PG Softstarter Installation Manual for 5A, 9A and 16A Controllers

Similar documents
PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

Installation Instructions

Table of Contents. Safety. Attention. Warnings

Installation, Operation and Maintenance Manual

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

SMC FLEX QUICK START BULLETIN 150

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

78 Series Electromechanical Relay Selection Guide

AC Tech. Variable Speed AC Motor Drives. SCN Series Installation and Operation Manual

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

SMC -50 Fully Solid-State Smart Motor Controller

PACSystems RX3i and Series IC694MDL916 and IC693MDL916 Output Module, Isolated Relay, N.O., 4 Amp, 16 Point

Digital ac/dc (24V) Input Module

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

920 Remote Control (RC) Switches

SECTION VARIABLE FREQUENCY DRIVES

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

PART 1: GENERAL PART 2: PRODUCT. Effective: 12/29/10 Page 1 of 6 FECA-TE-104D

SP500 AC Drive Installation and Operation Manual Version 3.1

CI-tronic Soft start motor controller

INSTRUCTION MANUAL IM253 R0. AquaStart COMBINATION SOFT STARTERS START-UP MANUAL

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

E1 Plus Electronic Overload Relay

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

ASCO 920 Remote Control (RC) Switches

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

A drive dedicated to variable speed control for HVAC applications

MCCB-500 MOLDED-CASE CIRCUIT BREAKER TESTER

Section 4 Ground-Fault Protection Devices

Tempco Instruction Manual

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

Installation and Operation Manual D SP500 AC Drive. Version 3.1

Voltage Dip-Proofing Inverter

PanelView Plus/VersaView CE Terminals and Display Modules

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Voltage Dip-Proofing Inverter

********SERVICE MANUAL******** MODELS:

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

S66 Series Electronic Fan Speed Control

TeSys IEC Contactors and Overload Relays

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

VLT 2800 DRIVE SPECIFICATIONS

Operating Instructions. For. Level Control Module. Model SSR 1000

Specifications, Installation, and Operating Instructions

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

PGR-3200 MANUAL INSULATION MONITOR

PACSystems* RX3i and Series IC693MDL940 / IC694MDL940

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Easy To Use OEMS Take Note

Differential Liquid/Gas Pressure Transmitter

Table of Contents 1. Overview Installation...6

160 AA02SF1 AF DS-D17

User Manual. Allen-Bradley Automation. SMC Dialog Plus Controller. Bulletin 150

SED2 VFD NEMA Type 3R Bypass/Air Conditioner

MODBUS TCP MODULE INSTRUCTIONS. for use with WSIQ2/WSE

Section 0.0 Warnings... 3 Section 1.0 Quick Set-up... 4 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

AIR COOLED MODULAR RECTIFIER

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

ADVANCED MICRO SYSTEMS

User Guide Regenerative & Non-Regenerative Digital DC Drives 5 to 1000 HP

high RESISTANCE STOPLIGHT Instruction Manual C-101EM

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Voltage Sag Simulator

1. Warnings Introduction Mechanical Installation Electrical Installation Application Examples...

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

PowerFlex 40 Sample Specification

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

SP SP-T-9

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Section 0.0 Warnings... 2 Section 1.0 Quick Set-up... 3 Section 2.0 Description Section 3.0. Section 4.0. Section 5.0. Section 6.0. Section 7.

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Solar Combiner Enclosure

Bulletin 1489 Circuit Breakers. Selection Guide

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

MODELS DPDT DPDT DPDT-60MS DPDT-60MS

Supplement to Instruction Manual

Relay Contact Output Modules

CompactLogix Power Supplies Specifications

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

RT4F-120V/20A-WAC RECTIFIER

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

PRM MODEL TABLE. (1) Measured at 115V a-c source.

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SLC Expansion Units Catalog Nos EI01, -El02,-El03, -El04, - IUS,-El06, -E107

Transcription:

PG Softstarter Installation Manual for 5A, 9A and 16A Controllers Important User Information The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Sprecher + Schuh cannot assume responsibility or liability for actual use based on the examples and diagrams. In no event will Sprecher + Schuh be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. Reproduction of the contents of this manual, in whole or in part, without written permission of Sprecher + Schuh is prohibited. Precautionary Notes In this manual you will see the following types of precautionary statements: Bold type points out specific areas of concern that are critical to your understanding or use of the product. WARNINGS: tell you where people may be hurt if procedures are not followed properly. CAUTIONS: tell you where machinery may be damaged or economic loss can occur if procedures are not followed properly. Installation and Wiring... 3 Set-Up Procedures... 11 Troubleshooting... 19 1

Notes 2

Installation and Wiring Inspection Before installing the controller, make a complete visual check of the controller for damage in shipment or handling. Claims for damaged or missing parts must be made to the carrier as soon as possible after receipt of shipment. Enclosures Customer Installed NEMA 12 Enclosures The following are recommendations for installing the open-style device in an enclosure. When the open style device is installed in an enclosure, the internal temperature of the enclosure must be kept within the range of 0 C to 50 C. The following table shows the maximum heat dissipation at rated current for the controller. Figure 2.1 - Maximum Heat Dissipation PG Controller Current Rating 5A 9A 16A Maximum Watts 32 45 70 Mounting The controller is convection cooled. It is important to locate the controller in a position that allows free air flow vertically through the controller. The controller must be mounted with heatsink fins in a vertical plane for maximum cooling. See Figure 2.2. Figure 2.2 - Dimension Drawing Unit A B C D E F Approx. width height depth Ship Wt. 5A Millimeter 122 127 134 24 110 90 2kg Controller Inch 4-13/16 5 5-9/32 61/64 4-11/32 3-35/64 4.5lbs 9A Millimeter 122 180 134 24 110 140 2.25kg Controller Inch 4-13/16 7-3/32 5-9/32 61/64 4-11/32 5-33/64 5lbs 16A Millimeter 154 180 160 50 140 140 3.15kg Controller Inch 6-5/64 7-3/32 6-5/16 1-31/32 5-33/64 5-33/64 7lbs All dimensions and weights include the interface module. All dimensions and weights are approximate and are not to be used for construction purposes. Refer to nearest Sales Office or Corporate Headquarters at Houston, Texas for complete dimension drawings. 3

Wiring The controller wiring terminal locations are shown in Figure 2.4. Make wiring connections as indicated in the typical connection diagrams shown in Figures 2.5, 2.7, 2.8, 2.9 and 2.10. Connect the line to terminals L1/1, L2/3, and L3/5. Connect the load to terminals T1/2, T2/4, and T3/6. A provision is available for grounding the isolated heatsink per applicable codes. Use Figure 2.3 as a guide for wiring: Figure 2.3 - Power & Control Wire Size and Tightening Torque Wire Size Torque Metric 1.5-6mm 2 1.36 N-m AWG 14-12 AWG 12 LB-IN Figure 2.4 - Power Wiring Terminal Locations 1 3 5 L1 L2 L3 T1 T2 T3 2 4 6 Series Controller Mode This design requires an electromechanical starter on the line side of the unit. The controller requires no control voltage input. See Figure 2.5. Figure 2.5 - Series Controller Mode 4

Description of Interface Module The PG controller is designed to be operated by an external device. An optional interface module is inserted into the PG controller that enhances the capabilities of the controller. This module can be field or factory installed and offers the following features: Provides ON/OFF control directly to the controller through an external device. In many applications the interface module may eliminate the need for an additional contactor if electrical isolation or soft stop is not required. This reduces the required panel space. Provides a selectable auxiliary contact that operates as either an instantaneous or upto-speed contact making it available for a wide variety of control schemes. Provides a Soft Stop feature that extends stopping time to minimize load shifting or spillage during stopping. Wiring with Interface Module Control power requirement for interface module is 5VA at 120V and 15VA at 240V. Auxiliary contact rating is NEMA C300, 2.5 Amps, 20-250VAC; 1 Amp, 12-30VDC. Figure 2.7 - Typical Connection Diagram 5

Programmable Controller and Sensor Interface When using solid-state devices to operate the PG controller with interface module, the ON-state voltage range and frequency will be 100-120V, 50/60 HZ, if the 120 volt interface module is used. The ON-state voltage and frequency range will be 200-240V, 50/60 Hz, for the 240 volt interface module. The OFF-state leakage current from the solid-state device must be less than 5mA. The nominal input current is 25mA at 120 VAC and 50mA at 240VAC. Figure 2.8 - Typical Connection with 2-Wire Control Scheme Isolation Contactor An isolation contactor is used to provide electrical isolation of the controller and motor circuit when the controller is shut down by either manually pressing the stop button, or automatically by the occurrence of abnormal conditions. WARNING: When not using an isolation contactor, hazardous voltages are present at the load terminals of the controller even when the controller is turned off. Warning labels must be attached to the motor terminal boots, the controller enclosures, and the control station. Additional circuitry must be included to provide automatic isolation. If Soft Stop is required, wire per Figure 2.9. If wired per Figures 2.7 or 2.8 and an overload occurs while an isolation contactor is not used, the PG controller will continue to soft stop the motor. 6

Figure 2.9 - Typical Connection with Soft Start, Soft Stop and Isolation Contactor Figure 2.10 - Typical Connection with Two-Wire Control Scheme for Soft Start and Soft Stop 7

Power Factor Capacitors The controller can be installed on a system with power factor correction capacitors. The capacitors must be located on the line side of the controller. This must be done to prevent damage to the SCRs in the PG controller. Fast Acting Current-Limiting Fuses Fast acting current limiting fuses are coordinated with the SCRs for protection of the SCRs in the event of short circuits in the load. Refer to Figures 2.11 for recommended fast acting current limiting fuses. Figure 2.11 - Fast Acting Current-Limiting Fuses Fuse PG Controller Rating Manufacturer PGS-005 PGS-009 PGS-016 Shawmut A70P12 A70P20 A70P40 Buss FWP15 FWP20 FWP40 Brush XL70F015 XL70F020 XL70F040 NOTES: 1. Fuse numbers are fuse manufacturer s catalog number. 2. Fuse size listed is for 230, 460 or 575 volt. CAUTION: The fast acting current-limiting fuses specified in the above table do not provide branch circuit protection. Branch circuit protection in accordance with applicable electrical codes is required even though fast acting current-limiting fuses are used. Motor Overload Protection Thermal motor overload protection is not provided unless specified with the open style or non-combination controller. It can be separately provided. The overload trip time should be greater than the acceleration time to avoid nuisance tripping. CAUTION: Overload relays should be properly coordinated with the motor. Protective Module (optional) A protective module containing metal oxide varistors (MOVs) and snubbers can be installed to protect the power components from electrical transients and/or high electrical noise. The protective modules clip transients generated on the lines and prevent such surges from damaging the SCRs. The snubbers in the protective modules are used to shunt noise energy away from the controller electronics. There are two general situations that can occur which would indicate the need for utilizing the protective modules. 1. Transient spikes can occur on the lines feeding the controller (or feeding the load from the controller). Lightning can cause these spikes. These spikes are also created on the lines when devices are attached to the same lines with current carrying inductances that are then open-circuited. The energy stored in the magnetic field is released when the contacts open the circuit. Examples of these are lightly loaded motors, transformers, solenoids, and electromechanical brakes. 2. The second situation arises when the controller is installed on a system which has fastrising wavefronts present, although not necessarily high peak voltages. Lightning strikes can cause this type of response. Additionally, if the controller is on the same bus as AC/DC drives, induction heating equipment and welding equipment, the firing of the SCRs in those devices can cause noise. This high frequency noise can penetrate the controller through stray capacitance always present in real systems. WARNING: When installing or inspecting the protective module, make sure the controller has been disconnected from the power source. The protective module must be checked periodically for damage. Inspect for damage or discoloration. Replace if necessary. 8

Single-Speed, Reversing Starters (Series Controller Mode) By using the controller as shown in Figure 2.12, the motor accelerates under a controlled start mode in either direction. NOTE: Minimum transition time for reversing is 1/2 second. Figure 2.12 - Typical Application with a Single Speed, Reversing Starter Two-Speed, Two- Winding, Non- Reversing Starters (Series Controller Mode) By using the controller in this fashion, the motor accelerates in a controlled manner when in Low or High speed. The isolation contactor is used to provide automatic isolation from the power source. Recommendations for an isolation contactor are detailed on page 6. Figure 2.13 - Typical Application with a Two-Speed Motor Starter 9

Notes 10

Set-Up Procedures Start and Stop Sequences Without Interface Module The PG controller, without the optional interface module, is designed to operate as a series controller. (Refer to Figure 2.5 on page 4). It is wired between an electromechanical starter and the motor. When the starter is energized, three-phase power is delivered to the line side of the PG controller. This causes it to automatically go through the start sequence. No control inputs are required. Without the interface module, all that is required to stop the PG controller is to remove three-phase power from the line side of the unit. This is accomplished by de-energizing the electromechanical starter. With Interface Module When the PG controller has the interface module installed, the controller operates using 3-wire control. See Figure 3.1 below. Figure 3.1 - Typical Connection Diagram when Interface Module is Used In this mode, the controller can operate with or without an electromechanical contactor. The unit is operated by pressing the start button. The internal hold-in circuit latches across terminals 20 and 30, and the auxiliary contact changes state (if so selected on the DIP switches). The controller then goes through the selected start sequence. WARNING: Disconnect main power before servicing motor controller or associated wiring. HAZARDOUS voltages are present in the motor circuit even when the solid-state controller is off. With the interface module, there are two methods of stopping: normal coast-to-stop and Soft Stop. To use coast-to-stop, the Soft Stop DIP switches (1 and 2) must be turned off. Simply pressing the stop button initiates stop. Soft Stopping requires that the unit be preset: the Soft Stop DIP switches (1 and 2) must be in the ON position, and the appropriate DIP switches must be set for the time required for stopping. 11

Overload Trips When an overload trip occurs, the normally closed contact (wired into terminal 40) opens, causing the controller logic to shut off immediately. Fault Trips There is a single red LED on the front of the PG controller for diagnostic indication. When three-phase power is applied to the controller, the LED will be on. The PG controller monitors the following fault conditions: Shorted SCR (pre-start only) Phase Loss (line side and pre-start only) Stalled Motor (when stall switch is on) If a shorted SCR or phase loss exists, the PG controller will not start and the LED will flash. If a stalled motor condition exists, the controller shuts down and flashes the LED. In the event three-phase input power is lost, the LED turns off. Stalled Motor The controller is designed to sense motor stall in both the Starting and Running modes. If during the Starting cycle, the controller senses that the motor is stalled and if the motor remains stalled, the controller shuts down in a predetermined time based on the selected ramp time. In the Running mode, the controller trips in 4 seconds in the event of a locked rotor condition. The LED flashes in either case. Starting stall trip times are illustrated in Figure 3.2. Figure 3.2 - Starting Stall Trip Characteristics Start Times (sec.) Maximum Stall Trip Times (sec.) Soft Start Current Limit Full Voltage from Start - - 1/10 4 2 - - 6 5 - - 9 10 - - 14 20 - - 24 25 - - 29 30 - - 34-15 - 19-30 - 34 Energy Saver This is a built-in feature with the PG controller. It is used to save energy on applications where the motor is lightly loaded or unloaded for long periods of time. 12

Factory Settings The controller has been factory set for the following parameters (refer to Figure 3.3): 10 Second Soft Start Energy Saver OFF Stall feature OFF Initial Torque 30% 60 Hz Full Voltage OFF Current Limit OFF Auxiliary Contact OFF Soft Stop OFF Figure 3.3 - Factory Switch Settings Initial Torque Level Time Select Mode Select 5 4 6 3 7 2 8 1 0 9 NO 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Full Voltage Start Current Limit Energy Saver Select 50/60 Hz Auxiliary Contact (Up-to-Speed/Instant) ON Position Stall Select Soft Stop Select Must be OFF when Soft Stop not used Soft Stop Select Must be OFF when Soft Stop not used NO Customer Settings After the controller has been installed, further set-up may be necessary. This set-up is accomplished through DIP and rotary digital switches located on the front of the controller. If the factory settings are not suitable for the specific application, pages 14 through 18 describe how to set the unit for Soft Start, Current Limit and Full Voltage Starting. WARNING: Disconnect power before opening access door and making adjustments to DIP and rotary digital switches. Use a small screwdriver to pry open the access door. Set the switches to meet application requirements. 13

Soft Start This method has the most general application. The motor voltage gradually increases during the acceleration ramp period, which can be adjusted from 2 to 30 seconds nominal. The controller is shipped with the acceleration ramp time set for 10 seconds. Therefore, in most cases, resetting the controller is not required. Soft Start Selection 1. Set Initial Torque rotary digital switch to the desired setting. Refer to next page. 2. Adjust DIP switches 13, 14 and 15 for soft start time. Refer to the next page for settings. 3. Set Energy Save DIP switch 7 to ON for energy savings. Set Stall DIP switch 3 to ON for stall protection. 4. Soft Stop is only available with the interface module. Set Soft Stop Select DIP switches 1 and 2 to ON for soft stop. Set DIP switches 10, 11, and 12 for stopping time. Refer to next page for settings. 5. Auxiliary contact is only available with the interface module. Set mode of the auxiliary contact with DIP switch 5. Set to OFF for instantaneous, ON for up-to-speed. 6. Switch 4 should be ON. 7. Switches 8 and 9 should be OFF. 8. Set switch 6 for line frequency (ON for 50 Hz, OFF for 60 Hz). 14

Soft Start Selection (continued) Initial Torque Level Time Select Mode Select 5 4 6 3 7 2 8 1 0 9 NO 15 14 13 12 11 10 NOTE: The switches shown above are for a 10 second Soft Start with a 30% initial torque and 25 seconds soft stop. 9 8 7 6 5 4 3 2 1 Full Voltage Start Current Limit Energy Saver Select 50/60 Hz Auxiliary Contact (Up-to-Speed/Instant) ON Position Stall Select Soft Stop Select Must be OFF when Soft Stop not used Soft Stop Select Must be OFF when Soft Stop not used Initial Torque Level NO Rotary Position 0 1 2 3 4 5 6 7 8 9 % of Locked Rotor Torque 0 1 2 5 10 20 30 40 50 70 Soft Start Time Switch Time (seconds) Number 2 5 10 15 20 25 30 15 Off ON Off ON Off ON Off 14 Off Off ON ON Off Off ON 13 Off Off Off Off ON ON ON Soft Stop (Available only with Switch Time (seconds) Number 5 10 15 25 35 45 55 110 12 Off ON Off ON Off ON Off ON 11 Off Off ON ON Off Off ON ON 10 Off Off Off Off ON ON ON ON 15

Current Limit This starting mode is used when it is necessary to limit the maximum starting current. The current limit is adjusted according to starting current restrictions. This can be adjusted from 25 to 550% of full load amperes nominal. Current Limit Selection 1. DIP switch 8 must be ON for current limit mode. Refer to next page. 2. Set rotary digital switch for current limit level. Refer to next page for settings. 3. Set switches 13, 14 and 15 for current limit start time. 4. Set Energy Saver DIP switch 7 to ON for energy savings. Set Stall DIP switch 3 to ON for stall protection. 5. Soft Stop is only available with the interface module. Set Soft Stop Select DIP switches 1 and 2 to ON for soft stop. Set DIP switches 10, 11 and 12 for stopping time. Refer to next page for settings. 6. Auxiliary contact is only available with the interface module. Set mode of the auxiliary contact with DIP switch 5. Set to OFF for instantaneous, ON for up-to-speed. 7. Switch 4 should be ON. 8. Switch 9 should be OFF. 9. Set switch 6 for line frequency (ON for 50 Hz, OFF for 60 Hz). 16

Current Limit Selection (continued) Current Limit Level Time Select Mode Select 5 4 6 3 7 2 8 1 0 9 NO 15 14 13 12 11 10 NOTE: The switches shown above are for a 15 second 300% current limit start. 9 8 7 6 5 4 3 2 1 Full Voltage Start Current Limit Energy Saver Select 50/60 Hz Auxiliary Contact (Up-to-Speed/Instant) ON Position Stall Select Soft Stop Select Must be OFF when Soft Stop not used Soft Stop Select Must be OFF when Soft Stop not used NO Rotary Position - % Current Limit Position 0 1 2 3 4 5 6 7 8 9 % of Full Load Amps 25 50 100 200 250 300 350 450 500 550 Current Limit Start Time Switch Time (seconds) Number 15 30 15 Off ON 14 Off Off 13 Off Off Soft Stop (Available only with Switch Time (seconds) Number 5 10 15 25 35 45 55 110 12 Off ON Off ON Off ON Off ON 11 Off Off ON ON Off Off ON ON 10 Off Off Off Off ON ON ON ON 17

Full Voltage For applications requiring a full voltage start, the acceleration ramp time is set to minimum (1/10 second). This, in effect, allows the controller to start the load across-theline. Full Voltage Selection 1. For full voltage starting, switch 9 must be ON and switches 13, 14 and 15 must be OFF. This results in a full voltage start of approximately 1/10 second. 2. Set Energy Saver DIP switch 7 to ON for energy savings. Set Stall DIP switch 3 to ON for stall protection. 3. Soft Stop is only available with the interface module. Set Soft Stop Select DIP switches 1 and 2 to ON for soft stop. Set DIP switches 10, 11, and 12 for stopping time. Refer to chart below for settings. 4. Auxiliary contact is only available with the interface module. Set mode of auxiliary contact with DIP switch 5. Set to OFF for instantaneous, ON for up-to-speed. 5. Switch 4 should be ON. 6. Switch 8 should be OFF. 7. Set switch 6 for line frequency (ON for 50 Hz, OFF for 60 Hz). Current Limit Level Time Select Mode Select 5 4 6 3 7 2 8 1 0 9 NO Soft Stop (Available only with Switch Time (seconds) Number 5 10 15 25 35 45 55 110 12 Off ON Off ON Off ON Off ON 11 Off Off ON ON Off Off ON ON 10 Off Off Off Off ON ON ON ON 15 14 13 12 11 10 NO 9 8 7 6 5 4 3 2 1 Full Voltage Start Current Limit Energy Saver Select 50/60 Hz Auxiliary Contact (Up-to-Speed/Instant) ON Position Stall Select Soft Stop Select Must be OFF when Soft Stop not used Soft Stop Select Must be OFF when Soft Stop not used 18

Troubleshooting For safety of maintenance personnel as well as others who might be exposed to electrical hazards associated with maintenance activities, the safety related work practices of NFPA 70E, Part II, should always be followed when working on electrical equipment. Maintenance personnel must be trained in the safety practices, procedures, and requirements that pertain to their respective job assignments. WARNING: To avoid shock hazard, disconnect main power before working on the controller, motor, or control devices such as Start/Stop pushbuttons. CAUTION: Disconnect the controller from the motor before measuring insulation resistance (IR) of the motor windings. Voltages used for insulation resistance testing can cause failure to SCRs. Do not make any measurements on the controller with an IR tester (megger). NOTE: The time it takes for the motor to come up to speed may be less than the Start Time setting and will vary depending on the frictional load and inertial characteristics of the system. Motor Will Not Start - Series Controller Configuration (Figure 2.5 on Page 4) Symptom Possible Cause Remedy LED off No three-phase power Check three-phase line voltage Failed overload Check overload relay LED on DIP switch 2 on Turn DIP switch 2 off LED flashing Fault condition exists Check that all three-phase voltages are present. Check resistance between L1 & T1, L2 & T2 and L3 & T3. Less than 50 Ohms indicates shorted SCR. Replace unit. Motor stall Motor Attempts To Start - Series Controller Configuration Symptom Possible Cause Remedy Motor does not accelerate to full speed Motor overload Check motor load Motor stall Check if LED is flashing and DIP switch 8 is on. If so, motor stalled. Initial torque too low Adjust initial torque Motor Will Not Start With Interface Module (Figure 2.7 on Page 5) Symptom Possible Cause Remedy LED off No three-phase power Check three-phase line voltage Failed overload Check overload relay Interface module Check for control voltage requires control voltage LED on Tripped overload Check overload relay No control voltage Check control voltage between terminals 10 and 40 No start signal Check that start signal is present from 50 to 40 LED flashing Fault condition exists Check that all three-phase voltages are present. Check resistance between L1 & T1, L2 & T2 and L3 & T3. Less than 50 Ohms indicates shorted SCR. Replace unit. Motor stall Motor Attempts To Start With Interface Module Symptom Possible Cause Remedy Motor does not accel to full speed Motor overload Check motor load Motor stall Check if LED is flashing and DIP switch 8 is on. If so, motor stalled. Initial torque too low Adjust initial torque Auxiliary contact will not pick up Auxiliary contact not Check terminals 50/60 for proper operation working Replace interface module 19

Rely on Sprecher + Schuh for Quality and Innovation Power Devices: Motor Protection: Logic Circuit Products: Operator Interfaces: Contactors Motor Starters Solid State Starters Motor Circuit Controllers Custom Starter Panels Panel Mounting Systems Thermal Overload Relays Solid State Overload Relays Electronic Motor Protection Relays Thermistor Protection Relays Control Relays Timing Relays Terminal Blocks Pushbuttons Pilot Devices Rotary Cam Switches Disconnect Switches Sprecher + Schuh has been helping customers increase production and improve quality for more than 90 years. Today, Sprecher + Schuh is part of the Rockwell Automation family of companies, a world leader in industrial automation. As part of this group, we develop, manufacture and market a comprehensive range of control and automation products worldwide. Worldwide representation Sprecher + Schuh US Division Headquarters: 15910 International Plaza Drive, Houston, TX 77032 Tel: (281) 847-2000; Fax: (800) 739-7370 Sprecher + Schuh Canadian Division: 3610 Nashua Drive, Unit 10, Mississauga, Ontario L4V 1L2. Tel: (905) 677-7514; Fax: (905) 677-7663 Publication No: Tech-PG5 8.97 20