APOLLO. Multi-Functional Precision Balances. Series GX-1003A GX-3002A. Taking Weighing Precision and Protection to New Heights.

Similar documents
Series. Multi-Functional Precision Balances. Discover new ways to ensure accuracy, durability and productivity...!

APOLLO SERIES GX-A GF-A Precision Balances. Taking Weighing Precision and Protection to New Heights

Built-in Fanless Ionizer! BM-20. BM-22 (Smart range) BM-252. Series. Micro Analytical Balances BM-200 BM-300 BM g 0.

GX GF. Series. aandd. jp ISO 9000 CERTIFIED. GX-400 with optional glass breeze break. GX-600 with standard breeze break

Built-in Fanless Ionizer! BM-20. BM-22 (Smart range) BM-252. Series. Micro Analytical Balances BM-200 BM-300 BM g 0.

ANALYTICAL/SEMI-MICRO BALANCES

ANALYTICAL / SEMI-MICRO BALANCES

With a PRINT foot switch With a REZERO foot switch For incorporating into a system External IR switch

by A&D Pipette Management Solutions To protect research results from the threat of nonconformities Leak Tester: AD-1690

FX- FX i FX- FX i - W

GX/GF Series. SHS Sensor Series Precision Balances. Unrivalled in capacity and resolution: 210g / 0.001g ~ 8100g / 0.1g TYPE APPROVED PRODUCT (GX)

Oxford E Series. Instruction Manual

Jewelry Scale HT-500GD 1WMPD

SAFETY PRECAUTIONS WARNING. Repairs Do not disassemble the scale. Contact your local A&D dealer if your balance needs service or repair.

Sine-waveVibroViscometer. Series. 2ml Sample Measurement Now Possible! ISO 9000 CERTIFIED. ...Clearly a Better Value.

ANALYTICAL/SEMI-MICRO BALANCES

Analytical Balance BM-20 BM-22 BM-252 BM-200 BM-300 BM-500

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

CONTENTS. PRECAUTIONS Introduction Installation... 7

STANDARD OPERATING PROCEDURE ACB SERIES ACB-600H PRECISION BALANCE

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Compact Balances. EK-610j EK-6100j. in an Authorized A&D Dealer

MWP SERIES. High Precision

AD-4408A. Weighing Indicator for DeviceNet Interface AX-ABCC-DEVICE INSTRUCTION MANUAL 1WMPD

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

NB/NHB Precision Balance

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

Internal Calibration Counting/Percentage/Comparator Modes

OHD S.A. Equipos y Sistemas de Monitoreo Ambiental

User Manual. Models: BL 303 BL 602 BL 2002 BL 3001 BL 6001 BL 30K1

Adventurer TM Pro Analytical and Precision Balances

Pioneer. Analytical and Precision Balances

The Economical Choice of Balance for Routine Weighing Applications

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

GX-K series. GF-K series

Introduction BALANCES. Laboratory Balances. Appearance Color Physical Properties Balances. Technical Service Index

GP SERIES GP-12K/GP-20K/GP-22K/GP-30K GP-40K/GP-60K/GP-100K/GP-102K GP-30KS/GP-100KS

Pinnacle Series interfaces: RS232C, USB and LAN. Pinnacle balances are unique in offering three interfaces for external communication.

Operating instructions METTLER TOLEDO BD balances

Adventurer TM Pro Analytical and Precision Balances

A&D WEIGHING FX-i Series Toploader Balances Capacity: 120 g-3,200 g Readability: g-0.01 g

Explorer Pro. The Ohaus Explorer Pro Series, the new standard for performance and value in laboratory balances!

Ingeniously Practical. Adventurer Product Replacement Cross Reference Analytical and Precision Balances. Adventurer Pro to New Adventurer AX

Scout Resource Guide Scout Portable Balances

Analytical Balance GH-120 GH-200 GH-300 GH-202 GH-252 1WMPD C

Advanced Test Equipment Rentals ATEC (2832)

The all-new OHAUS EXPLORER. Intelligent. Intuitive. Ingeniously Practical.

INTRODUCTION INSTALLATION

Adventurer TM Pro. The OHAUS Adventurer TM Pro The Most Complete Balance in Its Class! Analytical and Precision Balances

Classic Weight Scale. Model UC-502

AUW-D/AUW/AUX/AUY Series

ELB120 ELB200 ELB300 ELB600 ELB1200 ELB2000 ELB3000 ELB12K ELB600S ELB6000S

SDG/A-056. ANALYTICAL BALANCES Weighing Technology

PLATINUM PRO1001DXP DIGITAL COUNTERTOP / PORTABLE BALANCE

Sartorius Element Series

The all-new OHAUS EXPLORER. Intelligent. Intuitive. Ingeniously Practical.

OHAUS SCOUT BALANCE SCALE

Adventurer TM Pro. The OHAUS Adventurer TM Pro The Most Complete Balance in Its Class! Analytical and Precision Balances

AD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

GF SERIES GF-200/GF-300/GF-400/GF-600/GF-800/GF-1000 GF-1200/GF-2000/GF-3000/GF-4000/GF-6100 GF-6000/GF-8000

Adventurer TM Pro Analytical and Precision Balances

SWISS MADE. Series 320 XT PREMIUM. Analytical. Precision

Pro Analytical Balances

Sartorius Element Series

Lab Catalog. Balances and Scales. Perfect Balance - Speed, Performance, Value

Pro Balances. Frameless Draughtshield With Removable Doors Provides Convenient Access

SWISS MADE EXECUTIVE PRO. Precisa 360 EP

FX-iWP SERIES. Dust and Waterproof Precision Balance INSTRUCTION MANUAL. FX-120i WP / FX-200i WP / FX-300i WP FX-1200i WP / FX-2000i WP / FX-3000i WP

The OHAUS Explorer Pro Series, the new standard for performance and value in laboratory balances!

GX-200/GX-300/GX-400 GX-600/GX-800/GX-1000 GX-2000/GX-3000/GX-4000/GX-6100 GX-6000/GX-8000

Adventurer TM Pro Analytical and Precision Balances

SWISS MADE EXECUTIVE PRO. Precisa 360 EP

by Intelligent-Lab Made in Switzerland

Discovery. Ohaus Discovery. Semi-Micro and Analytical Balances. The Professional s Choice For Analytical Applications!

B BALANCES MicroBalances/Analitycal

Production Weighing Unit

Sartorius MP8 Series Balances and Scales

SWISS MADE EXECUTIVE. Precisa 360 ES

Discovery. The Professional s Choice For Analytical Applications! Semi-Micro and Analytical Balances

The Only Scale in its Class with Touchless Sensors That Free Up Your Hands!

Adventurer Pro Analytical and Precision Balances

Counting Scales. HC-i Series

Pioneer Series. The Best Balance For Basic Weighing! Analytical and Precision Balances. Standard Features Include:

Product specifications are subject to change without any obligation on the part of the manufacture.

1WMPD B MC-1000 MC-6100

XA 4Y Analytical Balances

ANALYTICAL BALANCES AS 3Y

OHAUS Discovery. The Professional s Choice For Analytical Applications! Semi-Micro and Analytical Balances

SWISS MADE EXECUTIVE. Series 360 ES

Adam Equipment. Euro January 2003

AS X2 Analytical Balances

SWISS MADE EXECUTIVE PRO. Series 360 EP

Adventurer TM Pro Analytical and Precision Balances

Analytical Balance. HR-300i HR-202i 1WMPD C

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

AJ Series. Intelligent-Lab NTEP Centigram Balance. Made in Japan

1WMPD B MC-10K MC-30K

Eclipse EBL Series (P.N , Revision 1.00, Effective Aug 2015) Operating Manual For internal ( i ) and external ( e ) calibration models

Analytical and Precision Balances Precision Bench and Floor Scales. Weigh the Difference

Transcription:

Multi-Functional Precision Balances APOLLO GX-A /GF-A Series GF-3002A GF-1003A GX-3002A GX-1003A Taking Weighing Precision and Protection to New Heights http://www.aandd.jp

Introducing The Next Generation Of Automated Weighing Applications Today, it has become commonplace for materials to be weighed with automated devices. As precision balances are increasingly used in that way not just in production lines/systems but also in laboratories, users now face a range of unexpected problems. Fact 1: Precision balances are designed to measure static loads only. The weight sensor of a precision balance, regardless of its manufacturer, breaks in a short period if it is continuously affected by loads with acceleration (i.e. impact shocks). This typically occurs in factories where materials are placed roughly by machines or thrown by operators onto balances. In addition, impact shocks can easily shift values and cause errors. The difficulty is that even if you know the above, you may not know what degree of impact shock is safe or unsafe for the balance to take necessary preventive measures such as refining the automatic loading mechanism. Solution: Impact Shock Detection (ISD) Patented The GX-A/GF-A series visualizes the magnitudes of impact shocks that the weight sensor receives at four levels. It beeps once at Level 3 and twice at Level 4 (both of which should be avoided). No impact shock Level 1 Level 2 Level 3 Level 4 Cushioning under the weighing pan The two leaf springs that support the weighing pan of the GX-A/GF-A series also mitigate impact shocks significantly. Overload protection The weight sensor is well protected against vertical and transverse static overloading. It won't break due to malfunction of the weighing system's actuator and the resulting excess load. A&D's testing demonstrated that even a human did no damage to the balance by stepping on it. Leaf springs Fact 2: Precision balances are intended to be used in a stable environment. The performance (repeatability as well as display stability) of a precision balance is worsened by external disturbances such as drafts and vibrations, which is often the case in the field. Therefore, it is strongly recommended to evaluate whether the set-up conditions are appropriate. Checking repeatability, however, is cumbersome, especially once the balance is embedded in a system. Further, it is not uncommon that users don't have an adequate test weight. 1

Solution: Auto Precision Assessment (APA) The GX-A/GF-A series is designed with A&D's latest technology, Electronically Controlled Load (ECL). This technology artificially generates a minute load (0.3 to 3% of the weighing capacity) by altering the equilibrium state of the weight sensor. After making a quick diagnosis of whether there is a critical failure, the balance indicates the standard deviation (i.e. repeatability) calculated from 10 repeated measurement with ECL on the spot. The entire process takes only 1.5 minutes. Patented Standard deviation calculated using ECL Adjustable response characteristics You can trade weighing speed for higher display stability 1 or vice versa by selecting one of three preset response characteristics (FAST, MID or SLOW). 1 This is not to improve repeatability. Fact 3: Internal clocks of precision balances are never in complete sync with those of external devices. This clock time disparity manifests as a problem most noticeably when you measure and record flow rates of pumps, feeders and other devices at short intervals 2 with a balance connected to a PC that performs the calculation. The timing at which the balance receives the command from the PC to send the weight value and its display refresh cycle gradually go out of alignment. In consequence, the PC intermittently produces irregular values (spikes when graphed) even if the actual flow rate is constant. 2 Flow rate is determined from the weight variation that occurs during a given interval. 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec Balance PC 0 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 6 1 sec 2 sec 3 sec 4 sec 5 sec 6 sec Time disparity of two different internal clocks (when the balance display refresh rate is 5 times/sec, the interval is 1 sec, and the balance's internal clock goes slightly ahead of the PC's) Solution: Flow Rate Display (FRD) The GX-A/GF-A series can calculate and display/output the mass flow rate (the unit of measure can be selected from g/s, g/m or g/h), or the volume flow rate (ml/s, ml/m or ml/h) by entering the density of the material. Up to 10 densities can be saved to the device. Both the display refresh rate and interval (set between 1 second and 1 hour) are regulated by the same internal clock of the balance, making measurements free from the aforementioned problem. Patent pending 0.45 g/s Conventional method FRD 0.4 g/s 0.35 g/s Flow rate measurement using FRD as opposed to the conventional method 2

Flow rate comparator The indication allows you to monitor whether the flow rate is kept within the designated limits. Tare memory The tare value can be saved in non-volatile memory so that the remaining amount of the material in the container can be displayed again 3, even if power is disrupted for any reason during loss-in-weight measurement. 3 When this function is activated, the power-on re-zero/tare is turned off. On top of the above, the GX-A/GF-A series has many advanced and practical features and is perfect for manual weighing applications. RS-232C and USB interfaces as standard For the USB interface, you can toggle between the Quick USB mode (plug-and-play with weighing data output to a PC only) and the Virtual COM mode (for bi-directional communication 4 ) with internal settings. A USB cable is provided as standard. 4 A special driver downloaded from the A&D website needs to be installed on the PC (except those with Windows 10). Security slot An off-the-shelf (such as Kensington) anti-theft lock can be used to prevent the balance from being lost. Reverse backlit LCD display The contrast of black and white provides excellent visibility even in poorly-lit areas and also prevents eye fatigue. Large, easy-to-see spirit level with LED illumination The illumination blinks for 5 seconds after the display is turned on to indicate that the balance level needs to be checked. Leveling feet with thumbwheel The leveling feet can be adjusted up or down smoothly using large thumbwheels. 3

Data management, documentation and compliance Minimum weight calculation based on the APA From the standard deviation obtained using ECL described earlier, the GX-A/GF-A series also calculates and indicates the minimum weight at the installation location 5 in accordance with the United States Pharmacopeia (USP) standard. 5 The effects of the ambient environmental conditions on repeatability is taken into account, unlike the values shown in catalogs as "ideal" or "typical". Minimum weight alert To ensure that the measured sample quantity meets the minimum weight requirement, the GX-A/GF-A series can display an alert until the sample quantity reaches the value entered as the minimum weight. 6 6 It is also possible to directly use the minimum weight determined by ECL. Blinking minimum weight alert User access control (UAC) and key lock for data integrity Use of the balance can be password-protected for authorized individuals (up to 11 including one administrator) the administrator can perform all operations including calibration while other users can make measurements only. Moreover, upon receiving a command to disable its keys, the balance becomes operable only by sending commands from an external device such as a PC. Automatic self calibration (for the GX-A series) The GX-A series can be set to calibrate itself automatically using its internal weight either (1) in response to change in ambient temperature to prevent error due to sensitivity drift, (2) at a set interval time, or (3) at predetermined (up to three) times of the day. Internal calibration can also be performed any time with one key press. GLP/GMP/GCP/ISO compliant output For documentation requirements, the GX-A/GF-A series can output its manufacturer, model, serial number, ID number, date + time, space for signature for calibration report, calibration test report, and title & end blocks for a series of weighing results. Universal Flexi Coms (UFC) UFC lets you edit serial data output/printout format. With this function, label printing is also made possible by connecting the balance to a commercially-available printer 7, and enabling arbitrary character strings output. 7 Printers that can program printing content from the strings sent through RS-232C. Please note that a cross cable is required depending on the printer. Gross/Net/Tare output On receiving a command or with key operation, the GX-A/GF-A series outputs the gross, net, and tare values to an external device such as a printer, PC or PLC. Statistical calculation function (SCF) The GX-A/GF-A series can display and output statistical calculation data including number of data, sum, maximum, minimum, range (maximum-minimum), average, standard deviation, and coefficient of variation to facilitate the analysis of measurements. 4

Options GXA-03 GXA-04 GXA-06 FXi-08 GXA-09 GXA-10 GXA-12 GXA-13 GXA-17 GXA-23-PRINT GXA-23-REZERO GXA-23-PLUG GXA-24 GXA-25 GXA-26 2nd RS-232C interface 8 Comparator relay output/buzzer/external key input interface 8 Enables signaling check weighing results (5 steps) by buzzer and/or external comparator (traffic) lights. It also has two jacks for separately-sold foot switches. Analog output interface 8 0-1 V, or 0.2-1 V for conversion to 4-20 ma. Ethernet interface 8 Built-in rechargeable battery (factory-installed/dealer option) 8 10 hours of charging for 14 hours of operation (the remaining battery level will be indicated on the display). The balance can be used while recharging the battery. Large glass breeze break Animal weighing pan (for models of 320 g capacity or higher) Use together with the animal weighing (average & hold) mode. Density determination kit (for the 1 mg models only) Makes weighing the sample in air and in water quicker, easier and more precise. The GX-A/GF-A series can then perform a density calculation automatically. Large glass breeze break with built-in fanless ionizer (static eliminator) The fanless ionizer can neutralize even extremely fine powders without disturbance. External key input interface with the AX-SW137-PRINT foot switch 8 External key input interface with the AX-SW137-REZERO foot switch 8 External key input interface with the AX-T-314A-S plug 8 USB host interface (factory-installed/dealer option) 8 Accepts an off-the-shelf USB flash drive to save weighing results in CSV format. External fanless ionizer (static eliminator) 8 Power is supplied from the balance. Activated for a set duration with an IR sensor. External IR switch 8 For touchless operation of print or re-zero (tare). GXA-10 Large glass breeze break The glass panes disappear into the back when opening the door, requiring no extra space at the rear of the balance. Easily attachable/detachable. 8 Only one of GXA-03, GXA-04, GXA-06, FXi-08, GXA-09, GXA-23-PRINT/REZERO/PLUG, GXA-24, GXA-25 or GXA-26 can be installed. Accessories AD-1641 AD-1682 AD-1683 AD-1684A AD-1687 AD-1688 AD-1689 AD-1691 AD-8127 AD-8526 AD-8920A AD-8922A AX-GXA-31 AX-SW137-PRINT AX-SW137-REZERO AX-USB-9P Air flow logger Rechargeable battery unit Static eliminator 9 Electrostatic field meter Weighing environment logger Weighing data logger Tweezers for calibration weight Weighing environment analyzer Compact printer Serial/Ethernet converter Remote display Remote controller Main unit cover (5 pcs) Foot switch for print Foot switch for re-zero Serial/USB converter and cable set 9 Power needs to be supplied from an AC adapter. AX-SW137-PRINT AD-8127 AX-SW137-REZERO 5

AD-8529PC/PR-W Bluetooth converters Enable wireless communication between a balance/scale and a PC/printer using low-energy Bluetooth 10 (line-of-sight distance approx. 10 m when there is no radio wave interference). AD-8529PC-W for communication with a PC USB connector Approx. 10 m D-Sub connector AD-8529PR-W for communication with a printer 10 Please contact your local A&D representative to find out whether the AD-8529PC/PR-W is certified for compliance with Bluetooth communication laws in your country. D-Sub connector Dimensions (mm/inches) 317/12.48 40/1.58 GX-203A / GX-303A / GX-403A / GX-603A / GX-1003A / GX-1603A GF-123A / GF-203A / GF-303A / GF-403A / GF-603A / GF-1003A / GF-1603A 212/8.35 210/8.27 77/3.03 160/6.3 144/5.67 124/4.88 74.5/2.93 190/7.48 160/6.3 144/5.67 124/4.88 128/5.04 128/5.04 93/3.66 90/3.54 175/6.7 181/7.13 94.7/3.73 217/8.54 224/8.82 GX-2002A / GX-3002A / GX-4002A / GX-6002A / GX-10002A 317/12.48 40/1.58 GF-1202A / GF-2002A / GF-3002A / GF-4002A / GF-6002A / GF-10002A 212/8.35 210/8.27 165/6.5 93/3.66 190/7.48 165/6.5 181/7.13 94.7/3.73 217/8.54 224/8.82 6

Specifications Models Weighing capacity Minimum weighing value Repeatability (standard deviation) Linearity Stabilization time (when set to FAST under a good environment) Sensitivity drift Accuracy immediately after internal calibration (for the GX-A series) i Operating environment Display refresh rate Units of measure ii Counting mode Percent mode Minimum unit mass Number of samples Minimum 100% reference mass Minimum 100% display Communication interface Weighing pan size External dimensions Net weight Power supply / consumption GF-123A GX-203A GF-203A GX-303A GF-303A GX-403A GF-403A GX-603A GF-603A GX-1003A GF-1003A GX-1603A GF-1603A 122 g 220 g 320 g 420 g 0.001 g 620 g 1100 g 1620 g 0.002 g (for 1600 g) 0.001 g 0.001 g (for 1000 g) ±0.002 g ±0.003 g Approx. 1.5 sec Approx. 1 sec (approx. 0.8 sec for 5 g) (approx. 0.8 sec for 5 g) ±2 ppm/ C (10 to 30 C/50 to 86 F, when automatic self-calibration is OFF) ±0.010 g ±0.010 g (for 1000 g) 5 to 40 C (41 to 104 F), 85%RH or less (no condensation) 5 times/sec, 10 times/sec or 20 times/sec g (gram), oz (ounce), lb (pound), lb-oz (pound-ounce), ozt (troy ounce), ct (metric carat), mom (momme), dwt (pennyweight), gr (grain), pcs (counting mode), % (percent mode), SG (specific gravity), and a user-programmable unit. 0.001 g 5, 10, 25, 50 or 100 pieces 0.100 g 0.01%, 0.1% or 1% (depends on the reference mass stored) RS-232C and USB 128 128 mm 212(W) 317(D) 93(H) mm Approx. 5 kg AC adapter / approx. 30 VA Models Weighing capacity Minimum weighing value Repeatability (standard deviation) Linearity Stabilization time (when set to FAST under a good environment) GF-1202A GX-2002A GF-2002A GX-3002A GX-4002A GX-6002A GF-3002A GF-4002A GF-6002A GX-10002A GF-10002A 1220 g 2200 g 3200 g 4200 g 6200 g 10200 g 0.01 g 0.02 g (for 10000 g) 0.01 g 0.01 g (for 5000 g) ±0.02 g ±0.03 g Approx. 1.5 sec Approx. 1 sec (approx. 0.8 sec for 50 g) (approx. 0.8 sec for 50 g) GX-6001A GF-6001A GX-10001A GF-10001A 6200 g 10200 g 0.1 g Sensitivity drift ±2 ppm/ C (10 to 30 C/50 to 86 F, when automatic self-calibration is OFF) Accuracy immediately after internal calibration (for the GX-A series) i ±0.10 g ±0.15 g ±0.15 g (for 5000 g) ±0.5 g (for 5000 g) Operating environment 5 to 40 C (41 to 104 F), 85%RH or less (no condensation) Display refresh rate 5 times/sec, 10 times/sec or 20 times/sec Units of measure ii g (gram), oz (ounce), lb (pound), lb-oz (pound-ounce), ozt (troy ounce), ct (metric carat), mom (momme), dwt (pennyweight), gr (grain), pcs (counting mode), % (percent mode), SG (specific gravity), and a user-programmable unit. Counting mode Minimum unit mass 0.01 g 0.1 g Number of samples 5, 10, 25, 50 or 100 pieces Percent mode Minimum 100% reference mass 1.00 g 10.0 g Minimum 100% display 0.01%, 0.1% or 1% (depends on the reference mass stored) Communication interface RS-232C and USB Weighing pan size 165 165 mm External dimensions 212(W) 317(D) 93(H) mm Net weight Approx. 5 kg Power supply / consumption AC adapter / approx. 30 VA i Under stable environment (no rapid temperature/humidity change, vibration, draft, magnetism, static, etc). The mass of the internal weight may vary with age. ii One additional unit from tael (Singapore/HK jewelry/taiwan/china), tola or Newton can be added upon request. 0.1 g ±0.1 g Approx. 1 sec (approx. 0.8 sec for 500 g) GX-A GF-A Optional A&D Company, Ltd. 3-23-14 Higashi-Ikebukuro, Toshima-Ku, Tokyo, 170-0013, Japan Tel: +81 3-5391-6132 Fax: +81 3-5391-1566 http://www.aandd.jp A&D Engineering, Inc. 1756 Automation Parkway, San Jose, CA 95131, U.S.A. Tel: +1 408-263-5333 Fax: +1 408-263-0119 A&D Australasia Pty Ltd. 32 Dew Street, Thebarton, South Australia 5031, Australia Tel: +61 8-8301-8100 Fax: +61 8-8352-7409 A&D Instruments Ltd. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxfordshire, OX14 1DY, United Kingdom Tel: +44 1235-550420 Fax: +44 1235-550485 <German Sales Office> Hamburger Straße 30, D-22926, Ahrensburg, Germany Tel: +49 4102-459230 Fax: +49 4102-459231 A&D Korea Ltd. 8F Manhattan Bldg., 33, Gukjegeumyung-ro 6-gil, Yeongdeungpo-gu, Seoul, 07331, Korea Tel: +82 2-780-4101 Fax: +82 2-782-4280 A&D Rus Co., Ltd. Vereyskaya Str. 17, 121357, Moscow, Russia Tel: +7 495-937-33-44 Fax: +7 495-937-55-66 A&D Instruments India (P) Ltd. 509 Udyog Vihar Phase V Gurgaon-122 016, Haryana, India Tel: +91 (124) 471-5555 Fax: +91 (124) 471-5599 GXGF-A-ADCC-03-PR3-18901GP