PRODUCT SHEET INTERFACE MODULES

Similar documents
Chapter 1 MP Systems. 5

BSL Hardware Guide for MP35 and MP30-1 -

PRODUCT SHEET. 40HP Monaural Headphones OUT01E Foam Ear Inserts: LED

PRODUCT SHEET. NON-INVASIVE SMALL ANIMAL TAIL BLOOD PRESSURE SYSTEMS NIBP250 Blood Pressure Amplifier NIBP200A Blood Pressure System

IX-228/S Data Acquisition Unit

Dept. of Electrical, Computer and Biomedical Engineering. Instrumentation for the data acquisition laboratory

Expert I/O 1000 Hardware User Manual

PRODUCT SHEET. ! OXY-MRI is not intended for animal use.

CONTROL PROTOCOL Motorized Projection Screens

IST ULTRASTAB Power Supply for high precision transducers

Tutorial - Introduction to LabScribe and the IX-ELVIS

iworx RA-834 Recorder

EDX-10 Series. Compact Recording System

Connecting a Cisco Input Module

PCI-FPGA-1B User Guide

eace PLC Velocio s Embedded Ace (eace) PLC

Features. High-precision Analog input board (Low Profile size) for PCI Express AI-1616L-LPE AI-1616L-LPE 1. Ver.1.01

EDX-10 Series. Compact Recording System

HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

DATENBLATT ADA16-8/2(LPCI)L. HABEN SIE FRAGEN ODER WÜNSCHEN SIE EIN INDIVIDUELLES ANGEBOT? Unser Team berät Sie gerne persönlich.

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

Connecting a Cisco Output Module

INSTRUCTION MANUAL. Dual-System Signal Interface

DCN23 Digital Crossover with 2 inputs and 3 outputs

Student Quick Reference Guide

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Adapter Kit - Remote QSI Electronics Installation Instructions

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

RibEye Multi-Point Deflection Measurement System 3-Axis Version for the SIDIIs ATD Hardware Manual for Model January 2010

AO-1604LX-USB. Features. High-Resolution Analog Output Unit for USB AO-1604LX-USB 1. Ver.1.01

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Ace PLCs. Velocio s Ace PLCs

Release Note. How to Use the OptoCon Connection Module. 1 Introduction. Option C Revision 4 Revised 8/13/98

M-5B-1/U (Type 20) List of Contents M-5B-1/U. 4 analog inputs, 1 analog output, 14 TTL outputs for connecting 5B transducers

Universal Keying Adapter 3+

AIO AH-PCI. Features. Packing List. 12-bits Analog I/O Board (High Gain) for PCI AIO AH-PCI 1. Ver.1.04

ADI12-16(PCI) Isolated Multi-Function Analog Input Board for PCI ADI12-16(PCI) 1. Ver.1.01

Installation Instructions for: Channel Thermocouple Amplifier

User instructions for CMS EE HV Distribution Crates. Draft Version 0.1 : 16 th July 2008

Model User Manual Revision E 04/29/99. OEM Gaging System. Part Number R01

TNG-3B derives its operating power from the serial port. The DTR, RTS, and both data lines are all used, and must be properly connected.

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

CONNECTING SENSORS TO DATA ACQUISITION SYSTEM ANALOG INPUTS

MedeaWiz 8X78. Input / Output Expander. FW version 1.0. PCB version 1.0. Manual version Note that this manual may change periodically

LGR-5325 Specifications

M ICROSTAR LABORATORIES TM

Features. High-Speed Analog Input Board for PCI AD12-16U(PCI)EH. High-Speed & Resolution Analog Input Board for PCI AD16-16U(PCI)EH

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Specifications USB-1408FS

Specifications PMD-1208FS

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

15 Discovery Way, Acton, MA Phone: (978) , Fax: (978) Web Site: Acton SpectraHub TM

Branch PLC. Velocio s Branch PLC

Limit switches Instrument sensors

Domain 3000 Back Panel

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.01

The Condor Expansion Kit

USB-1208LS Specifications

UHP-T-LED User Manual

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.01

PSM-2 POWER SUPPLY MODULE INSTRUCTIONS

ARDUINO LEONARDO WITH HEADERS Code: A000057

Custom O2+ODAC Soldering Instructions

Signal Connections CHAPTER

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.02

4Trio Motion Technology3

16-Channel 16-Bit Differential High-Speed PMC Analog Output Board

ARDUINO LEONARDO ETH Code: A000022

Click-A-Tune. User Manual

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.02

Specifications minilab 1008

GSV-1A4 M12/2 M12/2. Highlights

Vernier SensorDAQ User s Manual

HARDWARE OPERATIONS MANUAL

APPENDIX E: IWX3XX HARDWARE MANUAL

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

XT-9100 Technical Bulletin

Arduino Uno. Arduino Uno R3 Front. Arduino Uno R2 Front

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PedalSync. 9 Switches MV-62. Chip. Module. and

48-Bit Isolated Digital I/O

LGR-5327 Specifications

Specifications

GSV-3USBx2 3,5mV/V 4,2V

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

Analog Output Accessory Board Manual

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Product Manual MNX10043 REV A MODEL DSB. Dual Sensor Modular Switch box

MODEL 9250 Preliminary data sheet

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules

IT Designs Copyright All Rights Reserved. Mix-It, Mix-It2 and M logo are trademarks of IT Designs.

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

OMX-CI-RS232 Control Interface

Transcription:

INTERFACE MODULES HLTC UIMC When connecting the analog output sourcing from external devices to the MP or MP, channel contention must be considered. To connect external device outputs to the MP or MP: Non-human subjects or only collecting data from external devices If the MP System is only collecting signals from non-human subjects (via MP system amplifier modules) or if the MP System is only collecting data from external devices: o Connect external device output signal to an unused UIMC input channel (-) Human subjects If the MP System is collecting signals from human subjects (via MP system amplifier modules), it's important to isolate the external device output signal from the MP System input. o Connect external device output signal to an unused HLTC input channel (-) via INISO. Channel contention issues. If an analog channel is used on the UIMC or HLTC, make certain that two external devices do not use the same analog channel.. If amplifier modules are connected to the MP System then those amplifier modules must be set to a channel which is not used by external devices plugged into the UIMC or HLTC. For example: Two external device outputs are connected to the MP/ system. Device one is a Noninvasive Blood Pressure (NIBP) monitor and device two is an Electronic Scale. In addition, an ECGC module is attached to the MP/ System and is being used to measure the electrocardiogram. All devices are connected to a human subject. In this case, to fully isolate the human subject: Both the NIBP monitor and the Electronic scale outputs should be connected to the MP/ inputs via the HLTC, using one INISO for each input channel. The ECGC should be snapped directly to the MP/ System and connected directly to the subject with the appropriate leads and electrodes. Assuming the NIBP is connected via INISO to HLTC channel and the Electronic Scale is connected via INISO to HLTC channel, then the ECGC amplifier must be set to a channel between -. o The ECGC can t use Channels and because both of these channels are being used by other devices. If additional instruction or a special cable is required to connect the MP System to the device, please contact a Systems, Inc. applications engineer at. Hardware UIMC Page - Updated:..

UIMC UNIVERSAL INTERFACE MODULE The UIMC Universal Interface Module is the interface between the MP* and external devices. Typically, the UIMC is used to input pre-amplified signals (usually greater than +/. volt peak-peak) and/or digital signals to the MP acquisition unit. Other signals (e.g., those from electrodes or transducers) connect to various signal-conditioning modules. *The UIMC is for MP hardware only. For interfacing newer MP hardware, use the HLTC High Level Transducer Module. The Universal Interface Module (UIMC) is designed to serve as a general-purpose interface to most types of laboratory equipment. The UIMC consists of sixteen. mm mini-phone jack connectors for analog inputs, two. mm mini-phone jack connectors for analog outputs, and screw terminals for the digital lines, external trigger, and supply voltages. The UIMC is typically used alone to connect polygraph and chart recorder analog outputs to the MP System. Systems, Inc. offers a series of cables that permit the UIMC to connect directly to a number of standard analog signal connectors. Most chart recorders or polygraphs have analog signal outputs, which can be connected directly to the UIMC. The UIMC allows access to analog inputs and analog outputs on one side, and digital input/output lines, an external trigger, and supply voltages on the other side. The UIMC is designed to be compatible with a variety of different input devices, including the series of signal conditioning amplifiers (such as the ECGC). Connecting the UIMC to the MP System MP: Snap the UIMC onto the right side of the MP unit. When using the Universal Interface Module (UIMC) with other C-Series modules, the UIMC is usually the first module cascaded in the chain. If using the STMC, OXYC or HLTC, the module must be plugged in on the left of the UIMC. Up to seventeen modules (including the UIMC) can be snapped together, as illustrated in the following diagrams: Hardware UIMC Page - Updated:..

Analog connection cable (CBL,, or ) Systems 9 Chart recorder with phone jack, RCA jack, or BNC connector for analog output Typical UIMC to polygraph interface When using the UIMC, be careful not to short the analog output terminals together, and not to short across any of the connectors on the Digital (back) side of the module. IMPORTANT USAGE NOTE Mains powered external laboratory equipment should be connected to an MP System through signal isolators when the system also connects to electrodes attached to humans. To couple external equipment to an MP System, use: For analog signals INISO or OUTISO isolator (with HLTC) For digital signals STPC (with UIMC) Contact for details. ANALOG CONNECTIONS See also: Setup notes for external devices and channel contention issues. As noted, the UIMC requires cables equipped with standard.mm mini-phone plugs to connect to analog signal sources. This type of connector is commonly available with many different mating ends. Systems, Inc. carries several different types, including BNC and phone plugs. Since the MP/ analog inputs are single-ended, the tip of the mini-phone plug is the input and the base (shield) of the mini-phone plug is the ground (or common). NOTE: Make sure the cable that is routed into the UIMC is a mono. mm phone plug. To connect to existing equipment (such as polygraphs or chart recorders), run a cable from the analog output terminal of the external device to the UIMC. Since there are so many different devices that can connect to the MP/ it s impossible to cover them all. Hardware UIMC Page - Updated:..

Analog connection cable (CBL,, or ) Systems 9 Transducer or pre-amplified electrode DIGITAL CONNECTIONS UIMC connected to external analog signal source Systems Pushbutton switch Systems + - TTL digital source + V TRIG GND D + V TRIG GND D 9 9 + V GND A - V + V GND A - V Trigger connected to UIMC MP unit to digital source connection A digital signal has only two voltage levels: Volts = binary and + volts = binary. A positive edge is a to transition and a negative edge is a to transition. The MP digital I/O lines have internal pull-up resistors so that unconnected inputs read. This means that external passive switches can be used to introduce digital (ON/OFF) data into the UIMC by connecting the switch terminal between the digital I/O (-) and Ground (GND). In this configuration, the input will be read as. when the switch is closed and as + V when the switch is open. The digital input/output lines on the UIMC have screw terminals that can accept pin plugs or bare wires, as shown above. Be careful not to short the +, + V and V terminals together or to the GND A or GND D output terminal, or the MP may become damaged. The digital lines are divided into two blocks, I/O through and I/O through. Each block can be programmed as either inputs or outputs. Do not connect a digital input source to a block that is programmed as an output. Hardware UIMC Page - Updated:..

Output devices (such as leads or an LED) can be connected to the digital side of the UIMC. Outputs can be connected so that they are ON either when a signal output from the UIMC reads Volts or when a + V signal is being output. When connecting to an LED, be sure to use a current-limiting resistor (typically Ω) in series with the LED. To connect an LED so that it defaults to OFF (i.e., the digital I/O reads ), attach one lead of the output device to the GND D terminal on the UIMC and connect the other lead to one of the digital I/O lines (I/O, for example). When configured this way, the device will be OFF when I/O reads, and ON when I/O reads a digital (+ Volts). Alternatively, connect one of the device leads to the + V terminal on the UIMC and leave the other lead connected to the digital line (e.g., I/O ). With this setup, the device will be ON when the I/O line (in this case digital I/O ) reads, and OFF when the I/O reads a digital (+ Volts). UIMC SPECIFICATIONS Analog I/O: channels (front panel). mm phone jacks D/A Outputs: channels (front panel). mm phone jacks Digital I/O: channels (back panel) screw terminals External Trigger: channel (back panel) screw terminal Isolated Power: ± V, + V @ ma (back panel) screw terminals Weight: g Dimensions: cm (wide) x cm (deep) x 9 cm (high) Hardware UIMC Page - Updated:..