Device Configurator ECI-1

Similar documents
Flow - magnetic inductive - probe form

Flow - gearwheel. Characteristics. Applications. Volumetric metering system for self-lubricating fluids (oils,..), excellent viscosity independence.

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

Level sensor Stainless steel version Model RLT-1000, for industrial applications

MDT 2000 Magnetostrictive linear position transducer

Turbine Wheel Flow Meter/ Monitor for Liquids

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Product Catalog. Represented by Norstat Inc. in North America

Distance and Position Sensors

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Data Sheet for Linear Sensors

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Minimum < 0.2 ms, maximum 2 ms, typical 1 ms; On request: Delays or holding times for bubble events % relative humidity (not condensing)

ECI 1319 EQI 1331 EBI 1335 Absolute Rotary Encoders without Integral Bearing. Product Information

LS 6600 Technical Datasheet

Linear Position Transducer HLT 1000-R2

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Pile Driver Weld Immune Sensors

Inductive displacement measurement system model series IE25P with programmable analogue interface

Industrial Hydraulics FAQs

Electronic Temperature Switches. Catalogue. Electronic Temperature Switches. Control. Overview. every move

Electronic Level Switch ENS 3000

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

Linear Position Transducer HLT 1000-R2

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Mating connectors and cable sets for valves and sensors in hydraulics

ScreenLine Accessories MB model

Product Overview Automation

Mounting holes. Transmitter optics. 8-pol. fem. conn. Binder Series 712 (connection to PLC) Connecting cable: cab-las4/pc or cab-4/usb or cab-4/eth

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

(see also technical drawings) Width with inlay

GSV-1A4 M12/2 M12/2. Highlights

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

BTL6-A_10-M -A1-S115. Data Sheet. english

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

INSTALLATION GUIDE Magnetostrictive Sensor Series MAZ

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Supplementary instructions. Plug connector ISO for continuously measuring sensors. Document ID: 30375

Supplementary instructions. Plug connector ISO for level sensors. Document ID: 30380

MMT330 Series Moisture and Temperature Transmitters for Oil

Product Information. ECI 4090S Absolute Rotary Encoder with 180 mm Hollow Shaft and DRIVE-CLiQ Interface for Safety-Related Applications

APS4 Inductive Proximity Sensors

Level and temperature switch Nivotemp NT-M, NT-MD

Inductive Proximity Sensor

Pressure sensors SDE1, with display

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI

Level measurement CleverLevel LBFI Point level detection

Datasheet DE DB_EN_DE44_LCD Rev. ST4-C 07/17. Digital 2-channel differential pressure switch/transmitter with colour-change LCD * *

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Product Information ECI 1118 EQI 1130 ECI 1119 EQI Absolute Rotary Encoders without Integral Bearing

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

Technical data. General specifications. Indicators/operating means

Standard PROFINET IO. RoHS. High shaft load capacity. High protection level. Flexible

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Hardware Manual RM Display 2401

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

fischer connectors 4032 Series HIGH-PERFORMANCE IN A VERSATILE PACKAGE MEDICAL PORTABLE EQUIPMENT DATA ACQUISITION INSTRUMENTATION Edition 1.

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Ø 11,4 21,5. M9 x 0,5 Ø 12 Ø 11,4. M9 x 0,5 Ø 12. M9 x 0,5

IK4A (with ONDA technology)

Sensor Actuator Interface. Catalogue

bidirectionally as well as the rotation sense of shafts. With absolute encoders instead, each incremental

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS.

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Absolute Encoders Multiturn

Analog micro push button

Supplementary instructions. Plug connector Harting HAN 7D. For point level sensors. Document ID: 34456

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

Round Water-resistant Connectors (M12) XS2

POSIROT. PRAS2EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

RoHS. High shaft load capacity. Shock / vibration resistant

Supplementary instructions. Plug connector Harting HAN 8D. for continuously measuring sensors. Document ID: 30376

Float switch For industrial applications Model RLS-1000

MPreC - Pressure Relief Device Order specification sheet

accessories cable sockets SENSORFLEX single side ready-made

standard, short, preferential, top

Product Information. ECI 4090 S Absolute Rotary Encoder with 90 mm Hollow Shaft and DRIVE-CLiQ Interface for Safety-Related Applications

RACO-ELECTRIC CYLINDER MODULAR SYSTEM HEAVY DUTY SERIES (TYPE 1) SIZE 4,5,6,7,8

Inductive sensor NI3-EG08K-Y1-H1341

Pressure sensors SPAN

BCC Part Number Matrix Breakdown Balluff cables, cordsets & connectors for industial automation equipment

More Precision. colorsensor // Colour Sensors, LED Analyzers

Incremental encoders Solid shaft with EURO flange B pulses per revolution

Field bus connections Link structure DDL Link structure DDL, bus coupler. Brochure

Proximity sensors SME-8M, for T-slot Technical data Magnetic reed

L-LAS Series L-LAS-CAM-256 L-LAS-CAM-256-SL L-LAS-CAM-512 L-LAS-CAM-512-SL L-LAS-CAM-1024 L-LAS-CAM-1024-SL. Design. L-LAS-CAM Series Line Cameras

Han-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu

Level- and temperature sensor Nivotemp NT M-XP

Transcription:

Honsberg Instruments GmbH Tenter Weg 2-8 42897 Remscheid Germany Fon +49 (0) 2191-9672 - 0 Fax - 40 www.honsberg.com info@honsberg.com Device Configurator ECI-1 Handling and operation Connection The device configurator is intended for temporary connection to the application. It is connected between the the existing sensor lead and the sensor. Power supply is via the supply to the sensor and the computer's USB port. When inactive (no communication), the configurator behaves completely neutrally; all signals from the sensor remain available to the application. During communication between computer and sensor, the signal wirings are separated in the configurator, so that in this state the sensor's output signals are not available. Can be used on site for: parameter modification firmware update adjustment of inputs and outputs Can be connected via USB Characteristics The device configurator ECI-1 is an interface which allows the connection of microcontroller-managed HONSBERG sensors to the USB port of a computer. Together with the Windows software "HONSBERG Device Configurator" it enables the modification of all the sensor's configuration settings the reading of measured values the adjustment of inputs and outputs firmware updates Technical data Supply voltage 12..30 V DC (depending on the connected sensor) and via USB Power < 1 W consumption Connection Sensor cable bushing M12x1, 5-pole, straight length approx. 50 cm Lead device connector M12x1, 5-pole USB USB bushing type B Operating 0..50 C temperature Storage -20..+80 C temperature Dimensions of 98 mm (L) x 64 mm (W) x 38 mm (H) housing Housing material ABS Ingress protection IP 40 To connect 4-pole leads without a middle hole to the installed 5-pole device connector, adapter K04-05 is included. 4-pole leads with a middle hole can be used without an adapter. Device configurator (for scope of delivery, see the diagram below) Scope of delivery 1. Device configurator ECI-1 2. USB cable 3. Adapter K04-05 4. Plug KB05G 5. Cable K05PU-02SG 6. Carrying case Incl. software Accessories: Mains connector 24 V DC (with fitted round plug connector, 5-pole, incl. international plug set) ECI-1 EPWR24-1 Replacement parts: M12x1 adapter 4- / 5-pole K04-05 PUR cable, 5-pole, shielded K05PU-02SG with round plug connector M12x1 Round plug connector M12x1, 5-pole KB05G (without cable) 4 5 6 1 2 3 pi-ho-sm-flow-calorimetry_e V1.00-01 33

Options LABO transmitter - Temperature up to 150 C All LABO transmitters can be used with electronics positioned in a separate area with media temperatures up to 150 C. OMNI - Tropical model This OMNI electronic option should be used where temperatures change quickly, or for external installations (the device is filled with oil, and thus prevents condensate formation in the electronics housing, even under adverse circumstances) Accessories Filter Type ZV Type ZE The HONSBERG filters are offered for the protection of the devices from dirt or as independent components for coarse and fine filtration of liquids. For more information, see additional product information. 34 pi-ho-sm-flow-calorimetry_e V1.00-01

Crimp connection For push-in sensors Ø12 mm Metal 1. 2. 3. 4. 5. ADQ- 012 G 015 A 012 for sensors Ø12 mm G thread G 3. Connection size 015 G 1 / 2 A 4. Process connection A male thread 5. Construction material K stainless steel 1.4571 M brass Plastic 1. 2. 3. 4. 5. ADQ- 012 M 020 A P1 012 for sensors Ø12 mm M metric thread 3. Connection size 020 M20x1.5 4. Process connection A male thread 5. Construction material P1 plastic PA66 pi-ho-sm-flow-calorimetry_e V1.00-01 35

Weld-on adapter For crimp connector ADQ-012G015A. 1. 2. 3. 4. 5. ADG- 015 G S 026 K 015 G 1 / 2 A G female thread 3. Installation S weld-on adapter 4. Welded-on nozzle 026 26 mm 5. Construction material K stainless steel 1.4571 Flange For crimp-on threaded connection ADQ-012M20A. Plastic 1. 2. 3. 4. ADM- 020 F 054 P2 020 M20x1.5 F flange 3. Flange size 054 54 mm 4. Construction material P2 plastic POM black 36 pi-ho-sm-flow-calorimetry_e V1.00-01

Round plug connector 4 / 5-pin Self-assembly 1. 2. KB 1 brown 2 white 3 blue 4 black 3 blue 2 white 1 brown 4 black 5 grey 1. Number of pins 04 4-pin 05 5-pin 2. Connector output G straight W elbow 90 Packaged 1. 2. 3. 4. 5. 6. PU - 1. Number of pins K 4-pin K05 5-pin 2. Cable material PU PUR 3. Cable length 02 2 m 05 5 m 10 10 m 4. Shielding N shielding not applied to coupling S shielding applied to coupling 5. Connector output G straight W elbow 90 6. Shielding A shielded pi-ho-sm-flow-calorimetry_e V1.00-01 37

Panel meter OMNI-TA Primary Sensors 0..10 V 4..20 ma Frequency Converter with the same data as the OMNI in situ electronics; but as an external panel-mounting variant with IP 67 housing. OMNI - Remote Primary Sensors 0/2..10 V 4/0..20 ma Frequency Function is identical to OMNI-in situ. Connection to the sensor is, however, made by wire, and so the measurement point and display location can be apart 38 pi-ho-sm-flow-calorimetry_e V1.00-01