Installation Instructions Revision 1.0 June 2009 Page 1 of 6

Similar documents
WEB Revision T, May 2016 CommScope Actuators

Revision B, May Updating Firmware of E-ATM300 Actuators Using the. EFCT Software Application with ATC200-LITE-USB Control System

Triple Band Twin TMA (AWS/PCS/WCS) with AWS-3 and 700/850 Bypass

Revision H, May ATC /2000 Control System. Computer Interface Setup

INSTALL INSTRUCTIONS RSXMR-9886-P-48

Installing and Cabling Flexi Zone Micro High Power 2x20 W BTS DN Issue 02 Approval Date yyyy-mm-dd

/ Outdoor Diplexer DPO-6789B-X-XX

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

ATC Teletilt Remote Control Variable Electrical Downtilt System

R2 Extender. Quick Installation Guide

R2 BaseStation. Quick Installation Guide

R1 Extender. Quick Installation Guide

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

Pre-Testing and Configuring of. RET Antenna Systems. Prior to Installation. Overview

Quick Installation Guide

IEEE b/g/n Wireless Outdoor CPE. Quick Installation Guide

12-Port Antenna MHz mm

/ / MHz

RE.41.LGTW - L-gateway - Modular IoT Base Station Quick Installation Guide

Replacing the Power Supply

SM Sygnus Hybrid Quick Installation Guide Version

MBE Mounts and Adapters

Quick Installation Guide

ZAC / ZAC ZAC Wireless Access Point

/ MHz

/ / MHz

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

DC Outdoor Power Supply/Chargers

Speed Dome Installation Manual

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

/ / MHz

HDR TM K HOIST DRUM ROTATION INDICATOR KIT

Site Control Unit SCU-AISG2-P DATA SHEET. Technical Description

AW58100HTP-PAIR USER S MANUAL

ZAC / ZAC ZAC Wireless Access Point

Remote Electrical Downtilt System Handbook

Bias-T for Cellular & PCS Networks

ANTENNAS FOR CELLULAR NETWORKS

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

1 Installing the VG4-A-ARMPLATE

Cambium PTP 650 LPU and Grounding Kit Installation Guide

Fibre Modem - Single-mode

InView Marquee Message Display

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

/ MHz

Cisco Aironet 1300 Series Lightweight Outdoor Access Point Mounting Instructions

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

LARGE S URGE-PROTECTOR S HELTER

AW58300HTA AW58300HTS USER S MANUAL

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Installing the DX LCD Display

ACCREDITED SOLUTION. EXPLORER CPN Enclosure

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

Part Name/Description Part Number Quantity

CRITICAL COMMUNICATION NETWORKS. Reliable Performance From The Tower To The Core

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

PowerFlex 400 Frame G and H Replacement Procedure for Gate Power Board

G12/G12x USER S MANUAL

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

Junos WebApp Secure 5.0 Hardware Guide

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

AlphaGateway SMG-01PE Quick Start Guide

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

SPECIAL SPECIFICATION 8143 Wireless Ethernet Radio System

OTPC 150/225/260 Amp Transfer Switch

Revision History E F G H J K Revision Description: K > Allegion Rebranding.

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

FortiCam SD20 Mounting Guide

NetCommWireless. Quick Start Guide NTC-30 Series - Outdoor WiFi Router

Full HD Speed Dome IP Camera

Installation Note. 8719D, 8720D, and 8722D Network Analyzer Option 1D5 High Stability Frequency Reference Upgrade Kit

MODEL Weatherproofing Instructions

MASTERLINE Ultimate Hybrid High Voltage 4/12 (MLUH HV 4/12) blunt cut at BTS side

Series 3700 Screw Terminal Assemblies Installation Instructions

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

INSTRUCTION BULLETIN

Canopy Surge Suppressor

COMPLETE S YSTEM SHELTER

Installing the Cisco VG224 Voice Gateway

INSTALLATION INSTRUCTIONS

RUGGEDCOM WiN7000. FCC Statement And Cautions. Introduction. Site and Installation Requirements. Installation Procedures. Setup.

Cisco Aironet 1500 Series Access Point Large Pole Mounting Kit Instructions

HX WCS Indoor DAS Remote Unit Quick Installation Sheet

INSTALLATION GUIDE PTP 670. System Release 02-00

4888 and 4988 Outdoor Protected Entrance Terminals

Integrated Battery Control System LBCS Step-by-Step Setup Guide

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

XBR V4 INSTALLATION AND USER GUIDE

INSTALLATION INSTRUCTIONS

Installation and Configuration Quick Guide R2000. Industrial Dual SIM Cellular VPN Router (2 Eth + 2 SIM) Package Contents

IntelliLED TM. Controls: User Guide. Picture for DALI only. Wireless adds external antenna. NOTE: These parts are NOT user serviceable

Ruckus Wireless ZoneFlex 7762 Dual Band n Outdoor Access Point. Installation Guide

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Chameleon Stand-alone

Installation & Operation Instructions

USERS MANUAL Section (C)(3)

Transcription:

Bulletin II 103282-EN Installation Instructions Revision 1.0 June 2009 Page 1 of 6 OneBase Dual Band and Twin TMA ETT19V2S12UB/ETW200VS12UB/ETW190VS12UB INTRODUCTION Andrew OneBase Tower Mounted Amplifiers (TMA) enhance the uplink/reverse RF performance by improving the sensitivity of the base station receiver, extending the talk back range for subscriber transmitters operating in the base station receive band. TMAs are installed near the receive antenna to eliminate signal degradation resulting from feeder loss. There are two ports in the TMA. Dual band TMA supports (PCS/AWS) shown in Figure 1. Twin TMA supports same band (PCS or AWS) shown in Figure 2. In addition, it supports AISG and daisy-chained AISG RET. Some benefits of using TMAs include: increased coverage area improved signal quality fewer dropped calls in fringe areas and inside buildings extended battery life in handheld terminals RELATED EQUIPMENT To complete your TMA system, you may need the following additional equipment: 1. Bias Tee to inject DC supply power on the RF feeder. For AISG controller, it might require a smart bias-tee or AISG compatible bias-tee. 2. Power Distribution Unit to condition and monitor the DC supply power and or AISG controller either from third-party or from OEM vendor which provides AISG functionality and supplies DC. Contact your Sales Representative for recommendations on applicable system components. PRODUCT DESCRIPTION Refer to Figure 3 for block diagrams of the TMAs. The fully integrated, weatherproof TMA contains filters, AISG, low noise amplifier(s) (LNA), CPU and a DC bias tee. It amplifies each port separately and passes RET signals through the AISG port. DC supply power to the LNA is provided through the RF feeder from the base station and is recovered in the bias tee. The LNA includes a bypass switch to ensure continued operation with reduced sensitivity in case of DC power removal. TMA also support DC switching which allows uninterrupted DC supply in case of DC supply failure on one port. AISG remote firmware upgrade is supported. TMA can operate in either current mode (no AISG) or in AISG mode. Both modes support VSWR and TMA alarms reporting. Lightning protection for the antenna port consists of a low frequency path to ground while at the BTS port, a Surge Suppression Circuit is integrated with the bias tee.

Bulletin II 103282-EN Revision 1.0 June 2009 Page 2 of 6 Antennas Daisy-chained actuators Twin TMA Exact Label found next to the connectors AWS BTS PCS BTS Figure 2 - Twin TMA Connections Figure 1 Dual Band TMA Connections AWS ANT OR ANT 0 PCS ANT OR ANT 1 TX Filter TX Filter LNA LNA By-Pass Switch By-pass Switch CPU Bias tee AISG Bias tee AWS BTS OR BTS 0 AISG PCS BTS OR BTS 1 Figure 3 TMA Block Diagram

Bulletin II 103282-EN Revision 1.0 June 2009 Page 3 of 6 BEFORE INSTALLATION 1. The TMA is designed to withstand the rigors of operation in an outdoor environment. While handling the TMA, take necessary steps to protect it from dents and scrapes that may compromise its durability. Keep dirt and moisture away from the connector interfaces. 2. Ensure that transmit power in each band is within the average and peak power ratings for the TMA. 3. Determine the installation location. Optimum sensitivity improvement is obtained when the TMA is installed as close as possible to the receive antenna. 4. Pole mounting hardware is supplied with the TMA. The unit can be mounted to a pole or tower member with a diameter up to 5.51 inches (140 mm). Mounting to a wall is also possible. Appropriate fasteners for the intended surface must be obtained separately. 5. Obtain appropriate jumper cables. To protect against connector damage, the TMA should be connected to the antenna and to the feeder with jumper cables (½ inch recommended). 6. If AISG port is used, select the correct cable length. 7. Choose grounding method. A separate ground connection is advised. Andrew recommends 1m Ground Cable, part no. GND-1M or other 6-8 AWG copper wire. 8. Plan the installation. Inspect the equipment. Review the instructions. TMA has label that indicates which the side goes to the BTS and to the antenna. Ensure that needed tools and supplies are available, including cable ties, grounding hardware, and weather-sealing materials.

Bulletin II 103282-EN Revision 1.0 June 2009 Page 4 of 6 Figure 4 Assembling Pole Mount Hardware Step 1.2 Figure 7 Assembling Pole Mount Hardware - Step 1.5 Figure 5 Assembling Pole Mount Hardware - Step 1.3 Figure 8 TMA with Pole Mount Hardware Figure 9 AISG Pins Figure 6 Assembling Pole Mount hardware step 1.4

MOUNTING TO A POLE OR BEAM 1. TMA comes with pole mounting kit and mounting instructions. Assembling the pole mounting hardware as follows: 1.1. Insert the band through the holes in the TMA brackets. 1.2. Orient the TMA in the selected location with the BTS port pointing down marked on the TMA with BTS and Antenna port pointing up marked with ANT, or as required. 1.3. Insert one terminal of the back into the lower slot of the buckle shown in Figure 4. 1.4. Insert the other terminal of the back into the upper slop of the buckle as shown in Figure 5. 1.5. Rotate the screw toward the band while pressing as shown in Figure 6. 1.6. Tighten the screw along the band up to the required strength (max 5 Nm) by means of a screwdriver as shown in Figure 7. 1.7. Repeat on the other side of the TMA. Figure 8 shows the assembled mounting hardware with TMA. 2. Attach a ground cable to the TMA using the preinstalled hex bolt and washers. Route the ground cable to the ground bar on the tower structure and attach securely with suitable fastener. 3. Route cables as follows: 3.1. Route a jumper cable from the AWS antenna port to the TMA port marked ANT AWS for dual band TMA. For twin TMAs, it is marked as ANT 0 or ANT 1. 3.2. Route a second jumper cable from the PCS antenna port to the TMA port marked ANT PCS for dual band TMA. For twin TMAs, it is marked as ANT 0 or ANT 1. 3.3. Route a third jumper cable from the TMA port marked AWS BTS for dual-band TMA to the tower feeder for the AWS Node B/BTS. For twin TMAs, it is marked as BTS 0 or BTS 1. 3.4. Route a fourth jumper cable from the TMA port marked PCS BTS for dual band TMA to the tower feeder for the PCS Node B/BTS. For twin TMAs, it is marked as BTS 0 or BTS 1. Be sure to provide adequate curve or loop to relieve undue strain on connectors at either end. 4. Tighten RF connections to 18 ft-lbs (25 Nm) torque. Bulletin II 103282-EN Revision 1.0 June 2009 Page 5 of 6 5. Weatherproof the cable connections per standard practices if required by local conditions. Provided materials, if any, can be applied according to the instructions on the package. 6. If AISG port is used to connect to the RET actuators, make sure that the AISG cable (connecting TMA to the actuator) is hand tightened. Over tightening the cable connection on TMA side or Actuator side can damage the AISG pins. AISG cable has a male and a female 8-in circular connector shown in Figure 9. These AISG connectors have locking screw-rings and are keyed to provide a matching fit with the ports on the actuator and TMA. No weatherproofing is required. 7. If AISG is not used, please ensure that the AISG cap provided with the TMA is attached and hand tightened. 8. Apply cable ties or straps (not supplied) to secure the cables to the tower structure. MOUNTING TO A WALL The TMA can be mounted to a suitable flat surface. 1. Mount the TMA to the wall using four 5/16 or 8 mm bolts (not supplied) through the holes in the TMA brackets. 2. Connect RF, AISG and ground cables, weatherproof and secure with straps as outlined above.

Bulletin II 103282-EN Revision 1.0 June 2009 Page 6 of 6 NOTICE The installation, maintenance, or removal of antenna systems requires qualified, experienced personnel. Andrew installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel to verify proper installation, maintenance, and condition of equipment. Andrew disclaims any liability or responsibility for the results of improper or unsafe installation practices. Do not install near power lines. Power lines, telephone lines, and guy wires look the same. Assume any wire or line can electrocute you. Do not install on a wet or windy day or when lightning or thunder is in the area. Do not use metal ladder. Wear shoes with rubber soles and heels. Wear protective clothing including a longsleeved shirt and rubber gloves.