FEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)

Similar documents
FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code

FEMA ELECTRÓNICA. Panel meter for process signals in ma and Vdc. Accepts both active and passive

Panel Meters Series M40 Model M40-A Amplicon.co m IT and Instrumentation for industry

Series BDF Serial ASCII

Series K. K40-RTU. Display for Modbus RTU protocol. User s Manual. Tel. (+34)

SIGNAL CONVERTERS ELECTRONIC INSTRUMENTATION FOR INDUSTRY. Small catalogue. Tel. (+34)

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

Tempco Instruction Manual

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

MODEL 805 USER MANUAL

DIGITAL PANEL THERMOMETER

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Product Description. Contents. Fusion Series. New Information December 2003

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Hoist Controller for Direct Voltage Hoist Instruction Manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

User safety and equipment protection guidelines

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

PanelView Plus/VersaView CE Terminals and Display Modules

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT

INDICATOR FOR PROCESS CONTROL. Love Controls. LCI108J-0x INSTRUCTION MANUAL. EDITION: January Valid for models with software version P-1

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Hoist Controller for Low Voltage Hoist Instruction Manual

GUIDE PROGRAMMABLE PANEL METER M905

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Series M. M40-P. Meter for process signals. User s Manual. Tel. (+34)

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Hoist Controller for Low Voltage Hoist Instruction Manual

DST8-DIN 8-way DMX Splitter Instruction Manual

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

Thread length (overall length) material

Hoist Controller for Low Voltage Hoist

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Input Frequency: 650 range 50/60Hz 675 range Hz Input Ranges in Amps: Measurement Maximum Inrush

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

ACT-1B Series Panel Tachometer

V E1B Snap-in I/O Module

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

DIGITAL PANEL THERMOMETER

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

User's Guide. Model W 3-in-1 Switching DC Power Supply

Model HM-535 Power Supply Installation and Service Instructions

Vision OPLC V TR20/V350-J-TR20

Amplifiers, Counters, Timers & Controls

V E62B Snap-in I/O Module

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

V E5B Snap-in I/O Module

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Operating instructions. Switching amplifier DN0210 DN / / 2015

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

7511 / / / 711 / / 731 / Preset 27

DINALOG A 144 x 36 A1400 Light-Strip Indicator

signo 727 SSI operating instructions

Vision OPLC V TR6/V350-J-TR6

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Wireless Motor Controller Instruction Manual

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

V E2B Snap-in I/O Module

KEEP AWAY device from exposed to corrosive, volatile and flammable gases or liquids and DO NOT USE the device in similar hazardous locations.

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Operating instructions. Speed monitor D / / 2014

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

DST 4-way DMX/AC Power Splitter Instruction Manual

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

Installing the Tracer MP503 Input/Output Module Ordering number: ,

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Series 8000 RF Signal Switch Solution

Operation Manual Series W-500

E2Q4 Square Proximity Sensor

1-36V, 0-3A DC Power Supply

OPLC Installation Guide

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

EWCH 485 Electronic Pulse Counter

FLS M9.06. ph/orp MONITOR

FLOW MONITOR & TRANSMITTER

AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Wireless DMX Transmitter/Receiver/Splitt Instruction Manual

Manual Control Unit GFC 32

Supplementary operating instructions for your air curtain system Controller TMC 500

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Solid-state Timer H3YN

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Transcription:

COUNTERS for IMPULSES Series MAG983-X COUNTERS for IMPULSE signals FEMA ELECTRÓNICA MAG983-1 MAG983-2 MAG983-3 MAG983-4 IDEAL SOLUTION for impulse counting applications where the operator has no access to the configuration of the unit. Instruments with scaling capability, in order to visualize in different units such as units, meters, accumulated flow,... USER S MANUAL (HT0695-r050705) FEMA ELECTRÓNICA - Page 1

Series MAG983-X Impulse COUNTERS The MAG983-X is a series of impulse counters with 6 digits for panel mounting. The main input channel for impulse counting is defined as «INPUT1», and the additional input channel defined as «INPUT2» has a variable function depending on the model selected. All units can «RESET» from frontal push button and also from rearside terminal for mechanical contact. The reading of the instruments can be scaled activating scale factors, together with the position of the decimal point. By default, all units are configured as : 1 impulse = +1 Signal type NPN Without decimal points If a different configuration is needed, request your needs with the order, or see instructions on section 8 for self configuration. Model MAG983-1 Impulse counter with Inhibit Control «INPUT1» Input for impulses «INPUT2» Control for Inhibit Note.- «INPUT2» at negative logic, activates inhibit Model MAG983-3 Impulse counter with Add/Substract inputs «INPUT1» Impulses to ADD «INPUT2» Impulses to SUBSTRACT Model MAG983-2 Impulse counter with Add/Substract control «INPUT1» Input for impulses «INPUT2» Control for ADD/SUBSTRACT Note.- «INPUT2» at negative logic SUBSTRACTS Model MAG983-4 Impulse counter for Quadrature (Encoder) «INPUT1» Impulses from encoder CHANNEL-A «INPUT2» Impulses from encoder CHANNEL-B 0.- Ordering Reference MAG983 Model Power Signal Type Counting Relation Decimal Point 1 230 Vac NPN 1 imp = +1 xxxxxx 2 PNP 1 imp = +2.5 xxxxx.x 3 Namur 1 imp = +0.1 xxx.xxx 4 Pick-Up... Mechanical 1.- Technical Data DISPLAYS Led 7 segments red color SEGMENTS 9.9.9.9.9.9 DIGIT HEIGHT 14,2 mm. (0,56") POLARITY negative counting indicated by LED READING from 0 to 999999 DECIMAL POINT 6 positions, factory selected (or see section 8) INPUT SIGNAL PICK-UP Data RESET Vexc OUTPUT PNP,NPN,Namur,Contact, Pick-Up Jumper selectable maximum 28Vdc at input only on «INPUT1» Sensibility 150 mv peak Hysteresis 100 mv Impedance 26.5 Kohms at 60 Hz Maximum input voltage ±50 Vpp Contact at rearside terminals Frontal push button +10Vdc (maximum 70 ma) FREQUENCY MEMORY ON/OFF CYCLES DATA RETENTION maximum up to 10 KHz E 2 Prom non volatile 100.000 minimum 10 years minimum TRIGGER LEVELS Selectable (See section 4) «0» < 1.50 Vdc or «0» < 5.50 Vdc «1» > 3.75 Vdc or «1» < 7.50 Vdc POWER CONSUMPTION EXTERNAL FUSE 230 Vac (50 Hz) 3VA 50 ma at 230 Vac (not incluided) CONNECTIONS Plug-in screw clamps WIRE SECTION max. 2.5 mm2 (recommended1mm 2 ) WORKING TEMP. from 0 to +50 ºC STORAGE TEMP. from -40 to +70 ºC RELATIVE HUMIDITY 90 % a 40 C HOUSING DIN 43700 DIMENSIONS 96 x 48 x 117 mm (3,78 x1,89 x 4,61 ) PANEL CUTOUT 92,5 x 44,5 mm (3,64 x 1,75 ) MATERIAL HOUSING ABS, black color WEIGHT 310 gr. FEMA ELECTRÓNICA - Page 2

2.- Mechanical Dimensions (mm / inches) 13 (0,51) 5 max (0,20) 102 (4,02) 15 (0,59) 48 (1,89) 96 (3,78) Panel Cutout 92,5 x 44,5 (3,64 x 1.75) 3.- Front View The frontal of the MAG983 instruments shows the 6 displays for counting value, the led for negative sign polarity indication, and the «RESET» push button. This button can be disabled acting on jumper L (See section 4.3) Negative Sign LED RESET 4.- Internal Jumpers (Trigger Levels, Antirrebound Filters, Front Reset ): 4.1.- Trigger Levels for NPN, PNP, NAMUR signals Jumper H,G Closed Trigger Level LOW Logical «1» >3.75 Vdc Logical «0» <1.50 Vdc Jumpers H,G open Trigger Level HIGH Logical «1» >7.50 Vdc Logical «0» <5.50 Vdc J K G H 4.2.- Antirrebound Filters.- Jumpers J,K Closed.- Open.- Antirrebound filters at <100 Hz Antirrebound filters at <10KHz Jumper L Note.- Use filter <100Hz for input type mechanical contact, in order to filter contact rebounds 4.3. - Frontal Reset.- Jumper L Closed.- Enables front button for RESET 5.- Rear side view The rear side of the instrument shows the terminals for connecting signals, power of the instrument, and contact for «RESET», and the jumpers for signal type selection (Jumpers A,B,C,D,E,F) FEDCBA 2 1 6.- Power connections and Rearside Reset The «RESET» connection at the rearside terminal is operated with a mechanical contact connected at terminals 7 and 3. Power is connected at terminals 1 and 2. Connections for Connections for RESET POWER SUPPLY 2 1 RESET Reset + - Input2 Power Input1 Vexc (+10Vdc) Common + - ~ ~ FEMA ELECTRÓNICA - Page 3

7.1.- Sensor Type MECHANICAL CONTACT User s Manual - Series MAG983-X 7.- Connections for input signals and Signal Type selection Select Jumpers ADF «INPUT1» terminals 5 (Signal) and 3 (Common) «INPUT2» terminals 6 (Signal) and 3 (Common) Note -. close internal jumpers J,K. See section 4.2 MECHANICAL CONTACT at «INPUT1» MECHANICAL CONTACT at «INPUT2» 7.2.- Sensor Type NPN or PNP NPN.- PNP.- «INPUT1» «INPUT2» Jumpers ADF Jumpers ABCDF terminals 5 (Signal), 3 (Common) y 4 (Vexc) terminals 6 (Signal), 3 (Common) y 4 (Vexc) SENSOR NPN or PNP at «INPUT1» Signal +10 Vdc 0 Vdc SENSOR NPN or PNP at «INPUT2» 7.3.- Sensor Type NAMUR Select Jumpers BCDF «INPUT1» terminals 5 (Vexc), 4 (Signal) «INPUT2» terminals 6 (Vexc), 4 (Signal) SENSOR NAMUR at «INPUT1» Signal +10 Vdc 0 Vdc Signal +10 Vdc SENSOR NAMUR at «INPUT2» Señal +10 Vdc 7.4.- Sensor Type PICKUP Select Jumpers AE «INPUT1» terminals 5 (Signal) y 3 (Common) «INPUT2» terminals 6 (Signal) y 3 (Common) Note.- Input2 will be Mechanical Contact. It can not be configured for PICK-UP type SENSOR PICK-UP at «INPUT1» Señal 0 Vdc SENSOR PICK-UP at «INPUT2» FEMA ELECTRÓNICA - Page 4

8.- Introducing how to programm the instrument The MAG983 instruments do not have programming keypad accesible to the end user. To modify the configuration of the instrument, access the internal pins and configure the contacts indicated on «figure 1». These contacts will allow the activation of the required programming codes. Example.- To activate code «65 2E» (activation of decimal point at position XXXXX.X) close one after the other contacts «6», «5», «2» and «E» Contact 6 Number «6» appears on display 6 Contact 5 Number «5» appears on display 65 1 Together with code «65» appears also the number «1» indicating that code «65» already has a value of «1», this means, configuration without decimal point Contact 2 Number «2» replaces number «1» 65 2 Contact E The instrument activates the decimal point XXXX. XX Note.- the programming codes «1», «2» and «3», are composed of 1 digit only. When closing contact «3» the display will show a 5 digits number, which is the actual value of the «Scale Factor» (by default its value is «1.0000»). To modify each one of these 5 digits, close contacts «1» to «5» and once the desired value is on the display close «E» to validate. Common Contact +/- Contact 6 Contact 5 Contact 4 Contact 3 Contact 2 Contact 1 Contact E (ENTER) Figure1.- Connecting the programming contacts 9.- Reset of the Configuration and Default Parameters «41-1E» Reset of the instruments configuration. Activates the default parameters In order to place this code, close «4», «1», «1», «±» and «E» ± Select «±» to swtich between active instruments. MAG983 units have 2 internal instruments, a ratemeter and a counter. By default after the activation of a «41-1» code, the ratemeter remains activated. Close «±» to activate the counter Default Parameters «41 1E» Default Parameters «42 3E» Default Parameters «43 1E» «Input1» input, «Input2» inhibit control «44 1E» «Flanges multiplication» x1 «45 1E» «Multiplication Factor» x1 «46 1E» without Decimal Point «61 4E» Default Parameters «62 1E» Default Parameters «63 1E» Default Parameters «64 4E» Default Parameters «65 1E» Default Parameters «51 2E» «AL1» and «AL2» assigned to Counter «52 3E» Default Parameters «53» Default Parameters «54 3E» Default Parameters «55» Default Parameters «56 1E» Special functions. Normal Reset «66 1E» Default Parameters «1» 500 Value for memory «AL1» «2» 1000 Value for memory «AL2» «3» 1.0000 «Scale Factor» FEMA ELECTRÓNICA - Page 5

10.- Instrument Selection and Maximum Frequencies The Instrument Selection codes define if the instrument will work as impulse add, add/substract, etc, and it corresponds to the different units of MAG983 available. «INPUT1» «INPUT2» Max. Frequency Comments «43 1E» impulses control Inhibit 10 KHz Inhibits at logical state «0» «43 2E» impulses control Add/Substract 10 KHz Substracts at logical state «0» «43 3E» imp. Add imp. Substract 4.0 KHZ «43 4E» Does not apply ----------- «43 5E» Channel AB from bidirectional encoder 5.0 KHz Quadrature signal x1 «43 6E» Channel AB from bidirectional encoder 2.5 KHz Quadrature signal x4 11.- Programming the Multiplicators «3» «Scale Factor» is a multiplicator with a value between 0.0000 and 5.9999. By default is 1.0000 «45 1E» «Multiplication Factor» x1 Acts on the displayed value x0.1 «45 2E» «Multiplication Factor» x0,1 and shows counted impulses /10 «45 3E» «Multiplication Factor» x0,01 «45 4E» «Multiplication Factor» x0,001 «44 1E» «Multiplication Flanges» x1 (Counts at down flanges) «44 2E» «Multiplication Flanges» x2 (Counts at up flanges and down flanges) Note.- Not compatible with code «43 6E». Reduces maximum frequencies to the half 12.- Decimal Point Position «46 1E» 0 Note.- The same codes but with negative, allow «46 2E» 0.0 visualization of zeroes to the left. For example «46 3E» 0.00 code «46-2E» will show 00000.0 «46 4E» 0.000 «46 5E» 0.0000 13.- Specials Functions with the «RESET» and memories «AL1» and «AL2» «56 1E» When pressing «RESET» loads on display 000000 «56 2E» When pressing «RESET» loads on display the value of «AL2» and the impulses substract «56 3E» Does not apply «56 4E» Does not apply «56 5E» When pressing «RESET» loads on display 000000 and when «AL2» value is reached, display loads 000000 «56 6E» When pressing «RESET» loads on display the value of «AL2» and the impulses substract When reaching 000000 the value of «AL2» is loaded again and the impulses SUBSTRACT «1» Show the value of memory «AL1» «2» Show the value of memory «AL2» To modify the value of the memory «AL1» or «AL2, once loaded on display, use contacts 1,2,3,4,5,6 to modify the values of digits 1,2,3,4,5,6 and when the desired value is displayed close «E» to apply. ATTENTION - Límit on the Internal Counter The MAG983 instrument works with a 23 bits internal counter (maximum 8.388.608 impulsos can be counted). If this value is exceeded, the negative led sign is activated and the display will work in SUBSTRACT mode. Do a «RESET» of the display in order to recove functionality. Memory «AL2» can be also programmed to activate a «RESET» when its value is reached (see code «56 5E»). FEMA ELECTRÓNICA - Page 6

14.- Security Prescriptions INSTALLATION PRECAUTIONS.- The installation and use of this unit must be done by qualified operators. The unit has not power switch, and the unit has not internal protection fuse, and will start operation as soon as power is connected. The installation must incorporate an external main switch with a protection fuse of : fuse 50 ma (at 230 Vac power) Also the necessary devices to protect the operator and the process when using the unit to control a machine or process where injury to personnel or damage to equipment or process, may occur as a result of failure of the unit. SAFETY PRESCRIPTIONS.- The unit has been designed and tested under UNE 20553 rules and is delivered in good condition. This manual contains information for electrical connections. Do not make wiring signal changes or connections when power is applied to the unit. Make signal connections before power is applied and, is reconnection is required, disconnect the AC (mains) power before such wiring is attempted. Install the unit in places with a good ventilation to avoid the excessive heating. And far from electrical noise source or magnetic field generators such as power relays, electrical motors, speed controls etc... The unit cannot be installed in open places. Do not use until the installation is finished. POWER SUPPLY.- The power supply must be connected to the adequate terminals (see the connection instructions). The characteristics of the power supply are written on the attached label. Please make sure that the unit is correctly connected to a power supply of the correct voltage and frequency. Do not use other power supply otherwise permanent damage may be caused to the unit. Do not connect the unit to power sources heavily loaded or to circuits which power loads in cycle ON-OFF or circuits with power inductive loads. SIGNAL WIRING.- Certain considerations must be given when install the signal input and control wires. Long wires can act like antennas and introduce electrical noise to the unit, therefore : A.- Do not install the signal input or control wires in the same conduit with power lines, heaters, solenoids, SCR controls etc...and always far from these elements. B.- When shielded wires are used, connect the shield to the common terminal and leave unconnected the other end of the shield and do not connect to the machine ground. EXCITATION VOLTAGE.- The unit supplies excitation voltage for sensors, at terminals 3 and 4. Do not connect these terminals to external power supply, permanent damages may result to the unit. SAFETY CONSIDERATIONS.- Before starting any operation of adjustment, replacement, maintenance or repair, the unit must be disconnected from the power supply. Keep the unit clean, to assure good functioning and performance. To prevent electrical or fire hazard, do not expose the unit to excessive moisture. Do not operate the unit in the presence of flammable gases or fumes, such as environment constitutes a definite safety hazard. The unit is designed to be mounted in a metal panel. If the unit shows signs of damage, or is not able to show the expected measures, or has been stored in a bad conditions or a protection failure can occur, then do not attempt to operate and keep the unit out of service. IN CASE OF FIRE 1.- Disconnect the unit from the power supply. 2.- Give the alarm according to the local rules. 3.- Switch off all the air conditioning devices. 4.- Attack the fire with carbonic snow, do not use water in any case. WARNING : In closed areas do not use systems with vaporized liquids. CONNECTIONS All wiring connections are made using push-in cable connectors. There is a separate connector block for power supply, input signals and each relay output. Please make sure that each connector block is connected on the adequate place. PANEL MOUNTING.- The instrument size case is 1/8 DIN. The internal electronic circuit can be inserted or removed by the front part and is held on to the case by the two lateral lugs, which must be put in their corresponding holes placed on each case side. Verify that the panel cut-out is correctly according to the dimensions indicated with a minimum depth of 135 mm. (5.31"). Install the fixation clips of blue colour in the lateral guides of the unit by its rear part and then slide and press them firmly against the panel, until the unit is totally hold on. 15.- Declaration of Conformity DECLARATION OF CONFORMITY Manufacturer.- FEMA ELECTRÓNICA, S.A. Address.- Pol. Ind. Santiga - Altimira 14 (T14 - N2) E-08210 Barberà - BARCELONA ESPAÑA - SPAIN Conforming products Model.- MAG983-1, MAG983-2, MAG983-3, MAG983-4 DIRECTIVES EUROPEAN DIRECTIVE FOR LOW VOLTAGE D73/23/CEE AMENDED BY D93/ 68/CEE. Equipments powered from 50 to 1000 Vac. and / or from 75 to 1500 Vdc. ELECTROTECHNICAL REGULATION FOR LOW VOLTAGE (RBT) ITC21, ITC29, ITC35. Equipments with power supply lower than 50 Vac and/or 75 Vdc. We hereby declare that the above products conform to the essential protection requirements of Directives and Harmonised Standards stated below. Signed.- D. Juncà Position.- Quality Manager Place.- Barberà, 2005 EUROPEAN DIRECTIVE FOR ELECTROMAGNETIC COMPATIBILITY D89/ 336/CEE AMENDED BY D93/68/CEE STANDARDS IMMUNITY UNE EN 50082-1 (1998) EMISSIONS UNE EN 50081-1 (1994) ELECTRICAL SAFETY UNE EN 61010-1 (1996) UNE EN 60204-1 (1997) FEMA ELECTRÓNICA - Page 7

more products Programmable Panel Meters Signal Converters & Isolated Transmitters Large Displays Standard Panel Meters Miniature Panel Meters Large Displays for TIME www.fema.es ELECTRONIC INSTRUMENTATION FOR INDUSTRY FEMA ELECTRÓNICA, S.A. Pol. Ind. Santiga - Altimira 14 (T14 - N2) E-08210 Barberà - BARCELONA ESPAÑA - SPAIN Tel. (+34) 93.729.6004 - www.fema.es Fax (+34) 93.729.6003 - info@fema.es FEMA ELECTRÓNICA - Page 8