RS-485 module. Data sheet. for electricity meters

Similar documents
Analog input module. Data sheet. for MULTICAL 603

M-Bus Master. Data sheet. MultiPort 250D/L

M-Bus Master MultiPort 250D/L

M-Bus Modules. Data sheet. for MULTICAL 403

Wired M-Bus Modules. Data sheet. for MULTICAL 403 and 603

/ Type approved according to:

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

BACnet MS/TP-module. Data sheet. for MULTICAL 403 and 603

Modbus Module. Data sheet. Communication module for MULTICAL 403 and MULTICAL 603

Interface RS485-TTL CODE: INTR. v.1.0 EN* Edition: 3 from

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

LON-module for MULTICAL 601

USB RS485 High Isolated Industry Converter Box for DIN Rail - product #248

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Manual Industry Interfaces

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

GSM Modem 5. Installation and User Guide. English

SCB-C08 USB to RS232/422/485 Converter

Serial Communication Converters & Adapters Instruction Manual

Interface description. Kamstrup HAN-NVE interface description

M-Bus Master MultiPort 250D

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

CS485. User s Manual. Version ZYPEX, Inc.

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

DATA CONNECT ENTERPRISE

USB-COM Plus ISO (USB-COMi SI-M)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

MODEL: R2K-1 SEN TRONIC AG. R2K Series

USB RS-485/422 Communication adapter virtual serial port ELO E211. Operation manual

Manual Fiber Optic Interfaces

PCI Express 4-Port Industrial Serial I/O Cards

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Wireless M-Bus modules for MULTICAL 403 & 603

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

Modbus Communications October Programming Meters fitted with the Modbus option have two additional stages in the front panel programming menu.

RS485 3 click. How does it work? PID: MIKROE-2821

Media Converters. Media Converters. Product Selection Guides

MODEL USB-FLEXCOM4. USB to Four RS-232/422/485 Serial Ports and MODEL USB-COM232-4A USB to Four RS-232 Serial Ports USER MANUAL

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

R507 I.S. Interface Module User Manual

UC-2000 Installation Manual Unicorn Computers Technology Limited

C-DIAS Serial Interface CSI 021

T1K MODBUS Base Controller Specifications

Moxa TCC-100 Series Hardware Installation Guide

ICF-1150 Series Quick Installation Guide

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

SST-2450 Wireless Modem User s Manual

MED102A. Industrial Serial to Single-mode Fiber Converter

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

USB RS-485/422 Communication adapter virtual serial port ELO E216. Operation manual

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

icex-cmtm General specs and Installation guide

TRP-C07 User s Manual

S800 I/O ABB Automation

MODEL USB-COM-2SM USER MANUAL

ICF-1150 Series Quick Installation Guide

RS485 MODBUS Module 6RO

I-7570 Serial To HART Converter

USB to RS-232/RS422/485. US-101-I USB To Serial Operation Manual

MRUC-20 Modul-R CAN Bus Network

Neon pr. ph/ ORP measurement. Applications. Description

IFC 100 Supplementary instructions

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

Technical Documentation, RTCU-SA

Accessories IC690ACC900

C160 Wall-/Pipe Mounted Universal Process Indicator

ADAPTER CARDS TRADITIONAL STANDALONE. DATA SHEET page 1/14. Description

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

Solution description. READy. The modern and efficient solution for reading smart water, heat and cooling meters

Introduction. General Ratings

FEATURES. N.1 serial interface RS-485 Modbus RTU Master. N.1 serial interface RS-485 Modbus RTU Slave. Interface Ethernet 10Base-T, Modbus TCP

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Product Description. Altus S. A. 1

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

Communication module to connect M-bus devices to POL6xx.xxx controllers.

TRP-C08S. USB to 1 RS232 and 1 RS422/485 Isolated Converter. User s Manual

USB to RS-232/RS422/485. URK-228-I USB To Serial Operation Manual

MODEL: GR8-EM. Communication Adaptor GR8 Series

TRP-C08. USB to RS232/422/485 Isolated Converter. User s Manual. Printed Sep.2014 Rev 1.4

Jazz-J. Jazz. Features:

Moxa TCC-100 Series User s Guide

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

Features and Benefits. Certifications

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

MIC-2 Multi-instrument DATA SHEET

Installation and user s guide GSM8H - 3G. Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: kamstrup.

W&T Manual Interface modules W&T

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

PLC PL User Manual

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan

MOD-MBUS CONFIGURATOR SOFTWARE (Series 2) User Guide

Wall-/Pipe Mounted Universal Process Indicator

A general-purpose industrial input/output

Transcription:

Data sheet RS-485 module for electricity meters RS-485 electrical interface for direct access to meter(s) Share GSM/GPRS modem connect up to 32 electricity meters Galvanically separated serial communication Two-wire, half-duplex connection Cable length up to 1200 m Compliant with EIA-485 DLMS and KMP protocols Baudrate 300-9600 baud 5A load control or 230 VAC tariff control

Contents Application 3 Installation example 3 Technical data 4 Connection details RS-485 5 Tariff control on module port 5 Connection details RS-485 (add-on) 6 Installation 6 Order specifications 7 2 Kamstrup A/S 58101031_F1_GB_09.2016

Application The RS-485 module is used as a serial communication interface for direct access to the electricity meter and by that relevant meter data. From electricity meter Kamstrup 162/382 generation M [SW Rev. AF1], Kamstrup 351 generation C [SW Rev. P1] and OMNIPOWER variant 1 [SW Rev. V1], the module provides a reliable multi drop electrical interface, supporting the Kamstrup electricity meter DLMS and KMP protocols. The communication interface is compliant with the RS-485 standard published by the Electronic Industries Alliance (EIA). The differential signal and twisted pair cabling make the RS-485 resistant against electrical noise. The simple bus wiring and long cable length also makes it ideal for use in building automation. The module supports either a 5A load control output or a 2-tariff control input using 230 V. Installation example In multidrop communication mode, the electricity meter s communication address (DLMS or KMP) needs to be programmed. This can be done using METERTOOL. NOTE! Multidrop communication is not supported by Kamstrup systems, but can be used together with external systems. Kamstrup A/S 58101031_F1_GB_09.2016 3

Technical data RS-485 Slave Module RS-485 Master Module (Add-on) Electrical data Supply Internally via the electricity meter Power consumption 0.6 W Connection terminals 0.15 mm² 2.5 mm² Operating temperature -40 C - +70 C Mechanical data Storage temperature -40 C - +85 C Relative humidity < 90 % Weight Approximately 30 g Dimensions, W x L x H 42 x 92 x 16 mm 42 x 75 x 29 mm Marking/approvals CE marking Meets the demands of the electricity meter Data/Communication Serial communication 300-9600 baud 9600 (GSM8i modem must be configured for DLMS or KMP transparent communication) Signals Tx+/Rx+, Tx-/Rx-, Half duplex Recommended cable Twisted pair communication cable RS-485 input impedance 1 unit load Load control output Voltage rated 230 VAC Max current 5A/1250 VA Isolation voltage (open contact) 1000 V Tariff control input Control voltage 230 VAC +10 %/-15 % Control current < 2 ma Input is galvanically isolated from the meter 4 Kamstrup A/S 58101031_F1_GB_09.2016

Connection details RS-485 The RS-485 module is mounted on the modular area in the electricity meter using 8 pins module interface. 5A load control relay 19 NO 18 Common 17 NC Tarif input 13 External 0 or 230 VAC 15 External 0 VAC RS-485 communication 138 Tx+/Rx + 137 Tx-/Rx - 6850-072 Tariff control on module port Terminal 13 Terminal 15 Active tariff Active tariff inverted 0 VAC 0 VAC T1 T2 230 VAC 0 VAC T2 T1 Kamstrup A/S 58101031_F1_GB_09.2016 5

Connection details RS-485 (add-on) The RS-485 (add-on) module is mounted on a GSM8i module in the module area in the electricity meter using 8 pins module interface. 5A load control relay 19 NO 18 Common RS-485 communication 138 Tx+/Rx + 137 Tx-/Rx - 6845-004 Installation It is possible to connect up to 32 electricity meters using RS-485 the RS-485 option is available as add-on for GSM8i 2G and GSM8i 3G. The galvanically isolated serial communication supports half-duplex and is designed for maximum 9600 bps. The RS-485 interface is available on GSM8i port B only, and thus an external antenna is required for GSM8i 3G. The multidrop concept does not support alarms these shall be disabled in the meters in advance. The topology of an RS-485 network using Kamstrup isolated and failsafe RS-485 slave or add-on modules. Max 32 unit loads on RS-485 bus The RS-485 bus shall be un-terminated RS-485 pull up/down resistors 33 K 6 Kamstrup A/S 58101031_F1_GB_09.2016

Order specifications Description Type no. RS-485 Slave Module 6850-072 RS-485 Slave Module (Add-on) 6845-004 GSM8i 2G with RS-485 add-on 6819-060-00000 GSM8i 3G with RS-485 add-on 6817-060-00000 Kamstrup A/S 58101031_F1_GB_09.2016 7

Kamstrup A/S 58101031_F1_GB_09.2016 Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 F: +45 89 93 10 01 info@kamstrup.com kamstrup.com 8 Kamstrup A/S 58101031_F1_GB_09.2016