The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to

Similar documents
MODEL 8000MP LEVEL SENSOR

VE-53 Sensor Uniaxial / Triaxial Surface and Downhole Velocity Sensor. Operation Manual

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Flo-Ware. Discovering. Model 260/268 Flo-Tote System Manual. Version 3.1. Instrument & Data Management System for Windows 95,98 & NT

Marsh -McBirney, Inc.

AC-43 Accelerometer. User Manual

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

The information in this chapter will enable you to:

AG3000 SERIES FLANGED MAGMETER

Hydrostatic filling level sensor HFB C4 / R / MD

imag 4700 Series FLANGED MAGMETER

T E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable

Copy Machine Reader. Installation and Setup Guide

AG3000 SERIES FLANGED MAGMETER

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

60 Ghz - Radar filling level sensor RFM 2000 C4 / R / MD

Description. Specifications and Ordering Information 9200, 74712, Seismoprobe Velocity Transducer System

MAG. ECO FLO imag Series NSF FEATURES

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

T E M P O S O N I C S I I I INSTALLATION

SENC 150 REFERENCE MANUAL

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Power/RS 485 Comm. Ultrapure Water

Industrial Wet/Wet Differential Pressure Transducer

Portable Dual Frequency Doppler Flowmeter

Table of Contents. Table of Contents

Vibrating Wire Joint Meter Manual

Piccolo2-OEM Fiber-optic Version (Item nr. PICO2-OEM)

ECL150/ECL150e. Eddy-Current Displacement Sensor INSTRUCTION MANUAL. Measurement Systems from LION PRECISION

imag 4700 Series FLANGED MAGMETER

Users Manual Ocean Sensor Systems Wave Staff III

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

imag-series Flanged Magmeter

Installation and Operating Manual FM50 IOM 2-18 DRAFT

INSTALLATION INSTRUCTIONS

the Interactive Catalog

Level Measurement Continuous level measurement - Ultrasonic transmitters

Rack Installation Instructions

Quick Start Guide MC-III TM Flow Analyzer

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

IN-LINE. vpinstruments.com

Digital Keypad Introduction

Wall Thickness Monitor

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

MobileView Junction Box

2D Horizontal Profiler khz

DESIGN SPECIFICATION # R1 Model AHRS-500 P/N ARINC 407 TO ARINC 429 ADAPTOR CTRL # /17/96

Adapter Kit - Remote QSI Electronics Installation Instructions

APS4 Inductive Proximity Sensors

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

SM150. Quick Start Guide Version 1. Soil Moisture Sensor. Delta-T Devices Ltd

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Remote Water Level Monitoring Technical Note Product: HOBO RX3000 Station

Operation The MICROSONIC sensors are continuous-wave devices that consist of an ultra-high-frequency

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

VM 6.1. Capacitive Air Gap Measuring Chains User s Manual P/N: M7A-110

Stackable with all of Tucker Technologies Integra Suite Logging tools 1

Level Measurement Continuous level measurement - Ultrasonic transmitters

Ultrasonic Flow Meter Brochure

-C5RS-LC RS232 EXTENDER

DirectCommand Installation RoGator Model Year Ag Leader Technology

BTU 4 & Sensors. Installation and Operation Manual

Ultrasonic Analog Output Sensors

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Conductivity Transmitters

Computer Temperature Interface model CTI-2. Description. Installation. Control Module

E4PA. Ultrasonic Displacement Sensor. Ordering Information

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Synchronous Serial Interface (SSI) Output

DCT7088 Portable Digital Correlation Transit Time Flowmeter

POSICHRON PCQA Mounting Sets

LL-100. Technical datasheet. Non-contact level measurement sensor. Level, distance & position measurement of solids.

Engineering Note: EN0047 Commissioning a Hydro-Probe with a Command Alkon EZCal Station

Contents. Volume 8 Sensing Solutions CA E April

NL-01 NL-01. The NL-01 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

analytical bulk flow distance FLOW level pressure temperature industrial communication

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

MS-7000: SuperStar Reader

Raven Adapter Harness

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

TOXALERT MODEL AIR 2000

AI-102. IR Illuminator. Installation Guide. Rev IP Surveillance

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

LPG STM 94442A User s Manual

OPERATING INSTRUCTIONS

955 ebrik INSTALLATION MANUAL. Series ebrik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS LINEAR DISPLACEMENT TRANSDUCERS

MS-5000: MiniStar Reader

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

Temperature sensors TTM series. Miniature transmitters

9200, Seismoprobe

Version 1.4 June 2018

Heavy Duty Vibration Meter

Description, continued

ToughSonic Distance Sensors

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

Transcription:

Chapter 5 Model 464-BC Monitor Operation The Model 464-BC Monitor controls and stores flow data from Marsh- McBirney Flo-Dar sensors. A portable computer and Flo-Ware software is used to setup the flowmeter for the particular site and can also serve as a powerful data retrieval and reporting system. The three programmable 4-20 ma outputs provide a convenient way to transfer real time flow data to SCADA and other data collection systems, control systems and display devices. 36

Chapter 5, Portable Monitor Operation RS232 Version/Wiring Diagram MODEL 464-BC MONITOR DC POWERED FLO-DAR (RS232 VERSION) Enclosure: Polystyrene with cover 7.0H x 9.0W x 4.0D DATA LOGGER PCB NOTES: -Not to Scale -Subject to Change -All items on this drawing supplied by MMI except as noted -The connector that attaches to the Flo-Dar sensor is 1.2 diameter. Bulkhead Connectors Mating Cable Connectors Air Ref. Port and Filter Enclosure Mounting Holes RS232 COMM. 18 ft DB9S Connector 3 ft +12 VDC INPUT (Customer Supplied Power) 4-20mA Output 30 ft or FLO-DAR SENSOR CONNECTOR 37

Connecting the Monitor Sensor Connection Power Connections Connect the sensor cable to the sensor connector located monitor housing. If the sensor end of the cable is not already connected to the sensor it should be connected now. See Page 37 for instructions on connecting the sensor cables at the sensor end. The Model 464-BC comes with a 3 ft. power cable. The red wire is +12 VDC. The black wire is the power common. A longer customer supplied cable can be substituted if desired. Power Connector Hook-Up (6 Pin Bendix) +12 VDC in A Red N/C B N/C C Power Common D Black N/C E 4-20 ma Output Connector The Model 464-BC comes with a 10 ft. 4 to 20 ma output cable. A longer customer supplied cable can be substituted if desired. Output Connector Hook-Up (15 Pin Bendix) 4 to 20 ma #3 (+) C Blue 4 to 20 ma #3 (-) D Brown 4 to 20 ma #2 (+) E Black 4 to 20 ma #2 (-) F White 4 to 20 ma #1 (+) G Red 4 to 20 ma #1 (-) H Green Pins A-B and K-R are not used. 38

Desiccant Cartridge The Model 464-BC monitor should be mounted in a relatively dry environment such as a control room or other suitable space. A hydrophobic filter is attached to the APR port and should be all that is required in most applications. If the monitor is installed in a high moisture environment such as a pit, make sure a fresh desiccant cartridge is attached to the atmospheric pressure reference (APR) port located on the bottom of the Model 464- BC housing. Leave the filter in place and attach the desiccant cartridge to the filter. The desiccant cartridge protects the APR tube from moisture and debris effecting the accuracy of the surcharge level pressure transducer. Whenever a desiccant cartridge turns mostly pink, it should be replaced with a fresh (blue) cartridge. If desired, two cartridges may be used in series for long lasting protection. Desiccant cartridges Part #55032 may be purchased from Marsh-McBirney, Inc. 39

RS-232 Serial Communications Cable A portable computer with Flo-Ware software installed must be connected via a communication cable to the Model 464-BC to set up and collect data from the flowmeter. The communication cable is part of the Flo-Ware software package. Extra cables may be purchased by registered Flo-Ware users. The RS-232 Serial Communications Connector is located on the bottom of the Model 464-BC housing. The protective cover should remain in place whenever the communication cable is not connected. The Flo-Dar communication cable P/N 131013101 is different from the communication cable used for Flo- Tote flowmeters. 40

Setting Up the Model 464-BC for Your Site Note: The Flo-Ware T-200 Software with Flo-Dar File Driver is Required to Set-Up the Model 464-BC Flowmeter T-200 software with the Flo-Dar file driver is used to configure your Model 464-BC to a particular metering site, scale the 4-20 ma outputs, transfer stored data from the flowmeter to your computer system, view the operation of your meter in real time, and to run reports and graphs based on the collected data. Detailed instructions for using Flo-Ware T-200 software are contained in the Discovering Flo-Ware Flo-Dar System Manual. This manual covers operation of the Model 460 and 464-BC monitors. The 4-20 ma output setup instructions are found in the extended setup section. Instructions are also accessed directly from the T-200 program via the Help function. The sensor offset and site specific information such as pipe shape, pipe ID and sediment level obtained during sensor installation will need to be entered into the site set-up section of T-200 Flo-Dar communications. Securing the Monitor 1 #10 or #8 screws or bolts may be used to secure the monitor to a flat surface. Drill a 6 by 8 inch (153 x 203 mm) hole pattern where the monitor is to be mounted. 2 Pull up and turn to remove the four cover screws from the cover of the monitor. Note the cover is sealed and should be left in place. 3 Insert the mounting screws or bolts through the four holes at the corners of the monitor and secure the monitor to the flat surface. 4 Re-install the cover screws. 41

Specifications Sensor Enclosure Material: Polystyrene Dimensions: 6.9" W x 16.65" L x 11.7" D (17.5 cm x 42.3 cm x 29.7 cm) Weight: 10.5 lbs. Temperature Operating Range: -32 F to 122 F (-35 C to 50 C) Storage Range: -40 F to 140 F (-40 C to 60 C) Sensor Cable Material: Polyurethane jacketed Standard Length: 30 feet (9.14m), maximum 500 feet (152.4 m). Both the sensor and the monitor have IP68 waterproof connectors for easy disconnection. Velocity Measurement Method: Radar Range: 0.75 to 20 ft/s (0.23 m/s to 6.10 m/s) Accuracy: ±0.5%; ±0.1 ft/s (±0.03 m/s) Level Measurement Method: Ultrasonic Operating Range: 0.25 to 60 in. (0.634 to 152.4 cm) Temperature Compensated Accuracy: ±0.25 in. (±0.64 cm) 1% Accuracy Surcharge Level Measurement Method: Piezo-resistive pressure transducer Maximum Range: 138 inches (3.5 meters) Flow Measurement Based on Continuity Equation. Accuracy: ±5.0% of reading typical where flow is in a channel with uniform flow conditions and is not surcharged. Monitor Data Storage 64K (16K cycles of velocity/level data) Local Terminal RS232C at 19.2K baud 4-20 ma Outputs (3) fully programmable, isolated outputs capable of driving 650Ω each. Power Requirements +12 VDC @ 220 ma with all three 4-20mA outputs @ 20mA Housing Material: Polystyrene (IP66-7/IP67-7) Heigth: 7 (188 mm) Width: 9 (229 mm) Depth: 4 (102 mm) Weight: 2.75 lbs. (1.25 kg) Temperature Operating Temperature Range: 32 F to 122 F (0 C to 50 C) Storage Temperature Range: -4 F to 122 F (-20 C to 50 C) Setup/Data Retrieval Flo-Ware for Windows software (sold separately) is the instrument setup and report generation software for the Model 464-BC. It is compatible with computers (desktop and portable) utilizing Windows 95/98/NT. Flo-Ware for Windows software can retrieve data from both Flo-Tote and Flo-Dar Flowmeters. Sensor/Logger Disconnect Both the sensor and the logger have waterproof (IP68) connectors for easy separation from the interconnecting cable. Certification FCC Rules Part 15; Industry Canada RS 210 (No user license required.) 46