ma.3 W 1 lm/w > 80 LLE AC G1 24x1450mm 60lm 840 SNC 840/559 4,3 lm 4,0 lm 136 ma.3 W 131 lm/w > 80 LLE AC G1 24x1450mm 60lm 865 SNC 865/559 4,240 lm 3,950 lm 136 ma.3 W 129 lm/w > 80 LLE AC G1 24x1450mm 7500lm 8 SNC 8/559 5,190 lm 4,780 lm 152 ma 34.4 W 138 lm/w > 80 LLE AC G1 24x1450mm 7500lm 840 SNC 840/559 5,600 lm 5,160 lm 152 ma 34.4 W 150 lm/w > 80 LLE AC G1 24x1450mm 7500lm 865 SNC 865/559 5,460 lm 5,0 lm 152 ma 34.4 W 146 lm/w > 80 Operating mode HO LLE AC G1 24x560mm 2400lm 8 SNC 8/559 2,500 lm 2,0 lm 95 ma 21,5 W 107 lm/w > 80 LLE AC G1 24x560mm 2400lm 840 SNC 840/559 2,670 lm 2,460 lm 95 ma 21,5 W 114 lm/w > 80 LLE AC G1 24x560mm 2400lm 865 SNC 865/559 2,6 lm 2,4 lm 95 ma 21,5 W 112 lm/w > 80 LLE AC G1 24x1150mm 4800lm 8 SNC 8/559 4,9 lm 4,540 lm 183 ma 41,5 W 109 lm/w > 80 LLE AC G1 24x1150mm 4800lm 840 SNC 840/559 5,270 lm 4,850 lm 183 ma 41,5 W 116 lm/w > 80 LLE AC G1 24x1150mm 4800lm 865 SNC 865/559 5,180 lm 4,770 lm 183 ma 41,5 W 114 lm/w > 80 LLE AC G1 24x1150mm 6000lm 8 SNC 8/559 6,0 lm 5,740 lm 210 ma 47,6 W 119 lm/w > 80 LLE AC G1 24x1150mm 6000lm 840 SNC 840/559 6,7 lm 6,190 lm 210 ma 47,6 W 129 lm/w > 80 LLE AC G1 24x1150mm 6000lm 865 SNC 865/559 6,550 lm 6,0 lm 210 ma 47,6 W 126 lm/w > 80 LLE AC G1 24x1450mm 60lm 8 SNC 8/559 6,340 lm 5,840 lm 228 ma 51,8 W 112 lm/w > 80 LLE AC G1 24x1450mm 60lm 840 SNC 840/559 6,780 lm 6,240 lm 228 ma 51,8 W 1 lm/w > 80 LLE AC G1 24x1450mm 60lm 865 SNC 865/559 6,670 lm 6,140 lm 228 ma 51,8 W 118 lm/w > 80 LLE AC G1 24x1450mm 7500lm 8 SNC 8/559 7,7 lm 7,050 lm 7 ma 54,0 W 1 lm/w > 80 LLE AC G1 24x1450mm 7500lm 840 SNC 840/559 8,340 lm 7,680 lm 7 ma 54,0 W 140 lm/w > 80 LLE AC G1 24x1450mm 7500lm 865 SNC 865/559 8,150 lm 7,500 lm 7 ma 54,0 W 137 lm/w > 80 3 Tolerance range for optical and electrical data: ±10 %. www.tridonic.com 4

ACCES- SORIES LINEAR COVER SY Product description LINEAR COVER for LLE 24 Protection against direct touch for non-selv applications Fast snap on mounting on to LLE 24 with clips or plastic washers High transmission: transparent 94 %, semi-transparent 87 %, diffuse 76 % Made of PMMA Tolerances: ± 1 mm for 597 mm length (ends finished), + mm for 1,0 / 1,500 / 1,600 / 1,800 mm legth (ends raw) R17.5 1.3±0.1 28.6±0.3 24+0.5/-0.4 1.8 35±0.5 Ordering data Type Article number Colour Length Packaging carton Weight per pc. LINEAR COVER SY Transparent 1600mm 28000338 Transparent 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Frosted 1800mm 28000437 Semi-transparent 1,800 mm 12 pc(s). 0.8 kg LINEAR COVER SY Frosted 1600mm 28000339 Semi-transparent 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Frosted 1500mm 28000435 Semi-transparent 1,500 mm 12 pc(s). 0.244 kg LINEAR COVER SY Frosted 10mm 28000422 Semi-transparent 1,0 mm 12 pc(s). 0.5 kg LINEAR COVER SY Frosted 597mm 28000340 Semi-transparent 597 mm 12 pc(s). 0.102 kg LINEAR COVER SY Diffuse 1800mm 28000438 Diffuse 1,800 mm 12 pc(s). 0.8 kg LINEAR COVER SY Diffuse 1600mm 28000341 Diffuse 1,600 mm 12 pc(s). 0.272 kg LINEAR COVER SY Diffuse 1500mm 28000436 Diffuse 1,500 mm 12 pc(s). 0.257 kg LINEAR COVER SY Diffuse 10mm 28000434 Diffuse 1,0 mm 12 pc(s). 0.5 kg LINEAR COVER SY Diffuse 597mm 28000342 Diffuse 597 mm 12 pc(s). 0.102 kg www.tridonic.com 5

ACCES- SORIES ACL ENDCAP LLE24 PUSH-FIX Product description ENDCAP for LLE 24 Fast snap on mounting (sheet thickness 0.5 1.0 mm), for drilling hole 4 mm Made of Polycarbonat.3 12 R19.2 R10.5 5.0 38.4 6 Ordering data Article Type Colour Packaging carton Weight per pc. number ACL ENDCAP LLE24 PUSH-FIX 28001037 White 480 pc(s). 0.003 kg ACCES- SORIES CLIP 4.3mm Product description Clip for fixation of LED modules with 4.3 mm holes Fast snap on mounting (sheet thickness 0.5 1.0 mm) For drilling hole 4 mm Clip made of Polycarbonat 2.2±0.05 ø9 7.4 1.2 ø5.3 ø3.6 Ordering data Type Article number Colour Packaging bag 1 Weight per pc. ACL CLIP 4.3mm PUSH-FIX 28001036 White 500 pc(s). 0.001 kg 1 Minimum sales quantity 500 pcs. www.tridonic.com 6

1. Standards IEC 55015 IEC 61000-3-2 IEC 61000-3-2 IEC 61000-4-2 IEC 61347 IEC 631 EN 62471 1.1 Photometric code Key for photometric code, e. g. 8 / 559 1 st digit 2 nd + 3 rd digit 4 th digit 5 th digit 6 th digit Luminous flux after 25% Code CRI McAdam after of the life-time (max.6000h) Colour temperature in McAdam 25% of the Code Luminous flux 7 70 79 initial life-time 7 70 % Kelvin x 100 8 80 89 (max.6000h) 8 80 % 9 90 9 90 % 1.2 Energy classification Type Operating mode Energy classification LLE AC G1 24x560mm 2400lm 8 SNC HE A+ LLE AC G1 24x560mm 2400lm 840 SNC HE A+ LLE AC G1 24x560mm 2400lm 865 SNC HE A+ LLE AC G1 24x1150mm 4800lm 8 SNC HE A+ LLE AC G1 24x1150mm 4800lm 840 SNC HE A+ LLE AC G1 24x1150mm 4800lm 865 SNC HE A+ LLE AC G1 24x1150mm 6000lm 8 SNC HE A+ LLE AC G1 24x1150mm 6000lm 840 SNC HE A++ LLE AC G1 24x1150mm 6000lm 865 SNC HE A++ LLE AC G1 24x1450mm 60lm 8 SNC HE A+ LLE AC G1 24x1450mm 60lm 840 SNC HE A+ LLE AC G1 24x1450mm 60lm 865 SNC HE A+ LLE AC G1 24x1450mm 7500lm 8 SNC HE A+ LLE AC G1 24x1450mm 7500lm 840 SNC HE A++ LLE AC G1 24x1450mm 7500lm 865 SNC HE A++ LLE AC G1 24x560mm 2400lm 8 SNC HO A+ LLE AC G1 24x560mm 2400lm 840 SNC HO A+ LLE AC G1 24x560mm 2400lm 865 SNC HO A+ LLE AC G1 24x1150mm 4800lm 8 SNC HO A+ LLE AC G1 24x1150mm 4800lm 840 SNC HO A+ LLE AC G1 24x1150mm 4800lm 865 SNC HO A+ LLE AC G1 24x1150mm 6000lm 8 SNC HO A+ LLE AC G1 24x1150mm 6000lm 840 SNC HO A+ LLE AC G1 24x1150mm 6000lm 865 SNC HO A+ LLE AC G1 24x1450mm 60lm 8 SNC HO A+ LLE AC G1 24x1450mm 60lm 840 SNC HO A+ LLE AC G1 24x1450mm 60lm 865 SNC HO A+ LLE AC G1 24x1450mm 7500lm 8 SNC HO A+ LLE AC G1 24x1450mm 7500lm 840 SNC HO A++ LLE AC G1 24x1450mm 7500lm 865 SNC HO A++ 2. Thermical details 2.1 tc point, ambient temperature and life-time The temperature at tp reference point is crucial for the light output and life-time of a LED product. For LLE a tp temperature of 75 C has to be complied in order to achieve an optimum between heat sink requirements, light output and life-time. Compliance with the maximum permissible reference temperature at the tc point must be checked under operating conditions in a thermally stable state. The maximum value must be determined under worst-case conditions for the relevant application. 2.2 Storage and humidity Storage temperature -... +80 C Operation only in non condensing environment. Humidity during processing of the module should be between to 70 %. 2.3 Thermal design and heat sink The rated life of LED products depends to a large extent on the temperature. If the permissible temperature limits are exceeded, the life of the LLE will be greatly reduced or the LLE may be destroyed. 3. Installation / wiring 3.1 Wiring L N 3.2 Wiring type and cross section The wiring can be solid or flexible wire with a cross section of 0.2 to 0.75 mm². For the push-wire connection you have to strip the insulation (7 9 mm). wire preparation: 0.2 0.75 mm² 7 9 mm Inserting stranded wires / removing wires by lightly pressing on the push button. 3.3 Operating mode selector The operating mode is set via slide switch. Do not change the mode during operation of the module. HO HE www.tridonic.com 7

3.3 Mounting instruction None of the components of the LLE (substrate, LED, electronic components etc.) may be exposed to tensile or compressive stresses. Max. torque for fixing: 0.5 Nm. The LED modules are mounted onto a heat sink with a non-conductive mounting item like an ACL Clip 4.3 mm or a plastic rivet. If mounted with conductive screws additional insulation is necessary. A plastic washer can be used to keep the required creepage and clearance distances. Cut-out of mounting plate: LLE AC G1 24x560mm 2400lm SNC 3.4 Safety instructions A protection against direct touch (test finger) to the module has to be guaranteed. This is typically achieved by means of a non removable light distributor over the module. For basic insulation ensure creapage and clearance according to below drawings. At least 1.5 mm of clearance and 2.5 mm of creapage to active parts must be ensured. LLE AC G1 24x560mm 2400lm SNC 142 193 193 21 95 2 100 100 193 12 193 15 LLE AC G1 24x1150mm 4800lm SNC LLE AC G1 24x1150mm 6000lm SNC 21 110 310 145 125 125 125 25 10 272 75 73 25 LLE AC G1 24x1150mm 4800lm SNC LLE AC G1 24x1150mm 6000lm SNC 155 272 272 75 73 75 73 LLE AC G1 24x1450mm 60lm SNC LLE AC G1 24x1450mm 7500lm SNC 21 70 3 122 125 125 125 19 264 58 76 8 Chemical substance may harm the LED module. Chemical reactions could lead to colour shift, reduced luminous flux or a total failure of the module caused by corrosion of electrical connections. Materials which are used in LED applications (e.g. sealings, adhesives) must not produce dissolver gas. They must not be condensation curing based, acetate curing based or contain sulfur, chlorine or phthalate. Avoid corrosive atmosphere during usage and storage. 272 LLE AC G1 24x1450mm 60lm SNC LLE AC G1 24x1450mm 7500lm SNC 139 264 58 76 264 264 Keep clear area 58 76 58 76 75 73 3.5 EOS/ESD safety guidelines The device / module contains components that are sensitive to electrostatic discharge and may only be installed in the factory and on site if appropriate EOS/ESD protection measures have been taken. No special measures need be taken for devices/modules with enclosed casings (contact with the pc board not possible), just normal installation practice. Please note the requirements set out in the document EOS / ESD guidelines (Guideline_EOS_ESD.pdf) at: http://www.tridonic.com/esd-protection www.tridonic.com 8

4. Life-time 4.1 Life-time, lumen maintenance and failure rate The light output of an LED Module decreases over the life-time, this is characterized with the L value. L70 means that the LED module will give 70 % of its initial luminous flux. This value is always related to the number of operation hours and therefore defines the life-time of an LED module. As the L value is a statistical value and the lumen maintenace may vary over the delivered LED modules. The B value defines the amount of modules which are below the specific L value, e.g. L70B10 means 10 % of the LED modules are below 70 % of the inital luminous flux, respectivly 90 % will be above 70 % of the initial value. In addition the percentage of failed modules (fatal failure) is characterized by the C value. The F value is the combination of the B and C value. That means for F degradation and complete failures are considered, e.g. L70F10 means 10 % of the LED modules may fail or be below 70 % of the initial luminous flux. 4.2 Lumen maintenance LLE AC G1 24x560mm 2400lm SNC LLE AC G1 24x1150mm 4800lm SNC LLE AC G1 24x1450mm 60lm SNC tp L90 / F10 temperature L90 / F50 L80 / F10 L80 / F50 L70 / F10 L70 / F50 55 C 16,000 h 19,000 h,000 h 36,000 h 47,000 h 50,000 h 65 C 16,000 h 19,000 h 29,000 h 36,000 h 45,000 h 50,000 h 75 C 15,000 h 19,000 h 28,000 h 36,000 h 43,000 h 50,000 h 85 C 10,000 h 12,000 h 19,000 h 24,000 h 28,000 h 37,000 h LLE AC G1 24x1150mm 6000lm SNC LLE AC G1 24x1450mm 7500lm SNC tp L90 / F10 temperature L90 / F50 L80 / F10 L80 / F50 L70 / F10 L70 / F50 55 C,000 h 38,000 h 48,000 h 50,000 h 50,000 h 50,000 h 65 C 17,000 h 27,000 h 35,000 h 50,000 h 50,000 h 50,000 h 75 C 11,000 h 16,000 h 22,000 h 34,000 h 35,000 h 50,000 h 85 C 8,000 h 11,000 h 15,000 h 22,000 h 24,000 h 35,000 h 4.3 Switching capability 25,000 cycles Tested according to IEC 62717 Cl 10.3.3 s on / s off 5. Electrical values 5.1 Maximum loading of automatic circuit breakers Automatic circuit breaker type C10 C13 C16 C B10 B13 B16 B Inrush current Installation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 I max time LLE AC G1 24x560mm 2400lm SNC 60 80 100 125 60 80 100 125 25 A 5 µs LLE AC G1 24x1150mm 4800lm SNC 40 50 65 40 50 65 A 5 µs LLE AC G1 24x1150mm 6000lm SNC 40 50 65 40 50 65 A 5 µs LLE AC G1 24x1450mm 60lm SNC 25 40 50 25 40 50 A 5 µs LLE AC G1 24x1450mm 7500lm SNC 25 40 50 25 40 50 A 5 µs 5.2 Isolation and electric strength testing of luminaires Electronic devices can be damaged by high voltage. This has to be considered during the routine testing of the luminaires in production. According to IEC 60598-1 Annex Q (informative only!) or ENEC 3-Annex A, each luminaire should be submitted to an isolation test with 500 V DC for 1 second. This test voltage should be connected between the interconnected phase and neutral terminals and the earth terminal. The isolation resistance must be at least 2 MΩ. As an alternative, IEC 60598-1 Annex Q describes a test of the electrical strength with 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices this test must not be conducted. 5.3 AC operation Mains voltage: 2 240 V 50/60 Hz 196 264 V 50/60 Hz for safety www.tridonic.com 9

6. Photometric charcteristics 6.1 Coordinates and tolerances according to CIE 1931 The specified colour coordinates are integral measured by a current impulse with typical values of module and a duration of 100 ms. The ambient temperature of the measurement is ta = 25 C. The measurement tolerance of the colour coordinates are ± 0.01. 6.2 Colour coordinates for LED module without housing 3,000 K x0 y0 Centre HE 0.4339 0.4025 Centre HO 0.4338 0.40 0,4250 100 0,40 0,4150 0,4100 0,4050 0,4000 0,3950 norm. intensity [%] 80 60 40 0,3900 0,3850 0,4150 0,40 0,4250 0,40 0,4350 0,4400 0,4450 MacAdam Ellipse: 5SDCM 0,4500 0,4550 0 380 4 460 500 540 580 6 660 700 740 780 wave length [nm] 4,000 K x0 y0 Centre HE 0.3819 0.3792 Centre HO 0.3818 0.3797 0,4000 100 0,3950 0,3900 0,3850 0,3800 0,3750 0,3700 norm. intensity [%] 80 60 40 0,3650 0,3600 0,3650 0,3700 0,3750 0,3800 0,3850 0,3900 0,3950 MacAdam Ellipse: 5SDCM 0,4000 0,4050 0 380 4 460 500 540 580 6 660 700 740 780 wave length [nm] www.tridonic.com 10

6,500 K x0 y0 Centre HE 0.3122 0.3274 Centre HO 0.31 0.3282 0,3500 0,3450 0,3400 0,3350 0,30 0,3250 0, 0,3150 norm. intensity [%] 100 80 60 40 0,3100 0,2950 0,00 0,50 0,3100 0,3150 0, 0,3250 0,30 0,3350 0 380 4 460 500 540 580 6 660 700 740 780 MacAdam Ellipse: 5SDCM wave length [nm] 6.3 Light distribution The optical design of the LLE product line ensures optimum homogenity for the light distribution. relative intensity Iv/Iv,max -10-100 - -40 80-50 60-60 40 0 10 40 50 60 70 80-90 -100-80 -60-40 - 0 40 60 80 100 90 The colour temperature is measured integral over the complete module. The single LED light points can have deviations in the colour coordinates within MacAdam 5. To ensure an ideal mixture of colours and a homogenious light distribution a suitable optic (e. g. PMMA diffuser) and a sufficient spacing between module and optic (typ. 5 cm) should be used. 7. Miscellaneous 7.1 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warranty claim. www.tridonic.com 11