For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

Similar documents
INSTEON SwitchLinc 1000W. INSTEON Dimmer Switch. For models: SwitchLinc V2 Dimmer 1000W

INSTEON KeypadLinc TM Dimmer (Rev 1.5+) INSTEON Keypad Dimmer. For models: KeypadLinc Dimmer 8-Button

INSTEON ToggleLinc. INSTEON Dimmer Switch. For models:

Fluorescent. Remote Control Switch. For Models #2385W and 2385I (and Remote Control Switch Model #2382W/I)

Installation Instructions

SwitchLinc 2-Way TM. Remote Control Switch and Transmitter

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

Installation Instructions

INSTEON. INSTEON Inline Relay Module. For models: #2475S In-LineLinc Relay 400W

Before you get started

KeypadLinc TM. Now Includes BoosterLinc Signal Boosting

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal rotary dimmer LED

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11

Bluetooth Ceiling Fan Control with App Owner's Manual

THE CTB08D LIGHT CONTOLLER

KeypadLinc TM. Wall-Mounted X10 Controller Wall-Mounted X10 Controller with Integrated Dimmer

AuroRa Security Installation Guide

SAVE THESE INSTRUCTIONS

Z-Wave enabled 3-Way 15 Amp In-Wall Switch User Manual For Model HA18WD

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

CasétaTM PD-5WS-DV. SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: Receiving Device

Stanza. Wireless Lighting Control

Product and functional description

The LED display (1) turns green when the load is switched on.

Keypad Dimmer Owner s Manual

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

LampLinc TM. 2-Way Lamp Module with Scenes

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Control Your World. Lighting Control System

SwitchLinc Dimmer INSTEON Remote Control Dimmer Switch Owner s Manual (rev 5.0+) (#2476Dxxx)

NI PXIe-1062Q Power Supply Shuttle

Dimmers with Neutral Wire for Halogen, Incandescent, ELV, or Interfaces

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Mini Energy Dimmer MH-P210

In-LineLinc Relay Owners Manual INSTEON In-LineLinc On/Off, Dual-Band (#2475SDB)

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

Product and functional description

HAIKU WALL CONTROL KIT

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Product Features. LED Light. LED Indicator light. Camera Lens. Microphone. IR LEDs. PIR Sensor. Reset button. Micro-SD card slot. Speaker.

KeypadLinc On/Off Owner s Manual INSTEON 6-Button Scene Control Keypad, Dual-Band (#2487S)

picture 1: Device components

LITETOUCH HYBRID WALL BOX DIMMER INSTALLATION INSTRUCTIONS

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Model HM-535 Power Supply Installation and Service Instructions

xbrick Full-Colour 16 3W LED floodlight user manual

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Weathersafe Vision. Installation & Operating Instructions

Caseta Wireless switch, 5A lighting or 3A fan, 120/277V in ivory. 600 W incandescent/halogen/140 W CFL/LED

Rack Mount Power Supplies

Self-Adjusting Ultrasonic Wall Switch Sensor

Octostrip ORDERCODE 42220

Micro Smart Dimmer 2E manual. In-Wall Electrical Installation Instructions:

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Lighting Control in the palm of your hand.

Voice & Data QuickPort Wallplate Inserts 1.58 (40.1) Add 1.81" (46.0mm) for each gang in multi-gang wallplates

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

SAVE THESE INSTRUCTIONS

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

FLEX BEAM V8. User Manual Please read the instruction carefully before use

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Elapsed Timer Control Panel

OT EASY 60 II. LED control unit Operating instructions

Power Supply and Fan Module Installation

ZenNet Installation Guide:

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

VBAR 270. User Manual. Version 1.2

Replacing the Power Supply

RadioRA 2 Hybrid Keypads

ECM-1220 User s Manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

X-3 LED. Owner s Manual ROBOHEAD

CM/CS SERIES. Compact 100V amplifiers. Item ref: UK, UK, UK User Manual. CM/CS Series User Manual

Installation Instructions

PS/IO Circuit Board Retrofit

Instruction Manual HPH-8

INSTALLATION & SETUP GUIDE FOR SINGLE POLE & 3-WAY CONFIGURATIONS IN WALL SOLUTIONS

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

INSTALLATION MANUAL For authorized service personnel only.

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

Installation and Operations Manual. Electronic copies available at (Rev_ )

IIM Warwick Court. Williamsburg VA REV 5

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Owner's Manual. Carrier TOSH BA REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit TCB-AX21 UL

CW-WW LEDWash USER MANUAL

Pro Series LED Controllers Part numbers: pro-4-in-1-receiver, dim-pro-knob-us-w dim-pro-knob-wa, dim-pro-knob-rgb, rgbw-pro-touch, rgb-pro-remote

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

Congratulations on your purchase!! 5-ft. KD Magnesium Animated Nutcracker with Remote Control Instructions

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

NI PXI-1042 Series Power Supply Shuttle

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

COB100/200W 2in1/3in1 led Par Light

Product and functional description

PRODUCT MANUAL Duet DMX & Wireless RGB-W Controller

Transcription:

SwitchLinc Lite Remote Control Dimmer Switch Owner s Manual For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

CONGRATULATIONS! You ve just purchased the highest quality powerline-controllable wall switch available. SwitchLinc Lite gives you remote control of lighting and inductive loads, and can be controlled locally at the switch or remotely from a powerline transmitter. SwitchLinc Lite is easily installed and programmed. It installs (connects to home wiring) just like a regular light switch. This makes it ideal for retrofits and easy for new homes, with no special training required to install it. KEY FEATURES Status LED/Nightlight Wires in just like a standard wall switch* Brightness LED Bar Very easy to program High quality mechanicals with years of field testing True rocker action (top = on/bright, bottom = off/dim) LED Bar shows brightness of circuit Status LED shows powerline activity and is a nightlight Set Button facilitates programming * Requires a neutral connection SWITCHLINC LITE MODELS Model # 2384W/I - 600 Watt Master (White or Ivory) Model # 1135W/I - Slave Switch for 3-Way, 4-Way, & Up (White or Ivory) (Note: 1135 does not have LED brightness bar.) Set Button OPERATIONS Input at Switch Tap top of rocker (when light is off) Tap top of rocker (when light is on) Double-tap top of rocker Press & hold top of rocker Tap bottom of rocker Double-tap bottom of rocker Press & hold bottom of rocker LED Status LED/Nightlight Brightness LED Bar (8 LEDs) Output at Bulb Light ramps up to preset ON-level Light ramps up to full brightness Light ramps fast to full brightness Light brightens until rocker is released Light ramps down to OFF Light ramps fast to OFF Light dims until rocker is released Operation Blinks when valid X-10 signals are received Illuminated LED represents current brightness setting (Top = Brightest; Bottom = Dimmest) CAUTION!! Read and understand these instructions before installing. This device is intended for installation in accordance with the National Electrical Code and local regulations. To reduce the risk of overheating and possible damage to other equipment, do not install a SwitchLinc to control a receptacle or fluorescent lighting fixture. For indoor use only. Connect only copper or copper-clad wire to this device. Before installing control, disconnect power at circuit breaker or remove fuse to avoid shock or damage to the control. It is recommended that a qualified electrician perform this installation. Retain these instructions for future reference. 2

PREPARATION Before installing SwitchLinc Lite, please familiarize yourself with the following and take the necessary precautions listed here: Be sure that power to the load being controlled has been disconnected by removing the fuse or turning the circuit breaker off. Installing SwitchLinc Lite with the power on may expose you to dangerous voltages and may damage the product. Refer to the SwitchLinc Wiring Diagrams below to determine the wire colors of the connections to SwitchLinc Lite. Note: All SwitchLinc Lites require a neutral connection. Wiring for 3-way, 4-way, & up switch circuits follow conventional (standard, non-remote) wiring practice (plus the requirement for a neutral). Wiring slave switches requires the Line () wire be accessible and be on the same 110V leg of the house wiring. The Grey wire on the slave switch is to be connected to NEUTRALONLY. If neutral is not available, cap the Grey wire (which simply causes the LEDnot to function). SwitchLinc Lite may feel warm during operation. The amount of heat generated is within U.L. approved limits and poses no hazards. To minimize heat build-up, ensure that the area surrounding the rear of the SwitchLinc Lite has adequate ventilation (i.e., clear away excess insulation). Installation should be performed only by a qualified electrician, or by a homeowner who is familiar and comfortable with electrical circuitry. Follow all routine safety precautions. INSTALLATION 1. Remove the power from the existing switch/device. 2. Remove the faceplate from the existing switch/device. 3. Unscrew and pull the device out of the wallbox. 4. Disconnect the wires from the device. 5. Using a wire tester or voltmeter, identify and mark "Hot",,, and Traveler (if applicable) wires that were connected to the device. 6. Before making any connections to SwitchLinc Lite, FIRMLY PRESS SWITCHLINC LITE S ROCKER BOTTOM UNTILYOU HEAR ACLICK. A System Off sticker will be exposed on the top of the rocker. 7. Orient SwitchLinc Lite so the LED is at the top, and make connections according to the Switch- Linc Wiring Diagram below. Wire slave switches according to the SwitchLinc Multi-Way Wiring Diagram on page 4. Main Panel SwitchLinc Wiring Diagram 120VAC Line cap this lead Yellow Red Light Fixture (s) Load White 3 SwitchLinc 2-Way Lite (Model (Model 1181 2384) or 1182)

Main Panel SwitchLinc Multi-Way Wiring Diagram 120VAC Line Yellow Yellow Red Light Fixture (s) Load Grey Grey White Optional Slave Switches (Model 1135) SwitchLinc 2-Way Lite (Model (Model 11812384) or 1182) Note: When installing multiple SwitchLincs in a J-box, or many on the same circuit breaker, please see specifications at the end of this manual for limitations and recommendations. 8. After all connections have been made, ensure that all wire connectors are firmly attached and that there is no exposed copper. 9. Gently place the wires and switch into the wallbox (with LED at top of device) and screw into place. 10. Before installing the faceplate, restore power to the circuit, and firmly press SwitchLinc Lite s rocker top until the switch snaps out of System Off position. 11. After testing SwitchLinc Lite for proper operation (as described on page 2), install the faceplate. PROGRAMMING Setting the Primary Address Each SwitchLinc Lite requires a primary X-10 address to operate (ships with A1 from the factory; up to 256 addresses can be programmed with Housecodes A-P and Unit Codes 1-16). Please note that the following Housecode and Unit Code combinations should not be assigned as primary addresses or scene addresses, because they are reserved for programming: M16, N16, O16, and P16 1. Using the tip of a very small screwdriver, press and hold the small Set Button in the middle of the righthand side of SwitchLinc Lite (see diagram on page 2) for approximately 5 seconds, until the brightness LED flashes (and the light goes to 100% brightness). When you release the Set Button, the nightlight LED will flash. 2. Within 30 seconds, transmit the desired primary address (housecode and unit code) from any transmitter (e.g., TouchLinc). The light will blink and the nightlight LED will stop flashing. Setting the Ramp Rate (Optional) The Ramp Rate is the rate at which SwitchLinc Lite brings the brightness of the light up or down when the switch is turned on locally or receives a powerline carrier (X-10) ON-command to its primary address. The Ramp Rate is adjustable. The factory default is about 3 seconds. If you wish to change the ramp rate, follow the instructions below. 4

1. Press and hold the rocker to adjust the Brightness LED level to correspond to the the desired ramp rate (brighter = faster) according to the following table. Brightness LED Level Ramp Rate in Seconds 8 0.1 7 0.2 6 0.3 5 0.5 4 2.0 3 4.5 2 6.5 1 8.5 NO LED 9.0 2. Tap the Set Button TWICE. The light will blink. Setting the ON-Level (Optional) The ON-Level is the default brightness level to which SwitchLinc Lite will adjust the light when the switch is turned on locally or receives a powerline carrier (X-10) ON-command to its primary address. The factory default is 100%. You can set the ON-Level to a fixed brightness level or to resume its previous brightness level. Setting a fixed brightness level: 1. Adjust the brightness of the light to the desired level by pressing and holding SwitchLinc s rocker. 2. Tap the Set Button ONCE. The light will blink. Setting resume dim: 1. Turn the light off. 2. Tap the Set Button ONCE. FACTORY RESET (TO DEFAULT SETTINGS) 1. Firmly press the bottom of the SwitchLinc Lite rocker until you hear a loud click. A System Off sticker will be exposed on the top of the rocker. This completely removes the power from the lighting circuit being controlled by the SwitchLinc Lite. 2. Press and hold the Set Button. 3. While continuing to hold the Set Button, press the top of the SwitchLinc rocker (as if to turn the switch on). 4. Release the Set Button. 5. WAIT approximately 25 seconds until the Nightlight LED illuminates before using the switch (SwitchLinc is rewriting all options to be as they were when they shipped from the factory). 5

SETTING GLOBAL (HOUSE-WIDE) OPTIONS Disable Program (Prevents accidental programming of SwitchLinc settings for all SwitchLincs in the home) Transmit the following PLC sequence: M16, O16, P16, N16, P16 (Re-)Enable Program (default) Transmit the following PLC sequence: N16, M16, O16, P16, P16 POWER RESTORE SwitchLinc Lite will return the lighting circuit being controlled to its last brightness level when power is restored after a power outage. TROUBLESHOOTING & TECHNICAL SUPPORT Problem Possible Cause Solution Light comes ON too Ramp rate may be set Increase ramp rate if desired slowly or goes OFF too slow too slowly when SwitchLinc is tapped (manually) SwitchLinc will not SwitchLinc may be in Re-enable Program mode, or perform take programming Program Disable mode a Factory Reset to reset SwitchLinc of ramp rate, etc. to factory defaults SwitchLinc is locked Surge in power line Reset SwitchLinc by pressing bottom of up or working rocker until it clicks into System only intermittently Off mode, then release LED is not visible Circuit breaker is off Turn circuit breaker on or connect fuse and/or SwitchLInc is not controlling SwitchLinc is in the Snap top of SwitchLinc into operating the light System Off position mode Insufficient load Incomplete (open) wire connection in wallbox Incomplete (open) wire connection at fixture Increase load to meet minimum load requirements Check wallbox wires to ensure all connections are tight and no bare wire is exposed Check fixture to ensure all connections are tight and no bare wire is exposed 6

SPECIFICATIONS Load types: permanently installed incandescent and general inductive loads Single pole or multi-location (with Slave Dimmers) Operation: Dimming Triac Maximum load: 600 watts / 600 VA Input power: 125 VAC, 5 amps, 60 Hz Connections (16 AWG): (to line) Red (to load) White (to neutral, required) Yellow (to optional multi-way circuit slaves (1135)) Addresses: 1 PLC (X-10) Base (Primary) Address of 256 possible On-Level: 1 of 31 possible (3.2%-100%) or resume dim Ramp Rate: 0.125 seconds to 9 seconds Maximum number of SwitchLincs per multiple-gang box: 4 Maximum number of SwitchLincs per circuit: 10 (with more than 6, a PLC amplified coupler-repeater is highly recommended) Minimum load: 40W Operating temperature range: -40 o F to 104 o F Minimum PLC transmit level: 2V Minimum PLC receive level: 10mV Maximum PLC signal rejection: 200mV Mounts in single or multiple-ganged J-box (Note: When 2 units are ganged together, use no more than a 500 watt load on each unit; when 3 or more units are ganged together, use no more than a 400 watt load on each unit. To avoid downgrading load control, use a larger box than needed to create space between the switches.) Nightlight indicator: Green LED Brightness indicator: 8 Green LEDs Dimensions - 4 x 1 11/16 x 1 7/8 Weight - 4 oz. Programming can be disabled (locked out) Switch can be physically disabled (and a hard reboot achieved) by a firm OFF press U.L. Listed for use in the U.S. and Canada WARNING!! Dimming an inductive load (such as a ceiling fan) below the minimum voltage set by the manufacturer of the load device could cause damage to the load device from overheating. If the manufacturer of the load device does not recommend dimming, DO NOT use Switch- Linc Lite with that device. USER ASSUMES ALLRISKS ASSOCIATED WITH DIM- MINGAN INDUCTIVE LOAD. 7