CP 64 BD15 CP 64 PD15

Similar documents
COLOR PAR 56 COLOR PAR 64. User Manual Please read the instructions carefully before use. Широкий ассортимент оборудования ACME на

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

MATRIX LED LED User Manual Please read the instructions carefully before use

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

LED W RGBA User Manual

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

User Manual Please read the instructions carefully before use

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

imove 50SR LED-MS50A User Guide Professional Entertainment Technology

FLEX BEAM V8. User Manual Please read the instruction carefully before use

User Guide. Please read these instructions carefully before use

Широкий ассортимент оборудования ACME на User Guide. Professional Entertainment Technology

TB-1230 QW. User Manual Please read the instruc on carefully before use

LED BEAM MOVING HEAD FL x3W User Manual

User Guide. Innovation, Quality, Performance. Широкий ассортимент оборудования ACME на Professional Entertainment Technology

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

User Guide Professional Entertainment Technology

Ostar Eye K18. Beam and Kaleido Effects. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

Spider Light. User Manual. Model: LM80. Big Dipper Laser Science And Technology Co., Ltd REV;1.01. Please read this manual carefully before operating

COB100/200W 2in1/3in1 led Par Light

MATRIX 25E. Matrix Beam Wash, ArtNet, RDM. User manual. Please read the instructions carefully before use

User Guide Please read these instructions carefully before use

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

X-3 LED. Owner s Manual ROBOHEAD

i.shine 3148 RGBW Color Stainer XP USER MANUAL

i.shine 1136 RGBW Color Stainer CN USER MANUAL

DM-X Channel DMX Controller. Item ref: UK User Manual. Version 2.0

xbrick Full-Colour 16 3W LED floodlight user manual

LED SPIDER MOVING HEAD LIGHT

w w w. p r o l i g h t. c o. u k STAGE PAR 64

Cobra Dimmer Master DMX Controller User Manual

User Guide Please read these instructions carefully before use

RGB Power Batten. User Manual. Order code: EQLED032

StagePar COB TRI 4 CKU

Robot Light V2. User Manual

LIGHT BRICK - 12 X 3W TRI-COLOUR

Microbar COB System. User Manual. Order code: EQLED137

User Guide Please read these instructions carefully before use

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Blitzer RGB Strobe. User Manual. Order code: EQLED365

User Guide Please read these instructions carefully before use

User Manual INTRODUCTION SAFETY INFORMATION BACK PANEL DIAGRAM. Please read the instructions carefully and before use.

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

LED BEAM MOVING HEAD 12x12W Cree, 4in1, beam 8 degree

Springtree Spatial Wash COB RGBW

FOS Pixel Video Panel. User Manual

User Instructions. American DJ Charter Street Los Angeles Ca

LED PAR56 Order Code: P56-151

Blitzer Strobe. User Manual. Order code: EQLED366

Outdoor Stage PAR 12 3W Tri LED-PAR. user manual

Robocolor II System. users guide

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

Blue Weapon Laser. User manual UK. Version 1.0

Performer 18 RGBWA MKII

Spectrum Laser. User manual UK. Version 1.0

SP-1500 DMX MK II Strobe

TourPro RGBAW Stagebar USER MANUAL

Snapshot. Data Stream 4 USER MANUAL

User Instructions. American DJ

Colour Burst Order code: LEDJ01 USER MANUAL

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Owner s Manual. DJ Lase 150-RGY MKII

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Crossfire. User Manual. Order code: EQLED061

Snapshot. User Manual. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120/230 V switch Replaceable Fuse User-Serviceable

Professional DMX Stage Backdrop

Order code: EQLED53 User manual

Gobo Projector XP 80W

LED DANCING FLOOR User Manual

MICRON DJ Booth Tri-colour Starcloth

Saturn Spot. User Manual. Order code: EQLED023

LEDBAR1812 Outdoor 1m LED Bar 18 x 12W 6-in-1 RGB LEDs User s instruction manual

Order code: EQLED60 USER MANUAL

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

UV Power Flood. User Manual. Order code: EQLED029

Vector Beam White. User Manual. Order code: LEDJ265

User Manual for: Professional DJ Multi Beam LED Seashell Stage Effect Light with DMX. MODEL: LG8xSEA

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 7

DMX LED Starcloth Systems

1. BEFORE YOU BEGIN INTRODUCTION SETUP... 6

36LEDs Par Light. User Manual

RGBW PAR CANS. Item ref: SL-FC3, SL-36, SL-64, SL-SW, SL-Q8, SL-Q12 User Manual. Errors and omissions excepted. Copyright AVSL Group Ltd.

MH-100 Beam 36x3 LED moving head. user manual

GLX LED STAGE 4 MANUAL GLS-4 LED STAGE 4. owners manual

Endura 1Q120 RGBW COB Exterior Fixture

order code: EQLED40 user manual

LED Stage Par Light DMX wireless&battery 10-watt x 4 LEDs (R/G/B/A/W 5IN1) User s Manual

Transcription:

COLOR PAR 64 CP 64 BD15 CP 64 PD15 User Manual Please read the instruction carefully before use

Contents 1. Safety Instruction...2 2. Technical Specification...3 3. Installation...4 4. DMX Address Setting...4 A. DMX address setting by dip switches...5 B. Automatic DMX addressing...5 C. Remote DMX address setting by CA T DMX TESTER...6 D. Remote DMX address setting by Universal DMX controller...6 5. How to control the fixture...7 A. Universal DMX controller...7 B. Master/Slave operation...8 C. Easy Controller (By CA 8)...8 6. DMX 512 Connections...9 7. Troubleshooting...10 8. Fixture Cleaning...11 1A

1. Safety Instruction WARNING Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Unpack and check carefully there is no transportation damage before using the unit. Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit. It s important to ground the yellow/green conductor to earth in order to avoid electric shock. Disconnect mains power before maintenance or servicing. Use safety cable when fixes this unit. Don t handle the fixture by taking its head only, but always taking its base. Maximum ambient temperature TA: 40. Don t operate it when the temperature is higher. In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repair carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center and always use the same type spare parts. Do not connect the device to any dimmer pack. Do not touch any wire during operation as high voltage might be causing electric shock. The housing must be replaced if they are visibly damaged. Do not look directly at the LED light beam while the fixture is on. The unit is for indoor use only and use only in a dry location. The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked. There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact your nearest dealer. Please read the instruction carefully which including important information about the installation, operation and maintenance. 2A

2. Technical Specification Input Voltage: AC 120V~60Hz or AC 230/240/250V~50Hz Power consumption: 28 W LED: 212pcs Red 70pcs, Green 71pcs, Blue 71psc Channels: Channel 1 = Red Channel 2 = Green Channel 3 = Blue Channel 4 = Dimmer/Sound Chase/Strobe Dimension: 216 x 216 x 205mm Weight: 3kg Beam Angel: 15 Luminous intensity: 3A

3. Installation Please check out the voltage before applying power. Do not connect the fixture to an electrical dimmer system which could damage the inside electronics. 4. DMX Address Setting Each fixture needs to have an address set to receive the data sent by the controller. The address number is between 0~511 (usually 0&1 are equal to 1). The address, also know as the start channel, is the first channel used to receive instructions the controller. There are four ways to set the fixture DMX start address: A. DMX address setting by dip switches B. Automatic DMX addressing C. Remote DMX address setting by CA T DMX TESTER D. Remote DMX address setting by universal DMX controller If you use the function B, C or D to set the DMX start address, the fixtures of the chain all DIP switch MUST be set to OFF. 4A

A. DMX address setting by dip switches 1. Select the channels of DMX controller 2. Dipswitches Dip # 1 # 2 # 3 # 4 # 5 # 6 # 7 # 8 # 9 # 10 Value 1 2 4 8 16 32 64 128 256 No function Example: Channel 01: dip/on: #1 (=1) Channel 05: dip/on: #1, #3 (1+4=5) Channel 09: dip/on: #1, #4 (1+8=9) Channel 13: dip/on: #1, #3, #4 (1+4+8=13) B. Automatic DMX addressing 1 The DMX address of fixture can be set automatically. You have to press the auto addressing button from the first fixture s main PC Board. When you hold the button 5secs, the fixture will be set the DMX address to 1, and the other fixtures of the chain will be set their own DMX address automatically. 2. The fixture used four channels, the next fixture s will be automatic calculate their own DMX address, no need to calculate the DMX channels of each fixture in the chain. (Fixture 1 =1, Fixture 2 = 5, Fixture 3 = 9, Fixture 4 =13, Fixture ) 3. No need to turn the fixture off when you change the DMX address, as new DMX address setting will be affected at once. Every time you turn the fixture on, it will be ready to receive DMX signal or turn the built in programs. 5A

C. Remote DMX address setting by CA T DMX TESTER The fixture can be set the DMX address remotely by CA T DMX TESTER. Please refer to the CA T user manual to set the DMX address to the fixture. D. Remote DMX address setting by Universal DMX controller 1. Make sure the DMX cable of all units are connected. 2. Connect the first unit to a universal DMX controller. 3. Connect all units to the mains so they are switched on. 4. Set all DMX channels on your DMX controller to zero (value 000). 5. Set all DMX channels, that you want to assign as DMX start address on your projector, tot maximum (value 255). 6. Press the Auto DMX address button on the projector shortly. 7. If you want to set another projector to the same DMX start address. Simply press it s Auto DMX address, button and it will receive the same address. 8. Done! An example to make things clear: 1. We will set the DMX start address of a projector to 106. 2. Connect the projector to the DMX controller as described above and make sure all is switched on. 3. Set all DMX channels on the controller to zero (000). 6A

4. Now set SMX channel 106 to maximum (255). 5. Press the Auto DMX address button on the projector shortly. 6. Done! Your projector now has DMX address 106! 5. How to control the fixture Three ways to set up the DMX address: A. Universal DMX controller B. Master/Slave operation C. Easy controller(by CA 8) A. Universal DMX controller The fixture can be set the DMX address remotely by universal DMX controller. First, you need to programming two scenes into a chase, and then link the fixtures to the universal DMX controller. When you run the chase, all the fixture of the chain will be set the series DMX address automatically. If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pin adapter. The fixture uses four channels. Please refer the following diagram to use your controller to activate the fixture. 7A

B. Master/Slave operation The fixtures will allow you to link 16 fixtures together and operate without a controller. In Master/Slave mode, the first fixture will control the others to give an automatic, sound activated, synchronized light show. This function is good when you want an instant show. The first unit it s DMX input cable will have nothing connect it, and the other fixtures will be set in slave mode automatically. Their DMX input cables connect the last fixture DMX output cable (daisy chain). Any fixture can act as a master or as a slave. C. Easy Controller (By CA 8) The easy remote control is used only in master/slave mode. There is a terminator for connect the easy controller inside the fixture. By connecting the cable into DMX IN waterproof cable gland to the CA 8terminator of the first fixture, you will find that the remote control on the first fixture will control all the other units for Stand by, Function and Mode. Built in lighting shows triggered by Easy Controller: Stand by Blackout the fixture 9 Color select Color Chase Color Fade White 1.The same 1. Fast speed Red color 2. Middle speed Function Strobe 1. Synchronous Strobe in white color 2. The same color chase 3. Different color strobe Blue Purple Orange Green Yellow 2.Different color 3.One light chase 4.Two lights 3. Slow speed Magenta chase Cyan 5. Four lights chase Mode Sound 1(LED OFF) Manual (LED ON) Sound 2 (LED slow blinking) Auto (LED fast blinking) 8A

6. DMX 512 Connections The DMX 512 is widely used in intelligent lightings and with a maximum of 512 channels. 1. Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the next unit. The cable can not be branched or split to a Y cable. DMX 512 is a very high speed signal. Inadequate or damaged cables, solder joints or corroded connectors can easily distort the signal and shut down the system. 2. The DMX output and input connectors are pass through to maintain the DMX circuit, when power is connected to the unit. 3. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W resistor between pin 2(DMX ) and pin 3(DMX+) into a 3 pin XLR plug and plug it in the DMX output of the last unit. 4. Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0 511 (usually 0 & 1 are equal to 1). 5. 3 pin XLR connectors are more popular than 5 pin XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal ( ), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal ( ), Pin 3: Positive signal (+) 9A

7. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A. The unit does not work, no light and the fan does not work 1. Check the connection of power and main fuse. 2. Measure the mains voltage on the main connector. B. Not responding to DMX controller 1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity. 3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one. 4. Try to use another DMX controller. 5. Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit. C. Some units don t respond to the easy controller 1. You may have a break in the DMX cabling. Check the LED for the response of the master/ slave mode signal. 2. Wrong DMX address in the unit. Set the proper address. D. No response to the sound 1. Make sure the unit does not receive DMX signal. 2. Check microphone to see if it is good by tapping the microphone E. One of the channels is not working well 1. The stepper motor might be damaged or the cable connected to the PCB is broken. 2. The motor s drive IC on the PCB might be out of condition 10A

8. Fixture Cleaning The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics. Clean with soft cloth using normal glass cleaning fluid. Always dry the parts carefully. Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days. 11A

Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 2004/108/EC. EN55103-1: 2009 ; EN55103-2: 2009; EN61000-3-2: 2006 + A1:2009 + A2:2009; EN61000-3-3: 2008. & Harmonized Standard EN 60598-1:2008 + All:2009; EN 60598-2-17:1989 + A2:1991; EN 62471:2008; EN 62493: 2010 Safety of household and similar electrical appliances Part 1: General requirements

Innovation, Quality, Performance