IS-IR SAUNA ROUGH-IN- ###############

Similar documents
EcoSystem to 0 10 V- Interface

Target Interface / Construction Compliance Inspection Checklist

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation Notes TII Model 341 Protector

Series 575. Vertical Flow Modular Softwall Cleanroom. Series 575 Vertical Flow Modular Softwall Cleanroom

Gadget Freak Case #238: Controller Adjusts Garage Lights Build Instructions

PANELITE ENCLOSURE LIGHTS OVERVIEW

mws-sn monorail wall standoff (8) MWS-SN Monorail Wall Standoff Order seperate from Kit: (4) MW-REW-SN Rebel Fixture for Monorail Wall

COCKPIT DOOR SURVEILLANCE SYSTEM - DESCRIPTION AND OPERATION

Specialized Lighting Solutions, Inc. SLS DALI CONTROLLERC

SCC5-RM. Coloronix, Inc West Jefferson Boulevard Los Angeles, California (323)

Electrical Demand Specification (Reference SOP: )

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module

What is Zip? Zip Modules... 6 Zip Network... 6 Zip Master Quick Start... 7

NT-2300 Series Dual Circuit Track System & Accessories

Spring Test 9 due 05/11/2013

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

QuantumR Light Management Hub

Installation Instructions

JNIOR Series 4. A Network I/O Resource Utilizing the JAVA Platform. JNIOR Series 4 with 4 Relay Output Expansion Module. Version 5.

ICS Entrance Management Sign Installation Guide. Version 1.0

Product Data Sheet. BMS/Graphics Interface. Features

QuantumR Light Management Hub (QP2)

LED Tape Light Radiance Series

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

CODE 50108, 50110, 50164, 50165

Entry Level Assessment Blueprint Electrical Occupations

INSTALLATION INSTRUCTIONS

Instruction Manual HPH-8

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories

Ink-Dot Series II Driver

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Effective May 2018 Supersedes October 2017

Target Interface / Construction Compliance Inspection Checklist

Infinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Installation OVERVIEW

Operating Instructions

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

NULB-5 Pro90 Series Ultra-Low Profile Linear LED Lightbar Pro90. Source: 8W / 400+ Lumens / 90+ CRI per foot LED. Page 1 of 7

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

Switched Relay Controller - Relay Panel with Breakers

Model 7416LED

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE

Dual Relay Luminaire Control Module Wiring and installation manual Light is OSRAM

Portable Gas Monitor (PGM-IR) Infrared Sensor Replacement Instruction

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

Quantum Light Management Hub (QP3) for Quantum Select

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.

Two Circuit Track Power System IS24 / IS26 / IS28

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

ICLS Installation Guidelines

Strand Lighting Specification

Spring Test 17 due 06/14/2013

Specifications for Modular Sound Shadow Sound Masking Sound Management Group, LLC.

SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

TOKISTAR LIGHTING INSTRUCTION MANUAL

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance

VersaLamp High Bay/Light Fixture Installation Instructions

Model HM-535 Power Supply Installation and Service Instructions

How to choose the correct Mount Kelvin central unit

Pegasus HC Lighting Control Panel

Lightbar 90+ NULB Series 24V Ultra-Low profile Linear LED Source: 4 Watts / 220 Lumen per foot

CONTROL PROTOCOL Motorized Projection Screens

20AMP Plug Load Controller

Springtree Spatial Wash COB WW

DOCKING STATION SPECIFICATIONS

ILC LightLEEDer MicroLite 1000P Retrofit Installation

NETRONICS HS3500 CONTROLLER

Series Amp Pad Mount Quick Connect Input and Output Power Panels

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

CONTROLLERS TECHNICAL DATA SHEET

VCM Systems Vehicle Control Module Systems

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

MX1 Reversible AC Motor Controller. Supplementary Wiring Examples

HomeWorks Remote Power Feed-Through Panels

EHS INC. Electric Heating Systems, Inc. 109 North Gold Drive Robbinsville, NJ Phone: (609) Fax: (609)

SCD96 DMX Output Interface. Installation guide

Basketball Shot Clock Set LX2180 Manual

Installation, Operation

NULB-48LED 48" Ultra-Low Profile Linear LED Lightbar Source: 16W LED

Connecting a Cisco Output Module

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

6222 Two Door Module Technical Operations Manual

Instruction / Installation Sheet DataComm Electronics WH Recessed Pro-Power Kit with Duplex Receptacle and Straight Blade Inlet

Blueprint Drawings & Wiring Diagrams. for branch circuits

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Rev Single-Channel Pulse Modulating Anti-Sweat Control (SC-PMAC) Installation and Operation Manual

GR 2400 PLANNING GUIDE. Important Note:

Spring Test 5 due 4/26/2013

PLC Racks IC697CHS782/783

Installing the ILC LightSync 4.3 or 7 Touch Screen Station. Rev. B

Controllers and Switchers

v2.5 was updated May 10, v2.6 is an updated copy from March 1, 2017.

Now with Picture Memory

QuickNetwork QND200 Distribution Panel

Transcription:

IS-IR SAUNA ROUGH-IN- ############### 115 Bowes Rd, Unit 2, Concord, ON. L4K 1H7 Ph:905-738-4017 / 800-387-7029 sales@saunafin.com www.saunafin.com Infrared saunas are much more time consuming to install as compared to traditional saunas. Each emitter needs to be wired individually and spaced according to room size and bench configuration. Wiring if often done as sauna is being built. Along with this rough in guide, you will be provided with up to three manuals: One for the cedar sauna material installation and two for the infrared. Please read through all carefully, before starting. Wall emitters are mounted vertically. Size: 27" or 15" wide x 39" high (For combination sauna, there must be 5" of clearance above the traditional sauna heater and the bottom of any IR frame. 84" IR 160 (17x37) 24" - Top Bench Air outlet (high) IR 110 (11x39) 16" - Bottom Bench 60" IR 110 (11x39) EXAMPLE ONLY Air Inlet (low) R/O = 26" x 76-1/2" Door = 24" x 74" Carbon Infrared IS 401, 240 volt 2300 watts Traditional: 6kw 240 volt

SUPPLY WIRE/BREAKER (not Included) ## amp, 240 volt breaker (Non GFI) ##/2 from panel to CB PK contactor /relay box ##/2 from CB PK contactor /relay box to traditional heater 14/2 wire for IR emitters. From CB PK box to nearest emitter. Then daisy chain to all other emitters. NOTE: If trying to maintain low EMF, use BX armored cable rather than romex. CONTROL Install outside sauna Connect low voltage cable from the SaunaLogic IS control to JT1 of the circuit board in the CB PK Box. SENSOR INSTALLATION Install five-conductor cable provided for the sensor to the CB PK Box. Refer to Diagram 1 for location. Connect sensor cable to JT2 of the circuit board in the CB PK Box. Feed the 17 ft "low voltage" sensor wire from the sensor location to the CB PK box location. Sensor wire must be routed completely separate (as per low voltage electrical wiring codes) from any wiring carrying over 50 volts. It may be necessary to drill holes to string the wire through the studs or ceiling joists. Connect wires to JT2 on the circuit board inside the CB PK box LIGHT PACKAGE (OPTIONAL) The lighting package consists of 3 color therapy lights, 2 interior lights, 3 exterior lights, and the cables to connect the light assemblies to the CB PK box. The cables provided are 176" from CB PK box to the first light fixture. Then the cable is 60" between the fixtures. All cable lengths are similar depending on the number of fixtures. Connect the color therapy light cable to Color Lamp of the circuit board in the CB PK Box. Connect the cable from Interior lights to the connector labels Interior Lights. Connect the cable from exterior lights to the connector labels Exterior Lights Connect the high limit sensor cable to JT13 of the circuit board in the CB PK Box. (Traditional sauna heater is optional). Light Fixture Installation: Cut 2 3/4" holes in tongue and groove boards for light fixtures. Ensure the lighting cables reach the hole locations TRADITIONAL SAUNA HEATER WIRING TRADITIONAL SAUNA HEATER (If ordered). Install wire from the CB PK box to the location of the bottom of the sauna heater. A two conductor cable is provided with the sauna heater for the high limit safety switch. Pre install wire in the wall. The traditional sauna system will not work if the wires and switch are not connected. Note: Run supply wire from CB PK panel to traditional heater - 1' above floor.

IR EMITTER INSTALLATION Emitters come with 54" wire whip. Drill hole for whip. Feed whip or guide string from hole to one gang box mounted close to floor as shown in installation guide. Each IR emitter to be connected to an electrical junction box. All IR emitters should be grounded. Use14-2 AWG wire w/ground from the CB PK Box to closest IR emitter. Daisy chain the wire from the first IR emitter to box for next and continue for each IR emitter connection. Note: If trying to maintain low EMF, use BX armored cable rather than romex. IR assembly can be installed above the traditional sauna heater. There has to be 5" of clearance above the traditional sauna heater and the bottom of the IR assembly. See Diagram 1 for specific spacing requirements. Quantity: # Quantity: # Quantity: # (bench riser) Back view of whip Rough In Emitter Wire There is a 54" whip centered one emitter has, 1-1/2" from bottom edge. Walls: Rough in hole for wire whip at 38-1/2" above finished floor (aff) (based top 36" top bench) Over optional Viki traditional heater: Requires 5" Clearance above heater. Rough in for wire at 41" aff Bench riser (1or2): locate one-gang electrical box, so that whip at one end will reach.