Surge protection for frequency converters

Similar documents
Surge protection for gutter heating systems

Surge protection for LED mast lights

Lightning and surge protection for electromobility

Surge protection for telecommunication connections

BLITZDUCTOR XTU Universal lightning current / surge arrester

Lightning and surge protection for yachts

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

Lightning and surge protection for single-family houses

White Paper Surge protection for gutter heating systems

Lightning and surge protection for intelligent transformer substations

R3&A Limited, Cobourg, ON

Application-optimised DEHNshield Combined Arrester

POWER SUPPLY SYSTEMS SPDs for low-voltage installations and equipment

Surge Protection Devices Ex9UE2

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

INFORMATION TECHNOLOGY SYSTEMS

DEHN protects Biogas Plants.

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Coordinated Surge Protection

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Overvoltage Protection Devices

Overvoltage Protection Devices

wietap wietap Overvoltage Protection Tensions running high

DEHN protects Smart Power Grids.

White Paper. Lightning and surge protection for free field PV power plants. Contents

Overvoltage Protection Devices

DEHNsecure protects Direct Current Applications.

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

Overvoltage Protection Devices

White Paper. Lightning and surge protection for wind turbines. Contents

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Catalogue valid as of January 1,

DEHN protects Photovoltaic Systems.

VAL-CP-1S-175. Extract from the online catalog. Order No.:

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

PT 3-PB-ST. Extract from the online catalog. Order No.:

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Overvoltage Protection Devices

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

SPD Catalogue. SPD Catalogue. for AC applications

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

Lightning and Surge Arresters

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

VAL-CP-3S-350. Extract from the online catalog. Order No.:

White Paper Lightning and surge protection for rooftop photovoltaic systems

Surge Protection Devices and Surge Protection Kit

Type 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

Surge Protection Devices Type 1+2

DEHN tests and analyses DEHN Test Centre.

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

DEHN protects Photovoltaic Systems.

ETITEC - Lightning and Surge Arresters

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

QUINT-PS AC/24DC/10

ETD-BL-1T-OFF-CC- 10S

Overvoltage Protective Devices

A.3 Lightning and surge voltage protection

MINI-PS AC/10-15DC/8

Miniature Circuit-Breaker IEC Series 8562

Retrofitting sewage plants with lightning and surge protection measures

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

QUINT-PS/ 1AC/24DC/ 5

Lightning and Surge Arresters

Building Surge Protection Information Pack

STEP-PS/1AC/24DC/1.75

Surge Protective Device

MANUAL Surge Protectors

PHOENIX CONTACT Features

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

DEHN protects Wind Turbines.

DEHN protects Wind Turbines.

White Paper SV08/E/0812. Lightning and surge protection for wind turbines.

Power supply CP-C 24/5.0

Remote contact signaling available. visual status indication

Electronic timer CT-ERD.12

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

PHOENIX CONTACT - 01/2007

INFORMATION TECHNOLOGY SYSTEMS

interface Overvoltage Protection

SITOP in the SIMATIC Design

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

6/2 Product overview. 6/3 Lightning arresters, type 1. 6/5 Combination surge arresters, type 1 and type 2. 6/7 Surge arresters, type 2

Residual Current Devices drcm Digital

Overvoltage Protection for low-voltage supplies

Electronic timer CT-AHD.22

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Surge Protection for Low Voltage Power Systems

NEW surge protective devices

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

Transcription:

Surge protection for frequency converters White Paper Contents Basic principle of a frequency converter EMC-compatible shield connection of the motor feeder cable Frequency converter with drives in LPZ 0 A and LPZ 1 www.dehn-international.com

Surge protection for frequency converters White Paper A frequency converter typically consists of a rectifier, d.c. link, inverter and control electronics (Figure 1). At the inverter input, a single-phase a.c. voltage or threephase line-to-line a.c. voltage is converted into a pulsating d.c. voltage and is fed into the d.c. link which also serves as an energy storage system (buffer). Capacitors in the d.c. link and earthed L-C sections in the mains filter can cause problems with upstream residual current protective devices (RCDs). These problems are often incorrectly associated with surge arresters. They are, however, caused by short-time fault currents of the frequency converter which are sufficiently high to trip sensitive RCDs. This can be prevented by using a surge-proof RCD circuit breaker which is available with a discharge capacity of 3 ka (8/20 µs) and higher for a tripping current I n = 30 ma. The inverter provides a pulsed output voltage via the control electronics. The higher the pulse frequency of the control electronics for pulse width modulation, the more similar is the output voltage to a sinusoidal curve. However, with each pulse a voltage peak occurs that is superimposed on the fundamental wave. This voltage peak reaches values of more than 1200 V (depending on the frequency converter). The better the simulation of the sinusoidal curve, the better the run and control performance of the motor. This, however, means that voltage peaks occur more frequently at the output of the frequency converter. In order to pick the correct surge arrester for your frequency converter, the maximum continuous operating voltage U c must be taken into account which specifies the maximum permissible operating voltage a surge protective device may be connected to. Owing to the voltage peaks that occur during the operation of frequency converters, arresters with a high U c value must be used to avoid artificial ageing due to the heating of the surge arrester under normal operation conditions and the associated voltage peaks. Heating of surge arresters can lead to a shorter service life and a disconnection of the surge arrester from the installation it is supposed to protect. INT rectifier d.c. link inverter OUTT L1 + L2 C L3 V1 V3 + V5 V4 V6 V2 U1 V1 W1 motor M 3~ e.g. 4 20 ma data control electronics control / monitoring / communication Figure 1 Basic principle of a frequency converter large-area shield earthing at both ends by means of constant force spring of type SA KRF (Part No. 919 031 919 038) voltage supply frequency converter compact filter shielded motor feeder cable connection of the frequency converter to the filter motor metal mounting plate connected to earth in general: all lines must be as short as possible Figure 2 EMC-compatible shield connection of the motor feeder cable 2

Surge protection for frequency converters White Paper f1 f2 f1 f2 M 3~ No. Surge protective device Part No. DEHNguard modular DG M TNS 275 (TN-S system) 952 400 DEHNguard modular DG M TT 275 (TT system) 952 310 DEHNguard S DG S WE 600 (3 items) 952 077 DEHNbloc Maxi DBM 1 760 FM (3 items) + DEHNguard S DG S WE 600 (3 items) BLITZDUCTOR XT BXT ML2 BE S 24 (e.g. 4 20 ma) + BLITZDUCTOR XT base part BXT BAS Figure 3 Frequency converter with drives in LPZ 0 A and LPZ 1 M 3~ 961 175 + 952 077 920 224 + 920 300 The high pulse frequency at the output of the frequency converter causes field-based interference. To avoid that other systems are interfered with, the motor feeder cable must be shielded. The shield of the motor feeder cable must be earthed on both ends, namely at the frequency converter and at the motor. To this end, large-area contact with the shield must be provided, preferably by constant force springs (Figure 2), to fulfil EMC requirements. Intermeshed earth-termination systems, namely the connection of the earth-termination system of the frequency converter to that of the drive motor, reduce potential differences between the different parts of the installation, thus preventing equalising currents from flowing through the shield. When integrating a frequency converter in the building automation, all evaluation and communication interfaces must be protected by surge protective devices to prevent surge-related system failure. Figure 3 shows an example of the controller interface 4 20 ma. 3

DEHNbloc DBM 1 760 FM (961 175) Encapsulated non-exhausting spark gap High follow current extinction and limitation due to RADAX Flow technology Directly coordinated with DEHNguard surge protective devices without additional cable length Basic circuit diagram DBM 1 760 FM Coordinated single-pole lightning current arrester with high follow current limitation for U C = 760 V Type DBM 1 760 FM Part No. 961 175 SPD according to EN 61643-11 Type 1 SPD according to IEC 61643-1/-11 Max. continuous operating a.c. voltage (U C ) Lightning impulse current (10/350 µs) (I imp ) Specific energy (W/R) Nominal discharge current (8/20 µs) (I n ) Voltage protection level (U P ) Follow current extinguishing capability a.c. (I fi ) Follow current limitation / Selectivity Response time (t A ) Max. backup fuse (L) up to I K = 25 ka rms (t a 5 s) Max. backup fuse (L) up to I K > 25 ka rms Max. backup fuse (L-L') Temporary overvoltage (TOV) (U T ) TOV characteristic Operating temperature range (parallel connection) (T UP ) Operating temperature range (series connection) (T US ) Operating state/fault indication Class I 760 V 25 ka 156.25 kj/ohms 25 ka 4 kv 25 ka rms Dimension drawing DBM 1 760 FM no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) 100 ns 250 A gl/gg 100 A gl/gg 125 A gl/gg 1000 V / 5 sec. withstand -40 C...+80 C -40 C...+60 C green / red Number of ports 1 Cross-sectional area (L, L', 9) (min.) Cross-sectional area (L, 9) (max.) Cross-sectional area (L') (max.) 10 mm 2 solid/flexible 50 mm 2 stranded/35 mm 2 flexible 35 mm 2 stranded/25 mm 2 flexible 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 2 module(s), DIN 43880 Type of remote signalling contact a.c. switching capacity d.c. switching capacity Cross-sectional area for remote signalling terminals UL, CSA changeover contact 250 V/0.5 A 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A max. 1.5 mm 2 solid/flexible Customs tariff number 85363030 GTIN 4013364116283 508 g 1 pc(s) 4

DEHNguard DG M TT 275 (952 310) Prewired complete unit consisting of a base part and plug-in protection modules High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps High reliability due to "Thermo Dynamic Control" SPD monitoring device Basic circuit diagram DG M TT 275 Dimension drawing DG M TT 275 Modular surge arrester for use in TT and TN-S systems ("3+1" circuit). Type DG M TT 275 Part No. 952 310 SPD according to EN 61643-11 / IEC 61643-11 type 2 / class II Nominal a.c. voltage (U N ) 230 / 400 V (50 / 60 Hz) Max. continuous operating a.c. voltage [L-N] (U C ) 275 V (50 / 60 Hz) Max. continuous operating a.c. voltage [N-PE] (U C ) 255 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 20 ka Max. discharge current (8/20 µs) (I max ) 40 ka Lightning impulse current (10/350 µs) [N-PE] (I imp ) 12 ka Voltage protection level [L-N] (U P ) 1.5 kv Voltage protection level [L-N] at 5 ka (U P ) 1 kv Voltage protection level [N-PE] (U P ) 1.5 kv Follow current extinguishing capability [N-PE] (I fi ) 100 A rms Response time [L-N] (t A ) 25 ns Response time [N-PE] (t A ) 100 ns Max. mains-side overcurrent protection 125 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 50 ka rms Temporary overvoltage (TOV) [L-N] (U T ) Characteristic 335 V / 5 sec. withstand Temporary overvoltage (TOV) [L-N] (U T ) Characteristic 440 V / 120 min. safe failure Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 1200 V / 200 ms withstand Operating temperature range (T U ) -40 C... +80 C Operating state / fault indication green / red Number of ports 1 Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) 35 mm 2 stranded / 25 mm 2 flexible 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 4 module(s), DIN 43880 KEMA, VDE, UL, VdS 450 g Customs tariff number 85363030 GTIN 4013364108479 1 pc(s) 5

DEHNguard DG M TNS 275 (952 400) Prewired complete unit consisting of a base part and plug-in protection modules High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps High reliability due to "Thermo Dynamic Control" SPD monitoring device Modular surge arrester for use in TN-S systems. Basic circuit diagram DG M TNS 275 Dimension drawing DG M TNS 275 Type DG M TNS 275 Part No. 952 400 SPD according to EN 61643-11 / IEC 61643-11 type 2 / class II Nominal a.c. voltage (U N ) 230 / 400 V (50 / 60 Hz) Max. continuous operating a.c. voltage (U C ) 275 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 20 ka Max. discharge current (8/20 µs) (I max ) 40 ka Voltage protection level (U P ) 1.5 kv Voltage protection level at 5 ka (U P ) 1 kv Response time (t A ) 25 ns Max. mains-side overcurrent protection 125 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 50 ka rms Temporary overvoltage (TOV) (U T ) Characteristic 335 V / 5 sec. withstand Temporary overvoltage (TOV) (U T ) Characteristic 440 V / 120 min. safe failure Operating temperature range (T U ) -40 C... +80 C Operating state / fault indication green / red Number of ports 1 Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) 35 mm 2 stranded / 25 mm 2 flexible 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 4 module(s), DIN 43880 KEMA, VDE, UL, VdS 443 g Customs tariff number 85363030 GTIN 4013364108455 1 pc(s) 6

DEHNguard DG S WE 600 (952 077) Multi-purpose surge arrester consisting of a base element and plug-in protection module High discharge capacity due to heavy-duty zinc oxide varistor High reliability due to "Thermo Dynamic Control" SPD monitoring device Basic circuit diagram DG S WE 600 Dimension drawing DG S WE 600 Pluggable single-pole surge arrester with a rated varistor voltage U mov = 750 V a.c., consisting of base part and plug-in protection module; FM version with floating remote signalling contact. Type DG S WE 600 Part No. 952 077 SPD according to EN 61643-11 / IEC 61643-11 type 2 / class II Nominal a.c. voltage (U N ) 480 V (50 / 60 Hz) Max. continuous operating a.c. voltage (U C ) 600V (50 / 60 Hz) Rated varistor voltage a.c. (U mov ) 750 V Nominal discharge current (8/20 µs) (I n ) 15 ka Max. discharge current (8/20 µs) (I max ) 25 ka Voltage protection level (U P ) 3 kv Voltage protection level at 5 ka (U P ) 2.5 kv Response time (t A ) 25 ns Max. mains-side overcurrent protection 100 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 25 ka rms Temporary overvoltage (TOV) (U T ) Characteristic 900 V / 5 sec. withstand Temporary overvoltage (TOV) (U T ) Characteristic 915 V / 120 min. safe failure Operating temperature range (T U ) -40 C... +80 C Operating state / fault indication green / red Number of ports 1 Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) 35 mm 2 stranded / 25 mm 2 flexible 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 1 module(s), DIN 43880 KEMA, UL, CSA, VdS 137 g Customs tariff number 85363030 GTIN 4013364119680 1 pc(s) 7

BLITZDUCTOR XT BXT ML2 BE S 24 (920 224) LifeCheck SPD monitoring function Optimal protection of two single lines and the cable shield For use in conformity with the lightning protection zone concept at the boundaries from 0 A 2 and higher Basic circuit diagram BXT ML2 BE S 24 Dimension drawing BXT ML2 BE S 24 Space-saving combined lightning current and surge arrester module with LifeCheck feature for protecting two single lines sharing a common reference potential as well as unbalanced interfaces, with direct or indirect shield earthing. If LifeCheck detects thermal or electrical overload, the arrester has to be replaced. This status is indicated contactlessly by the DEHNrecord LC / SCM / MCM reader. Type BXT ML2 BE S 24 Part No. 920 224 SPD monitoring system LifeCheck SPD class Nominal voltage (U N ) 24 V Max. continuous operating d.c. voltage (U C ) 33 V M Max. continuous operating a.c. voltage (U C ) 23.3 V Nominal current at 45 C (I L ) 0.75 A D1 Total lightning impulse current (10/350 µs) (I imp ) 9 ka D1 Lightning impulse current (10/350 µs) per line (I imp ) 2.5 ka C2 Total nominal discharge current (8/20 µs) (I n ) 20 ka C2 Nominal discharge current (8/20 µs) per line (I n ) 10 ka Voltage protection level line-line for I imp D1 (U p ) 102 V Voltage protection level line-pg for I imp D1 (U p ) 66 V Voltage protection level line-line at 1 kv/µs C3 (U p ) 90 V Voltage protection level line-pg at 1 kv/µs C3 (U p ) 45 V Series resistance per line 1.8 ohm(s) Cut-off frequency line-pg (f G ) 6.8 MHz Capacitance line-line (C) Capacitance line-pg (C) 0.5 nf 1.0 nf Operating temperature range (T U ) -40 C... +80 C Degree of protection (plugged-in) IP 20 Pluggable into Earthing via BXT BAS / BSP BAS 4 base part BXT BAS / BSP BAS 4 base part Enclosure material polyamide PA 6.6 Test standards yellow IEC 61643-21 / EN 61643-21, UL 497B SIL classification up to SIL3 * ) ATEX approvals IECEx approvals CSA & USA Hazloc approvals (1) CSA & USA Hazloc approvals (2) DEKRA 11ATEX0089 X: II 3 G Ex na IIC T4 Gc DEK 11.0032X: Ex na IIC T4 Gc 2516389: Class I Div. 2 GP A, B, C, D T4 2516389: Class I Zone 2, AEx na IIC T4 CSA, GOST, VdS 37 g Customs tariff number 85363010 GTIN 4013364117785 1 pc(s) * ) For more detailed information, please visit www.dehn-international.com. 8

BLITZDUCTOR XT BXT BAS (920 300) Four-pole version for universal use with all types of BSP and BXT / BXTU protection modules No signal interruption if the protection module is removed Universal design without protection elements Basic circuit diagram with and without plugged-in module Dimension drawing BXT BAS The BLITZDUCTOR XT base part is a very space-saving and universal four-pole feed-through terminal for the insertion of a protection module without signal interruption if the protection module is removed. The snap-in mechanism at the supporting foot of the base part allows the protection module to be safely earthed via the DIN rail. Since no components of the protective circuit are situated in the base part, only the protection modules must be maintained. Type BXT BAS Part No. 920 300 Operating temperature range (T U ) -40 C... +80 C Degree of protection IP 20 35 mm DIN rails acc. to EN 60715 Connection (input / output) Signal disconnection screw / screw Cross-sectional area, solid 0.08-4 mm 2 Cross-sectional area, flexible 0.08-2.5 mm 2 Tightening torque (terminals) no 0.4 Nm Earthing via 35 mm DIN rails acc. to EN 60715 Enclosure material polyamide PA 6.6 ATEX approvals DEKRA 11ATEX0089 X: II 3 G Ex na IIC T4 Gc * ) IECEx approvals DEK 11.0032X: Ex na IIC T4 Gc * ) yellow CSA, VdS, UL, GOST Customs tariff number 85369010 GTIN 4013364109179 * ) only in connection with an approved protection module 34 g 1 pc(s) 9

Shield Connection / Constant Force Spring Type SA KRF 10 V2A Part No. 919 031 Lightning impulse current carrying capability (10/350 µs) 10 ka Clamping range (Rd) 4-10 mm T12-04-ETL 003 2 g GTIN 4013364103511 20 pc(s) Type SA KRF 15 V2A Part No. 919 032 Lightning impulse current carrying capability (10/350 µs) 10 ka Clamping range (Rd) 9-15 mm 2 g GTIN 4013364103528 20 pc(s) Type SA KRF 22 V2A Part No. 919 033 Lightning impulse current carrying capability (10/350 µs) 10 ka Clamping range (Rd) 14-22 mm 5 g GTIN 4013364103535 20 pc(s) Type SA KRF 29 V2A Part No. 919 034 Lightning impulse current carrying capability (10/350 µs) 10 ka Clamping range (Rd) 18.5-29 mm 7 g GTIN 4013364103542 10 pc(s) 10

Shield Connection / Constant Force Spring For solderless connection of a conductor to the shield For use with all plastic and lead-sheathed cables Also suitable for steel-reinforced lead-sheathed cables Constant force springs allow solderless shield connections for equipotential bonding or lightning equipotential bonding. They can be installed subsequently without interrupting the cable shield or requiring tools for installation. Approved for nuclear plants according to TÜV Certificate No. (TÜV = German Technical Inspectorate). Type SA KRF 37 V2A Part No. 919 035 Lightning impulse current carrying capability (10/350 µs) 10 ka Clamping range (Rd) 23.5-37 mm 1 g GTIN 4013364103559 10 pc(s) Type SA KRF 50 V2A Part No. 919 036 Lightning impulse current carrying capability (10/350 µs) 10 ka Clamping range (Rd) 31-50 mm 23 g GTIN 4013364103566 25 pc(s) Type SA KRF 70 V2A Part No. 919 037 Lightning impulse current carrying capability (10/350 µs) 10 ka Clamping range (Rd) 44-70 mm GTIN 4013364103573 50 g 20 pc(s) Type SA KRF 94 V2A Part No. 919 038 Lightning impulse current carrying capability (10/350 µs) 10 ka Clamping range (Rd) 58-94 mm GTIN 4013364103580 82 g 10 pc(s) 11

www.dehn-international.com/partners Surge Protection DEHN + SÖHNE Hans-Dehn-Str. 1 Tel. +49 9181 906-0 Lightning Protection GmbH + Co.KG. Postfach 1640 Fax +49 9181 906-1100 Safety Equipment 92306 Neumarkt info@dehn.de DEHN protects. Germany www.dehn-international.com www.dehn-international.com/partners Type designations of products mentioned in the white paper being at the same time registered trademarks are not especially marked. So if there is no marking of or this does not mean that the type designation is a free trade name. Neither it can be seen whether patents or utility models and other intellectual and industrial property rights are available. We reserve the right to introduce changes in performance, configuration and technology, dimensions, weights and materials in the course of technical progress. The figures are shown without obligation. Misprints, errors and modifications excepted. Reproduction in any form whatsoever is forbidden without our authorisation. activsense, BLITZDUCTOR, BLITZPLANER, DEHN, DEHN Logo, DEHN schützt, DEHNbloc, DEHNfix, DEHNgrip, DEHNguard, DEHNport, DEHNQUICK, DEHNrapid, DEHNshield, DEHNsnap, DEHNventil, HVI, LifeCheck, Red/Line are protected by German Trade Mark, by Community Trade Mark (EU) and/or in other countries.