Quick Reference Guide

Similar documents
Quick Reference Guide

Ilumipanel 180 IP Optic RGB. Quick Reference Guide

Quick Reference Guide

Quick Reference Guide

Quick Reference Guide

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer.

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer.

4X10W RGBW 4 IN 1 Led Wireless Battery Zoom Light

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer.

SPECIFICATION. Ilumipod 48 IP Optic 15 RGBW gray housing Item Number:

i.shine 1136 RGBW Color Stainer CN USER MANUAL

i.shine 3148 RGBW Color Stainer XP USER MANUAL

CW-WW LEDWash USER MANUAL

dynamic white par manual

Edition Notes. Edition Notes. Trademarks CHAUVET is a registered trademark of CHAUVET & Sons Inc. (d/b/a CHAUVET or

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing

Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer. CHAUVET Publications Hot Line

Edition Notes. Edition Notes. Trademarks CHAUVET is a registered trademark of CHAUVET & Sons Inc. (d/b/a CHAUVET or

LED Pixel Bar. Model No. PIXBAR12x3, PIXBAR12x8,PIXBAR12x12 USER MANUAL. For safety, please read this user manual carefully before initial use.

Springtree Spatial Wash COB RGBW

Edition Notes. Edition Notes

Quick Reference Guide

Edition Notes. Edition Notes. Trademarks. Copyright Notice. Manual Usage. Document Printing. Intended Audience. Disclaimer.

Quick Reference Guide

Solutions 2011 Vol. 1 ILUMINARC. Sense. Sight. Soul.

K9 Lights USER MANUAL

Quick Reference Guide

Stage Flood QCL 24x10W LED floodlight. user manual

Vortex. User Manual. Order code: EQLED073

Ostar Eye K18. Beam and Kaleido Effects. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

A double yoke enables the fixture to be operated in several positions.

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

KasBar COB Tri 5. 5x15w 3in1 COB LEDs (RGB) USER MANUAL

Endura 1Q120 RGBW COB Exterior Fixture

StagePar COB TRI 4 CKU

IR Controller. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

High Power Outdoor Bar Washer, 24 RGB 3Watt LED Fixture User Manual

TB-1230 QW. User Manual Please read the instruc on carefully before use

RGB Power Batten. User Manual. Order code: EQLED032

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

Blitzer RGB Strobe. User Manual. Order code: EQLED365

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

MATRIX 25E. Matrix Beam Wash, ArtNet, RDM. User manual. Please read the instructions carefully before use

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

RGBW 3x4 Brick & 10x4 Batten USER MANUAL

High Power Outdoor Bar Washer, 12 RGB 3Watt LED Fixture User Manual

VBAR 270. User Manual. Version 1.2

MH-B373. P l e a s e R e a d O v e r T h i s M a n u a l B e f o r e O p e r a t i n g T h e L i g h t F i x t u r e

Bi-color Die-casting Aluminum LED Profile Spotlight. CE RoHS. MODE NO. Spectra leko led 300

Intense 9HEX10 LED Slim Par

Fresco 24 RGBW. Exterior Fixture User Manual. Order code: LEDJ267

COB100/200W 2in1/3in1 led Par Light

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

ARC PAR 715 RGBW CODE 1058

Stage Flood QCL 24x10W, Stage Flood Inst QCL 24x10W LED floodlight. user manual

LED Slimline PAR RGBW 7x8W

DIRECT POWER LIGHTING MANUAL

EC12-10V 12 in. Extension Cord EC24-10V 24 in. Extension Cord EC60-10V 60 in. Extension Cord

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

MODA COVE INTERIOR RGB PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

Springtree Spatial Wash COB WW

PROFESSIONAL SHOW LIGHT

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

w w w. p r o l i g h t. c o. u k STAGE PAR 64

LED SUPER PAR USER MANUAL

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Edition Notes. Document Revision

LED ZOOMING MOVING HEAD MH-91. Please Read Over This Manual Before Operating The Light Fixture

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

Item ref: UK User Manual. MW-7 4-in-1 LED Mini Moving Head

CP476 English manual. Wireless RGBW controller

LED PAR with 6-in-1 RGBAW+UV LEDs projects perfectly mixed and finely tunable colors

>daisy. Daisy-ON OUTDOOR / UNDERWATER USE. Daisy-IN INDOOR USE. Daisy-OUT INDOOR / OUTDOOR USE

LED Stage Par Light DMX wireless&battery 10-watt x 4 LEDs (R/G/B/A/W 5IN1) User s Manual

SPOT MOVING HEAD M1S150W USER MANUAL. For safety, please read this user manual carefully before initial use.

Blitzer Strobe. User Manual. Order code: EQLED366

Vector Beam White. User Manual. Order code: LEDJ265

Slimline CW & WW Series

MODA COVE INTERIOR RGBW PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

Table of Contents. 1. Before You Begin...1

Compact UV wash featuring ultra wide coverage and high-output COB LED

Robot Light V2. User Manual

MODA COVE EXTERIOR RGBW PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

36LEDs Par Light. User Manual

LED PAR with 3-in-1 Amber - Warm white - Cool white LEDs projects perfectly mixed and finely tunable white light

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

FOS PAR Innovative 1

CLS Atmosphere LED-panel

TourPro RGBAW Stagebar USER MANUAL

LED ZOOMING MOVING HEAD MH-91. Please Read Over This Manual Before Operating The Light Fixture

Gobo Projector XP 80W

Fusion Saber. User Manual. Order code: EQLED070

Slimline 12Q5 Series

User Instructions. American DJ Charter Street Los Angeles Ca

MODA COVE INTERIOR DYNAMIC WARM PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

ETC Installation Guide

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

>dawn FC OUTDOOR USE

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

MODA COVE INTERIOR DYNAMIC WHITE PRODUCT GUIDE. Client: Project Name: MODA Contact: Quantity: Type: PO#: Notes:

Transcription:

Ilumipod 42 IP Series Quick Reference Guide

About this Guide Disclaimer The Ilumipod 42 IP Series Quick Reference Guide (QRG) only contains the product s connection and mounting information as well as the menu options and the DMX values. This QRG does not replace the product s user manual. You must download the corresponding user manual from the ILUMINARC Web site (www.iluminarc.com) to learn about the disclaimers, safety notes, programming modes, and technical information. Safety Notes DO NOT open this fixture unless instructed. It contains no user serviceable parts. DO NOT look at the light source when this fixture is on. DO NOT touch the fixture when it is operating because it may be hot. DO NOT leave any flammable material within 50 cm from this fixture while operating or connected to the power outlet to minimize the risk of fire. DO NOT mount this fixture overhead without using a safety cable. DO NOT submerge this product (IP66). Regular outdoor operation is fine. DO NOT operate this fixture if you see damage on the housing, lenses, or cables; have the damaged parts replaced by an authorized technician at once. DO NOT connect this fixture to a dimmer or rheostat. ONLY connect this fixture to a grounded and protected circuit. What is Included One Ilumipod 42 IP fixture (either RGBW or VW) Warranty Card Quick Reference Guide Ordering Info Model Housing Color Yoke Item Number Optic 15 RGBW White Double 11042001 Optic 30 RGBW White Double 11042002 Optic 15 RGBW Gray Single 11042003 Optic 30 RGBW Gray Single 11042004 Optic 15 VW White Double 11042005 Optic 30 VW White Double 11042006 Optic 15 VW Gray Single 11042007 Optic 30 VW Gray Single 11042008 2

Common Features RGBW Features White or gray cast aluminum housing Single or double bracket yoke IP66 ingress protection rating IP66 stainless steel gland nuts for cable entry Bare ended IP66 power input cable Bare ended IP66 data input/output cable Impact resistant glass lens cover High-power, 1 W (350 ma) LEDs 3, 4, 5, 6, or 11 channel DMX LED wash light (with ID addressing) Operating modes: 3-channel: RGB control 3-channel: HSV control 4-channel: RGB, dimmer 4-channel: RGBW control 5-channel: RGBW, dimmer 6-channel: RGBW, dimmer, strobe 11-channel: RGBW, dimmer, strobe, macros, auto/custom, auto speed, dimmer curve, ID addressing Static color mixing with or without DMX controller Five distinct dimmer curves Color calibration VW Features 1, 2, 3, or 6 channel DMX LED wash light (with ID addressing) Operating modes: 1-channel: Dimmer 2-channel: Color temperature macros 2-channel: Warm white, cool white control 3-channel: Dimmer, warm white, cool white, color 6-channel: Dimmer, warm white, cool white, color, temperature macros, strobe, ID addressing Static color temperature control with or without DMX controller Power settings 3

Dimensions 4

AC Power This product has an auto-ranging power supply that can work with an input voltage range of 100~240 VAC, 50/60 Hz. Power Linking This product does not support power linking. AC Plug The IP66 power input cable in this product comes bare ended. Use the table below to wire a plug for this product or see the connection diagram. IP66 Power Cable Table Connection Wire (US) Wire (Europe) IP66 Pin AC Live Black Brown 1 AC Neutral White Blue 2 AC Ground Green/Yellow Green/Yellow 3 Male Power IP66 Connector (toward fixture) Female Power IP66 Connector (toward power line) IP66 Connector Pin out Power Wiring You can connect the bare-ended IP67 rated AC power cable from the fixture to an IP66 rated power connector (Power Input and Power Output). Alternatively, you may use IP66 rated junction boxes for surface installations, or IP67 rated junction boxes for buried installations. If using connection boxes, make sure to use IP66 rated conduit for surface installations or IP67 rated conduit for buried installations. You could also use direct buried cable (DBC) to link the junction boxes. AC Power Junction Box Wiring 5

DMX Connection You can connect the bare-ended IP67 rated signal cable from the fixture to two IP66 rated signal connectors (DMX Input and DMX Output). Alternatively, you may use an IP66 rated junction box for a surface installation, or an IP67 rated junction box for a buried installation. If using boxes make sure to use IP66 rated conduit (surface), IP67 rated conduit (buried), or direct buried cable (DBC). DMX Junction Box Wiring IP66 DMX Cable Table Connection DMX In DMX Out IP66 Pin Ground Shield Shield 1 Data - Black Green 2 Data + White Red 3 IP66 Connector Pin Out Male IP66 (DMX Input) Female IP66 (DMX Output) 6

Mounting Before mounting this product, read the safety notes at the beginning of the Ilumipod 42 IP Series User Manual and follow the mounting procedures indicated in it. C Clamps (not included) Secure the safety cable using the passageway on the back of the fixture Mounting Diagram Overhead Mounting Floor Mounting 7

Control Panel Description Button <MENU> <ENTER> <UP> <DOWN> Function Exits from the current menu or function Enables the currently displayed menu or sets the currently selected value into the selected function Navigates upwards through the menu list and increases the numeric value when in a function Navigates downwards through the menu list and decreases the numeric value when in a function Password Personality References The non-modifiable password is: <UP>, <DOWN>, <UP>, <DOWN> The table below shows the meanings of the feature codes used in the Description column of the Menu Option tables. Code Description Code Description R Red DS Dimmer Speed G Green CM Color Macro B Blue WM White Macro W White S Strobe CW Cool White A Auto Programs WW Warm White AS Auto Speed D Dimmer ID ID Addressing Power Control Notes Upload Notes The VW fixtures come with power control to boost the overall light intensity. If left in HIGH power mode for too long, the fixture might return to the NORMAL power mode as its internal temperature reaches the maximum allowed value. During the upload process, the fixture indicates with colors the progress of the procedure. The table below shows the color codes for each type of Ilumipod 42 IP Optic fixture. RGBW VW Description Yellow The upload process in running Red The upload failed due to an internal error Green CW The upload ended successfully 8

Menu Options (RGBW Fixtures) 1 st Level Programming Levels Description R (red) G (green) Combines red, green, blue, and white to form a 000~255 STAT b (blue) custom color w (white) ST (strobe) 00~20 Strobe frequency (0~20 Hz) AUTO AT.1~10 Selects any of the 10 auto programs PR.1~10 Selects any of the 10 custom (editable) programs RUN dmx Operates with a DMX controller SLAVE Operates with a master fixture dmx d.001~512 Sets the DMX starting address TOUR 11 channels (RGBW, D, S, CM, A, AS, DS, ID) ARC.1 3 channels (RGB) AR1.D 4 channels (RGB, D) PERS ARC.2 4 channels (RGBW) AR2.d 5 channels (RGBW, D) AR2.S 6 channels (RGBW, D, S) HSV 3 channels (hue, saturation, value) Id Id.01~66 Assigns an ID address to the fixture R (red) Combines red, green, blue, and white to form a 000~255 custom color EDIT SET CAL1 CAL2 PR. 01~10 SC. 01~30 G (green) b (blue) w (white) Sb (strobe) 00~20 Strobe frequency (0~20 Hz) T (time) Step duration 000~255 F (fade) Fade duration UPLd (upload) Uploads custom programs to another fixture <Password> REST (reset) Resets the fixture to factory settings Id (ID addressing) ON/OFF Turns ID addressing on or off OFF Max output when RGBW faders are at 255 COLO RGbw (RGB to white) Pre-set output when RGBW faders are at 255 (color calibration) UC (Universal Color) Output matches that of older fixtures dim OFF Makes dimmer curve linear (dimmer speed) dim1~4 Changes the dimmer curve (fast slow) R (red) wt.01~11 (White temperature) RGbw (RGB to white) G (green) b (blue) w (white) R (red) G (green) b (blue) 000~255 000~255 Modifies the white temperature used in the macros channel (TOUR, channel 6) Modifies the white color used when SET > COLOR > RGbw is active KEY ON/OFF Turns the password on or off 9

Menu Options (VW Fixtures) 1 st Level Programming Levels Description w (warm white) Warm White and Cool White generate a white 000~255 STAT C (cool white) temperature (0~100%) ST (strobe) 00~20 Strobe frequency (0~20 Hz) RUN dmx Operates with a DMX controller SLAV Operates with a master fixture dmx d.001~512 Sets the DMX starting address STd.w 2 channels (WW & CW) STd.d 3 channels (WW & CW, D) PERS STd.1 2 channels (WM, D) STd.2 6 channels (WW, CW, WM, S, D, ID) UNO 1-channel (dimmer) Id Id.01~66 Assigns an ID address to the fixture UPLd (upload) Uploads custom program to another fixture <Password> REST (reset) Resets the fixture to the default, factory settings SET Id ON/OFF Turns ID addressing on or off (ID addressing) HIGH High Output (Power consumption: 150 W) POw (power) NORM Normal Output (Power consumption: 90 W) dim Off Makes dimmer curve linear (dimmer speed) dim1~4 Changes the dimmer curve (fast slow) w (warm white) CAL1 wt.01~05 (white temperature) 000~255 Modifies the white temperature used in the white macros channel (STd.2, channel 4) C (cool white) KEY ON/OFF Turns the password on or off 10

DMX Values (RGBW fixtures) TOUR 1 Dimmer 000 255 0~100% 2 Red 000 255 0~100% Step Time When running a custom program 3 Green 000 255 0~100% Fade Time When running a custom program 4 Blue 000 255 0~100% 5 White 000 255 0~100% 000 010 No Function 011 030 R: 100% G: Up B: 0% 031 050 R: Down G: 100% B: 0% 051 070 R: 0% G: 100% B: Up 071 090 R: 0% G: Down B: 100% 091 110 R: Up G: 0% B: 100% 111 130 R: 100% G: 0% B: Down 131 150 R: 100% G: Up B: Up 151 170 R: Down G: Down B: 100% 6 171 200 R, G, B, & W: 100% Color Macro + White 201 205 White 1: 3,200 K Balance 206 210 White 2: 3,400 K 211 215 White 3: 4,200 K 216 220 White 4: 4,900 K 221 225 White 5: 5,600 K 226 230 White 6: 5,900 K 231 235 White 7: 6,500 K 236 240 White 8: 7,200 K 241 245 White 9: 8,000 K 246 250 White 10: 8,500 K 251 255 White 11: 10,000 K 7 Strobe 000 010 No Function 011 255 0~20 Hz 000 020 No Function 021 030 Auto 1 031 040 Auto 2 041 050 Auto 3 051 060 Auto 4 8 Programs 061 070 Auto 5 071 080 Auto 6 081 090 Auto 7 091 100 Auto 8 101 110 Auto 9 111 120 Auto 10 11

TOUR (Cont.) 121 130 Custom 1 131 140 Custom 2 141 150 Custom 3 151 160 Custom 4 161 170 Custom 5 8 Programs (Cont.) 171 180 Custom 6 (Cont) 181 190 Custom 7 191 200 Custom 8 201 210 Custom 9 211 220 Custom 10 221 255 No Function 9 Auto Speed Adjust 000 255 0~100% (only when running auto programs) 000 009 Preset dimmer speed 010 029 Linear dimmer 10 Dimmer Speed 030 069 Dimming curve 1 (fastest) 070 129 Dimming curve 2 130 189 Dimming curve 3 190 255 Dimming curve 4 (slowest) Value Setting Value Setting Value Setting 000 009 All IDs 212 ID 23 235 ID 46 010 019 ID 1 213 ID 24 236 ID 47 020 029 ID 2 214 ID 25 237 ID 48 030 039 ID 3 215 ID 26 238 ID 49 040 049 ID 4 216 ID 27 239 ID 50 050 059 ID 5 217 ID 28 240 ID 51 060 069 ID 6 218 ID 29 241 ID 52 070 079 ID 7 219 ID 30 242 ID 53 080 089 ID 8 220 ID 31 243 ID 54 090 099 ID 9 221 ID 32 244 ID 55 100 109 ID 10 222 ID 33 245 ID 56 11 ID Addressing 110 119 ID 11 223 ID 34 246 ID 57 120 129 ID 12 224 ID 35 247 ID 58 130 139 ID 13 225 ID 36 248 ID 59 140 149 ID 14 226 ID 37 249 ID 60 150 159 ID 15 227 ID 38 250 ID 61 160 169 ID 16 228 ID 39 251 ID 62 170 179 ID 17 229 ID 40 252 ID 63 180 189 ID 18 230 ID 41 253 ID 64 190 199 ID 19 231 ID 42 254 ID 65 200 209 ID 20 232 ID 43 255 ID 66 210 211 ID 21 ID 22 233 234 ID 44 ID 45 12

HSV 1 Hue 000 255 0~100% 2 Saturation 000 255 0~100% 3 Value 000 255 0~100% ARC1 1 Red 000 255 0~00% 2 Green 000 255 0~100% 3 Blue 000 255 0~100% ARC1+D 1 Dimmer 000 255 0~00% 2 Red 000 255 0~100% 3 Green 000 255 0~100% 4 Blue 000 255 0~100% ARC2 1 Red 000 255 0~00% 2 Green 000 255 0~100% 3 Blue 000 255 0~100% 4 White 000 255 0~100% ARC2+D 1 Dimmer 000 255 0~00% 2 Red 000 255 0~100% 3 Green 000 255 0~100% 4 Blue 000 255 0~100% 5 White 000 255 0~100% ARC2+S 1 Dimmer 000 255 0~00% 2 Red 000 255 0~100% 3 Green 000 255 0~100% 4 Blue 13

DMX Values (VW fixtures) Std.1 Std.2 1 Dimmer 000 255 0~100% 2 White macro 000 255 0~100% 1 Dimmer 000 255 0~100% 2 Warm white 000 255 0~100% 3 Cool white 000 255 0~100% 4 White macro 5 Strobe 6 ID Addressing 000 010 No Function 011 050 White 1: 3200 K 051 080 White 2: 3400 K 081 110 White 3: 4200 K 111 140 White 4: 4900 K 141 255 White 5: 5600 K 000 009 No Function 010 255 0~20 Hz Value Setting Value Setting Value Setting 000 009 All IDs 212 ID 23 235 ID 46 010 019 ID 1 213 ID 24 236 ID 47 020 029 ID 2 214 ID 25 237 ID 48 030 039 ID 3 215 ID 26 238 ID 49 040 049 ID 4 216 ID 27 239 ID 50 050 059 ID 5 217 ID 28 240 ID 51 060 069 ID 6 218 ID 29 241 ID 52 070 079 ID 7 219 ID 30 242 ID 53 080 089 ID 8 220 ID 31 243 ID 54 090 099 ID 9 221 ID 32 244 ID 55 100 109 ID 10 222 ID 33 245 ID 56 110 119 ID 11 223 ID 34 246 ID 57 120 129 ID 12 224 ID 35 247 ID 58 130 139 ID 13 225 ID 36 248 ID 59 140 149 ID 14 226 ID 37 249 ID 60 150 159 ID 15 227 ID 38 250 ID 61 160 169 ID 16 228 ID 39 251 ID 62 170 179 ID 17 229 ID 40 252 ID 63 180 189 ID 18 230 ID 41 253 ID 64 190 199 ID 19 231 ID 42 254 ID 65 200 209 ID 20 232 ID 43 255 ID 66 210 ID 21 233 ID 44 211 ID 22 234 ID 45 14

Std.w 1 Warm white 000 255 0~100% 2 Cool white 000 255 0~100% Std.d 1 Dimmer 000 255 0~100% 2 Warm white 000 255 0~100% 3 Cool white 000 255 0~100% UNO 1 Dimmer 000 255 0~100% 15

Contact Us General Information ILUMINARC 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 923-3680 Fax: (954) 929-5560 World Wide Web (ATTN: ILUMINARC ) www.iluminarc.com Ilumipod 42 IP Series QRG Rev. 02 Copyright 2011 ILUMINARC All rights reserved Printed in the P. R. C. 16