CHENBRO. 6-Port 3Gb/s Mini-SAS Backplane 80H A0. User s Manual. August / 2010

Similar documents
CHENBRO. 8-Port 6Gb/s SATA Backplane 80H A0. User s Manual. September / 2010

CHENBRO. SR30169 Server Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 80H A0. Revision: 1.1. Dec / 3 / 2013

CHENBRO. 4-Port SAS / SATA-II Backplane 80H User s Manual. Version 1.1~1.3. July / 18 / 2008

CHENBRO. 80H A0 Rev A0 User s Manual 01 / 03 / 2011

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H User s Manual. Version A0. July / 28 / 2008

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H C0. User s Manual. September / 10 / 2009

CHENBRO. 24-Port 3.5 mini-sas Backplane with Expander 80H A0. User s Manual. December 2012

CHENBRO. User s Manual port 6Gb/s SAS Expander Backplane 80H A0. Version A0

80H A0 80H A0 80H A0

CHENBRO. User s Manual SK to-1 SATA / SAS HDD Storage Kit. Version A2~A4. May / 26 / 2008

In Win. Storage Chassis 10-Port 6Gb/s 2.5 Mini-SAS+SATA Backplane. User s Manual 2014/8/10

Chenbro. ES34169 Chassis User s Manual. April / 2 /

CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009

SAS Expander Card User s Manual CHENBRO. SAS Expander Card User s Manual. April / 01 /

In Win. Storage Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 2015/08/06

In Win. Storage Chassis 4-Port 6Gb/s SAS/SATA Backplane 3RAMPD User s Manual 10/02/2012

CHENBRO CK port 6Gbit SAS Expander Card User s Manual. Version A0. September / 01 / 2010

RM414 User s Manual. Preliminary Release

A33606-PCI-01 SAS-2 Expander User Manual. Version: Document Number:

SAS JBOD Installation Reference Guide Revision 1.0

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

Copyright. Technical Support. Web Support. Support. Phone Support. Copyright 2006 Chenbro Micom Co., Ltd.. All rights reserved.

CSE-M14T Mobile Rack USER'S GUIDE

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

RM238 Series. Rackmount Chassis User Manual. January 2019 Version 1.0

NA380A-G3. 4U 24-Bay External PCIe 8 JBOD Storage with PCIe Slot Expansion. User Manual

Wiwynn SV320 Maintenance User Manual

DNS-2608 Enterprise JBOD Enclosure User Manual

A12S2-PS. Quick Start Guide. August, 2012 V.1.4

Installation manual Digital Energy USB / RS232 / Relay Interface Card for use with GE Digital Energy VH Series UPS VA

RACK-220 CHASSIS USER S MANUAL

A33606-AIC-02 User's Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide

MegaRAID SAS e RAID Controller

HighPoint NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual

NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual

SAS-933E The SAS-933E2/E1 Storage Backplane USER'S GUIDE

MegaRAID SAS 9285CV-8e RAID Controller. Quick Installation Guide

User Guide - English. FUJITSU Software ServerView Suite. Local Service Panels. Local Service Concept (LSC)

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness

FWA-6280A User Manual 1. FWA-6280A User Manual

HOME THEATER PC CHASSIS

CyberBlock SATA. User Manual. Meiya Pico Information Co., Ltd.

RMC HS. User Manual. Version 1.0

LSI SAS i PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

PAC-125 CHASSIS USER S MANUAL

Home Theater PC Chassis

Turbo PCI Express. PCI Express adapter for desktop PC. PCIe 4 to PCIe 4 data cable, 1.5 meter. Turbo ExpressCard. ExpressCard 34 adapter for laptop

ESS Series Internet Intelligent Storage Quick Start Guide

RSC-1R Rackmount Storage Chassis User's Manual

Intel Storage Server SSR212MC2

BPN-NVMe3-116UN Backplane USER'S GUIDE

User Manual ACP-2320MB. 2U-high Rackmount Chassis with Dual SAS/SATA HDD Trays

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

SR2611-2S-S2R+ (6G) (2 CD-ROM Bays for Two 2.5"-3.5 HDD/SSD Internal RAID Module)

EAGE1040TG-PM EAGE540TG-PM EAGE8402TG-ES EAGE4402TG-ES

SAFETY PRECAUTIONS. Warnings

Rocsecure NE52 NAS System

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

XL-RAID-213SA User Manual

SIDEBAND#2 3 JP43 JP37 JP45 JP38 JP41 J10 I C#2 JP36 JP50:I2CRST#1 JP38:I2CRST#2 OFF:SGPIO ON:I2C JP50 JP29 2 I C#1 JP40 JP44 JP51 JP29:9072 RESET

Quanta JB9 (M4600H) JBOD System Overview

MEC-SAT-M002. User s Manual

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

MSC8144AMC-S Getting Started Guide

ST5650-4S-U5 ST7610-4S-U5 User Manual

Chassis (FRU) Replacement Guide

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Intel /100Mbps Ethernet Controller 32bit PCI Slot x2. ATI Rage XL Video Chip with 4MB Video RAM onboard 64bit PCI Slot x4

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Three Hundred. User s Manual Manuel de l utilisateur Anwenderhandbuch Manuale per l operatore Manual del usuario

05-023r0 SAS-1.1 Connector figures 23 December 2004

3. Specifications I Features System Requirements Creating A New Partition / Formatting The Hard Drive RAID Mode Selection...

Chenbro RM238 Series Spares/Accessories List and Configuration Guide

Dell EMC ME4 Series JBOD 5U84 Enclosure

WALLET-FRIENDLY INTENSITY

InTANK Series ir2620-2s-s2 / SR2611-2S-S2R User Manual

TB-FMCH-TYPER Hardware User Manual TB-FMCH-TYPER. Hardware User Manual Rev.2.01

1U Device Expansion Unit Configuration Guide

CASE VERSIONS. VG6-W RGB (3x 120 mm Addressable RGB LED Fans) VG6-W Blue (3x 120 mm LED Fans) VG6-W Red (3x 120 mm LED Fans)

PCI EXPRESS BACKPLANES USER GUIDE. Express7-G3 Express9 Express9-G3 Express11-G3. Version 1.0.0

NA265A. External PCIe 3.0 to GPU Rackmount Enclosure. User Manual

FUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

Intel RAID Controller RS3DC040/ RS3DC080 Quick Installation User's Guide

Cube YY-0420/0430 Technical Instruction

RAID Rack (RR2035RPHMS)

TB-SUB-CLK2 Hardware User Manual

SAS-833TQ BACKPLANE USER'S GUIDE

Veritas Appliance Hardware Service Procedure

UT_S Gbps SAS/SATA

Package Contents: EZ SWAP 4 Removable Hard Drive Rack. EZ Swap 4 Key SATA Cable Installation Screws User s Manual

HP ProLiant DL165 G7 Server

RM12_1394B. User Manual. Ver Date: 02/2006.

RAID Controller Considerations

High Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide

Transcription:

CHENBRO 6-Port 3Gb/s Mini-SAS Backplane 80H10321709A0 August / 2010 1

Copyright Copyright 2010 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are copyrighted by Chenbro Micom Co., Ltd.. All rights reserved. No part of this manual, either text or image may be used for any purpose other than internal use within purchasing company. Therefore, reproduction, modification in any form or by any means, electronic, mechanical or otherwise, for reasons other than internal use, is strictly prohibited without prior written permission. Chenbro Micom Co., Ltd. reserves the right to make improvement and modification to the products indicated in this manual at any time. Specifications are therefore subject to change without prior notice. Information provided in this manual is intended to be accurate and reliable. However, Chenbro Micom Co., Ltd., assumes no responsibility for its use, nor for any infringements upon the rights of third parties, which may result from its use. Technical Support Chenbro works hard to offer our customers maximum performance from our chassis. But in case you have any problem with our product you can find supports from the following resources. Web Support Detail information of our products is in our website. You can find technical updates, installation guides, FAQs, technical specifications and more. Our web address is: www.chenbro.com. Email Support You can also fill out the technical support form at our Technical Support page. Your technical issue inquiries will be sent directly to our support professionals. Phone Support You can also contact Chenbro HQ or branch office for immediate support; contact Information is as following: Chenbro HQ Chenbro Europe B.V. Chenbro Micom (USA) Inc. Tel: 886-2-8226-5500 Tel: 31-40-295-2045 Tel: 1-909-947-3200 Fax: 886-2-8226-5423 Fax: 31-40-295-2044 Fax : 1-909-947-4300 Chenbro UK LTD Chenbro China Office Tel: 44-(0)161-973-8152 Tel: 86 010-6709-1786 Fax: 44-(0)161-962-8653 Fax: 86 010-6709-1786 2

Contents Copyright... 2 Technical Support... 2 Contents... 3 Safety Instruction... 4 Revision History... 4 3Gb/s Backplane Specification.....5 Accommodation Chassis 5 Backplane Layout... 6~8 Fabricate sequence.....9~11 3

Safety Instruction CAUTION: Informs the user of conditions that might result in damage to hardware, corruption of customer data or application software, or long-term health hazard to people. A caution always precedes the information to which it relates. WARNING: Alerts the user to conditions that might result in injury or death. A warning always precedes the information to which it pertains. Revision History Date Modifications August / 04 / 2010 First release 4

3Gb/s Backplane Specification P/N: 80H10321709A0 Host Interface HDD Interface Hot-Swap 2 x Mini-SAS interface (SFF-8087) for host side (w/lock housing), port distribution should be 4+2 SAS (15+7+7) and SATA-II (15+7)compatible with 3.5 HDD Hard driver can be replaced during the system on LED indicates HDD status (Defined by Chenbro) Display Power LED Blue light (HDD is on) Access LED Green flash (HDD is working) Error indicator Red light (HDD is abnormal) Cooling 3-pin fan connector x 4 Power Connector Standard +5V and +12V 4-pin power connector x 2 2-pin power alarm connector x 1 2-pin alarm mute connector x 1 Other Connectors Dimension Material 12-pin fan and temp function switch 4-pin SGPIO function switch 4-pin HDD fail connector x 2 7-pin fan fail LED / power mute LED / global mute switch 257.3 mm (Length) x 30.0 mm (Width) x 2.4 mm (Thickness) FR4 6 layer Accommodation Chassis RM21706 5

Backplane Layout Backplane Connectors Front View Rear View (1) [LD011 / LD021 / LD031 / LD041 / LD051 / LD061] : Blue lights on indicated hard drive is power on. (2) [LD012 / LD022 / LD032 / LD042 / LD052 / LD062] : Green lights flash indicated hard drive is working. Red lights on indicated hard drive abnormal or malfunction. (3) [JF1 / JF2 / JF3 / JF4] : Fan connector (3pin) 6

(4) [CN01 / CN02] : Power connector (+5V and +12V 4pin) (5) [J15] : Alarm mute connector (To redundant power supply) (6) [J14] : Power supply abnormal alarm connector (From redundant power supply) (7) [CN3 / CN6 / J1] : Reserved for Chenbro use only. (8) [SW1] : Fan and Temp function switch. Pin Number Monitor On Off 1 Fan1 Enable Disable 2 Fan2 Enable Disable 3 Fan3 Enable Disable 4 Fan4 Enable Disable 5 TEMP 65 degc 55 degc 7

(9) [SW2] : SGPIO function switch. Pin Number SGPIO On Off 1 SGPIO Active Enable Disable 2 SGPIO Fail Enable Disable (10) [J4 / J7] : HDD fail connector (From raid card) Pin 4 3 2 1 Define HDD 1 HDD 1 HDD 1 HDD 1 Pin 8 7 6 5 Define N/A N/A HDD 1 HDD 1 (11) [J12] : Jump of fan fail LED & Power temp fail LED & Global mute switch Pin 1 2 3 4 Defin FAN FAIL FAN FAIL POWER / TEMP POWER / TEMP e LED + LED - FAIL LED + FAIL LED - Pin 5 6 7 8 Defin GLOBAL GLOBAL GND Key pin e MUTE MUTE SWITCH + SWITCH - (12) [CN011 / CN021 / CN031 / CN041 / CN051 / CN061] : To connect with hard driver (22-pin SATA-II or 29-pin SAS). The CN011 & CN021 & CN031 & CN041 are controlled by MiniSAS CN1. The CN011 & CN021 are controlled by MiniSAS CN2. 8

Fabricate sequence 1. Screw the backplane with the bracket. CN1 CN2 Note: HDD grouping definition responds to above yellow mark 2. Screw the backplane bracket with the hard drive cage. 9

3. The front LED board is connected with the fan fail LED & power temp LED & global mute switch to backplane. [JF12] 4. The middle fans are connected to the header on backplane. [ JF1 / JF2 /JF3 / JF4] 5. The MiniSAS connector are connected with the MiniSAS cable. [CN1 / CN2] 10