Connecting a Cisco Reader Module

Similar documents
Connecting a Cisco Input Module

Connecting a Cisco Output Module

Identiv Connected Physical Access Manager 2.1 Installation Guide

FVT/FVR20D2I1C4E INSTALLATION AND OPERATION MANUAL

Identiv Connected Physical Access Manager 3.0 Installation Guide

Digital Keypad Introduction

MouldFlo Wiring Manual

MOULDFLO WIRING MANUAL

Single Door Standalone Access Control User Manual

TruPortal Dual Door Interface Module Quick Reference

IEI emerge MicroNode Install and Setup Guide. Contents

GLOSSARY. See also: Access point

4 Channel DMX Driver Instruction Manual

CM-110SK Standalone Keypad Installation Instructions

Analog Input and Output Options for Syringe Pumps

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

HI SEC Integrated Systems

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

C5S120 Installation and Connection Guide

UHF Reader Configuration Manual

GSV-1A4 M12/2 M12/2. Highlights

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

EA500. Installation Instructions Transponder

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

POWERWISE INDAC SETUP MANUAL

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

SRI-02 Speech Recognition Interface

8~14-Port Managed Ethernet Switch

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Installing Sentor. Hardware Installation

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

1%$6+2:7,0(*2/'(',7,21 1)/%/,7=*2/'(',7,21 &219(56,21.,7

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

SoundwebTM. Installation Guide

Quick Start Installation Guide

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

GV-EL124S Electric Strike

CA-A480-A Elevator Controller. Reference & Installation Manual

4.7 Expansion Module MAC00-FS1/FS4

Hardware Installation

Fingerprint Access Control Card Reader User s Manual

INDUSTRIAL POE SWITCH

MOTION COORDINATOR MC405 Quick Connection Guide

AHD 4CH HDD MOBILE DVR

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

PC Vision Wiring Guide

The INJ-102GT-24V PoE Injector is an advanced IEEE802.3at compliant device with intelligent detection that provided

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

IPassan Installation guide

EL-ST100 KEYPAD CONTROLLER

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

SP1 MP1 WP2 WP1. 125kHz reader models with the following prefixes: 13.56MHz reader models with the following prefixes:

Suprex RS-485 SPX-7500 Wired Reader-Extender

FSM-510G Series Ethernet Management Switch Quick Start Guide

ADDENDUM FOR 20, 27, & 28 OPTIONS

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Access Terminal IF-800

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

DOLXFD1000B. Waterproof Access Control/Reader

the Interactive Catalog

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Installation Instructions (KF-2000)

Quick Start Installation Guide

0.25m long cable directly out of the sensor. Blue laser line (405nm) for (semi-) transparent, red-hot glowing and organic materials

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

Omega 4K/UHD Scaler for HDBaseT and HDMI with USB

RTU560 Connections and Settings DIN Rail RTU 560CIG10

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

MS-5000: MiniStar Reader

MS-7000: SuperStar Reader

Quad-Relay Delay Switch (QRDS) User Manual (v1.0)

MS-3000 MicroStar Reader

MS-4000: ShootingStar Reader

Panoramic Fisheye IP Camera. Quick Installation Guide

HVG400. Installation Guide

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

INSTALLATION INSTRUCTION MANUAL

Waterproof. Keypad/Reader/Controller

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Note: the wiring of the dead-man buttons has been changed since October 2001.

Figure 36. Connecting the 24V/DC power supply

4.8 Expansion Module MAC00-FS1/FS4

BLU- CIF Interface Board

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

Operation manual For NG BIOSINGLE Version 1.1

Fingerprint Identification Proximity Reader. Quick Installation Guide

4 Connection and interface

TKL19 (RTUL19) Installation Manual. Tema1.0_L19_IM_1.0_EN Pagina 1 di 24

VIDI-AC-2CS Access Controller/ Reader

Transcription:

CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco Reader Module is attached to a Cisco Physical Access Gateway to provide additional connections for one or two doors, but does not include Ethernet connections for the IP network. Power is supplied using the 2-pin connector for 12 to 24 VDC external power. Figure 3-1 Cisco Reader Module 3-1

Package Contents Chapter 3 The Cisco Reader Module is connected to a required Cisco Physical Access Gateway using a CAN connection, as shown in Figure 3-2. Figure 3-2 Cisco Reader Module connected to the Cisco Physical Access Gateway Door and Related Hardware Ethernet V Cisco Access Gateway Layer2 Switch Cisco IP Network 271602 CAN connection Cisco Access Control Manager Door and Related Hardware Cisco Reader Module (Optional) Package Contents Each Cisco Reader Module includes the following: Six resistors (1K) for input supervision Two mounting brackets, with 4 screws for each bracket Regulatory compliance and safety information Quick start guide Connector plugs, including the following: Type Quantity 10 Pin 1 3 Pin 4 2 Pin 6 3-2

Chapter 3 Physical Overview and Port Description Physical Overview and Port Description Each Cisco Reader Module includes ports for connecting up to two doors and associated input and output devices, as shown in Figure 3-3 and Figure 3-4. Figure 3-3 Cisco Reader Module Ports and Connectors 9 8 7 1 2 6 4 5 3 2 187049 Figure 3-4 Cisco Reader Module Ports and Connectors: Top View 2 5 6 7 8 9 10 3 2 1 187038 3-3

Physical Overview and Port Description Chapter 3 The following items are shown in Figure 3-3 and Figure 3-4: Type Description 1 Power Two-pin connector for Voltage In (VIN) and Ground (GND) to connect a 12 to 24 VDC external power source. 2 CAN interfaces A 3-wire CAN bus is used to connect additional modules. Note Modules are connected using the CAN1 interface. The CAN2 interface is not supported in this release. 3 CAN terminator The CAN terminator switch is set to ON for the last device in a CAN wiring bus. This switch is set to set to OFF for all other devices in the CAN bus. 4 Serial Interface The RS-485 interface is not supported in this release. 5 Weigand Interface One 10-pin Weigand/clock and data reader interface. This interface can be configured as two 5-pin Weigand/clock and data interfaces for installations where a 5-pin interface is sufficient. 6 Input interfaces Three input interfaces used to sense the contact closure. Each input can be configured as supervised or unsupervised and can be configured to sense a Normally Open (NO) or Normally Closed (NC) contact. An unsupervised input senses a simple contact closure state, including Normal or Alarm. When connected to open contacts, the terminal voltage range is 4V to 5V. For closed contacts, the voltage range is 0V to 0.7V. A supervised input senses four contact states, including Normal, Alarm, Open and Short. These inputs require 1K End-Of-Line (EOL) termination resistors installed at the contacts (two resistors are included in the accessory kits for each Input port). 7 Output interfaces Three Form C (5A @ 30V) relay output interfaces. Each output can be configured as either Normally Closed (NC) or Normally Open (NO). C & NO connection: The relay is normally open. The circuit is closed when triggered. C & NC connection: The relay is normally closed. The circuit is opened when triggered. Note Common (C) is always used, and either NC or NO is used to complete the connection. 8 PF Power fail input: an unsupervised input that raises a power fail alarm when the circuit is open. Can be configured as an additional unsupervised port. An unsupervised input indicates only normal or alarm. The corresponding LED is red when circuit is open (when no input is connected). 9 TM Tamper input: an unsupervised input that raises a tamper alarm when the circuit is open. Can be configured as an additional unsupervised port. An unsupervised input indicates only normal or alarm. The corresponding LED is red when circuit is open (when no input is connected). 3-4

Chapter 3 Installing the Cisco Reader Module Status LEDs Table 3-1 describes the Gateway module status LEDs: Table 3-1 Gateway LEDs Status Input Port LEDs OFF GREEN BLINKING GREEN BLINKING RED RED Output Port LEDs Off Solid Green Blinking Green Description Input is not configured Input is configured and in normal state Input is configured, and is receiving and alarm or other data. Input is configured, short Input is configured, open Output not configured Output configured and in default state Output configured and active Installing the Cisco Reader Module Installing the Cisco Reader Module is similar to installing the Gateway, except for the following: There are no Ethernet ports. The Cisco Reader Module is not directly connected to the IP network, and is not directly configured. The Cisco Reader Module does not support Power over Ethernet (PoE). The device is connected to a DC power source. The Cisco Reader Module must be terminated if it is the last device in a CAN wiring bus. See CAN Bus Connections for Optional Modules, page 1-8 for more information. Before You Begin Before you install a Cisco Reader Module, verify the following: Verify that the module has access to a power source. See Power Options and Requirements, page 1-10 for more information. Verify that you have the necessary mounting brackets or other hardware. See Mounting a Gateway or Optional Module, page 1-11. Installation Procedure To install the Cisco Reader Module, perform the following procedure: Step 1 Mount the module to a wall. See Mounting a Gateway or Optional Module, page 1-11 for more information. 3-5

Installing the Cisco Reader Module Chapter 3 Step 2 Connect the module to the DC power source: a. Insert a two-pin connector plug into the DC power port (Figure 3-5) b. Connect the Voltage In (VIN) and ground (GND) wires. See Power Options and Requirements, page 1-10 for more information. Figure 3-5 Power Connection: for the Cisco Reader Module 271601 2 1 The following items are shown in Figure 3-5: Configuration 1 DC power GND (ground) 2 DC power Voltage In (VIN) Description Connects the DC ground wire to the module. Connects the DC Voltage In (VIN) wire to the module. Step 3 Connect the module to the Gateway using a CAN bus: a. Insert a three-pin connector plug into the CAN1 port, as shown in Figure 3-6. b. Connect the CAN wires to the CAN bus, as shown in Figure 3-7 c. Turn the CAN terminator ON if the device is the last device in a CAN wiring bus. Note The CAN terminator switch in included on the Reader, Input and Output modules only (the Gateway is always the first device in the CAN bus). Set the terminator switch to OFF for all other modules in the CAN bus. Note The CAN2 interface is not supported in this release. 3-6

Chapter 3 Installing the Cisco Reader Module See Optional Expansion Modules, page 1-6 for more information: Figure 3-6 CAN1 Connections: Cisco Physical Access Gateway and Reader Module 271600 4 1 2 3 The following items are shown in Figure 3-6: Configuration Description 1 CAN+ Connects to the positive terminal of the CAN bus. 2 CAN- Connects to the negative terminal of the CAN bus. 3 Shield Connects to GND and/or Shield. 3 CAN Terminator Turn the terminator ON if the device is the last device in a CAN wiring bus. Figure 3-7 CAN Bus Wiring CAN+ Sheild CAN- Gateway Module Reader Module Input Module Output Module 271589 3-7

Installing the Cisco Reader Module Chapter 3 Step 4 Connect one or two door reader devices to the Weigand interface using one of the following configurations: Connect a single door reader using all 10 Weigand interface pins. Connect one or two door readers using 5-pin Weigand interface connections (for installations where a 5-pin interface is sufficient). Figure 3-8 shows the location of the Weigand interface connections. Table 3-2 describes the connections for 10-pin and 5-pin reader interface connections. The wire connectors from the reader device are shown in parentheses. If attaching a second reader, use the alternative connections shown in the column on the far right. Figure 3-8 Weigand Interface on the Gateway and Reader Modules 10 9 8 7 6 5 4 3 2 1 271603 Table 3-2 Weigand Reader Wiring for 10 or 5 Pin Connections Chassis Label Description One Reader 10 Wire Connection First Reader in a 5 Wire Connection Second Reader in a 5 Wire Connection PWR +12v PWR (red) 1 PWR (red) PWR (red) GND Ground GND (black) GND (black) GND (black) D0 Data 0 D0 (green) D0 (green) ---------- D1/CLCK Data 1 D1/CLCK (white) D1/CLCK (white) ---------- DRTN Shield DRTN (shield) DRTN (shield) DRTN (shield) GRN Output 2 GRN (orange) GRN (orange) ---------- 3-8

Chapter 3 Installing the Cisco Reader Module Table 3-2 Weigand Reader Wiring for 10 or 5 Pin Connections (continued) Chassis Label Description RED Output RED (brown) ---------- 3 GRN (orange) BPR Output BPR (yellow) ---------- ---------- (Beeper) HCRD Hold HCRD (blue) ---------- D1/CLCK (white) Control CP Card Present CP (purple) ---------- D0 (green) 1. Wire colors are shown in parentheses. One Reader 10 Wire Connection First Reader in a 5 Wire Connection Second Reader in a 5 Wire Connection 2. Outputs show the LED color and reader wire color (in parentheses). For example, GRN (orange) supports a green LED. Attach the orange wire from the reader device. 3. ---------- means the wire slot is not used. Step 5 Connect input devices to the module: a. Insert two-pin connector plugs into the input ports (Figure 3-10). b. (Optional, for supervised input connections only). Install two End-Of-Line (EOL) 1K termination resistors in each supervised input interface (one terminator in each connector). Figure 3-9 shows the terminator installation for a Normally Closed (NC) and Normally Open (NO) input connection. Figure 3-9 Input Connections: Cisco Physical Access Gateway and Reader Module 1K,, 1% 1K,, 1% NC 1K,, 1% 1K,, 1% NO 187838 c. Connect the wires from the input devices (Figure 3-10). Note Each of the input connections can be configured as supervised or unsupervised. The tamper and power fail inputs can be configured as additional unsupervised ports. A supervised input supports four states: normal, alarm, open and short. An unsupervised input indicates only normal or alarm. 3-9

Installing the Cisco Reader Module Chapter 3 Figure 3-10 Input Connections: Cisco Physical Access Gateway and Reader Module 271592 3 4 1 2 1 2 1 2 The following items are shown in Figure 3-10: Configuration Description 1 Positive Input Positive connection to an Input device. Connections 2 Ground Input Ground connection to an Input device. Connections 3 TM Tamper input: an unsupervised input that raises a tamper alarm when the circuit is open. Can be configured as a general input device using the Cisco Physical Access Manager. The corresponding LED is red when circuit is open (when no input is connected). 4 PF Power fail input: an unsupervised input that raises a power fail alarm when the circuit is open. Can be configured as an additional unsupervised port. The corresponding LED is red when circuit is open (when no input is connected). Step 6 Connect output devices to the module: a. Insert three-pin connector plugs into the output ports (Figure 3-11). b. Connect the wires from the output devices. Common (C) is always used, and either NC or NO is used to complete the connection. 3-10

Chapter 3 Installing the Cisco Reader Module If the relay is normally open, use the C & NO connections. The circuit is closed when triggered. If the relay is normally closed, use the C & NC connections. The circuit is opened when triggered. Figure 3-11 Output Connections: Cisco Physical Access Gateway and Reader Module 271593 1 2 3 1 2 3 1 2 3 The following items are shown in Figure 3-11: 1 Normally Open (N.O.) connection 3 Normally Closed (N.O.) connection 2 C (Common) Step 7 See the User Guide for Cisco Physical Access Manager for information to configure the module ports. 3-11

Installing the Cisco Reader Module Chapter 3 3-12