readme.txt README.TXT

Similar documents
Series Controller_Readme_8_2010.txt README.TXT

readme.txt README.TXT

readme.txt README.TXT

Series-6-Controller_Readme_3_2011.txt

README.TXT

README.TXT

readme.txt README.TXT

readme.txt README.TXT

README.TXT

This is the official software release containing the list of software components listed in the section 3 of the release note.

README.TXT

This is the official software release containing the list of software components listed in the section 3 of the release note.

ASM_readme_6_50_18771.txt README.TXT Adaptec Storage Manager (ASM) as of


This is the official software release containing the list of software components listed in the section 3 of the release note.

This is the official software release containing the list of software components listed in the section 3 of the release note.

README.TXT

README.TXT

Adaptec ASR-7805/ASR-7805Q/ASR-71605/ASR-71605Q/ASR-71605E/ASR-71685/ASR SAS/SATA RAID Controllers

Forces a physical drive offline. The drive enters the Failed state. Available in the Physical Device group on the maxview ribbon.

This is the official software release containing the list of software components listed in the section 3 of the release note.

3ware Release Notes Supporting 9690SA and 9650SE controllers

SuperTrak EX4650 / 8650 / 8654 / 8658 / SAS and SATA Controller Release Notes

Release Notes for (Supporting 3ware 9690SA and 9650SE controllers)

This is the official software release containing the list of software components listed in the section 3 of the release note.

This is the official software release containing the list of software components listed in the section 3 of the release note.

README.TXT

Product Release Notes for 3ware 9.5.3

Dell PowerVault MD3000 Support Matrix

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide

QuickSpecs. Models. Overview

GUID Partition Table (GPT)

Storage Controller Considerations

QuickSpecs. What's New. Models. Overview

QuickSpecs. What's New. Models. Overview

Storage Controller Considerations

RAID Controller Considerations

README.TXT

AHA PCI-to-Fast SCSI Host Adapter. Fast SCSI Connection for High-Performance SCSI Peripherals for Pentium PCs

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

Storage Controller Information

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Guide to SATA Hard Disks Installation and RAID Configuration

The use of the HP SAS Expander Card requires a minimum of 256MB cache on the SA-P410 or SA-P410i Controller.)

RocketRAID 600L. User s Guide. SATA 6Gb/s PCI-Express 2.0 RAID Host Adapters. Revision: 1.0 Nov. 19, 2012 HighPoint Technologies, Inc.

RocketRAID 3600 Series

AUA DuoConnect for Notebooks. Installation Guide

AOC-USASLP-S8i AOC-USASLP-S8iR USER'S GUIDE

SuperTrak EX SAS/SATA RAID Controller Compatibility List

A9890A RAID Smart Array 6402 Controller Quick Installation Guide

Retired. Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

DtS Data Migration to the MSA1000

Intel Solid State Drive Firmware Update Tool

Cisco UCS S3260 System Storage Management

HP Supporting the HP ProLiant Storage Server Product Family.

V10.4 Unified Firmware Update. Release Notes & Installation Instructions

Promise SuperTrak EX8760T/EX8768 Compatibility List V1.0

RocketRAID 231x/230x SATAII Host Adapter

Cisco UCS S3260 System Storage Management

SanDisk DAS Cache Compatibility Matrix

QuickSpecs. Models. Overview

ExpressSAS Host Adapter 6Gb v2.05 Linux

RocketRAID 231x SATAII Host Adapter

Dell PowerVault MD3000i Support Matrix

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

Cisco UCS S3260 System Storage Management

iscsi Storage Appliance Getting Started Guide

maxview Storage Manager & ARCCONF Command Line Utility

Server Systems and Motherboards

Promise VessRAID 1000s Series Compatibility List V1.0

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

Drobo 5N2 User Guide

Adaptec RAID Series 3 & 5 Competitive Matrix

How To Install Windows Update Vista Without Cd Dell Inspiron 1720

Format Hard Drive Using Windows 7 Recovery Disk

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

NEC Express5800/R120e-1M System Configuration Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

NVIDIA / JMicron RAID Installation Guide

Drobo B810n Getting Started Guide

1 Drobo 8D User Guide Before You Begin Product Features at a Glance Checking Box Contents... 9

Adaptec SCSI RAID 2120S/2200S. Software User s Guide

SUPERTRAK EX4350 USER MANUAL. Version 1.0

Dell PowerEdge RAID Controller S140 - PERC S140. User s Guide

Guide to SATA Hard Disks Installation and RAID Configuration

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 6 Supporting Hard Drives

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide

Product Release Notes

Serial Attached SCSI RAID Controllers

Guest Operating System Installation Guide. May 28, 2008

Magic Card User Manual

Guest Operating System Installation Guide. February 25, 2008

Data rate - The data rate is the number of bytes per second that the drive can deliver to the CPU.

Guest Operating System Installation Guide. March 14, 2008

C A S P E R TECH EDITION 10 USER GUIDE

Installation Manual for Sonnet RAID Controller

RocketRAID 2700 Series

HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system.

NEC Express5800/R120d-2M Configuration Guide

Dell PowerEdge RAID Controller (PERC) S130 User s Guide

Transcription:

README.TXT Adaptec ASR-5085/ASR-5405/ASR-5445/ASR-5805/ASR-51245/ASR-51645/ASR-52445 Unified Serial Controllers Adaptec ASR-2045/ASR-2405 Unified Serial Controllers Adaptec ASR-5405Z/ASR-5445Z/ASR-5805Z Unified Serial Controllers NOTE: All Adaptec products are UL listed and for use only with UL listed ITE. as of October 29, 2009 Please review this file for important information about issues and errata that were discovered after completion of the standard product documentation. In the case of conflict between various parts of the documentation set, this file contains the most current information. NOTE: The latest firmware, BIOS, drivers and documentation can be downloaded from www.adaptec.com when they become available. The following information is available in this file: 1. Software and Documentation 1.1 Controller & Utility Software 1.2 Documentation on this CD 2. Installation and Setup 2.1 Installation Instructions 2.2 MaxIQ SSD Cache Performance Kit Setup 2.3 Power Management Setup 2.4 Linux Setup 2.5 VMware Setup 3. General Cautions 4. Known Limitations 4.1 ACU Utility 4.2 AFU Utility 4.3 Creating an Array from the Adaptec Storage Manager CD 4.4 Using the Controller with an Adaptec S50 JBOD Enclosure 4.5 UnixWare and OpenServer 4.6 OpenServer 6.0 4.7 SuSE Linux Enterprise Server 10 with Service Pack 2 4.8 Hot-adding Disk Drives 4.9 SuperMicro Disk Drive Enclosures 4.10 Using the Controller with the SuperMicro X7DBE Motherboard 4.11 Using the Controller with a Seagate Barracuda 1TB SATA Drive 4.12 Intel SE7525RP2 and SE7320EP2 Motherboards 4.13 Windows Server 2008 64-Bit SCSIport Driver 4.14 Boot Drive Failure after OCE/RLM 4.15 Online Capacity Expansion (OCE) Limits 4.16 Power Management under FreeBSD 4.17 Using RAID10 under FreeBSD 4.18 Power Management with Seagate SAS Drive ST31000640SS 4.19 Linux Cache Synchronization 4.20 Listing Devices in VMware ESX 4.0 Console 4.21 BIOS Hangs When Booting RAID Controller with Batteryless Backup (ZMCP) 4.22 Updating Firmware on Hitachi HUS1514xxVLS300 SAS drives 4.23 Installing Windows OS from Direct-Attached Non-DASD Device 4.24 MaxIQ SSD Cache Performance 4.25 Exceeding 2TB LUN Size on VMware ESX Server 4.26 PHY Rate Limitations on Western Digital 2TB WD2002FYPS Hard Drives 1. Software and Documentation Page 1

1.1. Controller & Utility Software readme.txt Note: The latest versions of firmware, BIOS and driver software can be downloaded from www.adaptec.com when they become available. - BIOS - ACU - Windows Drivers 64-bit) 64-bit) o Windows Server 2008, Enterprise, Standard, Datacenter (32-bit, 64-bit) o Windows Server 2008 R2, Enterprise, Standard, Datacenter (32-bit, o Windows Server 2003, Enterprise, Standard, Datacenter (32-bit, 64-bit) o Windows Server 2003 R2, Enterprise, Standard, Datacenter (32-bit, o Windows XP, All versions o Windows Vista, All versions o Windows 7, All versions - Linux Drivers o Red Hat Enterprise Linux 4.7, IA-32 and x64 o Red Hat Enterprise Linux 5.3, IA-32 and x64 o SuSE Linux Enterprise Server 9, IA-32 and x64 o SuSE Linux Enterprise Server 10, IA-32 and x64 - FreeBSD Drivers o FreeBSD 6.4, 7.1 - SCO Drivers o OpenServer 6.0 o UnixWare 7.1.4 - VMware Drivers o VMware ESX Server 3.5, 4.0 - Sun Solaris Drivers o Solaris 10 Update 4 1.2. Documentation on this CD - Adaptec SAS RAID Controllers Installation and User's Guide - Adaptec RAID Controller Command Line Utility User's Guide - Adaptec SAS RAID Controllers Quick Start Guide - Adaptec SAS RAID Controllers README.TXT file 2. Installation and Setup 2.1 Installation Instructions The Adaptec SAS RAID Controllers Installation and User's Guide contains complete installation information for the controllers and drivers, as well as complete instructions for all utilities. The Adaptec Storage Manager User's Guide Page 2

contains complete installation information for the Adaptec Storage Manager software. 2.2 MaxIQ SSD Cache Performance Kit Setup o The Adaptec MaxIQ SSD Cache Performance Kit supports Adaptec MaxIQ-branded/Intel X25-E Solid State Disks only. o You can install a maximum of 4 SSDs on a controller for MaxIQ caching. o Before connecting the MaxIQ SSDs to your controller, install the latest firmware, driver software and Adaptec Storage Manager (ASM), as described in the manual. Shut down the system, then connect the SSDs to one of the SATA/SAS ports on your controller following these steps: 1. Observe the following precautions: o Keep the drive in the protective anti-static container until you are ready to install the SSD in your server. o Handle the SSD with care. Do not touch the connectors. o Do not remove the encasement or disassemble the SSD; such actions void the warranty. 2. Plug the SSD into an array that is connected to a Series 2, Series 5, or Series 5Z Adaptec Controller. Do NOT plug the SSD into a blank SATA slot on the motherboard; the controller will not recognize it. 3. For servers with a standard 2.5-inch drive tray, install the SSD directly into the tray. If your server does not have a standard 2.5-inch drive tray, use a bracket/sled which enables it to fit properly. (SSD hot-plug is supported.) o After connecting the SSDs to your controller, use either the CTRL+A/BIOS utility or ASM to initialize the SSD(s) and add one or more SSDs to the MaxIQ pool. Create a RAID array or Simple Volume with read caching enabled, then enable MaxIQ caching on the array. (See the user's guide for details on these procedures.) 2.3 Power Management Setup You must use a compatible combination of Adaptec Storage Manager and controller firmware and driver software to use the power management feature. All software components must support power management. You can download the latest controller firmware and drivers from the Adaptec Web site at www.adaptec.com. 2.4 Linux Setup Before installing the Linux operating system on a logical drive, Adaptec recommends clearing (removing) old data first. If you do not remove old data prior to installation, the OS may not boot. As a workaround, use the boot parameter 'aacraid.wwn=2'. 2.5 VMware Setup Upgrading the VMware driver to ESX 4.0 is currently supported only for non-bootable arrays. For bootable arrays, upgrading will result with booting only to an ESX recovery shell with no Page 3

option to reboot to ESX server normally. NOTE: A newer version of the driver will be posted on the Adaptec web site, when available, at www.adaptec.com. 3. General Cautions - While an array is being built or cleared, do NOT remove and re-insert any drive from that array. Doing so may cause unpredictable results for any of the controller's arrays. - Do NOT move drives containing an array from one controller to another while the power is on. Doing so could cause the loss of the array configuration or data, or both. Instead, power off both affected controllers, move the drives, and then restart. 4. Known Limitations 4.1 ACU Utility o On some Intel and IBM systems, when you try to run the ACU utility, this message appears: "Not enough free memory to load the utility! Press any key to attempt loading the utility forcibly OR Wait for the system initialization to be completed [Default]" This is normal. On Intel systems, wait for the system initialization to be completed. Then the ACU will run. On IBM systems, press any key when prompted to load the utility forcibly. o The ACU erroneously displays deleted logical drives in the JBOD list. The logical drive(s) continue to appear in the JBOD list until you delete all of the JBODs. o With some enclosures, the ACU displays incorrect box/slot information for managed disk drives; for example, Exp/Phy instead of Box/Slot. 4.2 AFU Utility o When running the AFU in Menu Mode, you can update (flash) only one controller at a time. You must reboot the system before updating the next controller. o Flashing a 5-series high-port controller (51245, 51645, 52445) with down-level firmware and an older version of the AFU crashes the system. To recover, you must use a Mode 0 reset using the latest firmware version. See the user's guide for details on the Mode 0 method. 4.3 Creating an Array from the Adaptec Storage Manager CD When you create an array with the Adaptec Storage Manager bootable CD, the maximum size of the array is 2 TB. 4.4 Using the Controller with an Adaptec S50 JBOD Enclosure Page 4

Temperature warnings from the Adaptec S50 JBOD Enclosure with firmware version T016 are not shown in Adaptec Storage Manager (or on the enclosure). To correct the problem, upgrade to the latest firmware version. 4.5 UnixWare and OpenServer Adding or moving controllers in an existing UnixWare or OpenServer system may cause some device resources to change, which may lead to the operating system being unable to boot. Currently, there is no workaround available in the operating system. Before installing the operating system, make sure all PCI devices are either enabled or installed. 4.6 OpenServer 6.0 Arrays may not be displayed correctly, even after you restart your computer. To resolve the problem: As root, run 'resmgr -r -m vtoc' until it fails. Then, as root, run '/etc/conf/bin/idconfupdate -f'. Then, reboot. 4.7 SuSE Linux Enterprise Server 10 with Service Pack 2 If your boot array is installed on the controller, and the boot OS is SLES10 SP2 with driver version 1.1.5-2458, you must add 'aacraid.wwn=1' to the kernel boot command line. Alternatively, install the latest aacraid driver. 4.8 Hot-adding Disk Drives o If you hot-add multiple disks simultaneously to a large configuration (100 disk drives or more), it may take a large amount of time before those disk drives appear in Adaptec Storage Manager. o With Intel Backplanes AXX4DRV3GEXP and AXX6DRV3GEXP, if a drive bay is empty at enclosure power on and then a SATA disk drive is hot-added into the empty bay, the controller does not detect the new disk drive. To work around this issue, remove and re-insert the SATA disk. 4.9 SuperMicro Disk Drive Enclosures If the controller does not detect disk drives installed in a SuperMicro M28E2 Mobile Rack, use backplane SAS connectors marked with "SAS In" only. 4.10 Using the Controller with a SuperMicro X7DBE Motherboard The ASR-2405 and ASR-2045 do not support the SuperMicro X7DBE motherboard. Adaptec recommends using the SuperMicro X7DBE+. 4.11 Using the Controller with a Seagate Barracuda 1TB SATA Drive To ensure reliability when using Adaptec 2-series and 5-series controllers with a Seagate Barracuda ES.2 1TB SATA Drive (ST31000340NS), Adaptec recommends using Seagate firmware version AN05 or SN06(or higher). 4.12 Intel SE7525RP2 and SE7320EP2 Motherboards Page 5

The Intel SE7525RP2 and SE7320EP2 motherboards do not support Mode 0 flash. These motherboards use 64-bit PCI addressing. The AFU currently supports 32-bit PCI addresses only. 4.13 Windows Server 2008 64-Bit SCSIport Driver The Windows Server 2008 64-Bit SCSIport driver is in the process of being certified and is not supported in this release. Use the Storport driver instead. 4.14 Boot Drive Failure after OCE/RLM The system may fail to boot after a boot drive OCE/RLM (online capacity expansion/raid level migration). To correct the problem, verify that the boot drive is still listed as the first logical device in Adaptec Storage Manager (ASM). If not, use the Control-A BIOS utility to reselect the proper boot device. 4.15 Online Capacity Expansion (OCE) Limits This release supports a maximum of 8 concurrent OCE tasks in the RAID array migration wizard. 4.16 Power Management under FreeBSD The FreeBSD driver does not support power management in this release. 4.17 Using RAID10 under FreeBSD If a RAID10 array fails under FreeBSD the firmware may crash causing the system to reboot automatically. 4.18 Power Management with Seagate SAS Drive ST31000640SS Power Management is not supported by the Seagate ST31000640SS SAS drive. (The drive powers down but will not power up without rebooting.) 4.19 Linux Cache Synchronization With Linux driver 1.1-5-2459 (or higher), you may see an improvement in performance if you suppress cache synchronization. For a controller with battery back-up, add 'options aacraid cache=6' to the /etc/modprobe.conf.local file. To completely suppress cache synchronization, add 'options aacraid cache=2'. Then, reboot. Note that the smaller value provides no protection in case of a power outage. 4.20 Listing Devices in VMware ESX 4.0 Console After deleting an array with ARCCONF, the VMware ESX 4.0 Console will hang if you list available devices with 'fdisk -l'. As a work-around, rescan first, then try 'fdisk -l'. 4.21 BIOS Hangs When Booting RAID Controller with Batteryless Backup (ZMCP) Possible Cause: After a system shutdown, the ZMM-100DB daughterboard remains active for several minutes. The Super Cap connector may have been improperly removed and/or re-inserted with a charge still present. Solution: Plug the Super Cap connector in when the system is off Page 6

and, if the yellow activity LED is illuminated on the ZMM-100DB daughterboard attached to RAID Controller, wait for the LED activity indicator to go out. This may take several minutes. The system should then boot normally. 4.22 Updating Firmware on Hitachi HUS1514xxVLS300 SAS drives Firmware upgrade on Hitachi HUS151473VLS300 and HUS151436VLS300 SAS drives is not supported for packet sizes below 4K (512/1024/2048). 4.23 Installing Windows OS from Direct-Attached Non-DASD Device Adaptec RAID controllers do not support Windows OS installation from direct-attached Non-DASD devices ("Direct Access Storage Devices"), such as a tape drive, CD-ROM, or DVD-ROM. Adaptec recommends using a motherboard IDE or SATA DVD-ROM/CD-ROM device to install the Windows OS on a RAID array. 4.24 MaxIQ SSD Cache Performance The MaxIQ cache contents is lost if the OS is not shut down cleanly (for example, by pressing the reboot button or pulling the power). When the system is restarted, the cache is rebuilt; until that time, you may see a temporary loss in performance. 4.25 Exceeding 2TB LUN Size on VMware ESX Server Under VMware, if you create a logical drive with greater than 2TB of capacity, the OS will only be able to access the remaining storage above 2TB. For instance, with the 3.5TB LUN, only 1.5TB will be accessible; with a 5TB LUN, only 1TB will be accessible (first 2TB+2TB are skipped); and so on. 4.26 PHY Rate Limitations on Western Digital 2TB WD2002FYPS Hard Drives To avoid data-phase errors with Western Digital 2TB WD2002FYPS hard drives, the PHY rate is set automatically to 1.5Gb/s rather than the maximum rate of 3.0Gb/s. In ASM and the Control-A/BIOS, the device properties continue to show the maximum rate (3.0Gb/s), not the reduced rate. NOTE: This release includes a new Control-A/BIOS option for low-port RAID controllers that allows you to set the PHY rate to Auto (default), 1.5Gb/s, or 3.0Gb/s. (c) 2009 Adaptec, Inc. All Rights Reserved. This software contains the valuable trade secrets of Adaptec or its licensors. The software is protected under international copyright laws and treaties. This software may only be used in accordance with the terms of its accompanying license agreement. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without prior written consent of Adaptec, Inc., 691 South Milpitas Blvd., Milpitas, CA 95035. Page 7