ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

Similar documents
ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C17Q. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

ATS22C14Q meki upuštač ATS22 upravljanje 220V-snaga 230V (37kW)/ V(75kW)

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

RM35LM33MW liquid level control relay RM35-L V AC/DC

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

ATV320U06N4C variable speed drive ATV kW V - 3 phase - compact

ZBRN1. Main. Device short name

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

ATV61HC31Y variable speed drive ATV61-310kW - 690V - without EMC filter

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

RM4TR31 three-phase network control relay RM4-T - range V

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

TM3DI16G module TM3-16 inputs spring

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE9RA21MW7 off-delay timing relay s V AC -

RM35LM33MW liquid level control relay RM35-L V AC/DC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ATV212WD30N4 variable speed drive ATV212-30kW - 40hp - 480V - 3ph - EMC class C2 - IP55

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

ATV212WU55N4 variable speed drive ATV kW - 7.5hp - 480V - 3ph - EMC class C2 - IP55

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV212WU40N4 variable speed drive ATV212-4kW - 5hp - 480V - 3ph - EMC class C2 - IP55

RM4TA32 three-phase network control relay RM4-T - range V

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

RM4JA31M current measurement relay RM4-J - range ma V AC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

ATV212HD18N4 variable speed drive ATV kW - 25hp - 480V - 3ph - EMC - IP21

RM4LA32M liquid level control relay RM4-L V AC

TM3SAF. Main. Device short name

LMC058LF42 compact base - 42 I/O - 24 V DC supply

RM35TF V AC

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

ATV61HC11N4 SPEED DRIVE 150 HP 460 V ATV61

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

ATV212HD15N4 variable speed drive ATV212-15kW - 20hp - 480V - 3ph - EMC - IP21

ATV212HD11N4 variable speed drive ATV212-11kW - 15hp - 480V - 3ph - EMC - IP21

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

HMIGTO2300. Main. External source. Chinese (simplified Chinese) Japanese (ANK, Kanji) Korean Taiwanese (traditional Chinese)

ILS1M851PB1F0 integrated drive ILS with stepper motor V - I/O for motion sequence - 5A

TM241CE24T controller M IO transistor PNP Ethernet

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

TM241CE40R controller M IO relay Ethernet

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

ATV212HD75N4. Main. Range of product Altivar 212. Device short name. Motor power hp 160 A 460 V khz with derating factor

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

Transcription:

Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product specific application Component name Phase Soft starter Asynchronous motors Pumps and fans ATS22 3 phases [Us] rated supply voltage 208...600 V - 15...10 % Motor power hp Factory setting current Power dissipation in W Utilisation category Type of start IcL starter rating IP degree of protection With heat sink Internal bypass 177...660 V Supply frequency 50...60 Hz - 10...10 % Network frequency Device connection [Uc] control circuit voltage Control circuit consumption Discrete output number 2 Discrete output type Minimum switching current Maximum switching current Discrete input number 3 Discrete input type Discrete input voltage Discrete input logic Output current PTC probe input Communication port protocol Connector type Communication data link Physical interface Transmission rate Installed device 31 Protection type 45...66 Hz In the motor supply line 110 V -15...10 % 50/60 Hz 20 W 20 hp 208 V 25 hp 230 V 50 hp 460 V 60 hp 575 V 65 A 63 W for standard applications AC-53A Start with torque control (current limited to 3.5 In) 75 A connection in the motor supply line for standard applications IP20 Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O 100 ma 12 V DC relay outputs 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs Logic LI1, LI2, LI3 5 ma 20 kohm 110 V <= 121 V Positive logic LI1, LI2, LI3 < 20 V and <= 15 ma > 79 V <= 2 ma 0.4...1 Icl adjustable 750 Ohm Modbus 1 RJ45 Serial RS485 multidrop 4800, 9600 or 19200 bps Thermal protection motor 1 / 8 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Marking Type of cooling Operating position Height Width Depth Product weight Phase failure line Thermal protection starter CE Forced convection Vertical +/- 10 degree 11.61 in (295 mm) 5.71 in (145 mm) 8.15 in (207 mm) 26.46 lb(us) (12 kg) Environment electromagnetic compatibility Conducted and radiated emissions level A IEC 60947-4-2 Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/current impulse level 3 IEC 61000-4-5 standards EN/IEC 60947-4-2 product certifications CCC CSA C-Tick GOST UL vibration resistance 1 gn 13...200 Hz EN/IEC 60068-2-6 1.5 mm 2...13 Hz EN/IEC 60068-2-6 shock resistance 15 gn 11 ms EN/IEC 60068-2-27 noise level 45 db pollution degree Level 2 IEC 60664-1 relative humidity 0...95 % without condensation or dripping water EN/IEC 60068-2-3 ambient air temperature for operation ambient air temperature for storage operating altitude 14...104 F (-10...40 C) without derating > 104...< 140 F (> 40...< 60 C) with current derating 2.2 % per C -13...158 F (-25...70 C) <= 3280.84 ft (1000 m) without derating > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m Offer Sustainability Green Premium product Compliant - since 0939 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available Green Premium product Compliant - since 0939 - Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Available Available Contractual warranty Warranty period 18 months Frame Size B Dimensions 2 / 8

Precautions Standards The Altistart 22 soft starter is compliant with pollution Degree 2 as defined in NEMA ICS1-1 or IEC 60664-1. For environment pollution degree 3, install the Altistart 22 soft starter inside a cabinet type 12 or IP54. Air Circulation DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH ATS22 soft starters are open devices and must be mounted in a suitable enclosure. Failure to follow these instructions will result in death or serious injury. Leave sufficient free space to help the air required for cooling purposes to circulate from the bottom to the top of the unit. Overheating To avoid the soft starter to overheat, respect the following recommendations: Mount the Altistart 22 Soft Starter within ± 10 of vertical. Do not locate the Altistart 22 Soft Starter near heat radiating elements. Electrical current through the Altistart 22 Soft Starter will result in heat losses that must be dissipated into the ambient air immediately surrounding the soft starter. To help prevent a thermal fault, provide sufficient enclosure cooling and/or ventilation to limit the ambient temperature around the soft starter. 3 / 8

If several soft starters are installed in a control panel, arrange them in a row. Do not stack soft starters. Heat generated from the bottom soft starter can adversely affect the ambient temperature around the top soft starter. Mounting Connection Between the Fan and the Altistart 22 Soft Starter 1 Altistart 22 Soft Starter 2 Fan Wall mounted or Floor-standing Enclosure with IP 23 Degree of protection Introduction To help proper air circulation in the soft starter, grilles and forced ventilation can be installed. Ventilation Grilles Forced Ventilation Unit Power Terminal Cage Style 4 / 8

1 Ground connection Power connections, minimum and maximum wiring capabilities, tightening torque IEC cable UL cable Power supply and output to motor Size/gauge min 4 mm (a) 10 AWG (a) max 50 mm 1/0 AWG Tightening torque min 8 N.m 70 lb.in max 8 N.m 70 lb.in Strip length 15 mm 0.6 in. Power connections, minimum required wiring section IEC cable mm² (Cu 70 C/158 F) (1) UL cable AWG (Cu 75 C/167 F) (1) 25 3 110 Vac control, Logic Inputs (LI) 110 Vac, 3-wire control 5 / 8

110 Vac control, Logic Inputs (LI) 110 Vac, 2-wire control, freewheelstop Motor Thermal Protection - Cold Curves Curves 6 / 8

A Class 10 B Class 20 C Class 30 Trip time for a Standard Application (Class 10) 32 s Trip time for a Severe Application (Class 20) 63 s Trip time for a Severe Application (Class 30) 95 s Motor Thermal Protection - Warm Curves Curves 7 / 8

A Class 10 B Class 20 C Class 30 Trip time for a Standard Application (Class 10) 16 s Trip time for a Severe Application (Class 20) 32 s Trip time for a Severe Application (Class 30) 48 s 8 / 8