B100-SA Standalone Biometric Reader

Similar documents
DINB100-SA Standalone Biometric Reader

DINB100-SA Standalone Biometric Reader

B100PROX-MF-SA Standalone Biometric Mifare Reader USER S MANUAL. Relay1 time (for Relay 1 in B100PROX-MF-SA,RU2, RTT and DINRTT )

DINB100-SA-KIT Standalone Biometric Kit

CV-945 Stand-Alone Biometric Reader. Installation Instructions

EX8. User Manual. Ver 1.0

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

B100PROX-EH(AH) Biometric Proximity Reader INSTALLER MANUAL

BIOPAD-M Biometric Keypad Reader User s Manual

BIOPROX-MF V1 Biometric Mifare Reader

BIOPAD-M V1. Biometric keypad reader INSTALLER MANUAL. v.b2

DINBIOC3 V1 USER S MANUAL. EN Biometric Reader. v.b2

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

Fingerprint Access Control F1. User Manual

CM-110SK Standalone Keypad Installation Instructions

DOLXFD1000B. Waterproof Access Control/Reader

Waterproof. Keypad/Reader/Controller

EL-ST100 KEYPAD CONTROLLER

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

W3-H Waterproof Keypad/Reader/Controller

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

VIS-3200 / VIS-3201 User Manual

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

Single Door Standalone Access Control User Manual

REX F-0-9 Standalone or Access Controller

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

Operation manual For NG BIOSINGLE Version 1.1

W3-M. Metal waterproof standalone access control/reader. User Manual

Digital Keypad Introduction

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

DG-800 Stand-Alone Proximity Reader Instruction Manual

VIDI-AC-2CS Access Controller/ Reader

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

RBR-SB-KTZ001 LAR 2. User Manual

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

GV-AS Controller. Installation Guide

User Manual. PCKeypad Wireless Keypad

PR602LCD v1.0 Installer Manual Rev. A

Stand-alone Proximity Access Control

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

FTK5 PROXIMITY KEYPAD

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

GV-Card Reader. User s Manual

CM-500 SK 500 USER CODES KEYPAD

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

Fingerprint Identification Proximity Reader. Quick Installation Guide

RXTH DUAL ROOM SENSOR / SWITCH

User Manual. Split access control with intelligent secured power supply.

RFT1000 reader in RACS 5. User Manual

_ Access control SISTEMAS DE SEGURIDAD

4 Wire Video Intercom System

Access control panel U-Prox IC E (Elevator control)

DO NOT LOSE THIS SHEET - YOUR FACTORY MASTER CODE IS UNIQUE TO YOUR KEYPAD

INSTALLATION GUIDE BioLite Net English Version 2.10 EN BLN V2.10A

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

BIO-PRO Standalone / Weigand fingerprint reader

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

KP2000E/EM Series Style Keypad

1. Product Specification

Xpass S2. Installation Guide. Intelligent IP Access Control Reader EN XPS2 V1.11.

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Installation Guide for PR311SE and PR311SE-BK v1.0 Access Controllers Rev. B

Specifications: Features:

DT-AKP 2 WIRE SYSTEM. User Manual. Access keypad panel with scramble keypad DT-ENG-AKP-V1 /

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

Biometric finger print entry system.

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

RXTP ROOM TEMPERATURE

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

ACCESS CONTROL SYSTEM

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

GV-AS/EV Controller. User s Manual

Installation Guide (ver 1.0)

GV-RK1352 and GV-R1352 Card Reader

INSTALLATION GUIDE BioEntry Plus English Version 2.11 EN BEP V2.11A

Gallagher T12 Reader. Installa on Note. The Gallagher T12 Reader

BC Digital Keypad. User Manual

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

INSTALLATION GUIDE BioEntry W English Version 2.10 EN BEW V2.10A

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

AS Keypad User Manual

2000 Series e/em Style Keypad Installation and Programming Manual

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Installation and User Manual

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

Transcription:

EN B100-SA Standalone Biometric Reader User Manual v.b1

Contents 1.0 INTRODUCTION 2.0 MOUNTING 3.0 SPECIFICATIONS......... 3 3 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING... 4 6.0 RECOMMENDED SWIPING TECHNIQUE... 5 6.1 Tapping the sensor... 5 6.2 Scrolling the sensor up and down... 5 7.0 INDICATION... 5 8.0 QUICK PROGRAMMING... 6 8.1 Adding Master Finger and delete all users... 6 8.2 Add User In Group 1 8.3 Add User In Group 2... 7... 7 8.4 Delete user... 7 8.5 Delete All Users in Group 1 8.6 Delete All Users in Group 2...... 7 7 9.0 PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT... 8 9.1 Pairing B100-SA with DINRTT 9.2 Pairing B100-SA with RTT... 8... 8 10.0 KEEP THE DOOR UNLOCK... 8 11.0 B100-SA PROGRAMMING MENU... 9 11.1 Adding Users 11.2 Delete User 11.3 Delete All users... 9... 10... 10 11.4 Delete Group of Users 11.5 Add Administrator 11.6 Delete Administrator... 11... 12... 13 11.7 Settings... 14 11.7.1 Double Swipe Unlocks Door, Entry Mode, Remote Relay Touch Function... 15 11.7.2 Buzzer Sound, Backlight, Reset to defaults... 16 11.8 Set Door Relay Time... 17 2

1.0 INTRODUCTION B100-SA is a simple one-door standalone biometric system. The reader can store up to 97 finger templates, it has one relay output and one exit button input. If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of request-to-exit push button. Complete setup and programming can be done by scrolling and tapping on the sensor. The sensor incorporates dedicated sensing hardware to facilitate the detection of spoofing attacks based on fake fingers. This data is embedded into the image data stream, and is processed on the processor. The system is capable of detecting and defeating well-known fake finger mechanisms, such as molded gummy fingers. The coating on the surface of the TouchChip sensor provides protection from scratching and abrasion due to normal contact with fingertips and any incidental contact with fingernails. 2.0 MOUNTING 1. 2. 3. 4. MC-MINI Ø6.0(3NoS) 30mm Cable 5mm 3 (3 x 30mm) 1 (M3 x 6mm) Do not install the device and cabling close to a source of strong electro-magne c fields like radio-transmi ng antenna. Do not place the device near or above hea ng equipments. If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel. Do not let children touch the device without supervision. Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered. If the biometric reader is installed and used outdoor, the reader MUST be fi ed with the MC-MINI metal cover available in our accessories in order to protect the sensor from direct rainfall. The opera ng temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box (fi ed with addi onal heater if very low temperature) to keep a constant sensor level performance. XPR cannot guarantee the func onality of the product if measures and advice before are not followed. It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use different readers depending on users. 3.0 SPECIFICATIONS Fingerprint Capacity: Output: Push Button Input: Door Open Time: Entry Mode: Programming: Master/Admin Fingers: Image resolution: Backlight ON/OFF: Buzzer ON/OFF: Firmware upgrade: Current Consumption: Power Supply: Indication: Mounting: IP Factor: Storage/Operating Temperature : Storage/Operating Humidity: Dimensions(mm): 97 templates 1 x Relay ( 1 A /24V AC/DC) Yes Pulse (1, 3, 5, 10, 20, 30, 60sec) or Toggle(ON/OFF) Finger By scrolling and tapping on the sensor or by keypad 1 Master and 2 Admin Fingers Up to 508 DPI Yes Yes via RS485 converter and windows application 100 ma max. 9-14 V DC Tricolor Status LED and 4 x Programming LEDs Flush mount IP65-20 C to +50 C 5% to 93% RH without condensation 92 x 51 x 25 3 51mm 92mm B100-SA 25mm

4.0 APPLICATION DIAGRAM DINRTT (Op onal) 2 Relay Remote Unit and request-to-exit Bu on OR RS485 (max. 50m) Outside Area RTT (Op onal) 1 Relay Remote Unit and request-to-exit Bu onsecured B100-SA Standalone Biometric Reader 5.0 WIRING Red Black Pink Violet Blue Green Orange Gray Yellow White 12V DC GND A RS485 B Tamp PB NC COM NO Colour Red Black Green Blue Orange Pink Violet Grey Yellow White Connection 12V DC GND Tamper Tamper Push Button A (RS485) B (RS485) NC COM NO Relay (1A) _ + 12VDC POWER SUPPLY Red Black Pink Violet Blue Green Orange Gray Yellow White + _ PB NC COM GND (PB) 1N4001 Diode _ + Electro Magnetic Lock 4

6.0 RECOMMENDED SWIPING TECHNIQUE 6.1 Taping the sensor Tap the sensor to enter Submenu or to confirm a command Follow the below instructions for correct finger swiping Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement. Result: For a valid swipe: Tricolour Status LED turns green + (short + long beep) For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps) Enter and confirm 6.2 Scrolling the sensor up and down Scroll the sensor DOWN to navigate the programming menu Navigate the Programming Menu Scroll the sensor UP to exit the programming menu Exit the Programming Menu 7.0 INDICATION Tricolor Status LED Green - Access Granted Red - Access denied Orange - Idle Mode 4 x Tricolor Programming LEDs (red, green, orange) - short + long beep Error Beep - 3 short beeps Swipe Again - 2 short beeps 5

8.0 QUICK PROGRAMMING 8.1 Adding Master Finger and delete all users 1.Push dip switch no.2 in position ON. 2.Reset the Power of the device. 3.Wait for One long + mul ple short beeps 4.Put the dip switch in position OFF. (short beeps will stop) 5.Wait for the bo om row LEDs to blink in Orange. ON 1 2 ON 1 2 No.2 No.2 Blinking> <Blinking 6.Swipe the Master finger min.6 mes. (Un l Ok Beep) x 6 Note: A er enrolling the Master finger the device will auto-reset (wait for 7 seconds and the OK beep). Note: This procedure also deletes all the users and administrators previously enrolled. 1. There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. The Master finger can be changed ONLY with the jumper. 2. There are 2 Administrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master. 3. The User can be assigned to one of the 8 available User Groups. With the Quick programming feature, the Users are assigned in Group 1 or Group 2. For most of the installa ons 2 groups are enough and can be used as: Group 1 for permanent residents, Group 2 for guest and visitors. 4. The user can be deleted by swiping its user finger or by dele ng the group in which that user is enrolled. Once the Group of users is deleted, all the users within that group will be deleted. 5. The Groups are not limited by the number of users. (ex. Group 1 can contain 20 users, Group 2 can contain 70 users, but the total number must remain bellow 97...) 6

8.2 Add User In Group 1 Figure.1 1. Swipe the Master or Admin Finger 2. Swipe the user finger min. 6 mes (un l Ok Beep) Master Finger x 1 User Finger x 6 8.3 Add User In Group 2 Figure.2 1. Swipe the Master or Admin Finger twice 2. Swipe the user finger min. 6 mes (un l Ok Beep) Master Finger x 2 User Finger x 6 8.4 Delete User Figure.1 1. Swipe the Master or Admin Finger 2. Swipe the user finger (already enrolled) Master Finger x 1 User Finger x 1 8.5 Delete All Users in Group 1 6 sec. Figure.4 1. Swipe the Master or Admin finger 3 mes, 2. Wait 6 seconds for the light pa ern on figure.4 3. Swipe the Master or Admin finger once more Note: All fingers that are enrolled in Group 1 will be deleted. Master Finger x 3 wait 6 seconds Master Finger x 1 8.6 Delete All Users in Group 2 6 sec. Figure.6 1. Swipe the Master or Admin finger 4 mes, 2. Wait 6 seconds for the light pa ern on figure.6 3. Swipe the Master or Admin finger once more Note: All fingers that are enrolled in Group 2 will be deleted. Master Finger x 4 wait 6 seconds Master Finger x 1 If you make any mistake or you just simply want to exit Quick Programming, wait for the meout of 10 seconds. With this, the quick programming is completed. The system is now opera onal with default value for Door Open Time of 3 seconds. For more comprehensive programming, refer to the B100-SA Programming sec on. 7

A 9.0 PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay s Manual. 9.1 Pairing B100-SA with DINRTT 12 VDC + - 1N4007 + - 1 2 DINRTT NO1 NO1 COM COM NC1 NO2 COM NC2 1. Close the Jumper. DINRTT beeps con nuously and the red led blinks. 2. Open the Jumper 3. Wait for Beep + (short + short + long beep) Exit Button (NO) GND PB1 GND PB1 GND PB2 GND +12V GND +12V B RS485 B RS485 TAMP TAMP A er the OK beep, the coupling is done. GND +12V Black Red Pink Violet GND +12V B (RS485) A (RS485) - + 12 VDC 9.2 Pairing B100-SA with RTT 12 VDC - + Black Red Yellow Black COM GND White NO 1N4007 + - Red Brown 12V out Pink Pink A (RS485) Violet Violet B (RS485) ON 1 2 B100-SA 1. Put Dipswitch No.1 to posi on ON. RTT beeps con nuously and the red led blinks. 2. Put Dipswitch No.1 to posi on OFF. 3. Wait for Beep + (short + short + long beep) A er the OK beep, the coupling is done. RTT 10.0 KEEP THE DOOR UNLOCKED Swipe ANY enrolled finger twice (within 7 seconds) and the Door will stay unlocked, un l valid finger is swiped. While the door is unlocked the tricolor status LED stays green. User Finger x 2 To use this feature, enable the same from the menu.(page 15). It applies for product version 1.0.2.0.0 and above. Note: Make sure that the door lock can withstand ac va on in longer periods. 8

11.0 B100-SA PROGRAMMING MENU 11.1 Adding Users Swipe the Master/Admin finger 5 mes un l the light pa ern on figure.9 is shown Figure.9 x 5 Select User Group Swipe the finger to select: Group 1 Group 5 Group 2 Group 6 Group 3 Group 4 Group 7 Group 8 Assign Relay Output Swipe the finger to select: Relay 1 Both Relay 2 None NOTE: Swipe UPWARDS to exit the MENU (Orange Blinking) Swipe the user finger for Finger mode min.6 mes. x 6 Example: Task: Add a user in Group2, that will ac vate Relay1. Scroll Master Finger 5 mes, tap, scroll ones, tap, tap, swipe user finger 6 mes, swipe UP to exit. 9

11.0 B100-SA PROGRAMMING MENU 11.2 Delete User Swipe the Master/Admin finger 7 mes un l the light pa ern on figure.12 is shown Figure.12 x 7 Blinking row > Swipe finger NOTE: Swipe UPWARDS to exit the MENU 11.3 Delete All Users Swipe the Master/Admin finger 11 mes un l the light pa ern on figure.14 is shown Figure.14 x 11 Blinking row > to confirm or swipe UP to Cancel NOTE: Swipe UPWARDS to exit the MENU deleting... 10 Note: The Master and the Administrators will not be deleted

11.0 B100-SA PROGRAMMING MENU 11.4 Delete Group of Users Swipe the Master/Admin finger 6 mes un l the light pa ern on figure.13 is shown Figure.13 x 6 Select User Group to Delete Swipe the finger to select: Group 1 Group 5 Group 2 Group 6 Group 3 Group 4 Group 7 Group 8 NOTE: Swipe UPWARDS to exit the MENU Note: All fingers that are enrolled in the Group will be deleted. Example: Task: Delete all users in Group3 Scroll Master Finger 6 mes, tap, scroll twice, tap, swipe UP to exit. 11

11.0 B100-SA PROGRAMMING MENU 11.5 Add Administrator Swipe the Master/Admin finger 12 mes un l the light pa ern on figure.10 is shown Figure.10 x 12 Select Admin nr. Scroll down to select: Admin 1 Admin 2 (Orange Blinking) Swipe the Admin finger min.6 mes.(un l Ok beep) x 6 (to Add User menu) NOTE: Swipe UPWARDS to exit the MENU - There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. - The Master finger can be changed ONLY with the jumper. - There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master. 12

11.0 B100-SA PROGRAMMING MENU 11.6 Delete Administrator Swipe the Master/Admin finger 13 mes un l the light pa ern on figure.11 is shown Figure.11 x 13 Select Admin nr. Scroll down to select: Admin 1 Admin 2 deleting.. NOTE: Swipe UPWARDS to exit the MENU - There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. - The Master finger can be changed ONLY with the jumper. - There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master. 13

11.0 B100-SA PROGRAMMING MENU 11.7 Se ngs Swipe the Master/Admin finger 10 mes un l the light pa ern on figure.7 is shown Figure.7 x 10 Blinking row > By swiping finger select appropriate light pa ern Swipe the finger to select: Double Swipe Unlocks Door Remote Relay Touch Function Sensor security Buzzer Entry mode Backlight Reset to defaults Continues on the next 2 pages go to next page NOTE: Swipe UPWARDS to exit the MENU Entry Mode - used when addi onal proximity or keypad reader is connected Remote Relay Touch Func on - Enabling/Disabling the Touch Bu on Func on in the remote relay Unit Buzzer - Enabling/Disabling the Buzzer Backlight - Enabling/Disabling the Backlight 14

11.0 B100-SA PROGRAMMING MENU 11.7 Se ngs 11.7.1 Double Swipe Unlocks Door, Entry Mode, Remote Relay Touch Func on Double Swipe Unlocks Door Entry MODE Remote Relay Touch Function Double Swipe Unlocks Door Scroll down to select: By swiping finger select entry mode Scroll down to select: Touch Button ON/OFF Scroll down to select: 1 ON 2 OFF Finger Finger OR PIN Finger AND PIN Finger AND Card Finger ON Card 1 ON 2 OFF product ver. 1.0.2.0.0 Finger OR Card Note: Refer to Chapter 10 for this feature NOTE: Swipe UPWARDS to exit the MENU Example: Task: Set the Reader to work in Finger and Card mode Scroll Master Finger 10 mes, tap, scroll twice, tap, scroll 4 mes, tap, swipe UP to exit. 15

11.0 B100-SA PROGRAMMING MENU 11.7 Se ngs 11.7.2 Buzzer Sound, Backlight, Reset to defaults Buzzer sound Backlight Reset to defaults Buzzer ON/OFF Scroll down to select: Remote OFF Reader OFF All ON All OFF Backlight ON/OFF Scroll down to select: Remote OFF Reader OFF All ON All OFF Reset to defaults Tap to confirm: product ver. 1.0.2.0.0 Note: Does not affect the fingerprints stored and the pairing NOTE: Swipe UPWARDS to exit the MENU Example: Task: Put the Buzzer OFF. Scroll Master Finger 10 mes, tap, scroll 4 mes, tap, scroll ones, tap,, swipe UP to exit. 16

11.0 B100-SA PROGRAMMING MENU 11.8 Set Door Relay Time Relay1 time (for Relay 1 in B100-SA, RTT and DINRTT ) Relay2 time (for Relay 2 in DINRTT Remote Relay Unit) Swipe the Master/Admin finger 8 times x 8 Swipe the Master/Admin finger 9 mes x 9 Blinking row > Blinking row > Select relay open time Select relay open time Scroll down to select: Scroll down to select: 1 sec 20 sec 1 sec 20 sec 3 sec 30 sec 3 sec 30 sec 5 sec 10 sec 60 sec Toggle 5 sec 10 sec 60 sec Toggle NOTE: Swipe UPWARDS to exit the MENU Example: Task: Put Relay1 to stay ac vated 10 seconds. Scroll Master Finger 8 mes, tap, scroll 3 mes, tap, swipe UP to exit. 17

18

19

This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS directive EN50581:2012 Visual Plus Corporation, s.a. Drève Richelle 161 WOP G - Bte 34 1410 Waterloo - Belgium 20