Vision OPLC V TR20

Similar documents
Vision OPLC V TR20/V350-J-TR20

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Vision OPLC V TR20

Vision OPLC. V T38 Installation Guide. General Description

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

This guide provides basic information for Unitronics controller model V T2.

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

Vision OPLC V TR6/V350-J-TR6

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

OPLC Installation Guide

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

The identified danger could cause physical and property damage.

Vision OPLC. General Description. Installation Guide V T34.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

Failure to comply with appropriate safety guidelines can cause severe injury or property damage.

Vision OPLC. General Description.

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

Installation Guide V1210-T20BJ This guide provides basic information for Unitronics controllers V1210-T20BJ.

UniStream HMI Panel. CPU-for-Panel

This guide provides basic information for Unitronics controllers V C30B and V T40B.

EX-RC1 Remote I/O Adapter

V TU24 V350-J-TU24

High Speed Remote I/O Module

V E5B Snap-in I/O Module

V E62B Snap-in I/O Module

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

UniStream CPU-for-Panel

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes* Yes* Yes* USB device, mini-b Com Ports, separate order, user-installed

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

EX-RC1 Remote I/O Adapter

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Component identification

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

IO-DI16, IO-DI16-L I/O Expansion Modules

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

High Speed Remote I/O Module

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

Micro-OPLC Installation Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

UniStream. Built-in. Installation Guide: US7-B5-B1, US7-B10-B1, US7-B5-TR22, US7-B10-TR22, US7-B5-T24, US7-B10-T24

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

User safety and equipment protection guidelines

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

V E1B Snap-in I/O Module

V E2B Snap-in I/O Module

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Unitronics Devices and RS485 Table Of Contents

Vision OPLC. Technical Specifications. V T34 Technical Specifications

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

V E3XB Snap-in I/O Module

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

V E1B Snap-in I/O Module

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

V E2B Snap-in I/O Module

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Vision OPLC. V TR6 Technical Specifications. Technical Specifications.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

V E3XBW Snap-in I/O Module

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

V350-RA22 V350J-RA22.

V E6B Snap-in I/O Module

V E3XB Snap-in I/O Module

V E4XB Snap-in I/O Module

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

IO-LC1, IO-LC3 I/O Expansion Modules 1-3 Loadcell Inputs, 1 Digital In, 2 Out

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

Using your PC to access a remote M90 via GSM

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1 npn inputs

350 TM. Features: V350-J Flat Panel. V350 Classic Panel HMI PLC. Communication

Power Supply Input voltage 20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

20.4VDC to 28.8VDC with less than 10% ripple Max. current consumption See Note 1

350 TM. Features: V350-J Flat Panel. V350 Classic Panel HMI PLC. Communication

V350-T38 V350J-T38.

Vision OPLC. Distributed by: M.A. Selmon Company, Inc 4 Oxford Rd. Milford, CT V R34/V350-J-R34 Technical Specifications

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

V430J-TR34 V350-TR34 V350J-TR34. pnp inputs

Samba OPLC SM35-J-T20

All Analog Outputs, voltage/current 10mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Micro800 Programmable Controllers

FX1N-2EYT-BD Output Expansion Board

Jazz-J. Jazz. Features:

Jazz-J. Jazz. Features:

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs

Item SM35-J-T20 SM43-J-T20 SM70-J-T20

FX1N-4EX-BD Input Expansion Board

Smart Portal SP5000SERIES

SNAP PAC Redundancy Option Kit

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Transcription:

Vision OPLC V130-33-TR20 Installation Guide The Unitronics V130-33-TR20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, and 3 HSC/Shaft-encoder Inputs 6 Relay Outputs 2 high-speed npn Transistor Outputs General Description V130 OPLCs are micro-oplcs, rugged programmable logic controllers that comprise: On-board I/O configuration Built-in operating panel containing a 2.4 screen and a keypad Communications 1 built-in serial port: RS232/RS485 Optional: the user may order and install one or both of the following modules: - RS232/RS485/Ethernet - CANbus Communication Function Blocks include: SMS, GPRS, MODBUS serial/ip. Protocol FB enables PLC to communicate with almost any external device, via serial or Ethernet communications I/O Options Information Mode Programming Software, & Utilities V130 supports digital, high-speed, analog, weight and temperature measurement I/Os via: On-board I/O configuration Model-dependent I/O Expansion Modules Local or remote I/Os may be added via expansion port or CANbus. This mode enables you to: View & Edit operand values, COM port settings, RTC and screen contrast/brightness settings Stop, initialize, and reset the PLC To enter Information Mode, press the <i> button for several seconds. The Unitronics Setup CD contains VisiLogic software and other utilities. VisiLogic Easily configure hardware and write both HMI and Ladder control applications; the Function Block library simplifies complex tasks such as PID. Write your application, and then download it to the controller via the programming cable included in the kit. Utilities Includes UniOPC server, Remote Access for remote programming and diagnostics, and DataXport for run-time data logging. To learn how to use and program the controller, as well as use utilities such as Remote Access, refer to the VisiLogic Help system. Unitronics 1

V130-33-TR20 Installation Guide Removable Memory Storage Micro SD card: store datalogs, Alarms, Trends, Data Tables; export to Excel; backup Ladder, HMI & OS and use this data to clone PLCs. For more data, refer to the SD topics in the VisiLogic Help system. Data Tables Data tables enable you to set recipe parameters and create datalogs. Additional product documentation is in the Technical Library, located at www.unitronics.com, and on the Unitronics Setup CD. Technical support is available at the site, and from support@unitronics.com. Standard Kit Contents Vision controller I/O connectors (x2) Battery (installed) Programming cable + RS232 adapter Mounting brackets (x2) Rubber seal Unitronics Setup CD Danger Symbols When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Danger The identified danger causes physical and property damage. Warning The identified danger could cause physical and property damage. Caution Caution Use caution. Before using this product, the user must read and understand this document. All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product according to local and national standards and regulations. Only qualified service personnel should open this device or carry out repairs. Failure to comply with appropriate safety guidelines can cause severe injury or property damage. Do not attempt to use this device with parameters that exceed permissible levels. To avoid damaging the system, do not connect/disconnect the device when power is on. Environmental Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration, in accordance with the standards given in the product s technical specification sheet. Ventilation: 10mm space required between controller s top/bottom edges & enclosure walls. Do not place in water or let water leak onto the unit. Do not allow debris to fall inside the unit during installation. Install at maximum distance from high-voltage cables and power equipment. 2 Unitronics

Vision OPLC Mounting Dimensions Panel Mounting Before you begin, note that the mounting panel cannot be more than 5 mm thick. 1. Make a panel cut-out measuring 92x92 mm (3.622 x3.622 ). 2. Slide the controller into the cut-out, ensuring that the rubber seal is in place. 3. Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right. 4. Tighten the bracket screws against the panel. Hold the bracket securely against the unit while tightening the screw. 5. When properly mounted, the controller is squarely situated in the panel cut-out as shown in the figure to the right. Unitronics 3

V130-33-TR20 Installation Guide DIN-rail Mounting 1. Snap the controller onto the DIN rail as shown in the figure to the right. 2. When properly mounted, the controller is squarely situated on the DIN-rail as shown in the figure to the right. Wiring Caution Do not touch live wires. Install an external circuit breaker. Guard against short-circuiting in external wiring. Use appropriate circuit protection devices. Unused pins should not be connected. Ignoring this directive may damage the device. Double-check all wiring before turning on the power supply. To avoid damaging the wire, do not exceed a maximum torque of 0.5 N m (5 kgf cm). Do not use tin, solder, or any substance on stripped wire that might cause the wire strand to break. Install at maximum distance from high-voltage cables and power equipment. Wiring Procedure Use crimp terminals for wiring; use 26-12 AWG wire (0.13 mm 2 3.31 mm 2 ): 1. Strip the wire to a length of 7±0.5mm (0.250 0.300 inches). 2. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure a proper connection. 4. Tighten enough to keep the wire from pulling free. Input or output cables should not be run through the same multi-core cable or share the same wire. Allow for voltage drop and noise interference with input lines used over an extended distance. Use wire that is properly sized for the load. The controller and I/O signals must be connected to the same 0V signal. Connect cable shields to the system earth ground using the shortest and thickest possible wire. 4 Unitronics

Vision OPLC I/Os This model comprises a total of 12 inputs 6 relay and 2 npn outputs. Input functionality can be adapted as follows: 1. 12 inputs may be used as digital inputs. They may be wired in a group via a single jumper as either npn or pnp. According to jumper settings and appropriate wiring: - Inputs 10 and 11 can function as either digital or analog inputs. - Inputs 0, 2, and 4 can function as high-speed counters, as part of a shaft-encoder, or as normal digital inputs. - Inputs 1, 3, and 5 can function as either counter reset, as part of a shaft-encoder, or as normal digital inputs. - If inputs 0, 2, 4 are set as high-speed counters (without reset), inputs 1, 3, 5 can function as normal digital inputs. Input Jumper Settings The tables below show how to set a specific jumper to change input functionality. To access the I/O jumpers, you must open the controller according to the instructions beginning on page 9. Incompatible jumper settings and wiring connections may seriously damage the controller. Digital Inputs 0-11: Set Type Set to JP1 (all Inputs) npn (sink) A pnp (source)* B Inputs 10/11: Set as Digital or Analog Set to JP5 (Input 10) JP6 (Input 11) Digital* A A Analog B B Analog Inputs AN0/AN1: Set Type Set to JP3 (AN0) JP4 (AN1) Voltage* A A Current B B *Default settings Unitronics 5

V130-33-TR20 Installation Guide I/O Wiring I/O Configuration npn Input Wiring Input wiring npn (sink) HSC input wiring, npn (sink) pnp Input Wiring Input wiring pnp (source) HSC input wiring, pnp (source) 6 Unitronics

Vision OPLC Shaft-encoder Analog Input Wiring Analog input wiring, current/voltage (4-wire) Analog input wiring, current (2/3 wire) Shields should be connected at the signal s source. The 0V signal of the analog input must be connected to the controller s 0V. Relay Outputs Increasing Contact Life Span To increase the life span of the relay output contacts and protect the device from potential damage by reverse EMF, connect: A clamping diode in parallel with each inductive DC load An RC snubber circuit in parallel with each inductive AC load Unitronics 7

V130-33-TR20 Installation Guide npn Outputs Power Supply The controller requires an external 24VDC power supply. The power supply must include double insulation. Outputs must be rated as SELV/PELV/Class 2/Limited Power. Use separate wires to connect the functional earth line (pin 3) and the 0V line (pin 2) to the system earth ground. Install an external circuit breaker. Guard against shortcircuiting in external wiring. Double-check all wiring before turning on the power supply. Do not connect either the Neutral or Line signal of the 110/220VAC to device s 0V pin. In the event of voltage fluctuations or non-conformity to voltage power supply specifications, connect the device to a regulated power supply. Earthing the OPLC To maximize system performance, avoid electromagnetic interference by: Mounting the controller on a metal panel. Connect each common and ground connection directly to the earth ground of your system. For ground wiring use the shortest and thickest possible wire. Communication Port Caution Turn off power before making communications connections. Signals are related to the controller s 0V; the same 0V is used by the power supply. Always use the appropriate port adapters. The serial port is not isolated. If the controller is used with a non-isolated external device, avoid ground potential difference that exceeds ± 10V. Port 1 is type RJ-11 and may be set to either RS232 or RS485 via jumper as shown below. By factory default, the port is set to RS232, termination ON. Use RS232 to download programs from a PC, and to communicate with serial devices and applications, such as SCADA. Use RS485 to create a multi-drop network containing up to 32 devices. 8 Unitronics

Vision OPLC Pinouts The pinouts below show the PLC port signals. To connect a PC to a port that is set to RS485, remove the RS485 connector, and connect the PC to the PLC via the programming cable. Note that this is possible only if flow control signals are not used (which is the standard case). RS232 RS485** Controller Port Pin # Description Pin # Description 1* DTR signal 1 A signal (+) 2 0V reference 2 (RS232 signal) 3 TXD signal 3 (RS232 signal) 4 RXD signal 4 (RS232 signal) Pin #1 5 0V reference 5 (RS232 signal) 6* DSR signal 6 B signal (-) *Standard programming cables do not provide connection points for pins 1 and 6. **When a port is adapted to RS485, Pin 1 (DTR) is used for signal A, and Pin 6 (DSR) signal is used for signal B. RS232 to RS485 Jumper Settings The figure to the right shows the jumper factory default settings, RS232, RS485 termination ON. Note that in order: To change the communication setting to RS485, both communication standard jumpers must be moved. To change the RS485 termination, both termination jumpers must be moved. To access the jumpers, you must open the controller according to the instructions below. Opening the Controller Before performing these actions, touch a grounded object to discharge any electrostatic charge. Avoid touching the PCB board directly. Hold the PCB board by its connectors. 1. Turn off the power supply, disconnect, and dismount the controller. 2. The back cover of the controller comprises 4 screws, located in the corners. Remove the screws, and pull off the back cover. Unitronics 9

V130-33-TR20 Installation Guide Changing I/O settings 1. The I/O board of the controller is now exposed, enabling you to change I/O settings according to the jumpers shown on page 5. Changing Communication Settings 1. To access the communication jumpers, locate the screw close to COM port 1, and remove it. 2. Hold the I/O PCB board by its top and bottom connectors and steadily pull the board off. 3. Locate the jumpers, and then change the settings as required. Jumper settings are shown on page 9. Closing the Controller 1. Gently replace the board. Make certain that the pins fit correctly into their matching receptacle. Do not force the board into place; doing so may damage the controller. 2. Replace the back cover of the controller and fasten the corner screws. Note: You must replace the back cover securely before powering up the controller. Helsinki tel. +358 9 540 4940 automation@klinkmann.fi St. Petersburg tel. +7 812 327 3752 klinkmann@klinkmann.spb.ru Moscow tel. +7 495 641 1616 moscow@klinkmann.spb.ru Yekaterinburg tel. +7 343 287 19 19 yekaterinburg@klinkmann.spb.ru Samara tel. +7 846 273 95 85 samara@klinkmann.spb.ru Кiev tel. +38 044 495 33 40 klinkmann@klinkmann.kiev.ua Riga tel. +371 6738 1617 klinkmann@klinkmann.lv Vilnius tel. +370 5 215 1646 post@klinkmann.lt Tallinn tel. +372 668 4500 klinkmann.est@klinkmann.ee Мinsk tel. +375 17 200 0876 minsk@klinkmann.com