Safety coded magnetic sensor SR A series

Similar documents
Safety coded magnetic sensor SR B series

Safety coded magnetic sensor SR B series

Safety coded magnetic sensor SR A series

SR A series coded magnetic safety sensor

Coded magnetic safety sensor SR B series

SR B series coded magnetic safety sensors

Safety switches with separate actuator

Safety hinge switches HX series

Hinged-shaped safety switches in stainless steel, HX series

Safety switches with separate actuator

Safety switches for hinged doors

Safety hinge switches HX series

Safety switches with separate actuator

Safety switches with manual mechanical delay and separate actuator

Safety switches with manual mechanical delay and separate actuator

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Datasheet - RSS 36-D-R-ST

Hinged safety switches, Palladio line

ST series safety sensors with RFID technology

Datasheet - AZM300Z-ST-1P2P-A

Magnetic Non-contact Safety Switches. Model Number Structure

Microswitches MS Series

Safe switching and monitoring Non-Contact Safety Sensors

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Single contact blocks

Datasheet - CSS 11-30S-D-M-ST

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Safety switches with solenoid and separate actuator

ST series safety sensors with RFID technology

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

Position switches FD series

Position switches FD series

Compact Magnetic Non-contact Safety Switches. Model Number Structure

Coded Non-Contact Safety Sensor Eden OSSD

HP-HC series safety hinge switches

Safety. Detection. Control. MAGNUS RFID ENG - REV

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Datasheet - MZM 100 B ST-1P2PW2REM-A

illuminated button R S P F flush projecting protected mushroom white red green yellow blue orange black

Datasheet - BNS ZG

Safety Switches CES-AR/CET-AR

Datasheet - AZM 200 BZ ST-T-AS P

Operating instructions Safety sensor BNS About this document. Content

Datasheet - BNS ZG-ST

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Datasheet - AZM 200SK-T-1P2PW

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Datasheet - AZ 16-03ZVRK

Datasheet - AZ 15 ZVK

Safety hinge switches HP-HC series

Datasheet - AZ 16-02ZVRK-ST

Datasheet - SRB 402EM-24V

Datasheet - AZ 16-02ZVK

Datasheet - AZ 15 ZVRK

Inductive sensor BI5-EM18-Y1X-H1141

Online data sheet. TR4-SDM03P TR4 Direct NON-CONTACT SAFETY SWITCHES

Datasheet - AZ 15 ZVRK

Datasheet AZM 161 Z ST1 AS RA

Datasheet - SRB 301LC/B-24V

Datasheet SRB301ST 24V (V.2)

K1B004TLH cam switch - 1 pole A - screw mounting

RM35LM33MW liquid level control relay RM35-L V AC/DC

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

K1D012ULH cam changeover switch - 2-pole A - screw mounting

Thread length (overall length) material

Datasheet - AZ 15 ZVRK

Datasheet - AZ 15 ZVRK

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Datasheet - AZ 16ZVRK

GENERAL TECHNICAL DATA Specifications, Directives and Standards

Single buttons. Selection diagram. 31 General Catalogue HMI BUTTON. illuminated button TYPE. R S P F flush projecting protected mushroom

Operating instructions Safety sensor BNS About this document. Content

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

XCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11

Inductive sensor BI1.5-EG08-Y1-H1341

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

Magnetically Coded Safety Switches CMS

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

K1F006ALH cam switch - 6-pole A - screw mounting

Operating instructions. Speed monitor D / / 2014

XCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

VF CNM5MM-L100. Accessories. M12 male connectors. Code structure. M 12x1

XCMD21F0L2 limit switch XCMD - M12 metal end plunger - 1NC+1NO - snap - 2 m

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

MECHAN. CAT 4 SIL 3 PLe. Installation Guide : SCU-1 & HE Safety Switches. Description. Operation. Applications. Declaration of Conformity

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKD2145N12 limit switch XCKD - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

Transcription:

B Safety coded magnetic sensor SR A series Selection diagram ACTUATOR SENSOR CONTACTS SM A0N actuation distance 5 mm 0 +NO NC+NO Contacts have to be intended with closed protection. OUTPUT TYPE SR AD N SR AL N SR AD LK SR AL LK SR AD M0. SR AL M0. M connector with M connector with PVC integrated cable PVC integrated cable M8 connector M8 connector cable length 0. m cable length 0. m output from right side output from left side output from right side output from left side output from right side output from left side / General Catalog 0-0

B Introduction Coded magnetic sensors are devices studied to monitor protections and guards that, when linked to a safety module, can create a system with safety category up to SIL according to EN 606, up to PLe according to EN ISO 89- and up to category according to EN ISO 89-. These products are composed by a magnetic field monitoring sensor, which is connected to the machine structure; and by a coded magnetic actuator, which has to be connected to the mobile guards. When sensor and actuator are neared (closed guard), the sensor recognizes the actuator and provides to actuate electric contacts. The sensor is manufactured to be activated only by the correct coded actuator and not through a common magnet. Sensor with actuator code structure SR AD0AN-A0N Sensor housing SR polymer housing Connection output direction D L Output from right Output from left Contacts (with closed protection) 0 (standard) NO+ (standard) Actuator complete with SM A0N actuator, A0N actuation distance 5 mm Type of cable or connector N integrated PVC cable, length m N integrated PVC cable, length m (standard)...... N0 Integrated PVC cable, length 0 m M0. M connector with cable length 0. m M8 connector (available with 0 and LK contacts only) Single sensor code structure SR AD0AN Sensor housing SR polymer housing Connection output direction D L Output from right Output from left Contacts (with closed protection) 0 (standard) NO+ (standard) Type of cable or connector N integrated PVC cable, length m N integrated PVC cable, length m (standard)...... N0 Integrated PVC cable, length 0 m M0. M connector with cable length 0. m M8 connector (available with 0 and LK contacts only) Single actuator code structure SM A0N Actuator A0N actuation distance 5 mm General Catalog 0-0 /

B Safety coded magnetic sensor SR A series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Version with integrated cable with or 6 x 0.5 mm wires length m, other lengths on request. Versions with M8 connector Versions with M connector with cable length 0. m Protection degree: IP6 according to EN 6059 IP69K according to DIN 0050 (Protect the cables from direct high-pressure and high-temperature jets) General data For safety applications up to SIL / PL e Safety parameters: see page / Ambient temperature: -0 C... +80 C Vibrations holding: 0 gn (0...500 Hz) according to IEC 60068--6 Shock holding: 0 gn ( ms) according to IEC 60068-- Pollution degree Max screw driving torque: 0,8... Nm Main data Long life, no mechanical wear Output contacts:, NO+ or Insensitive to dirt Protection degree IP6 and IP69K Coded actuator Polymer housing Versions with M8 or M connector Markings and quality marks: In conformity with standards: IEC 609-, EN 609-, IEC 609-5-, EN 609-5-, EN 609-5-, EN 609-5- (in connection with safety module), EN 088, EN ISO, EN ISO 00-, EN ISO 00-, EN ISO 89-, EN ISO 89-, IEC 600-, EN 600-, IEC 6059, EN 6059, DIN 0050. Approvals: UL 508. Actuating data Assured operating distance Sao 5 mm with actuator A0N Assured release distance Sar 5 mm with actuator A0N Repeat accuracy 0% Frequency of operating cycles up to 50 Hz Distance between two sensors Min. 50 mm Approval UL: E8 Approval TÜV SÜD: Z0 0 09 55 00 Approval GOST: POCC IT.AB.B05 In conformity with requirements requested by: Low Voltage Directive 006/95/EC Machinery Directive 006//EC Electromagnetic Compatibility 00/08/EC. Electrical data Rated insulation voltage Ui: Rated impulse withstand voltage (U imp ): Thermal current Ith: Max switching load: Rated operational voltage (Ue): Rated operational current (Ie): Protection fuse: Electrical endurance: 0 Vac (with cable) 60 Vac / 5 Vdc (with M8 connector) 0 Vac (with poles M connector) 0 Vac / Vdc (with 8 poles M connector) 6 kv,5 kv (with connector) 0.5 A 6 W (resistive load) Vac/DC 0.5 A (resistive load) 0.5 A type F million operations cycles Connection with safety modules with personnel protection function: Connection with safety modules CS AR-0 E0; CS AR-0 E0; CS AR-0 0; CS AR-05 ; CS AR-06 ; CS AR-08 ; CS AR-6 0; CS AR-9 ; CS AR-95 ; CS AT-0 ; CS AT- ; CS AT- ; CS FS-5 ; CS MF - ; CS MP -. The sensor connected with the safety module can be classified as device for control circuit up to PDF-M (EN 609-5-). The system can be used in safety circuits up to PLe / SIL / category according to EN ISO 89-. Data type approved by UL Utilization categories: Vdc, 0,5 A (resistive load)) Data of the housing type, X indoor use only, Accessory for series CS. In conformity with standard: UL 508 Data type approved by TÜV SÜD Supply voltage: V AC/DC Output switching current (max): 0,5 A Working temperature: -5 C + 80 C IP code: IP6 PL, Category: PL e, Cat. with CS AR-08 Tested according to: 006//EEC Machine Directive, EN ISO 89- :008, EN 609-5-/A:005, EN 508:9, EN 6508-:98 (SIL -), EN 6508-:000 (SIL -), EN 6508-:98 (SIL -), IEC 606:005 (SIL CL ), EN 609- Please contact our technical service for the list of approved products. Please contact our technical service for the list of approved products. / General Catalog 0-0

B Insensitivity to dirt Magnetic sensors are totally sealed and maintain unchanged their safety characteristics also where dirt and dust are present (not ferromagnetic material). This characteristic, joined with the shape without recesses, make them especially proper to the use in the agro-industrial sector. Wide actuation zone Because of their intrinsic characteristics, magnetic sensors have a wide actuation zone, which make them appreciated in the use of inaccurate protections or for protection that can change their mechanic characteristics through the time. In this type of sensors actuation distances may change according to the actuator displacement direction from the sensor. Safety screws for actuators These new screws have tamper-resistant Torx buttonheads. Devices fixed with this kind of screws cannot be removed or tampered by common tools. See accessories page 6/5. Actuation from many directions Pizzato Elettrica magnetic sensors have been designed in order to be activated by the related actuator from many directions. In this way, the customer has the max flexibility about the placing of the devices along the protections perimeters. Coded magnetic sensors used for safety applications A coded magnetic sensor alone can not be used for safety functions because its working principles are not considered safe by the standards (as are, for example, the positive opening on mechanical switches). For this reason a coded magnetic sensor, in order to be used in safety applications, has to be compulsory connected to a proper safety module which controls correct operation, through a circuit with at least two channels. Laser marking Pizzato Elettrica has introduced a new laser marking for magnetic sensors SR series. Thanks to this new system which excludes the use of labels, markings on the products are indelible. Furthermore, in case of machineries subjected to intense high pressure water jets, there is no risk of labels detaching from the product. Protection degree IP6 and IP69K The SR series sensor by Pizzato Elettrica, besides having an IP6 protection degree, have passed the test proving their IP69K protection degree according to the prescriptions established by the DIN 0050 standard.therefore they are suitable for use in machineries subjected to intense washing with high pressure and high temperature water jets and for any condition or environment where a particular attention for cleanness and hygiene is required, such as in food or pharmaceutical industry. Complete safety system These magnetic sensors SR A 0 have been checked and tested for working with proper Pizzato Elettrica safety modules. Using completed and tested solutions, the customer has the certainty to have no electric incompatibility between sensor and safety module, and has a higher reliability guarantee. L / + N / - Sensors SR AD0A SR ADA SR ADA * Compatible safety Safety module output contacts modules Instantaneous Delayed CS AR-0 E0 NO+NC / CS AR-0 E0 NO / CS AR-0 0 NO+NC / CS AR-05 NO+NC / CS AR-06 NO+NC / CS AR-08 NO / CS AR-6 0 NO / CS AR-9 NO / CS AR-95 NO / CS AT-0 NO+NO NO CS AT- NO NO CS AT- NO NO CS FS-5 +CO / CS MP - see page 5/6 see page 5/6 * Compatible with CS MF -P (page 5/) and CS MP - only. For safety modules technical data see page 5/. Connection of sensors and switches in series Pizzato Elettrica magnetic sensors could be connected in series with the only limitation that the overall resistance, gave by sensors and the related wiring, has to be not higher than the admitted max value of the module, which typically is equal to 50 ohm (see module features). It is a very high value that, with normal wiring, it allows the use of dozens of sensors without problems. It is also possible to realize mixed circuit solutions connecting in series magnetic sensor to safety switches, with the only limitation of the above mentioned max electric resistance. We remind you that connection in series of two or more coded sensors reduce the system self-monitoring capacity which passes to category in conformity with EN ISO 89-. It is advisable to use safety modules by Pizzato Elettrica. FX 69 FR 896 CS AR-08 General Catalog 0-0 /

B Safety coded magnetic sensor SR A series Wiring with safety modules Wiring with safety modules CS AR-05 or CS AR-06 Input configuration with manual start (CS AR-05) and monitored start (CS AR-06) channels Wiring with safety module CS AR-08 or CS AT Input configuration with manual start channels L / + L / + A S S S5 A S S S S CS AR-05 / CS AR-06 CS AR-08 / CS AT S S S A S S S5 S A SR AD0 For safety modules technical data see page 5/. N / - SR AD0 N / - Internal connections Contacts imply closed protection With cable () With cable (NC+NO) With cable (+NO) With M8 connector () With M8 connector (NC+NO) Black White Brown Blue Black White Brown Blue Green Brown Grey Pink White Yellow With M connector (+NO) With M connector () With M connector (NC+NO) 6 5 8 5 6 8 Intervention distance SR AD -A0N (mm) 5 (mm) 5 0 0 5 5 0 0 5 5 0-5 -0-5 0 5 0 5 (mm) 0-0 -.5-5 -.5 0.5 5.5 0 (mm) Legend: Assured operating distance Sao Assured release distance Sar Note: The drawing of the activation areas is indicative. /5 Female connectors See page 6/ - 6/ General Catalog 0-0

B Dimensional drawings cable, length m from left cable, length m from left coded actuator.6 5. 0 0 5..6 6.5.5.5 SR AD0AN SR ADAN SR ADAN NO+ SR AL0AN SR ALAN SR ALAN NO+ SM A0N Actuation distance 5 mm.6 5. M8 connector from right M 8 x....5. M8 connector from left 5..6 M 8 x M connector with cable length 0. m output from right.6 5..5 0 M connector with cable length 0. m output from left 0 5..6.5.5 SR AD0ALK SR ADALK SR AL0ALK SR ALALK SR AD0AM0. SR ADAM0. SR ADAM0. NO+ SR AL0AM0. SR ALAM0. SR ALAM0. NO+ Spacer 8 This spacer is placed between the SR magnetic sensors and metal surfaces that can deviate the magnetic field created by the sensor: with this specific spacer between them the sensor activation and deactivation distances remain the same. Made of a single block material it suits any application where high cleanness is required since it prevents any material in the installation area from getting and settling inside the drain. Article VS SPAA Description Spacers for SR A series Utilization limits The installation must be performed by qualified staff only. Before installation and at regular interval, check the right contacts switching and the system operation of the sensor and the associated safety module. Do not use a hammer for adjustment. Do not use the sensor as a mechanical stop. Observe the assured operating and release distances. It is advisable to make adjustment observing the diagram reported in the switching distances section. Do not install the sensor and the actuator on strong magnetic field. Keep away from iron filing. Shock, vibrations and wear: Do avoid impact with the sensor. Excessive shock and vibrations could not guarantee the right working of the sensor. The actuator must not strike sensor. In case of damages or wear is necessary to change the whole device, included the actuator. Warning during the wiring: Keep load under the value indicated in the electrical data. When the sensor contacts are used without the respective safety module, connect in series to each contact the protection fuse indicated in the electrical data. Turn off the power supply before check the switch connection contacts, also during the wiring. Installation on ferromagnetic material If possible do not mount the sensor and the actuator on ferromagnetic materials. In order to avoid switching distances reductions, use VS SPAA spacers. Multiple systems sensor-actuator assembly The minimum mounting gap between sensor-actuator systems must be at least 50 mm. 50 Spacer Accessories See page 6/ All measures in the drawings are in mm General Catalog 0-0 Items with code on the green background are available in stock /