Blood flow modeling in a synthetic cylindrical vessel for validating methods of vessel segmentation in MRA images

Similar documents
Application of level set based method for segmentation of blood vessels in angiography images

Probabilistic Tracking and Model-based Segmentation of 3D Tubular Structures

Vessel Centerline Tracking in CTA and MRA Images Using Hough Transform

Analysis of Cerebral Blood Flow from Small Rodents

2D Vessel Segmentation Using Local Adaptive Contrast Enhancement

Comparison of Vessel Segmentations using STAPLE

The SIMRI project A versatile and interactive MRI simulator *

Automatic Cerebral Aneurysm Detection in Multimodal Angiographic Images

CFD simulations of blood flow through abdominal part of aorta

XI Conference "Medical Informatics & Technologies" VALIDITY OF MRI BRAIN PERFUSION IMAGING METHOD

High dynamic range magnetic resonance flow imaging in the abdomen

Phantom-based evaluation of a semi-automatic segmentation algorithm for cerebral vascular structures in 3D ultrasound angiography (3D USA)

Magnetic Resonance Imaging Velocity. Information. Joe Lee. April 4, 2000

Rigid and Deformable Vasculature-to-Image Registration : a Hierarchical Approach

A Hybrid Method for Coronary Artery Stenoses Detection and Quantification in CTA Images

Automatic Ascending Aorta Detection in CTA Datasets

Volume visualization. Volume visualization. Volume visualization methods. Sources of volume visualization. Sources of volume visualization

Comparison of Vessel Segmentations Using STAPLE

CPM Specifications Document Healthy Vertebral:

3D Vascular Segmentation using MRA Statistics and Velocity Field Information in PC-MRA

coding of various parts showing different features, the possibility of rotation or of hiding covering parts of the object's surface to gain an insight

Solved with COMSOL Multiphysics 4.2

Guide wire tracking in interventional radiology

Explorative Building of 3D Vessel Tree Models 1) Technology, Inffeldgasse 16 2.OG, A-8010 Graz, Austria

MRA Image Segmentation with Capillary Active Contour

From medical imaging to numerical simulations

Estimating Arterial Wall Shear Stress 1

Microwell Mixing with Surface Tension

Terminal Falling Velocity of a Sand Grain

Computational Modeling and Simulation of the Human Duodenum

Automatic Vascular Tree Formation Using the Mahalanobis Distance

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study

Modeling and preoperative planning for kidney surgery

3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations

Multiscale Blood Vessel Segmentation in Retinal Fundus Images

TUMOR DETECTION IN MRI IMAGES

Accurate Quantification of Small-Diameter Tubular Structures in Isotropic CT Volume Data Based on Multiscale Line Filter Responses

Development of Hybrid Fluid Jet / Float Polishing Process

A Ray-based Approach for Boundary Estimation of Fiber Bundles Derived from Diffusion Tensor Imaging

Scene-Based Segmentation of Multiple Muscles from MRI in MITK

Porous Reactor with Injection Needle

White Pixel Artifact. Caused by a noise spike during acquisition Spike in K-space <--> sinusoid in image space

Chapter 3 Set Redundancy in Magnetic Resonance Brain Images

Nonrigid Motion Compensation of Free Breathing Acquired Myocardial Perfusion Data

Package vesselr. R topics documented: April 3, Type Package

Medical Images Analysis and Processing

Lecture 6: Medical imaging and image-guided interventions

Applications Guide for Interleaved

Linköping University Post Print. Phase Based Level Set Segmentation of Blood Vessels

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

ACQUIRING AND PROCESSING SUSCEPTIBILITY WEIGHTED IMAGING (SWI) DATA ON GE 3.0T

Image Acquisition Systems

MR Advance Techniques. Vascular Imaging. Class III

DETECTING and extracting blood vessels in magnetic resonance

A Geometric Flow for Segmenting Vasculature in Proton-Density Weighted MRI

Magnetic Resonance Elastography (MRE) of Liver Disease

Pearling: Medical Image Segmentation with Pearl Strings

SIMULATION D'IRM ANGIOGRAPHIQUE PAR EXTENSION DU LOGICIEL JEMRIS

Solved with COMSOL Multiphysics 4.2

Blood Particle Trajectories in Phase-Contrast-MRI as Minimal Paths Computed with Anisotropic Fast Marching

Nearly automatic vessels segmentation using graph-based energy minimization

Numerical Investigation of Non-Newtonian Laminar Flow in Curved Tube with Insert

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Edge Detection in Angiogram Images Using Modified Classical Image Processing Technique

MR IMAGE SEGMENTATION

Level Set-Based Integration of Segmentation and Computational Fluid Dynamics for Flow Correction in Phase Contrast Angiography

CHAPTER 9: Magnetic Susceptibility Effects in High Field MRI

Human Heart Coronary Arteries Segmentation

Modeling and Simulation of Single Phase Fluid Flow and Heat Transfer in Packed Beds

Research Article Simulation of High-Resolution Magnetic Resonance Images on the IBM Blue Gene/L Supercomputer Using SIMRI

Evaluation of Diffusion Techniques for Improved Vessel Visualization and Quantification in Three-Dimensional Rotational Angiography

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY

Compressed Sensing for Rapid MR Imaging

Introduction to Medical Image Processing

The viscous forces on the cylinder are proportional to the gradient of the velocity field at the

Use of MRI in Radiotherapy: Technical Consideration

A Transmission Line Matrix Model for Shielding Effects in Stents

A 3-D Modeling Scheme for Cerebral Vasculature from MRA Datasets

SIGMI Meeting ~Image Fusion~ Computer Graphics and Visualization Lab Image System Lab

Advanced Visual Medicine: Techniques for Visual Exploration & Analysis

BME I5000: Biomedical Imaging

Modelling of Levitation Melting using a Fixed Mesh Method

Solved with COMSOL Multiphysics 4.2

Optimizing Bio-Inspired Flow Channel Design on Bipolar Plates of PEM Fuel Cells

A validation of the biexponential model in diffusion MRI signal attenuation using diffusion Monte Carlo simulator

Interactive segmentation of vascular structures in CT images for liver surgery planning

Fiber Selection from Diffusion Tensor Data based on Boolean Operators

Biophysical Techniques (BPHS 4090/PHYS 5800)

UNIVERSITY OF SOUTHAMPTON

Three-dimensional synthetic blood vessel generation using stochastic L-systems

TECHNICAL REPORT. Smart Linking of 2D and 3D Views in Medical Applications

Evaluation of Hessian-based filters to enhance the axis of coronary arteries in CT images

Computational Medical Imaging Analysis Chapter 4: Image Visualization

Design of a fourth generation prosthetic heart valve: tri-leaflet valve

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

A Comprehensive Method for Geometrically Correct 3-D Reconstruction of Coronary Arteries by Fusion of Intravascular Ultrasound and Biplane Angiography

DUE to beam polychromacity in CT and the energy dependence

RADIOMICS: potential role in the clinics and challenges

Transcription:

Blood flow modeling in a synthetic cylindrical vessel for validating methods of vessel segmentation in MRA images Grzegorz Dwojakowski, Artur Klepaczko, and Andrzej Materka Abstract The paper presents new concept of validating blood segmentation methods. The idea is to create a Magnetic Resonance Angiography simulator which can generate synthetic MRA images based on pattern objects. In order to reproduce angiographic sequences such as Time of Flight or Susceptibility Weighted Imaging, laminar flow in digital phantoms was modeled. Results were presented and discussed. Comparison of the new concept with existing validation methods was carried out. 1 Introduction Magnetic Resonance Imaging (MRI) is one of the most popular radiology techniques used to obtain anatomical images of the human body [4]. Modern MRI scanners can receive high resolution 3D images with good contrast between different tissues. In comparison to traditional X-rays or Computer Tomography, MRI is noninvasive because it does not use ionizing radiation. Another advantage is the number of different sequences. Using angiographic techniques such as Time of Flight [3] and Susceptibility Weighted Imaging [18] methods combined together, results in a full map of veins and arteries [9]. Such a map carries important information about patient health and can be used in diagnosis and planning surgical operations. Image segmentation methods are created in order to help physicians in analyzing those complex images [6]. Separating vessels from other tissues can result in revealing important information. Reconstructing vessel walls may lead to detecting clots, narrowings or other anomalies much faster than without image processing techniques [21]. Although results of blood segmentation algorithms can increase the scope of knowledge about patient health, they are Lodz University of Technology, Institute of Electronics, ul. Wolczanska 211/215, 90-924 Lodz grzegorz.dwojakowski@gmail.com aklepaczko@p.lodz.pl materka@p.lodz.pl 1

2 Grzegorz Dwojakowski et al. Fig. 1 Comparison of standard MRI imaging sequence with described concept. rarely used in clinics. Diagnosticians cannot rely on segmented images and must make diagnoses based on their knowledge and medical experience. This is mainly due to problems with validating results of blood segmentation methods [13]. Their results cannot be compared with some ground truth pattern. Firstly, after transformation and rasterization of input data during the imaging sequence, a significant part of information is lost irrevocably. Secondly, there is no method to get precise dimensions of a patient vessel network. It is not possible to measure such complex structures inside a human body. In order to use image processing methods for medical purposes there is a need of creating a reliable validation method. A method which not only allows to evaluate the correctness of reconstructed structures but also helps in the process of developing segmentation algorithms. To meet these requirements we propose a new method of validation. We want to simulate angiographic imaging sequences using a computer unit (cf. Fig. 1). This allows us to replace real image data with a 3D digital model of human vessels. A properly implemented simulator working on known patterns will create an effective and objective criterion of validation for image segmentation methods. In standard MRI imaging, contrast is acquired thanks to chemical and physical differences between tissues. However, in magnetic resonance angiography (MRA) sequences voxel brightness is also dependent on the position of proton particles in time. Here, the phenomenon of blood flow is utilized. During the imaging process blood is moving in vessels while other tissues are stationary. Therefore, an appropriate simulation of this phenomenon is crucial for the postulated approach to succeed. At an early stage of this project development laminar flow was modeled and applied in a simple digital tubular phantom vessel. The reason for this is the existence of real test objects with exactly the same parameters. After performing blood flow simulation for digital phantom there is a possibility to

Blood flow modeling in a synthetic cylindrical vessel... 3 measure values obtained in a physical model and to compare the results. This phantom can be used not only to test the correctnessofblood flow simulation but also to validate results of MRA sequences. If successful this could lead to using more complex vessel models, similar to the ones in a human body. 2 Blood vessel segmentation Image segmentation techniques are used to divide data into regions with common characteristics. In case of MRA images the purpose is to separate blood vessels from other tissues. As mentioned earlier, it allows to portray arteries and veins as a 3D model. Data in that form is much easier to be analyzed than 2D cross-sections. Additionally, segmentation allows to automatically search for risk regions based on vessel diameter. There are plenty of segmentation algorithms to choose from [15]. Depending on which partofthe body hasbeen imagedand what types ofvesselsneed to be detected different methods should be applied. We can divide vessel segmentation techniques into two main categories: the mathematical morphology approach and geometrical methods [10]. Algorithms from the first group are considered to be fast but not very effective. The best example is image thresholding or a more advanced technique known as region growing. Output images are obtained almost instantly, but e.g in cerebrovascular imaging it is impossible to separate small veins from white matter or even from the bone. There are more advanced morphology methods such as watershed segmentation or top-hat. Algorithms from the second group not only use the voxel brightness level but also the relative position of neighboring points. Deformable models or generalized cylinders approach are thought to give accurate results. However, the time needed to process a high resolution MRA 3D image is very long and the reconstruction of veins with small diameters (compared to the size of the voxel) is impossible. Base on experiments, low level geometric methods seem to be more appropriate. Usage of Hessian matrix to find local direction of white tubular objects is one of these methods [11]. In order to test various attempts and develop new ones, an image segmentation application was created. Using implemented image functions and filters there is a possibility to build and run complex algorithms in a short time. Additionally, thanks to an intuitive graphic user interface (see Fig. 2) and advanced task tracking system, changing used parameters or adding new methods to existing process posses no problem.

4 Grzegorz Dwojakowski et al. Fig. 2 Graphical user interface of created segmentation software. 3 Validation of biomedical image processing methods Although some segmentation algorithms results looks promising it is difficult to perform an objective assessment of their correctness [8]. The Most common method of validation is relying on medical knowledge and subjective assessment made by physicians [5]. However, gathered information cannot be used as a reliable pattern due to uncertainty and poor reproducibility. The Second group of validation methods is based on physical phantoms. These artificial structures are mainly used to calibrate MRI scanners, but can also be used to test results of segmentation methods. This time, the pattern is familiar and comparison can be made. This method of validation is much more accurate, but has its drawbacks. Physical phantoms are expensive and, so far, there is no structure similar to the real blood network. This is a result of complicated topology and small vessel diameters. The third group consists of digital phantoms. Similarly to physical structures they provide a priori known and measurable reference pattern [1]. A complex geometrical shape is much easier to create using computer 3D graphics. What is more, they are much faster and cheaper to create. They can be duplicated with different parameters and can be used to create large sets of test objects. The only disadvantage is that it is not possible to use these phantoms in a real MRI scanner. All three methods have their drawbacks and potentials. An ideal solution seems to be a combination of all methods. As a pattern we would like to use easy to create digital objects, with known dimensions and blood flow inside it.

Blood flow modeling in a synthetic cylindrical vessel... 5 4 MRA Simulation Problems with validating segmentation results can be solved by an MRA simulator. Simulating movement of blood in vessels allows implementing angiographic sequences and obtaining images similar to those from a real scanner (with noise and distortion caused by imaging sequence). Contrary to image acquisition using real MRI apparatus, the input object is known and can be used as a reference source. Simulating the physical phenomena of an MRI scanner is a complex problem.onlyafewattemptstothisissuecanbefoundinliterature[17,16,14,2], but they work only for static objects. In case of angiographic imaging, these methods cannot be used because sequences such as Time of Flight (ToF) and Susceptibility Weighted Imaging (SWI) are based on blood flow in arteries and veins. In ToF, image contrast is acquired by unsaturated molecules of blood which flows through acquisition volume in a given time moment. SWI depends on blood oxygenation and uses amplitude and phase gradient echo, with compensated blood flow effect. 5 Blood flow modeling Simulation of laminar flow is performed in COMSOL Multiphysics software by solving incompressible Navier-Stokes equations. This type of blood movement, known also as stratified flow, assumes that fluid moves in parallel layers [12]. Each layer has its own speed and slides past one another so there is no lateral mixing. Blood flows in one direction. Velocity is greatest in the middle of the cylinder. The value decreases as we approach the vessel wall. For simulating blood flow in a pipe this model is sufficient. For more complex structures with many branches and bifurcation there is a need to use turbulent model of flow. To solve flow equations there is a need to set viscosity and density of the liquid. Based on literature these values for blood were adjusted to 1060 Kg/m 3 (density) and 0.005 Ns/m 2 (dynamic viscosity). The goal of this part of the project is to simulate blood flow in a complex artificial model of a vessel tree. It cannot be done until it is certain that the simulation is consistent with the real flow. That is the reason why the geometric shape of a digital pattern should be uncomplicated and identical to the physical phantom. If successful this could lead to using vessel models, similar to these in a human body. Firstly, Geometry objects are created on the model of the Flow Phantom Set produced by Shelley Medical Imaging Technologies [20]. This Model is compatible with the high class CompuFlow 1000 MR pump which allows to force and precisely control the flow in test objects [19].

6 Grzegorz Dwojakowski et al. This Phantom Set consists of 4 straight (Fig. 3a) and 1 U-bend tubes (Fig. 3b). The geometrical parametrs of the tubes are as follows: Straight tubes phantom QA-STV (all tubes are 207 mm long) 8 mm diameter vessel with 75% sinusoidal stenosis by diameter 8 mm diameter vessel 8 mm diameter vessel with 50% sinusoidal stenosis by diameter 5 mm diameter vessel U-bend phantom QA-USV 8 mm diameter, 44 mm midline radius-of-curvature There is no fluid leek through the walls and no deformation caused by flow. This simplification makes the model easier to implement. Created digital models are an exact copy of their real equivalents, including details such valves and silicone control drillings (cf. Fig. 4). (a) (b) Fig. 3 Physical silicon phantoms: a) straight cylinders with stenosis, b) U-bend tube. (a) (b) Fig. 4 Digital phantoms based on respective real models illustrated in Fig. 3.

Blood flow modeling in a synthetic cylindrical vessel... 7 Fig. 5 Pressure distribution in 4 tubular phantoms. Value range is 11136 11208 Pa. Fig. 6 Velocity magnitude in 4 tubular phantoms. Value range is 0 0.18 m/s. 6 Results Blood flow simulation was performed for both phantom sets. Fluid flow is forced by setting pressure difference between input (11208 Pa) and output (11148 Pa) boundaries [7]. There is no slip allowed through phantom walls. Distribution of pressure and velocity of particles inside straight vessels are depicted in Fig. 5 and 6. In a vessel with a 5 mm diameter pressure distribution is linear. According to the theory of laminar flow, highest velocity is obtained in the center of the tube. Moving towards the wall this value decreases. Based on the laminar flow solution, particle tracing was performed.

8 Grzegorz Dwojakowski et al. The Number of molecules was set to 32. All of them were defined by density and diameter. At the beginning, all particles are located at input boundary. With time, each element moves towards the exit. All trajectories are straight lines parallelto the main axis ofthe vessel.the fastest particles reachits goal in about 2.5 second; ones next to the wall are over five times slower. Results from this study are relevant to values obtained in laminar flow simulation. Similar situation can be observed for a second straight tube of 8 mm. The main difference is time of flight of particles in the middle of the tube which equals 1.19 seconds. These values are relevant to the theory where local velocity depends on distance from the edge of the vessel. Next two phantoms contain sinusoidal stenossis. Parameters of the flow are still the same. Due to narrowing, pressure distribution is no longer a linear function. Although in a phantom with 75% stenosis values of magnitude velocity are similar to those in a straight tube, small acceleration is visible in the narrowing region. The fastest particle reaches a distance of 207 mm in 1.25 s which is 0.06 slower than in previous test. In the case of a vessel with 50% narrowing (Fig. 7), pressure applied on the particles before reaching stenosis is almost constant and equals the input parameter. Velocity magnitude is no longer a constant value. It changes from 0.2 m/s in the input section to about 0.4 m/s in the middle of stenosis. Time of the flow is much longer and equals 1.79 s. After the narrowing, the density of particles is higher because they do not return to their previous positions. The final U-bend phantom is different from previous 4 tubes. It is much longer and bent to an angle of 180 degrees. Because of the lack of narrowings, pressure is a linear function. Time offlightforthe particlesinthe middle equals3.55s. In the curvesectionsmall deviations from the central axis can be observed in the molecules trajectory (cf. Fig. 8). Fig. 7 Particle trajectories in vessel with 50% stenosis by diameter.

Blood flow modeling in a synthetic cylindrical vessel... 9 Fig. 8 Velocity magnitude in U-bend phantom. Value range is 0 0.12. 7 Conclusion A new concept of validating blood segmentation methods was presented. The idea was compared with existing methods. For the purpose of implementing angiographic sequences blood, flow was simulated in digital phantoms specially created for this project. Expected values and 3D coordinates were gathered and will be used in future validation process. Although much work still needs to be done, this reportbrings us closerto the final goalofaproject an MRA Simulator Acknowledgements This paper was supported by the Polish National Science Centre grant no. N N519 650940. References 1. Aubert-Broche, B., Griffin, M., Pike, G., Evans, A., DL., C. (2006) IEEE Transactions on Medical Images 25:1410 1416

10 Grzegorz Dwojakowski et al. 2. Benoit-Cattin, H., Collewet, G., Belaroussi, B., Saint-Jalmes, H., Odet, C. (2005) Journal of Magnetic Resonance 173:97 115 3. Bernstein, M.A., Huston, J., Lin, C., Gibbs, G.F., Felmlee, J.P. (2001) Magn Reson Med 46(5):955 962 4. Bogorodzki, P. (2009) Przeglad Elektrotechniczny 9:40 45 (in Polish) 5. Castro, F., Pollo, C., Meuli, R., Maeder, P., Cuisenaire, O., Cuadra, M., Villemure, J., Thiran, J. (2006) IEEE Transactions on Medical Images 25:1440 1448 6. Chmielewski, L., Kulikowski, J., Nowakowski, A. (2003) Obrazowanie biomedyczne, vol. 8. Akademicka oficyna wydawnicza EXIT (in Polish) 7. Cieslicki, K. (2001) Hydrodynamiczne uwarunkowania krazenia mozgowego. Akademicka Oficyna Wydawnicza EXIT (in Polish) 8. Crum, W., Camara, O., Derk, L., Hill, G. (2006) IEEE Transactions on Medical Images 25:1451 1461 9. Deistung, A., Dittrich, E., Sedlacik, J., Rauscher, A., Reichenbach, J.R. (2009) J Magn Reson Imaging 29(6):1478 84 10. Eiho, S., Qian, Y. (1997) Proc. Computers in Cardiology 7:525 528 11. Frangi, R.F., Niessen, W.J., Vincken, K.L., Viergever, M.A. (1998) Multiscale vessel enhancement filtering. In: Proc. of MICCAI, pp. 130 137. Springer-Verlag, Berlin- Heidelberg-New York 12. Jezowiecka-Kabsch, K., Szewczyk, H. (2001) Mechanika plynow. Oficyna Wydawnicza Politechniki Wroclawskiej (in Polish) 13. Jonnin, P., Krupinski, E., Warfield, S. (2006) IEEE Transactions on Medical Images 25:1405 1409 14. Jurczuk, K., Kretowski, M. (2009) Biocybernetics and Biomedical Engineering 29:31 46 15. Kirbas, C., Quek, F. (2004) ACM Comput. Surv. 36(2):81 121 16. Kwan, R.S., Evans, A., Pike, G. (1999) Medical Imaging, IEEE Transactions on 18:1085 1097 17. Petersson, J., Christoffersson, J., Golman, K. (1993) Magnetic Resonance Imaging 11:557 568 18. Reichenbach, J.R., Haacke, E.M. (2001) NMR in Biomedicine 14:453 467 19. Shelley, M.I.T. (2013) Cardioflow 1000 MR computer controlled flow system 20. Shelley, M.I.T. (2013) MRI quality assurance flow phantom set 21. Strzelecki, M., Materka, A., Kocinski, M., Szczypinski, P., Deistung, A., Reichenbach, J. (2010) Acta Bio-Optica et Informatica Medica INZYNIERIA BIOMEDYCZNA 16:167 172 (in Polish)