Usage of the digital inputs of SENTRON PACs

Similar documents
7KT/7KM PAC Measuring Devices

Power Management System. Measuring Devices for Power Distribution

Reliable and precise control over electrical systems and power

Easy Networking for Power Monitoring. network based MONITORING SOLUTIONS

Acti 9 iem3000 Series Energy Meters Functions and characteristics

Power Management System. Multifunction Measuring Instruments

Acti 9 iem3000 Series Energy Meters Functions and characteristics

FAQ collection for PAC3100/3200/4200

3VA molded case circuit breaker. communication SENTRON. Protection devices 3VA molded case circuit breaker communication.

Quick Start powermanager SENTRON. Software Quick Start powermanager. Introduction. Installation. Starting the project 3

Power Management. Reliable and Precise Overview Over Electrical Characteristics and Power. Answers for industry. SENTRON PAC Power Monitoring Devices

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

3VA molded case circuit breaker up to 1600A. Frei verwendbar Siemens AG 2018

7KT/7KM PAC measuring devices

3VA Molded Case Circuit Breakers

Documentation. M-Bus 130-mbx

Power Meter PowerMonitor 500

E N E R G Y M E T E R S

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

with Backlight Graphic LCD Screen

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Savings Potential through Transparent Energy Flows

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

SENTRON SIVACON ALPHA

Smart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt

MIC-2 Multi-instrument DATA SHEET

MDC-20. Maximum Demand predictive Control. Description

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

MID approval no. DE-08-MI004-PTB004 Date of release

Uniform parameterisation, operation, and monitoring of intelligent switchboards

MODULAR CIRCUIT MONITORING SYSTEM

Power monitoring made simple Easy safe cost-efficient

DIRIS A-30 Multifunction power metering & monitoring device - PMD

ANLEITUNG / MANUAL EMU ALLROUNDER EMU PROFESSIONAL. Quality that counts. Made in Switzerland

Smart Energy & Power Quality Solutions. ProData data logger. Data collection and recording

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

1.2. All new meters will be one of the following meter forms: 2S for single-phase, and 9S for multi-phase.

SECTION ( ) LIGHTING CONTROL PANELBOARD

AVReporter Schneider Electric M221 WAGES PLC Configuration Guide

Specification for Smart Panels : Energy management system to monitor, control and maintain building installations

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

PQM - Power Quality Monitoring

FX1N-2EYT-BD Output Expansion Board

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

PowerLogic power-monitoring units. iem3000 Series. Technical data sheet

Simple Introduction into Energy Management with WinCC WinCC Application Description December 2011 Applications & Tools Answers for industry.

Smart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

PQM - Power Quality Monitoring

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

A2000 Multifunctional Power Meter

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Communications guide. Line Distance Protection System * F1* GE Digital Energy. Title page

HMI software. gems 3100 Multi-Channel Power Meter

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

Equipment Operation & Maintenance

Open Smart Metering Gateway EWIO-9180-M. Energy consumption monitoring and energy monitoring in buildings, on machines, installations and systems

FSa0626 Project Notes

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

Compact NSX communication

EngyVolt RV12 and RV15

DIGITAL METERING INSTRUMENTS DMG SERIES

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

SENTRON 3VL Molded Case Circuit Breakers

FANCOIL CONTROLLER UNIT TC17B01KNX. Product Handbook

SIPROTEC 5 Application Note

A1700 CT Metering. The Power to Change...

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Increase transparency and process quality Total Energy Monitoring across all levels of production Let s connect. Measuring and monitoring systems

Communicating Submeter Data Via BACnet

9.3. Metering Devices, Protective Relays, Software and Connectivity

Power analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B A) MEASURING EQUIPMENT

SENTRON. Power Monitoring Device SENTRON PAC3200. Introduction. Safety instructions 2. Description 3. Operation planning 4.

USER S MANUAL. Gateway DLMS-MODBUS for ITRON/ACTARIS SL7000 with RS232 P/N: GW-DLMS-232-SL7. Edition 2.0

PowerLogic ION7550 / ION7650 Hardware Lockable Meter

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

Andover ContinuumTM Infinet II

MIC-2 MKII I/O module user s manual

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

Switch Disconnectors, Main and EMERGENCY-STOP Switches

MIC-2 MKII, Multi-instrument DATA SHEET

Estates & Facilities Utilities Meters - Performance Specification

Micro Application Example

Andover ContinuumTM. b3850 Series Terminal Controllers

Impulse switching module

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

PDU Solutions. PDU Solutions

Cover sheet. Application Operations Diary. WinCC Flexible 2008 SP1. Application Description June Applications & Tools. Answers for industry.

Smart energy meter. Benefits and Features. User Manual Revision English. 103EM series

PADPULS2 M-BUS Pulse Input Modules

Innovative features and solutions for SIVACON S8 siemens.com/sivacon-s8

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

BACnet. b3810 Series Local Controllers

Transcription:

1 QUESTION Where and how can I use the digital inputs of the SENTRON PAC meters? What are the guidelines and restrictions? 2 ANSWER The digital inputs (DIs) of the SENTRON PACs can be separated into Dry contacts or passive digital inputs (wiring with 24V DC external auxiliary power supply) Wet contacts or active digital inputs with internal power supply (wiring optionally without external auxiliary power supply) Number of passive Number of active MLFB digital inputs digital inputs SENTORN PAC3100 --- 2 7KM3133-0BA00-3AA0 SENTRON PAC3200 1 --- 7KM2112-0BA00-2AA0 7KM2112-0BA00-3AA0 7KM2111-1BA00-3AA0 2 --- 7KM4212-0BA00-2AA0 7KM4212-0BA00-3AA0 SENTRON Expansion Module PAC 4DI/2DO --- 4 7KM9200-0AB00-0AA0 Table 1: Number and type of digital inputs There are many possible applications for the digital inputs of SENTRON PACs. This FAQ will describe the most important ones in a short overview: State monitoring of connected signal encoders. Example: Open or closed status of a breaker Universal counter for example for gas, water, electricity or heat by way of pulse inputs Control input for switching between on-peak and off-peak tariff Synchronization of demand periods Time synchronization via top-of-minute impulse Control input for the process energy counters and for the process operating hours counters o o o Start / stop Reset Copy and reset page 1

2.1 STATE MONITORING 2.1.1 OVERVIEW SENTRON PACS can monitor the state of other devices of the low-voltage power distribution system and communicate it to a higher-level system. This is a great benefit for the user, because he gets a comprehensive overview of the low-voltage power distribution system and in case of a defect he will be able to find out the location of the defect faster. Some examples for devices that can be monitored via the digital inputs of SENTRON PACs are: Circuit breakers with aux. contacts (e.g. 3WL, 3VL) Switch disconnect strips with aux. contacts (e.g. 3NJ6) Fuse-switch disconnectors with aux. contacts (e.g. 3NP1) In addition to that the signal at the integrated inputs of can be used for Boolean logic functions for example to control an output. Figure 1 shows a possible set-up for monitoring the state of five SENTRON 3VL circuit breakers via a SENTRON PAC4200 with two expansion modules PAC 4DI/2DO. Each of the five circuit breakers provides the two signals on/off and tripped/not tripped to the digital inputs of the PAC4200. The visualization of the PAC4200 measuring values and the states of the circuit breakers is done directly at the PAC4200 device and additionally in the PC application SENTRON powermanager: SENTRON powermanager Ethernet network PAC4200 with two expansion modules 4DI/2DO Digital inputs 3VL Figure 1: for state monitoring of five 3VL circuit breakers The outputs of four circuit breakers can be connected directly without any external auxiliary power supply to the eight active inputs of the two expansion modules PAC 4DI/2DO.The fifth circuit breaker may be connected to the two integrated digital inputs. The internal inputs are passive inputs and require an external power supply of 24V DC. page 2

2.1.2 SUPPORTED DEVICES The following power monitoring devices support the application state monitoring from contact inputs such as aux. contacts from a breaker: SENTRON PAC3100 SENTRON PAC3200 with SENTRON expansion module PAC 4DI/2DO 2.2 UNIVERSAL COUNTERS 2.2.1 OVERVIEW The digital inputs of the SENTRON PACs can be used as counter inputs for State changes of for example other devices of the low-voltage power supply system (see chapter 2.1) Energy pulses (KY / KYZ pulses) of other energy meters Figure 2 shows the usage of a as a master device for logging the energy counted by other energy meters: Power meter (active-, reactive- and apparent energy) Water meter Compressed air / steam meter Gas meter page 3

3~ electric meter 2 x PAC 4DI/2DO 1~ electric meter gas meter 3~ power meter kwh / kvarh water flow meter compr.-air/ steam meter Figure 2: PAC4200 for logging the energy of other energy meters The consumptions of the different types of energy are transmitted via KY / KYZ pulses to the storing them in individual counters. For displaying the correct energy consumption it is possible to configure both, the unit and the weight (e.g. 10 pulses per kwh) independently for each of these counters. The energy consumption from multiple counters can also be summed even if the unit of measure is different 2.2.2 SUPPORTED DEVICES The following power monitoring devices support the application universal counter for state changes: SENTRON PAC3200 with SENTRON expansion module PAC 4DI/2DO The following power monitoring devices support the application universal counter for energy: SENTRON PAC3200 (units for electrical energy only) with SENTRON expansion module PAC 4DI/2DO page 4

2.3 SWITCHING BETWEEN ON-PEAK AND OFF-PEAK TARIFF 2.3.1 OVERVIEW One main application for the power monitoring devices SENTRON PAC is to meter electrical energy. This happens with some internal counters and optionally for the devices being described in chapter 2.2. SENTRON PAC3200 and provide separate on-peak and off-peak counters for the internally metered energy. The tariff switch between on-peak and off-peak is done by way of a communication interface or via an external signal at a digital input. 2.3.2 SUPPORTED DEVICES The following power monitoring devices support the application on-peak / off-peak switching: SENTRON PAC3200 with SENTRON expansion module PAC 4DI/2DO 2.4 SYNCHRONIZATION OF THE DEMAND PERIODS 2.4.1 OVERVIEW Usually the electricity bill for companies with high power consumption consists of two major positions Demand rate (depends on the maximum demand value) Energy rate (depends on the energy consumption) Consequently it is important for the negotiations with the utilities about the rates for future periods to have a good estimation for both, the maximum demand value and the energy consumption for the future period. For these negotiations it is also important to know that a fine may become due if the real maximum demand value is higher than the one being part of the energy delivery contract. To be aware of the demand values it is necessary that the periods for gathering these values (usually 15 or 30 minutes) are identical for SENTRON PACs and for the energy meters of the utility. This synchronization of the demand periods (start of the periods) can be done by way of communication, time or digital inputs in the SENTRON PACs. page 5

2.4.2 SUPPORTED DEVICES The following power monitoring devices support the application synchronization of demand periods using digital inputs: SENTRON PAC3200 with SENTRON expansion module PAC 4DI/2DO 2.5 TIME SYNCHRONIZATION VIA TOP-OF-MINUTE PULSE 2.5.1 OVERVIEW has an internal clock proving time-stamps for Maximum and minimum values of measuring variables Entries in the event memory Entries in the demand memory For these applications it is required that the provides the exact time. One possibility to synchronize the time of the with an external clock master is a top-of-minute pulse. This pulse, being sent at the start of a minute to a digital input of the, causes a reset of the seconds to zero. The minutes are rounded correctly depending on the device time before the device received a top-of-minute pulse: Example 1: The current device time is 12:06:51 and the receives a top-of-minute pulse. Consequently the device time is set to 12:07:00. Example 2: The current device time is 12:07:11 and the receives a top-of-minute pulse. Consequently the device time is set to 12:07:00. page 6

2.5.2 SUPPORTED DEVICES The following power monitoring devices support the application time synchronization using top-of-minute pulse: with SENTRON expansion module PAC 4DI/2DO 2.6 CONTROL INPUT FOR PROCESS COUNTERS 2.6.1 OVERVIEW For a lot of manufacturing processes it is important to meter the power consumption either per piece or for each production-process or sub-process. The process counters of the are suited very well for this task. They register the consumption of active, reactive and apparent energy separately and can be started and stopped reset copied to a intermediate buffer and reset by way of a digital input. The energy consumption per piece or for each production-process or sub-process is a good base for a source-related cost allocation and optimization of the energy consumption and thus a reduction of the energy costs 2.6.2 SUPPORTED DEVICES The following power monitoring devices support the application control input for process counters: with SENTRON expansion module PAC 4DI/2DO page 7

2.7 RESTRICTIONS As shown above, the digital inputs of the power monitoring devices SENTRON PAC can be used for many different applications. However due to its functional principles it is not allowed to use a mixture of active and passive digital inputs of SENTRON PACs in series or in parallel. It is possible to have either several passive inputs in parallel or several active inputs in parallel separately. Number of passive digital inputs Number of active digital inputs SENTORN PAC3100 --- 2 SENTRON PAC3200 1 --- 2 --- SENTRON Expansion Module PAC 4DI/2DO --- 4 Table 2: Number and types of the digital inputs The combinations listed below are valid examples of switching to on and off peak tariff from a common signal for multiple SENTRON PAC meters: Combination 1: SENTRON PAC3200 and / or (with or without expansion module PAC 4DI/2DO) Exclusive usage of the integrated digital inputs Digital inputs of the expansion module PAC 4DI/2DO must not be used Combination 2: with expansion module PAC 4DI/2DO Exclusive usage of the digital inputs of the expansion module PAC 4DI/2DO The figures below show some supported and unsupported examples for the connection and combination of dry and self-wetting digital inputs: page 8

2.7.1 CONNECTION EXAMPLES: INTERNAL DIGITAL INPUTS OF Figure 3: Connection example for the internal digital inputs of PAC4200 (DIC = +) Figure 4: Connection example for the internal digital inputs of PAC4200 (DIC = -) Figure 5: Unsupported connection example for the internal digital inputs of PAC4200 page 9

2.7.2 CONNECTION EXAMPLES: DIGITAL INPUTS OF EXPANSION MODUL PAC 4DI/2DO Figure 6: Connection example for the expansion module PAC 4DI/2DO Figure 7: Connection example for the expansion module PAC 4DI/2DO (DIC = -) Figure 8: Unsupported connection example for the expansion module PAC 4DI/2DO (DIC = +) page 10

2.7.3 CONNECTION EXAMPLES: COMBINATIONS Figure 9: Unsupported combination of active and passive digital inputs Figure 10: Unsupported combination of active and passive digital inputs (DIC = +) Figure 11: Unsupported combination of active and passive digital inputs (DIC = -) page 11

Figure 12: Unsupported combination of active and passive digital inputs (DIC = +) Figure 13: Combination of active and passive digital inputs (DIC = -) page 12