ENHANCEMENT OF DIFFUSERS BRDF ACCURACY

Similar documents
Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

IMAGING SPECTROMETER DATA CORRECTION

Dr. Larry J. Paxton Johns Hopkins University Applied Physics Laboratory Laurel, MD (301) (301) fax

Spectrophotometric Methods of Refractive Indices Measurement

D&S Technical Note 09-2 D&S A Proposed Correction to Reflectance Measurements of Profiled Surfaces. Introduction

Interactive comment on Quantification and mitigation of the impact of scene inhomogeneity on Sentinel-4 UVN UV-VIS retrievals by S. Noël et al.

Polarization Ray Trace, Radiometric Analysis, and Calibration

Imaging Sphere Measurement of Luminous Intensity, View Angle, and Scatter Distribution Functions

Wat is licht, wat is meten? Belgisch Perspectief! Spectraal of niet-spectraal meten: that s the question

MERIS solar diffuser BRDF modelling. Gerhard Meister and Ewa Kwiatkowska

Hyperspectral Remote Sensing

specular diffuse reflection.

CRISM (Compact Reconnaissance Imaging Spectrometer for Mars) on MRO. Calibration Upgrade, version 2 to 3

Philpot & Philipson: Remote Sensing Fundamentals Interactions 3.1 W.D. Philpot, Cornell University, Fall 12

GOCI Post-launch calibration and GOCI-II Pre-launch calibration plan

ENMAP RADIOMETRIC INFLIGHT CALIBRATION

WORCESTER POLYTECHNIC INSTITUTE

The Council for Optical Radiation Measurements (CORM), NIST July 30 - Aug 1, 2018

Optical Scattering. Analysis. Measurement and SPIE PRESS. John C. Stover THIRD EDITION. Bellingham, Washington USA

Optics Vac Work MT 2008

Applicability of itirm for roughness reduction monitoring

Engineered Diffusers Intensity vs Irradiance

Scattering measurements. Guidelines for measurements service

Light Tec Scattering measurements guideline

MODULE 3 LECTURE NOTES 3 ATMOSPHERIC CORRECTIONS

Sentinel-2/Landsat-8 Characterization and Cross - Cal

Validation of the Gonioreflectometer

GODDARD SPACE FLIGHT CENTER. Future of cal/val. K. Thome NASA/GSFC

Introduction to Diffraction Gratings

Improvements to Ozone Mapping Profiler Suite (OMPS) Sensor Data Record (SDR)

Light Tec Scattering measurements guideline

Light Tec Scattering measurements guideline

Multi-sensors vicarious calibration activities at CNES

Evaluation of Satellite Ocean Color Data Using SIMBADA Radiometers

Diffraction Efficiency

SUPPLEMENTARY INFORMATION

Mu lt i s p e c t r a l

Reflective Illumination for DMS 803 / 505

Wallace Hall Academy

SIMULATION AND VISUALIZATION IN THE EDUCATION OF COHERENT OPTICS

MODULE 3. FACTORS AFFECTING 3D LASER SCANNING

Council for Optical Radiation Measurements (CORM) 2016 Annual Technical Conference May 15 18, 2016, Gaithersburg, MD

PHYS 3410/6750: Modern Optics Midterm #2

Light Tec Scattering measurements guideline

GEOG 4110/5100 Advanced Remote Sensing Lecture 2

Removing Systematic Errors from Rotating Shadowband Pyranometer Data

Calibration Techniques for NASA s Remote Sensing Ocean Color Sensors

CARBON NANOTUBE FLAT PLATE BLACKBODY CALIBRATOR. John C. Fleming

Control of Light. Emmett Ientilucci Digital Imaging and Remote Sensing Laboratory Chester F. Carlson Center for Imaging Science 8 May 2007

Radiance, Irradiance and Reflectance

Light Tec. Characterization of ultra-polished surfaces in UV and IR. ICSO October 2016 Biarritz, France

MODELING LED LIGHTING COLOR EFFECTS IN MODERN OPTICAL ANALYSIS SOFTWARE LED Professional Magazine Webinar 10/27/2015

AP* Optics Free Response Questions

Spectrographs. C. A. Griffith, Class Notes, PTYS 521, 2016 Not for distribution.

Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements

Use of the surface PSD and incident angle adjustments to investigate near specular scatter from smooth surfaces

Chemistry Instrumental Analysis Lecture 6. Chem 4631

Winmeen Tnpsc Group 1 & 2 Self Preparation Course Physics UNIT 9. Ray Optics. surface at the point of incidence, all lie in the same plane.

Reproducing the hierarchy of disorder for Morpho-inspired, broad-angle color reflection

BROADBAND SPECTRAL-POLARIMETRIC BRDF SCAN SYSTEM AND DATA FOR SPACECRAFT MATERIALS

Silicon Avalanche Photodiodes in Dynamic Light Scattering

To see how a sharp edge or an aperture affect light. To analyze single-slit diffraction and calculate the intensity of the light

Polarized Downwelling Radiance Distribution Camera System

Introduction. Lab Kit Contents

Comparison of BRDF-Predicted and Observed Light Curves of GEO Satellites. Angelica Ceniceros, David E. Gaylor University of Arizona

Technical Overview. Introduction

High spatial resolution measurement of volume holographic gratings

Effective Medium Theory, Rough Surfaces, and Moth s Eyes

CfE Higher Physics. Particles and Waves

Spectrometers: Monochromators / Slits

Component Level Prediction Versus System Level Measurement of SABER Relative Spectral Response

Particles and Waves Final Revision Exam Questions Part 2

Experimental Observation of Invariance of Spectral Degree of Coherence. with Change in Bandwidth of Light

Interference with polarized light

WHITE PAPER. Application of Imaging Sphere for BSDF Measurements of Arbitrary Materials

Optical Topography Measurement of Patterned Wafers

New capabilities of diffuser calibration lab at GSFC NASA to support remote sensing instrumentation

Menghua Wang NOAA/NESDIS/STAR Camp Springs, MD 20746, USA

LC-1: Interference and Diffraction

Chapter 24. Geometric optics. Assignment No. 11, due April 27th before class: Problems 24.4, 24.11, 24.13, 24.15, 24.24

Instruction manual for T3DS calculator software. Analyzer for terahertz spectra and imaging data. Release 2.4

IASI spectral calibration monitoring on MetOp-A and MetOp-B

C101-E137 TALK LETTER. Vol. 14

BLACKOUT FLEX BB TECHNICAL DATA SHEET » ARTICLE CODE» WIDTH» LENGTH» WEIGHT » COMPOSITION » FLAME RESISTANCE » AVAILABLE COLOURS.

Quantifying the Dynamic Ocean Surface Using Underwater Radiometric Measurements

10.4 Interference in Thin Films

Coupling of surface roughness to the performance of computer-generated holograms

ACS/WFC Crosstalk after Servicing Mission 4

Geometrical modeling of light scattering from paper substrates

EM Waves Practice Problems

Modeling of the ageing effects on Meteosat First Generation Visible Band

BEAM TILTED CORRELATIONS. Frank Vignola Department of Physics University of Oregon Eugene, OR

Plane Wave Imaging Using Phased Array Arno Volker 1

EUROPEAN RESEARCH PROJECT RE-VIS, DAYLIGHTING PRODUCTS WITH REDIRECTING VISUAL PROPERTIES

Advanced modelling of gratings in VirtualLab software. Site Zhang, development engineer Lignt Trans

LED Evenement 2014 Spectroscopy - Straylight. Avantes BV Apeldoorn, The Netherlands

Optimized Design of 3D Laser Triangulation Systems

Lecture 4 Recap of PHYS110-1 lecture Physical Optics - 4 lectures EM spectrum and colour Light sources Interference and diffraction Polarization

Improving Traceability of Fluorescence Calibrations to Practical Colorimetric Applications

Transcription:

ENHANCEMENT OF DIFFUSERS BRDF ACCURACY Grégory Bazalgette Courrèges-Lacoste (1), Hedser van Brug (1) and Gerard Otter (1) (1) TNO Science and Industry, Opto-Mechanical Instrumentation Space, P.O.Box 155, 2600 AD Delft, The Netherlands, Email: gregory.bazalgette@tno.nl, eddy.vanbrug@tno.nl, gerard.otter@tno.nl ABSTRACT This paper reports the result of an ESA study conducted at TNO to investigate properties of various diffusers. Diffusers are widely used in space instruments as part of the on-board absolute calibration. Knowledge of the behaviour of the diffuser is therefore most important. From measurements of launched instruments in-orbit it has been discovered that when a diffuser is used in the vacuum of space the BRDF can change with respect to the one in ambient conditions. This is called the air/vacuum effect and has been simulated in this study by measuring the BRDF in a laboratory in ambient as well as vacuum conditions. Another studied effect is related to the design parameters of the optical system and the scattering properties of the diffuser. The effect is called Spectral Features and is a noise like structure superimposed on the diffuser BRDF. Modern space spectrometers, which have high spectral resolution and/or a small field of view (high spatial resolution) are suffering from this effect. The choice of diffuser can be very critical with respect to the required absolute radiometric calibration of an instrument. Even if the Spectral Features are small it can influence the error budget of the retrieval algorithms for the level 2 products. In this presentation diffuser trade-off results are presented and the Spectral Features model applied to the optical configuration of the MERIS instrument is compared to in-flight measurements of MERIS. 1 INTRODUCTION Diffusers are widely used for the in-orbit absolute radiometric calibration of earth observation instruments. Like the earth the diffuser is illuminated by the sun giving a radiance signal, which is then measured by the instrument. With a known BRDF of the diffuser the irradiance of the sun can be determined. This irradiance is then used to determine the earth albedo from the earth radiance. Several different type of diffusers are developed and used in space. On ENVISAT the MERIS instrument used a number of Spectralon diffusers and the SCIAMACHY instrument uses two aluminium diffusers. The BRDF of these diffusers are both determined on ground under ambient conditions. Once in-orbit it was found that the BRDF was changed with respect to the on-ground calibration. This is called the air/vacuum effect. Another effect of the diffuser was discovered during the on-ground instrument calibration of the SCIAMACHY instrument. When calibrating the sun port it was found that small noise like features appeared on the measured irradiance spectrum. These features however where not noise but where introduced by the diffuser. These features are since then known as spectral features and are caused by speckle behaviour. To increase the knowledge on diffuser behaviour ESA ESTEC has conducted a study carried out by TNO to investigate the different properties of various diffusers. This paper is a summary of the findings of this study. Figure 1 Spectral Features visualization in the in-flight SCIAMACHY sun-over-diffuser measurement. Wavelength is horizontal, solar elevation angle is vertical [1] 2 DIFFUSERS Within the study two diffuser properties where studied. The air/vacuum effect was studied on a Spectralon diffuser as used in the MERIS instrument. The spectral Proceedings of the Second Working Meeting on MERIS and AATSR Calibration and Geophysical Validation (MAVT-2006), 20-24 March 2006, ESRIN, Frascati, Italy (ESA SP-615, July 2006)

features on several diffuser types of different manufactures. The choice to measure the air/vacuum effect only on one diffuser was manly practical. The measurements concerned with this effect are long and expensive. The choice for the Spectralon is made because of the knowledge of this material from the MERIS project and the fact that Spectralon is a purpose material, which means more likely to have contamination in air and therefore a bigger air/vacuum effect. The spectral features where determined for five different diffusers: 1. An Aluminium diffuser, manufactured inhouse by TNO. This type of diffuser is used in instruments like OMI, SCIAMACHY and GOME. 2. A Quasi Volume Diffuser (QVD, main material Quartz), manufactured in-house by TNO. This type of diffuser is used in instruments like OMI and GOME-2. 3. A Spectralon diffuser (main material PTFE), manufactured by Labsphere. This type of diffuser is used in the MERIS instrument. 4. A Fluorion diffuser (main material PTFE), manufactured by Altran technology. This type of diffuser has no space heritage. 5. A White tile diffuser (de-polished white ceramic), manufactured by NPL. This type of diffuser has no space heritage. 3 AIR/VACUUM EFFECT The air/vacuum of the Spectralon diffuser was determined by measuring the BRDF for different angular configuration in both air and vacuum. For this a special vacuum chamber was developed to enable radiance and irradiance measurements within vacuum. Due to the nature of the chamber radiance could only be measured at fixed angles. The sum of the angle of incidence and the observed scattering angle is always 90 degrees. A set of incidence and detection angles where measured under both ambient and vacuum conditions. The ratio between the ambient and the vacuum BRDF was used to determine any effect. In the figure below the results can be found. Note that the configuration 65 incidence/25 detection is measured twice. This configuration is measured as first and last of the series. Since the vacuum was fully established in the beginning the measurement are marked as vacuum 1 and 2. Ratio [%] 101.5% 101.0% 100.5% 100.0% 99.5% 99.0% Relatif vacuum/air effect on the BRDF for all angles TNO March 2005. BRDF of Spectralon diffuser in air and vacuum. 250 350 450 550 650 750 850 950 1050 Wavelength [nm] 65/25 vacuum1 65/25 vacuum2 Figure 2 Ratio of the BSDF measurements in vacuum and air for all angles vs wavelengths. From Fig. 2 it can be seen that there is no clear air vacuum behaviour, although the ratios are significantly different from 1. The change of BRDF seems to be rather random. When the results are plotted against the pressure a more consistent picture can be seen. In figure 3 the results for 280 nm are given showing an air vacuum effect depending on the vacuum pressure. Only the point at 55/35 is off from the general trend. This is an unknown measurement artefact. For 410 nm and 1000 nm similar results are found only with smaller ratios (and no artefact at 55/35). From the results the following was concluded: o An air vacuum effect was observed for the Spectralon diffuser. o The effect increases with decreasing wavelength, at 280 nm an effect of 1 % was observed. Ratio [%] 101.5% 101.0% 100.5% 100.0% 99.5% 99.0% 1.E-03 Relative air/vacuum effect on the BRDF versus pressure at 280 nm TNO March 2005. BRDF of Spectralon diffuser in air and vacuum. 1.E-04 Chamber Pressure [mbar] 1.E-05 65 /25 vacuum1 65 /25 vacuum2 55 /35 45 /45 30 /60 Figure 3. Ratio of the BRDF measurements in air and vacuum at 280 nm vs chamber pressure. 4 SPECTRAL FEATURES During the SCIAMACHY on-ground calibration noise like features where discovered in the spectra from the sunport. It was found that these features where 55/35 45/45 30/60 1.E-06

reproducible for the same angle of illumination. The noise like structure is of such nature that it can interfere with the data product retrieval. Hence it was necessary to find a way do minimize the effect. In the case of the SCIAMACHY instrument a second diffuser was introduced in the instrument which could minimize the features by rotating the diffuser averaging out the patterns. The origin of these features was found to be interference patterns from the diffuser. The structure of the diffuser creates speckle patterns on the detector. Speckles are known from coherent sources such as lasers. The light from the earth or the sun is not coherent, so normally no interference patterns would be expected. However due to the narrow bands of the spectrometers pixels the light on a individual pixel has a high coherence length. To explain the origin of the spectral features the following example is given. Consider a white light source with a relative flat spectrum. This spectrum is measured with a high resolution calibrated spectrometer via a diffuser. From the spectrometer a flat response would be expected, however small noise like structures are observed. On each pixel of the spectrometer a speckle pattern is imaged. This speckle pattern changes from pixel to pixel changing the total energy from pixel to pixel. This creates small fluctuations of the signal from pixel to pixel. Hence a noise like pattern. The research on the spectral features has been done by modelling and by measuring. The behaviour of the spectral features is modelled using speckle theory. The model predicts the size of the speckles and the contrast on the detector surface and by that the signal coming from this detector. The model uses the diffuser properties and the optical lay-out of the spectrometer for this calculation. To measure spectral features a special measurement strategy is used. The BRDF is measured with a narrow band spectrometer for two different positions of the diffuser. The two different positions of the diffuser was such that the BRDF can be considered the same but the speckle pattern is statistically independent. The ratio of the two BRDFs gives the spectral feature spectrum. different spectra. Taking the average over a small band of the (ratio) spectrum gives the same result as averaging over a number of independent spectra. This was proven by both the modelled results as with measured results. Tests were done for the five diffusers mentioned before. With respect to spectral features the tested diffusers can be divided into three groups: 1. Surface diffuser (aluminium diffuser), the light scatters from the surface of the diffuser. Most of the light will be scattered only once. 2. Volume diffuser (Spectralon, Fluorion, White tile), the light scatters from the bulk of the material. The light will be scattered on multiple times. 3. Quasi volume diffuser (QVD), this diffuser is a piece of quartz which is roughened at two sides, one of the sides is coated with aluminium. The bulk of the light will be scattered at least three times; at the first rough surface, at the aluminium surface and again at the rough surface. By this a volume diffuser like behaviour is established. It is expected that a large number of scattering events will minimize the spectral features. The measurements have been performed for a number of spectral bands ranging from 240 nm up to 1600 nm. As expected the aluminium diffuser has the strongest spectral features. The other diffuser give results which are more or less comparable. In Fig. 4 the SFA for the aluminium diffuser is shown. The SFA increases linear with wavelength except for the UV area. The UV part is measured with a prism as dispersing element, whereas the other parts of the spectrum are measured with a grating. The grating gives a near constant spectral resolution. With the prism the spectral resolution changes over the spectrum. The linear behaviour was already predicted by the model from the speckle theory. The theory however is true for surface diffuser. For the volume diffusers the behaviour is still near linear for a large part of the spectrum but it can be expected to behave differently when a large spectral range is considered. This has been observed for the QVD. To quantify the spectral features a spectral feature amplitude is introduced: the SFA. This SFA is a function of wavelength and is defined as the standard deviation of the spectrum value with respect to one. In principle a large number of independent spectra would be needed to determine the SFA, but it was found that a comparable results can be reached with only two

4.0% SFA on ALUMINIUM all bands large angular difference. It is obvious that the large angular difference give higher spectral features. 3.5% SFA (over 20 & 40 nm bands) 3.0% 2.5% 2.0% 1.5% 1.0% 0.5% 0.30% 0.20% 0.10% 0.00% -0.10% Speckle effect Band 4 (510nm) 3068 vs 3175 3068 vs 2444 0.0% 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Wavelength -0.20% -0.30% 1 185 369 553 737 921 Figure 4 Results of the Spectral Features measurements on an aluminium diffuser (green = winter 2004; red = summer 2005; blue = spring 2005). 0.30% 0.20% Speckle effect Band 15 (900nm) From the measurement results a comparison of the different diffusers is made with respect to there spectral feature behaviour. The results are given in the table below. As can be seen the aluminium diffuser has the highest values. The volume diffusers are more or less comparable. The QVD is comparable to the volume diffusers for 450 and 900 nm and slightly higher for 1400 nm. The design of the QVD can be changed such that it is more optimized for longer wavelength. Table 1 SFA values of the different diffusers. Diffuser type SFA value 450 nm 900 nm 1400 nm Aluminium (surface) 0.5% 1.7% 2.6% Spectralon (real 0.14% 0.7 % 1.3 % Fluorion (real 0.14% 0.7% 1.5% White tile (real 0.2% 0.6% 1.55% QVD (quasi- 0.13% 0.6% 1.7% 5 SPECTRAL FEATURES OF THE MERIS INSTRUMENT The MERIS instrument is a mid-resolution spectrometer with varying bandwidths around 10 nm. Width these kind of bandwidths no spectral features are expected as found for SCIAMACHY (resolution 0.1 nm). However for speckle not only spectral coherence but also spatial coherence is important. The narrow field of view per pixel of MERIS will introduce this coherence. 0.10% 0.00% -0.10% -0.20% -0.30% 1 185 369 553 737 921 3068 vs 3175 3068 vs 2444 Figure 5 Observations made by the MERIS instrument for two different bands. The ratio is shown for a small sun angle difference (red) and a large sun angle difference (blue). Source Steven Delwart (ESA). The model was used to see if it could reproduce the SFA of MERIS. The SFA is a standard deviation which can be compared to the peak-peak values divided by 6. The results of the SFA calculation is shown in figure 6. What is found is that the model is able to predict quantitatively the amplitude of the spectral features. The SFA values calculated with the model deviates from the MERIS observation by less than a factor 2. This means that the model can be used to give a good prediction of what order of magnitude of SFA can be expected for an optical design. Note the at the band around 760 nm the SFA curve has a peak. This peak corresponds with the smallest bandwidth of the corresponding band (i.e. 3.75 nm while the bandwidth of the other bands of MERIS is typically 10 nm). In the Fig.5 observation from the MERIS instrument are shown. The red lines show the ratio between two sun angles with a small angular difference. The blue lines show the ratio between two sun angles with a

0.18 Spectral Features Amplitude (SFA) 0.16 0.14 0.12 Standard Deviation (%) 0.1 0.08 0.06 0.04 0.02 0 300 400 500 600 700 800 900 1000 1100 Wavelength (nm) Figure 6 SFA calculation for MERIS instrument. 6 CONCLUSION The BRDF of a diffuser can be different between air and vacuum. This difference increases from 0.1 % at 1000 nm up to a few percent at 280 nm. The spectral features are caused by speckle patterns on the detector. The more coherent the light the higher the spectral features. From the tested diffuser the volume diffusers and QVD have the lowest spectral features. It has to be remarked that the performance of the QVD is dependent on the mechanical design of this diffuser. With the model it is possible to predict the spectral feature behaviour qualitatively and quantitatively. More details on this topic can be found in the final report from the study [2]. 7 REFERENCES 1. In orbit detection of spectral features in SCIAMACHY. B. Ahlers, G. Bazalgette Courrèges- Lacoste, C. Schrijvers. SPIE vol. 5570, p. 401-410, 2004. 2. Enhancement of diffusers BSDF Accuracy, ESA contract 18432/04/NL/AR, Final report. TNO-ESA- RP-DIFF-04 issue 2, 2005.