Waterproof. Keypad/Reader/Controller

Similar documents
W3-H Waterproof Keypad/Reader/Controller

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

W3-M. Metal waterproof standalone access control/reader. User Manual

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

CM-110SK Standalone Keypad Installation Instructions

Single Door Standalone Access Control User Manual

BC Digital Keypad. User Manual

DOLXFD1000B. Waterproof Access Control/Reader

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

User Manual. PCKeypad Wireless Keypad

VIDI-AC-2CS Access Controller/ Reader

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Fingerprint Access Control F1. User Manual

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Stand-alone Proximity Access Control

-DTZ001- Stand-Alone Proximity Access Control. User Manual

RBR-SB-KTZ001 LAR 2. User Manual

User Manual. Split access control with intelligent secured power supply.

Digital Keypad Introduction

VIS-3200 / VIS-3201 User Manual

CC Series metal access control Manual

EL-ST100 KEYPAD CONTROLLER

Installation and User Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Metal Standalone Keypad Access Control S100

ACCESS CONTROL SYSTEM

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

HSY-S209 EM Metal waterproof access control system User Manual

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

1. Product Specification

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

CV-945 Stand-Alone Biometric Reader. Installation Instructions

REX F-0-9 Standalone or Access Controller

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Specifications: Features:

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

_ Access control SISTEMAS DE SEGURIDAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

FTK5 PROXIMITY KEYPAD

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

Installing Keypad and Backplate

DG Series. Access Control Proximity Readers DG-160 DG-800

CP150B Vandal & Weather Resistant Keypad Security Systems

GV-Card Reader. User s Manual

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

EX8. User Manual. Ver 1.0

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Compact Keypad. ins /02/2010. Exit button (push to make) 12V DC release current rating must be less than 1A.

7612 Programming Instructions

IBA-7612 Programming Instructions

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

CM-500 SK 500 USER CODES KEYPAD

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Revision Date: 02 Mar 2018

2000 Series e/em Style Keypad Installation and Programming Manual

KP2000E/EM Series Style Keypad

GV-AS Controller. Installation Guide

RFID PRODUCT AND SYSTEM

212iL Rev. 1.1

ACTsmart2 Product Range Operating and Installation Instructions

Two Door Controller GEN-045

Waterproof Exit Button x40x30/44mm - IP68, 304 Stainless Steel - Voltage: DC12V, DC9-24V (-W402N)

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

GV-EL124S Electric Strike

AYC-F/G/M60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

Wireless Key fob, Key pad & Receiver Range

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Fast operation of IP Villa System V 1.0

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

AYC-E/Q/T60 Family Backlit goprox & PIN Reader Convertible Series with Genuine HID Technology Installation and Programming Manual

PAC1 Door Access Controller

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

PAC1 Door Access Controller

AC-Q4x Family Anti-Vandal Standalone Controllers Installation and Programming Manual

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Access control panel U-Prox IC E (Elevator control)

AS Keypad User Manual

INSTRUCTION MANUAL AC-T43 PIEZO-KEYPAD STANDALONE ACCESS CONTROL UNIT. 07/04

Section 1 General Description. Section 3 How to Program Keypad. Section 2 Installation. CM-120TX Wireless Digital Keypads Installation Instructions

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

ECI1. COMPASS display. ECI1-REV For latest update: Electronic Compass Indicator ECS1

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

AYC-Ex5/T65 Family Convertible Backlit Proximity & PIN Readers/Controllers Installation and Programming Manual

GV-RK1352 and GV-R1352 Card Reader

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Wireless Digital Video Doorbell

RFID/Digital Access Control Keypad

E-Access ANXELL TECHNOLOGY CORPORATION E3AK4 E3AK2. Specifications Voltage (Input): 12 to 24 VDC

Transcription:

Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual

1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing Self tapping screws 4 3.5*27mm, used for fixing Manager Card 2 Manager Add Card & Manager Delete Card Please ensure that all the above contents are correct. If any are missing please notify the supplier of the W1-C/W3-C. 2. W1-C/W3-C Quick Reference Programming Guide To enter the programming mode * Master code # 888888 is the default factory master code To exit from the programming mode * Note that to undertake the following programming the master user must be logged in To change the master code 0 New code # New code # The master code can be 6 digits long To add a PIN user 1 User ID number # PIN # The ID number is any number between 1 ~ 2000. The PIN is any 4~8 digits between 0000 ~ 99999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode To add a card user 1 Read Card # Cards can be added continuously without exiting from programming mode To delete a PIN or a card user. 2 User ID number # for a PIN user or 2 Read Card # for a card user 2

Users can be deleted continuously without exiting from programming mode To unlock the door To unlock the door for a PIN user Enter the PIN then press # To unlock the door for a card user Present the card 3. Description The W1-C/W3-C is single door multifunction standalone access controller or a Wiegand output keypad or card reader. It is suitable for mounting either indoor or outdoor in harsh environments. It is housed in a strong, sturdy and vandal proof Zinc Alloy electroplated case which is available in either a bright silver or matt silver finish. The electronics are fully potted so the W1-C/W3-C is waterproof and conforms to IP68. The W1-C/W3-C supports up to 2000 users in either a Card, 4~8 digits PIN, or a Card + PIN option. The inbuilt card reader supports EM 125KHZ frequency cards/tags. The W1-C/W3-C has many extra features including block enrollment, wiegand 26 bits interface, and backlit keypad etc. These features make W1-C/W3-C an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons. 4. Features Waterproof, conforms to IP68 Strong Zinc Alloy Electroplated anti-vandal case Full programming from the keypad 2,000 users, supports Card, PIN, Card + PIN Can be used as a stand alone keypad, Pin length 4~8 digits Backlight keypad Wiegand 26 input & output One programmable Relay output, NO, NC, COM Adjustable Door Output time, Alarm time, Door Open time Block enrollment, can enroll maximum 2000 consecutive card within 2 minutes Very low power consumption (<60mA) Easy to install and program Built in light dependent resistor (LDR) for anti tamper Built in buzzer Red, Yellow and Green LEDs display the working status 12~24V AC/DC 3

Two-year warranty 4

5. Specifications Operating Voltage 12~24V AC/DC User Capacity 2,000 Keypad 12 keys, 2 x 6 digits(w1-c) 12 keys, 3 x 4 digits(w3-c) Card Type EM 125 KHZ card Card Reading Distance 3~6 cm Active Current <80mA Idle Current 40mA Lock Output Load Max 2A Alarm Output Load Max 20A Operating Temperature -20~60 Operating Humidity 5%~95% RH Environment Conforms to IP68 Adjustable Door Relay time 0 ~ 99 seconds Adjustable Alarm Time 0 ~ 3 minutes Wiegand Interface Wiegand 26 input & output Wiring Connections Electric Lock, Exit Button, DOTL, External Alarm Dimensions L135 x W58 x H26 mm (W1-C) L128x W82 x H28 mm (W3-C) Net Weight 550 g Gross Weight 700 g 6. Installation Remove the back cover from the keypad using the supplied security screwdriver Drill 4 holes on the wall for the screws and I hole for the cable Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole Attach the keypad to the back cover. 5

7. Wiring Color Function Description Green D0 Wiegand Output D0 White D1 Wiegand Output D1 Grey Alarm - Alarm Negative Yellow OPEN Request to Exit Button Brown D-In Door Contact Red 12V~24V AC&DC 12~24V AC&DC Regulated Power Input Black 12V~24V AC&DC 12~24V AC&DC Regulated Power Input Blue NO Relay NO Purple COM Relay COM Orange NC Relay NC Pink GND W1-C/W3-C Negative Connection Diagram 6

Notes: Connect the negative pole of the lock to NC is for Fail safe lock. Connect the negative pole of the lock to NO is for Fail-secure lock. 7

8. To Reset to Factory Default To reset to factory default, power off, press *, hold it and power on, release it until hear two beeps and the LED shines in orange, then read any two EM cards, the LED will turn in red, means reset to factory default setting successfully. Of the two EM cards read, the first one is Manager Add card, the second one is Manager Delete card. Remarks: Reset to factory default, the user s information is still retained. 9. Anti Tamper Alarm The W1-C/W3-C uses a LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the cover then the tamper alarm will operate. 10. Sound and Light indication Operation Status Red Light Green Light Yellow Light Buzzer Power on Bright - - Short Ring Stand by Bright - - - Press keypad - - - Short Ring Operation successful - Bright - Short Ring Operation failed - - - 3 Short Rings Enter into programming mode Bright - - Short Ring In the programming mode - - Bright - Exit from the programming Bright - - Short Ring mode Open the door - Bright - Short Ring Alarm Bright - - Alarm 8

11. W1-C/W3-C Detailed Programming Guide 11.1 User Settings To enter the programming mode * Master code # To exit from the programming mode * 888888 is the default factory master code Note that to undertake the following programming the master user must be logged in To change the master code 0 New code # New code # The master code is any 6 digits Setting the working mode: Set valid card only users Set valid card and PIN users Set valid card or PIN users 3 0 # Entry is by card only 3 1 # Entry is by card and PIN together 3 2 # Entry is by either card or PIN (default) To add a user in either card or PIN mode ( 3 2 # ) (Default setting) To add a Pin user 1 User ID number # PIN # The ID number is any number between 1 ~ 2000. The PIN is any 4~8 digits between 0000 ~ 99999999 with the exception of 1234 which is reserved. Users can be added continuously without exiting from programming mode as follows: 1 User ID no 1 # PIN # User ID no 2 # PIN # To delete a PIN user 2 User ID number # Users can be deleted continuously without exiting programming mode To change the PIN of a PIN user (This step must be done out of programming mode) To add a card user (Method 1) This is the fastest way to enter cards using ID number auto generation. To add a card user (Method 2) * ID number # Old PIN # New PIN # New PIN # 1 Read card # Cards can be added continuously without exiting programming mode 1 ID number # Card # This is the alternative way to enter cards using User ID Allocation. In this 9

method a User ID is allocated to a card. Only one user ID can be allocated to a single card. To add card user (Method 3) Add a series cards users Block Enrollment To delete a card user by card number. Note users can be deleted continuously without exiting programming mode To delete a card user by user ID. This option can be used when a user has lost their card 5 ID number # 8 digits Card number # Card quantity # Card quantity is between 1 ~ 2000. The 8 digits card number is the last 8 digits on the card. Maximum 2000 cards can be enrolled at a stretch within 2 minutes. 2 Read Card # 2 User ID # To add a card and PIN user in card and PIN mode ( 3 1 # ) To Add a card and Pin user (The PIN is any 4~8 digits between 0000 & 99999999 with the exception of 1234 which is reserved.) To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselves To change a PIN in card and PIN mode (Method 2) Note that this is done outside programming mode so the user can undertake this themselves To delete a Card and PIN user just delete the card Add the card as for a card user Press * to exit from the programming mode Then allocate the card a PIN as follows: * Read card 1234 # PIN # PIN # * Read Card Old PIN # New PIN # New PIN # * ID number # Old PIN # New PIN # New PIN # 2 User ID # To add a card user in card mode ( 3 0 # ) To Add and Delete a card user The operating is the same as adding and deleting a card user in 3 2 # To delete All users 10

To delete ALL users. Note that this is a dangerous option so use with care 2 0000 # To set card users by Manager card To add user by Manager Add Card Manager add card Read card Manager add card Cards can be added continuously. To delete User by Manager Delete Card Manager delete card Read Card Manager delete card Cards can be deleted continuously. To unlock the door For a PIN user Enter the PIN then press # For a card User Read card For a card and PIN user Read card then enter PIN # 11.2 Door Relay, Door Detecting, Alarm Settings Door relay time setting To set door relay strike time 4 0~99 # The door relay time is between 0~99 seconds, the factory default setting is 5 seconds. Door Open Detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened by force, or if the door is opened after 20 seconds of the electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate. The Alarm Output time is adjustable between 0~3 minutes with the default being 1 minute. To disable door open detection. (Factory default) 6 0 # To enable door open detection 6 1 # Alarm output time To set the alarm output time (0~3 minutes) Factory default is 1 minute 9 0~3 # 11

Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN numbers in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10 minutes, depending on the option selected below. Normal status: No keypad lockout or alarm (factory default) 7 0 # (Factory default setting) Keypad Lockout 7 1 # Alarm Output 7 2 # To remove the alarm To reset the Door Forced Open warning Read valid card or Master Code # To reset the Door Open Too Long warning Close the door or Read valid card or Master Code # 12. Interconnecting Two Devices 12.1 W1-C/W3-C operating as a Wiegand Output Reader In this mode the W1-C/W3-C supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input. See figure 1. Figure 1 Transmission Format: 1: Keypad Transmission The Reader will transmit the PIN data when it receives the last key (#) press after PIN code. 12

Format: PIN Code (any 4~8 digits between 0000 ~ 99999999) Example: PIN code: 111111 Press 111111 #, then the output format will be: 00111111 (Note: if press an invalid PIN (any 4~8 digits), the data will be also transmitted.) 2: Proximity Card Transmission The Reader will transmit the card data when it reads the Card. Format: Card Number (the last 8 digits of Card Number) (Note: no matter the card is valid or invalid, the data will be transmitted) 12.2 W1-C/W3-C operating as a Controller In this mode the W1-C/W3-C supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the W1-C/W3-C. Either an ID card reader (125 KHZ) or an IC card reader (13.56MHZ) can be connected to the W1-C/W3-C. Cards are required to be added at the external reader, except where an external EM reader is used, in this case cards can be added at either reader or controller. See figure 2. Figure 2 13