(Catalog Numbers 1394-FK10TS and -FK22TS)

Similar documents
RGU Main Control Board Replacement Firmware Version 3.01

Installing Your 1394 Drive Interface Module

Kinetix 6000 Axis Module and Shunt Module

PowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

PowerFlex 700S Phase II Drives DriveLogix Option Card Battery Extension Cable

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

PowerFlex DC Stand-Alone Regulator (SAR) Field Circuit Board

Ferrite Core for Internal DPI Cables on PowerFlex 700S Frame 3 and 4 Drives

Replacing the Power Supply

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

SynchLink Board for PowerFlex 700S Drives with Phase II Control

PowerFlex DC Stand-Alone Regulator (SAR) Switching Power Supply Circuit Board

Connecting the EN-4000 to DC Power

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

PowerFlex 755 Transition Section and Splicing Kit for Floormount Drives and CENTERLINE 2100 Motor Control Centers

PowerFlex DC Stand-Alone Regulator (SAR) Power Interface Circuit Board

Embedded EtherNet/IP Option Card for DriveLogix 5730 Controllers

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

Installation Instructions

Second Encoder Option Card for PowerFlex 700S Drives with Phase II Control

Allen-Bradley 1397 AC Tachometer Interface Card

Application Guide. Considerations for 32 Bit Integer Parameters in 16 Bit Processors. PowerFlex 700VC, PowerFlex 700S. Introduction.

Installation Instructions

AutoMax Network Communication Option Board for use with GV3000/SE AC Drives M/N 2AX3000

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

PCI 2 Axis Servo Card

Installation Instructions

Installation Instructions

Installation Instructions

PCI 2 Axis Servo Card

Removing and Replacing the Line Interface Module Internal Components

PowerFlex 700S and 700H Frame 13 Replacement Power Structures

PowerFlex 700S and 700H Frame 11 Replacement Power Structures

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Power Supply and Fan Module Installation

Memory Expansion for DriveLogix Controller

PowerFlex DC Stand-Alone Regulator (SAR) In-Rush Limiting Resistor

System Storage EXP3000 Rack Installation Instructions

1395 Node Adapter Board Troubleshooting

Digital ac/dc (24V) Input Module

Model 2380 Rack-Mount Kit

Solar Combiner Enclosure

Installation Instructions

InView Communication Modules

Allen-Bradley Motors

Programmable Controller IC697ACC721/724/744

Snap Server 4400 Power Supply

Installing the PSU for the S50 and S50N

Super Remote Meter Interface (RMI) Board For Use With GV3000/SE and VTAC 7 Drives

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Installation Instructions

PowerFlex 700 Power Jumpers

Kinetix 6200 and Kinetix 6500 IAM and AM Power Modules

MC 11 EB-2 Power supply cabinet with external bus, AC version

PowerFlex 750-Series Power Option Cabinets

Rack Installation Instructions

IBM. Rack Installation Instructions

Installation Instructions

PS/IO Circuit Board Retrofit

Perle MCR200 Installation Guide

Installing the Cisco SFS 3504 Server Switch

PM Series Power Meter

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Power Supply Installation

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

EBC Mini-ITX Chassis for High Power Consumption Applications Version: 1.0. Quick Installation Guide ABOUT COMPATIBLE SBC/COOLING KIT

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Installation Instructions

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

PanelView 600 Terminals

InView Firmware Update

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

Removal and Installation8

FOR SERVICE TECHNICIAN S USE ONLY

Allen-Bradley Drives

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

Replacing the SATA PCI Controller Card

Replacing or Upgrading DiskOnChip Memory

AEC Absolute Encoder Converter

Installation Instructions

Technovision Inc. CD-ROM Audio Sampler. Repair Manual

FLEX Ex Spring Clamp Terminal Base

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

Installation Data. The 1771 OB module can control the following output devices: dc motor starters indicators solenoids

InView Marquee Message Display

PV Rapid Shutdown device

Intel NUC Kit NUC6CAYS User Guide

ArmorPoint I/O Field Potential Distributor, Series A

Transcription:

Installation Instructions 1394 Fan Kit (Catalog Numbers 1394-FK10TS and -FK22TS) This publication provides installation instructions for the Allen-Bradley 1394 fan kit. The fan kit applies to the following 1394 GMC and GMC Turbo system modules listed in the table below. This 1394 Fan Kit Catalog Number: Applies to these 1394 System Modules: This 1394 Fan Kit Catalog Number: Applies to these 1394 System Modules: 1394C-SJT05-C 1394C-SJT22-C 1394C-SJT05-C-RL 1394C-SJT05-L 1394-FK22TS 1394C-SJT22-C-RL 1394C-SJT22-T 1394C-SJT05-L-RL 1394C-SJT22-T-RL 1394C-SJT05-T 1394-FK10TS 1394C-SJT05-T-RL 1394C-SJT10-C 1394C-SJT10-C-RL 1394C-SJT10-L 1394C-SJT10-L-RL 1394C-SJT10-T 1394C-SJT10-T-RL

2 1394 Fan Kit For additional 1394 installation, wiring, or system integration information, refer to the following publications: 1394 Digital AC Multi-Axis Motion Control System User Manual (publication 1394-5.0-MAY00). 1394 Digital AC Multi-Axis Motion Control System Document Update (publication 1394-DU005x-EN-P). To download this and other Rockwell Automation publications, go to www.rockwellautomation.com/literature. Introduction The 1394 fan kit is designed to provide additional cooling for the system module. The fan is attached on top of the system module chassis exterior and wired to 24V dc. You may need a volt meter and small flathead screw driver to install the fan. ATTENTION To avoid shock hazard or personal injury, assure that all power is removed from the system module before proceeding. This system may have multiple sources of power. More than one disconnect switch may be required to de-energize the system.

1394 Fan Kit 3 Installing the 1394 Fan Kit To install the 1394 fan kit: 1. Remove all input power to the drive. Allow five minutes for the DC bus to completely discharge before proceeding. ATTENTION This product contains stored energy devices. To avoid hazard of electrical shock, verify that all voltage on capacitors has been discharged before attempting to service, repair, or remove this unit. You should only attempt the procedures in this document if you are qualified to do so and are familiar with solid-state control equipment and the safety procedures in publication NFPA 70E. 2. Position fan kit over the system module vent slots by aligning the bracket flush with the panel (refer to Figure 1). Figure 1 Aligning the 1394 Fan Kit Over the System Module Fan wires Fan kit kw rating Align bracket flush with the panel and back of the system module. For use with 22 kw Modules Align bracket snap-locks in vent slots 5 and 12 on 22 kw system modules, 6 and 13 on 5/10 kw system modules (rear snap-lock hidden from view). 1 2 3 4 5 6 7 8 9 10 11 12 13 Align bracket tabs in vent slots 7 and 10 on 22 kw system modules, 8 and 11 on 5/10 kw system modules. 1394x-SJT22-x (22 kw) system module is shown

4 1394 Fan Kit IMPORTANT Verify the fan kit kw rating matches the system module kw rating. Mismatched fan kits will not align properly with the vent slots. 3. Press fan kit downward, with bracket tabs inserted between vent slots, until snap-locks click into place (refer to Figure 2). Figure 2 1394 Fan Kit Installed Over the System Module Fan wires Bracket flush with the panel and back of system module. For use with 22 kw Modules 1 2 3 4 5 6 7 8 9 10 11 12 13 1394x-SJT22-x (22 kw) system module is shown ATTENTION To avoid equipment damage, do not route the fan wiring under the bracket. Keep fan wiring out of the way while pressing fan and bracket down onto the system module. 4. Verify the fan wiring is not routed under the fan and bracket.

1394 Fan Kit 5 Wiring the 1394 Fan Kit The 1394 fan kit accepts only 24V dc, which can be supplied from the system module 24V dc (logic) power supply or separate 24V dc supply. IMPORTANT The 1394 fan kit accepts only 24V dc (within a range of 18.75-31.25V dc, 50/60 Hz). If your system module logic power supply is 24V ac, then a separate (customer-supplied) 24V dc must be used. To wire the 1394 fan kit: 1. Route fan kit wires down along the side of the system module and over to where the 24V dc power supply connections are made (refer to figures 3 and 4 for the location of the 1394 connector locations). Figure 3 Locating 24V dc Connections (5 and 10kW system modules) J1 1 2 24V dc Logic Power Connections (J1-1, and -2) 1394C-SJT05-x-xx and 1394C-SJT10-x-xx System Modules (bottom view)

6 1394 Fan Kit Figure 4 Locating 24V dc Connections (22kW system modules) 24V dc Logic Power Connections (W1 and W2) 1394C-SJT22-x-xx System Modules (front view) 2. Label and remove the 24V dc logic power wiring from the system module. 3. Determine the positive 24V dc supply wire and align the red wire from the fan kit to the +24V side. 4. Determine the negative 24V dc supply wire and align the black wire from the fan kit to the -24V side. IMPORTANT The desired direction of air flow is upward. If fan is wired backwards, air flow will be downward. 5. Insert and tighten the 24V dc supply wires (and fan wires) as described in the table below (system module polarity is not specified). System Module 24V dc Input Connections Torque Value 1394C-SJT05 and -SJT10 J1-1 and -2 0.56-0.62 N-m 1394C-SJT22 W1 and W2 (5.0-5.6 lb-in.)

1394 Fan Kit 7 6. Gently pull on each wire to make sure it does not come out of its terminal. Re-insert and tighten any loose wires. 7. Restore input power and verify drive operation.

363066-P01 Copyright 2005 Rockwell Automation. All rights reserved. Printed in USA.