Description of the DNC interface (reduced ASCII format)

Similar documents
Contents. WinNC Starting Information Turning. W: Accessory Functions... W1. Y: External Input Devices... Y1. Z: Software Installation...

Contents. WinNC Starting Information. W: Accessory Functions. X: EMConfig. Y: External Input Devices. Z: Software Installation Windows K

DirectNET Host. Communications Programs. In This Chapter...

GE FANUC 21 CONCEPT 55 TURN TEACHER GUIDE

Operation Manual (B) KVR-2418 (24L) Fanuc OiMD CNC. KENT INDUSTRIAL (USA) INC Edinger Ave., Tustin, CA 92780

GE FANUC 21 CONCEPT 55 MILL ATC TEACHER GUIDE

MELDAS, MELDASMAGIC, and MELSEC are registered trademarks of Mitsubishi Electric Corporation. The other company names and product names are

PM290 POWERMETER. Communication Protocols ASCII & Modbus Reference Guide

BIET EtherNet Interface

Chapter 20 Network Layer: Internet Protocol 20.1

SPPC-Lite User s Manual

NCT. PLC Programmer s Manual. Machine Tool Controls. From SW Version x.061 (M) (L)

TR600 with RS485 Appendix 1

K2289: Using advanced tcpdump filters

User manual. Actuator with RS485/SIKONETZ5 interface AG03/1

Fanuc Focas Ethernet Driver Help Kepware, Inc.

Digital display for EMCO milling machines

MOBY -I/-L and M Identification System T3964R Driver

SINUMERIK 828D / 840D sl quick reference chart

TOSVERT VF-S15 Series RS485 Communication Function Instruction Manual

The probe unit is controlled via an AX5000 configuration dialog. In multi-channel devices a probe unit is available for each channel.

TOSVERT VF-S9 Communications Function Instruction Manual

Russound Dual Tuners (ST2, ST2-XM, ST2-XM2, and ST2S)

User Module. Modbus TCP2RTU. Application note

DATA LINK LAYER UNIT 7.

RC-SV Configuration Guide (Rev 4)

A Issue A Original. Instruction Manual. nxds Serial Comms Interface

CNC MILLING MACHINE NER VC180)

SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL

Automatic transfer switch

ivu Plus BCR Communications Instruction Manual

Appendix. Web Command Error Codes. Web Command Error Codes

Configuring Logosol CNC page 2. Setting up the machine limits and user units page 3. Setting up the Motion parameters page 4. I/O mapping page 7

PJLink Specifications

Elotech Standard Protocol. for Single R8200 SC

Overview. Exercise 0: Implementing a Client. Setup and Preparation

GSK218M Milling Machine CNC System

GE Focas Ethernet Driver Help Kepware Technologies

Introduction. The following documents are available as documents related to the contents of this manual. Refer to these as required.

DCN Next Generation Open Interface Release 2.4. en User Manual

ASG-NW2500-ACOP ACOP Network Communication Module. User s Guide

IMPORTANT PRODUCT INFORMATION

HDV100A3 Command Response Protocol

AG25, AG26. User manual 225/18

Lecture 3: The Transport Layer: UDP and TCP

LMV2 / LMV3... Modbus. User Documentation. Building Technologies Division

For the latest information about this machine (including manuals), see the Roland DG Corp. website (

Communication protocol

APPENDIX F THE TCP/IP PROTOCOL ARCHITECTURE

M I T 303 B I T - M I L L E N N I U M E X C H A N GE. MITCH Specification. Issue 6.7 October 2014

Gryphon Hardware Information: Dual SJA1000 Fault Tolerant CAN card

Lufkin Modbus Serial Driver Help Kepware Technologies

Configuring Flood Protection

Chapter 7 Internet Protocol Version 4 (IPv4) Kyung Hee University

CNC Turning. Module2: Introduction to MTS-TopTurn and G & M codes. Academic Services PREPARED BY. January 2013

HEIDENHAIN DNC and RemoTools SDK Tools for Creating PC-Based Applications for the TNC

Transmission/ reception tables

Digital Arithmetic. Digital Arithmetic: Operations and Circuits Dr. Farahmand

System Design Guide for Slave

Configuring Anomaly Detection

Overview. Exercise 0: Implementing a Client. Setup and Preparation

ArcaTrade Specification for Bonds

Operation Manual. 3.1 Absolute coordinate Relative coordinate Mechanical coordinate

ET4254 Communications and Networking 1

FERGUSON BEAUREGARD. RTU-5000 Configurator User Manual

Russound Controllers. RNET Protocol & Specifications RS-232 Communication. Document version

Merbon Menu Reader. Installation and setup V1.0 1

CNC C6/C64/C64T PROGRAMMING MANUAL (LATHE TYPE) BNP-B2264D(ENG)

DELPHI CORPORATION. LIN to RS-232 Gateway Systems Analysis INterface Tool (SAINT) Users Guide

The DNC-Process 6.5 is an event-controlled, Hardlock-protected 32bit software for the operating systems WINDOWS 9x/NT4.0/2000/XP.

FANUC PLC Parts. GE Fanuc Automation. Series 15i / 150i Model A Remote Buffer. Computer Numerical Control Products. Descriptions Manual

Inspirel. YAMI4 Requirements. For YAMI4Industry, v page 1

SINUMERIK 840D sl Upgrade Instructions SINUMERIK Operate 2.6 SP1 HF3 for PCU 50.3

ABB Modbus RTU Driver for JMobile

1. Introduction. Be sure to read the release notes in section 10 before operating the Unit.

Modbus User Manual APPLIED MOTION PRODUCTS, INC. Modbus is a registered trademark of Schneider Electric, licensed to the Modbus Organization, Inc.

NOTE This function is optional.

F Technical Bulletin FTS 371 SMART Modbus Interface

TCP/IP Transport Layer Protocols, TCP and UDP

MVI46-MCM SLC Platform Modbus Interface Module USER MANUAL. February 5, 2004

SPM90 MODBUS PROTOCOL AND REGISTER LIST V1.0

PART III. Data Link Layer MGH T MGH C I 204

ROC Plus Ethernet Driver

C-Bus Interface Requirements

Operation and installation manual KNX IP BAOS 773. KNX IP BAOS 773 as application specific Gateway BAOS SDK. Application. Installation and Connection

Modbus Remote Communication Protocol for REM 54_. Technical Description

Interface system Probus V

SIMATIC NET. S TeleControl MSC300_Library program block library. Block library for TCSB (V3) WDC_S7_300_... (FB92) 2 UDT_WDC_PARAM (UDT91) 3

NSRTW_mk2 WiFi Interface Open Extensions

Communication. Outline of Communication. Merits

LomaLink User s Guide

Script Step Reference Information

NT 200/420. Communication in Gateway Setup SOFTWARE DESIGN GUIDE ENGLISH

Co-Ordinated Retail Market Message Guide

CREATING PANEL APPLICATIONS

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Programming Manual Control and Power Unit TMP

Beijer Electronics AB 2000, MA00453,

-DIN & DIN RaPID TEMPERATURE CONTROLLERS. Product Manual (June 1999)

$GDSWLYH0LFUR6\VWHPV

Transcription:

1. Functionality Description of the DNC interface (reduced ASCII format) The DNC interface creates a connection between a superordinate computer (production master computer, FMS-computer, DNC-host computer etc.) and the control computer of an NC machine. After activation of the DNC operation the DNC computer (Master) takes over the control of the NC machine (Client). The entire production control is completely assumed by the DNC computer. The automation devices such as doors, clamping chuck (collet), sleeve, coolant etc. can be controlled by the DNC computer. The actual status of the NC machine is displayed on the DNC computer. 2. Communication The protocol for the communication between NC machine (DNC interface) and the DNC computer is designed in such a way that a connection can be carried out via character-oriented (e.g. RS-232) as well as via block-oriented communication layers (e.g. Ethernet / TCP/IP or USB). Communication is executed package-oriented in acknowledgement traffic. Presently, the connection to the DNC computer can only be set up via the RS-232 interface and TCP/IP. If TCP/IP is used, incoming connections at Port 5557 are listened to. In case the TCP/IP connection is interrupted in operation, the control remains in DNC operation and can be controlled again with commands after a new connection reset-up. 2.1. Package setup The transmitted packages consist of a package header and the package data with a maximum length of 9 bytes. Package header: Field contents Bytes Note Check sum 1, binary The checksum is formed by adding up the entire package incl. the data without the checksum itself. In order to get a valid character for the reduced ASCII format divide the checksum by 64 and then add 48 (ASCII 0 ) to the remainder of the division. Command group 1, ASCII Command group (see 3 rd command description) Command 1, ASCII Command identification (see 3rd command description) code/identification Package number 1, ASCII The package number always has the end identification (ASCII E ). Message number 2, ASCII The message number always is 00 (ASCII). Command length 2, ASCII Indicates the number of bytes of the useful data without the package header. The second byte must always be "0". Thus, a maximum useful data length of nine bytes results. Package data: 'The package data contain the useful information which is different for each of the commands (see 3 rd command description). 2.2. Command traffic Communication between the computers is executed in acknowledgement traffic. Before the start of a new command the acknowledgement of the last command must be waited for. 3. Command description 3.1. General In the following the DNC commands are described. The division into special command groups is carried out at random. Explication of the command syntax: EMCO TEE Softwareentwicklung Seite 1 25.11.2009

The arrows indicate the direction of the data flow: from the DNC computer to the NC control from the NC control to the DNC computer The two characters indicate the respective command group and identification (ASCII-characters!). Further data refer to the area of the useful command data. If useful data are not described and some of them are transmitted in spite of that, they are ignored and the command is executed regularly. 3.2. Communication error In case of errors during the transmission or with inadmissible commands the following messages can be sent to the DNC computer. General communication error N V 1 (ASCII) Unknown command N V 2 (ASCII) Error in check sum N V 3 (ASCII) Inadmissible command N V 4 (ASCII) Incomplete package N V 5 (ASCII) In case of a general communication error the driver reports an error during receipt to the interface. Therefore, the package was rejected. An inadmissible command exists if this command is not allowed during the actual status of the control. This is the case when a new command is sent before the last one has been acknowledged by the control. Another possibility would be the receipt of commands without prior activation of the DNC operation and/or after having already switched off the DNC operation. A package is recognized as incomplete if a package has not been completely received and no further data arrive in the control within a defined timeout. The package data received so far are rejected. 3.3. Start DNC operation The DNC computer reports to the NC machine and requests a transition into DNC operation (1st command!). Thus, the NC machine is switched to operation mode automatic (display DNC on the screen). DNC operation can be activated at any time (irrespective of the status of the control). Transition into DNC operation B S pos. acknowledgement C V Activation not possible (neg. N B acknowledgement) If you try to send the command with DNC operation already activated, you receive a neg. acknowledgement, but DNC operation remains active. 3.4. Terminate DNC operation The termination of the DNC operation is triggered by the DNC computer. Termination of DNC operation B E DNC operation terminated (pos. Q B acknowledgement If the control is terminated with active DNC operation, a message is given to the DNC omputer. Software of machine terminated C B EMCO TEE Softwareentwicklung Seite 2 25.11.2009

3.5. System status During the execution of a command (production dialogues, referencing) the system status concerning this command is transmitted to the DNC computer. The system status describes the operating mode of the machine (automatic, manual, reference point status), the program status (NC program number and/or NC program name, processing status, SKIP), the status of the automation devices (doors, clamping devices, sleeve, coolant, auxiliary drives, ) as well as actual override values (feed, spindle). 3.5.1. Set-up system status Designation Memory type Note Operation mode of the machine 1 byte (ASCII) 1 byte (ASCII) A..Automatic, M..Manual R.. Reference point valid,, F.. ref. run active, N.. Reference point not valid NC program number 4 byte (ASCII) actual program number, e.g. 0001 FFFF = no program selected NC program status 1 byte (ASCII) L.. active, R.. Reset SKIP status 1 byte (ASCII) 1.. active, 0.. inactive swivelled in tool 4 byte (ASCII) tool number, e.g. 0001 FFFF = invalid tool Door status 1 byte (ASCII) 0.. open, 1.. closed, 2.. intermediate position Clamping device 1 byte (ASCII) 0.. released, 1.. clamped, 2.. intermediate position Sleeve 1 byte (ASCII) 0.. back, 1.. front, 2.. intermediate position Coolant 1 byte (ASCII) 0.. off, 1.. on EMERGENCY-OFF status us1 byte 0.. OK, 1.. Emergency-off (ASCII) Auxiliary drives 1 byte (ASCII) 0.. off, 1.. on Feed override value 4 byte (ASCII) in per cent, e.g. 0100 Spindle override value 4 byte (ASCII) in per cent, e.g. 0080 Blow-out status 1 byte (ASCII) 0.. off, 1.. on Dividing device 1 byte (ASCII) 0.. fixed, 1.. in movement 3.6. Monitoring The DNC computer has the possibility to check at any time (also with active peripheral command) if the connection to the control is still operative (ALIVE message). Connection monitoring C V Acknowledgement Q V 3.7. Referencing This command starts referencing the NC machine. If referencing is not terminated within the time limit set, you receive a negative acknowledgement. Referencing the machine A R Referencing OK C Z System status operating mode of machine Referencing failed N A 3.8. Production dialogues These commands control the production of workpieces. Among them are commands for program influence such as program selection, program start, program stop, skipping NC blocks, resetting the machine (RESET), commandos for triggering the automation devices such as the doors, the clamping device, the coolant, the tool turret, etc. as well as commands for production influence such as modification of the override values. If peripheral requests are declined by the PLC (e.g. dividing device not available) or if the time limit is exceeded you receive a negative acknowledgement and the command is interrupted. EMCO TEE Softwareentwicklung Seite 3 25.11.2009

NC program selection S W Program number (4 bytes ASCII), e.g. 0001 Acknowledgement C Z System status NC program number NC start release S S RESET at machine S R NC-STOP at machine S H Activate/disable SKIP S A Status (1 byte ASCII): 0=off / 1=on Acknowledgement C Z System status SKIP status Change feed override value O F FOV- value in per cent (4 bytes ASCII), e.g.0100 Acknowledgement C Z System status feed override value Change feed override value O S SPOV value in per cent (4 bytes ASCII), z.b.0080 Acknowledgement C Z System status spindle override value Peripheral commands: Swivel tool turret P T none (swivel to next position) Auxiliary drives P A Status (1 byte ASCII): 1=on / 0=off Automatic doors P D Status (1 byte ASCII): 0=open / 1=close / 2=stop Clamping device P S Status (1 byte ASCII): 0=release / 1=clamp Sleeve P P Status (1 byte ASCII): 1=forward / 0=backw. Coolant P C Status (1 byte ASCII): 1=on / 0=off Blow-out P B Status (1 byte ASCII): 1=on / 0=off Dividing device P I none (to next division) pos. acknowledgement C Z System status of requested peripheral equipment neg. acknowledgement N P 3.9. Command cancellation With this message the active command can be cancelled. All actions for the active command are interrupted. Cancel command C A Acknowledgement Q A 3.10. Determination of the control type This command can be used to examine if the control is a Sinumerik 840 d (package is answered regularly) or another control (package is answered as unknown command). EMCO TEE Softwareentwicklung Seite 4 25.11.2009

Determine control type C T pos. acknowledgement Q T Control type: 0.. Sinumerik 840d EMCO TEE Softwareentwicklung Seite 5 25.11.2009