Ethernet Access. Data sheet for the MEF-Defined E-Access Service Type

Similar documents
Ethernet Access. Data sheet for the MEF-Defined E-Line Service Type

EZ ETHERNET A SIMPLE, EASY-TO-CONNECT ALTERNATIVE FOR LOW-BANDWIDTH ETHERNET ACCESS

L2CONNECT 2.0 E-ACCESS

MetroEthernet Options

Technical Specification MEF 6. Ethernet Services Definitions - Phase I. June 2004

Technical Specification MEF 13. User Network Interface (UNI) Type 1 Implementation Agreement. November, 2005

MEF Certification Update

MEF Certification Update

MEF Certification Update

Technical Specification MEF 27. Abstract Test Suite For. May 20 th, 2010

Service Definition E-Line Service

NBN Co Ethernet Bitstream Service - FTTB/FTTN

Service Definition Internet Service

Technical Specification MEF 37. Abstract Test Suite for ENNI. January 2012

Technical Specification MEF 1. Ethernet Services Model, Phase November 2003

IxANVL : Metro Ethernet Test Suites

Product Technical Specification

CUSTOMER DATA FORMAT REQUIREMENTS

GTS Ethernet line is designed so as to be compliant with the specifications of the MEF 6.1 and MEF 10.2 standards.

Developing Standards for Metro Ethernet Networks

NBN Co Ethernet Bitstream Service Product Technical Specification 19 December 2013

NBN Co Ethernet Bitstream Service

EPIPE Product Description

Technical Specification MEF 10. Ethernet Services Attributes Phase 1. (Obsoletes MEF 1 and MEF 5) November 2004

SERVICE DESCRIPTION ETHERNET /v4.3

SERVICE DESCRIPTION ETHERNET /v4.6

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 2

Chapter 4 Configuring Switching

Technical Overview Ethernet BA Service

MEF-CECP Certification Exam Blueprint "D"

ISCOM2948GF-4C Intelligent Ethernet Service Aggregation

Technical Specification MEF External Network Network Interface (ENNI) Phase 2. January 2012

Dual hot-swappable power supply, with voltage/temperature alarms

Metro Ethernet Services A Technical Overview Ralph Santitoro

TDS Wholesale Carrier Ethernet Services. TDS Mobile Backhaul Service Description

Technical Specification. Amendment to MEF 45: OVC Services Requirements for L2CP. August, 2017

UFB Ethernet Access Service Description

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 3

Highlights. Datasheet ISCOM2924GF-4C. defined E-Line and with specifications. Network Security. control, & Management. Advanced QoS.

Highlights. Datasheet. defined E-Line and with specifications. Network Security. control, & Management. Advanced QoS.

IEEE 802.1ad Support on Provider Bridges

ISCOM RAX 711 (B) Ethernet Demarcation Device

Carrier Ethernet Service

ITU-T G /Y

NBN Co Fibre Access Service PRODUCT TECHNICAL SPECIFICATION

Understanding Bandwidth Profiles in MEF 6.2 Service Definitions

Chorus UFB Services Agreement Service Description for Bitstream 2

S2250/S3250 NETWORK INTERFACE DEVICE

Technical Specification MEF 14. Abstract Test Suite for Traffic Management Phase 1. November, 2005

Enable Networks UFB Services Agreement Bitstream Services: Service Description for Multicast Service

Configuring Ethernet Virtual Connections on the Cisco ASR 1000 Series Router

Service description ETHERNET

24-Port 10/100 L3 Switch Model: Web Configuration Guide

Ethernet Virtual Connections Configuration

Small Enterprise Design Profile(SEDP) WAN Design

Product features. Applications

COMCAST ENTERPRISE SERVICES PRODUCT-SPECIFIC ATTACHMENT ETHERNET TRANSPORT SERVICES

User Guide. Unmanaged Pro Switch TL-SG105E/TL-SG108E/TL-SG116E REV4.0.1

MEF Standard MEF Subscriber Ethernet Service Attributes. December 2018

NETWORK SERVICES: ETHERNET WAN ETHERNET SERVICES PRODUCT PORTFOLIO SUMMARY DOCUMENT

Hands-On Metro Ethernet Carrier Class Networks

FSOS. Ethernet Configuration Guide

Multi Service Port (MSP)

MEF Standard MEF 51.1

Highlights. Datasheet ISCOM2128EA-MA. comboo GE network. Network Security. control, Aggregation. & Management. Advanced QoS. Support IGMP.

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Enable Networks UFB Services Agreement Service Description for Bitstream 2a. Version 1.21 FebSept 20176

Datasheet. Managed Gigabit Fiber Switch. Model: ES-12F. Non-Blocking Throughput Switching. High Performance and Low Latency

Technical Specification MEF 51. OVC Services Definitions. August 2015

Sections Describing Standard Software Features

Technical Specification MEF External Network Network Interfaces (ENNI) and Operator Service Attributes. August 2016

Transient Traffic Interruption on Ports Due to Source MAC Address Attacks Troubleshooting. Table of Contents

Gigabit EasySmart Switches

Gigabit Managed Ethernet Switch

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Product Technical Specification

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Datasheet. comboo GE network. Highlights. Network Security. control, & Management. Advanced QoS. U.S.A. Headquarters.

Support STP/RSTP/MSTP, redundant links and IEEE 802.3ad Link Aggregation

SOLO NETWORK (11) (21) (31) (41) (48) (51) (61)

Carrier Ethernet Interconnect

Datasheet. 10G 16-Port Managed Aggregation Switch. Model: ES-16-XG. Non-Blocking Throughput Switching. Maximum Performance and Low Latency

ETX-201A Carrier Ethernet Demarcation Device

SWP-0208G, 8+2SFP. 8-Port Gigabit Web Smart Switch. User s Manual

RICi-16 Ethernet over Bonded PDH Network Termination Unit

Annex Service Specifications

Cisco Small Business Managed Switches

User Guide. Unmanaged Pro Configuration Utility TL-SG105E / TL-SG108E / TL-SG116E TL-SG1016DE / TL-SG1024DE / TL-SG108PE / TL-SG1016PE

Technical Specification. Ethernet Services Attributes for Subscriber Services. 13 July 2017

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: ES W, ES W, ES W, ES W

HP 5120 SI Switch Series

HUAWEI AR Series SEP Technical White Paper HUAWEI TECHNOLOGIES CO., LTD. Issue 1.0. Date

Designing Next Generation Carrier Ethernet Access Network. Benjamin Lee Session ID 20PT Consulting Systems Engineer

RICi-16 Ethernet over Bonded PDH Network Termination Unit

MEF Standard MEF Layer 2 Control Protocols in Ethernet Services. December 2018

Low Cost 26 Port 10 GbE and GbE ATCA Switch

Metro Ethernet Design and Engineering for CO

FLASHWAVE 5320 Ethernet Services Platform

Sections Describing Standard Software Features

Configuring Interfaces

Transcription:

Ethernet Access Data sheet for the MEF-Defined E-Access Service Type

General RELATED DOCUMENTS SUPPORTED MEF SERVICE TYPES 1 SERVICE SPEEDS 2 Telstra Wholesale fact sheet: https://www.telstrawholesale.com.au/products/data/ethernet.html Telstra Service Interface Specification (TSIS) [commercial-in-confidence] TSIS Addendum for E-Access [commercial-in-confidence] E-Access: Access EPL (Port-based at the UNI) Supported on all access types Access EVPL (VLAN based at UNI) Only supported on Telstra Fibre accesses 0.256 Mbps to 1Gbps Telstra Fibre Accesses: 0.512 Mbps to 1Gbps Telstra Copper Accesses: 0.256 to 10Mbps NBN Accesses, FTTP: 5, 10, 20, 30, 40 & 50 Mbps FTTN and FTTB: 5 Mbps & 10 Mbps ENNI Attribut es (Aggregated Head End) INTERFACE TYPES INTERFACE MODES ACCESS TYPE ENNI ACCESS AVAILABILITY TARGET 10GBASE-SR 10GBASE-LR Auto Negotiate (Default) Full Duplex Fibre-based 99.90%: Single uplink (fibre-based access) 99.98%: Fully redundant 3 pair (fibre-based access). The ENNI pair can either be co-located or geographically diverse 4 FRAME FORMATS IEEE Std 802.1ad (Ethertype 0x88A8) or IEEE Std 802.1Q (Etherytype 0x8100) ENNI MTU SIZE 5 ENNI SERVICE MULTIPLEXING Jumbo: 9004 bytes Yes, for both Access EPL and Access EVPL (i.e. a single S-VLAN ID is mapped to the OVC at the ENNI) 1. The MEF-defined E-Line service Type (EVPL) is also supported on the EA product. E-Line services are described in a separate data sheet at https://www.telstrawholesale.com.au/products/data/ethernet-access.html 2. Actual speeds achieved are dependent on a range of factors described in the TSIS documents, including (but not limited) to distance from exchanges for accesses which are not on Telstra fibre. 3. Fully redundant (FR) means that there is a second NTU that is dual-homed to the Layer 2 Edge of the pseudowire/ VPLS cloud, with geographically diverse fibre access paths, enabling flexible customer-managed failover at Layer 3. 4. Business rules apply to the locations of a fully redundant pair of ENNIs. 5. The MTU at the ENNI cannot be considered in isolation and needs to be cognisant of the tail UNI MTU and physical access (bearer) technology. Page 2

UNI Attributes (Tail End) INTERFACE TYPES INTERFACE MODE Telstra Fibre Access 10Base-T 10GBASE-SR 10GBASE-LR Auto Negotiate (Default) Full Duplex Half Duplex Telstra Copper Access 10Base-T NBN Access ACCESS TYPES UNI ACCESS AVAILABILITY TARGET UNI MTU SIZE UNI SHUT DOWN UNI SERVICE MULTIPLEXING CE-VLAN ID (C-VID) BUNDLING Telstra Fibre-based Telstra Copper-based: Premium CoS (1:1) only. Access-EPL only 6 NBN: FTTP, FTTN. FTTB: Premium CoS (1:1) only. Access-EPL only 99.70%: Single uplink (NBN Access) 99.80%: Single uplink (Telstra copper accesses) 99.90%: Single uplink (Telstra fibre accesses) 99.98%: Fully redundant uplink (Telstra fibre accesses) 7 Telstra Fibre accesses: 1596 bytes (standard) 9000 bytes (jumbo) Telstra Copper Accesses: 1522 bytes NBN Accesses: 1522 bytes Disabled For Access EVPL only ( 1 OVC associated with the UNI and based on CE-VLAN ID) Access EPL: All-to-one (All 8 C-VIDs mapped to one OVC at the UNI) Access EVPL: One-to-one: One C-VID mapped to one OVC at the UNI Many-to-one: >1 C-VIDs mapped to one OVC at the UNI (Telstra fibre accesses only) 6. On Telstra copper accesses, only untagged frames are permitted to ingress the UNI. 7. Fully Redundant tail UNIs cannot be geo-diverse nor copper-based nor NBN-based. 8. Including untagged frames. Page 3

OVC Attributes AVAILABLE CLASSES OF SERVICE CLASS OF SERVICE OPERATION OVC FRAME MAPPING Expedited (1:1 CIR:PIR): Short queues and strictly enforced rates, optimised for small frame sizes and low-jitter interactive unidirectional applications, like VoIP and videoconferencing. Not available over Telstra copper accesses or over NBN accesses. Priority (1:1 CIR:PIR): Medium queues with reliable delivery even if delayed. Used for selected real time applications like SQL database queries and unidirectional streaming video. Not available over Telstra copper accesses or over NBN accesses. Premium (1:1 CIR:PIR): Small queues with low discard preference, used for key business applications like email and large file transfers. This is the only class of service available over Telstra copper accesses and over NBN accesses. Standard (0:1 CIR:PIR): Deep queues with higher discard preference, used for best effort applications like web browsing. Not available over Telstra copper or over NBN accesses. Single CoS: Any one of the four available CoS can be used within the OVC (subject to the access type as above) Multi-CoS: Up to four CoS are concurrently supported within the same OVC. (Only supported on Telstra Fibre Accesses) At the ENNI end-point, frames are mapped to the OVC using the S-Tag VLAN ID. At the UNI endpoint: Single-CoS: Frames are C-VID mapped to the OVC irrespective of customer CoS marking Multi-CoS: Frames can be either C-tag mapped (C-VID and PCP) or DSCP-mapped Class of Service Frame Loss Ratio Average One-way Frame Delay 0-161km 162-1609km 1610-16093km Average Frame Delay Variation TARGET NETWORK PERFORMANCE OBJECTIVES, (ENNI-TO-UNI) Expedited <0.01% <5.7ms <14.5ms <37.5ms <1ms Priority <0.01% <10ms <20ms <43ms Not Specified Premium <0.1% Not Specified Not Specified Standard Best Effort BANDWIDTH PROFILE RATES9 Access EPL: For single-cos OVC: Per UNI and per ENNI.OVC For multi-cos OVC: Per UNI.CoS and per ENNI.OVC.CoS Access EVPL: For single-cos OVC: Per UNI.OVC and per ENNI.OVC For multi-cos OVC: Per UNI.OVC.CoS and per ENNI.OVC.CoS 9. Bandwidth Profiles are a method of characterising Service Frames for the purpose of rate enforcement or policing. Incorrectly shaped traffic ingressing a UNI or ENNI towards Telstra will be policed accordingly. The policers are agnostic to any layer-2 marking for single CoS services so will discard traffic on an as they arrive basis. This means non-conforming high-value and low-value traffic have similar probability of being discarded. Page 4

OVC Attributes (continued) COLOUR MODE COLOUR FORWARDING 11 COS MARKING PRESERVATION CE-VLAN ID PRESERVATION LAYER 2 CONTROL PROCESSING S-TAG VLAN ID Colour blind 10 : Expedited: 1:1 (CIR Only) Priority: 1:1 (CIR Only) Premium: 1:1 (CIR Only) Standard: 0:1 (EIR only) Yes Layer 2 priority (802.1p) and Layer 3 priority (DSCP) always preserved end-to-end CE-VLAN IDs are preserved from UNI to ENNI as per relevant MEF specifications Discard for both Access EPL and Access EVPL The following Layer 2 control protocols will be discarded at UNI/ENNI ingress: xstp, LLDP, PAUSE frames, GARP/MRP, LACP/LAMP, CDP, Link OAM, VTP, Port Authentication, UDLD, E-LMI Telstra allocates SVID, or customer indicates preferences 12 Valid S-VID range in both cases is 1001-2999 Known Unicast: Unconditionally supported 13 SERVICE FRAME DELIVERY MAC ADDRESS LIMIT OVC MTU SERVICE OAM PROCESSING RELEVANT SPECIFICATIONS MEF CERTIFICATION Unknown Unicast: Conditionally Supported 14 Broadcast: Conditionally Supported 14 Multicast: Conditionally Supported 14 50 (Enforced in the network) Fibre accesses: 1600 bytes (default) 9004 bytes (requires approval) Copper Accesses: 1522 bytes NBN Accesses: 1526 bytes IEEE 802.1ag CFM is used for internal operational and fault sectionalisation purposes. Customer Service OAM frames with MD-Level = 5, 6 or 7 will be transparently passed at the UNI and ENNI. MEF 33, MEF 10.2, MEF 23, IEEE802.1ad E-Access Services on Telstra fibre accesses 15 are designed to be compliant with MEF 33, but are not yet certified 10. A colour-blind profile is one where the ingress OVC policer at the UNI ignores any existing colour indication that the service frame is already conformant to CIR (green) or EIR (yellow). 11. Colour Forwarding describes the relationship between the colour on an ingress frame into the Operator (Telstra) Network and the colour of the resulting egress ENNI Frame. When Colour Forwarding is Yes, the OVC cannot promote a frame from Yellow to Green. 12. Customer preferences may not be allocable on shared infrastructure, in which case Telstra will unilaterally allocate an available S-VID. 13. Subject to the CoS performance objectives. 14. Where CoS = Premium and the ENNI Access Topology is fully redundant, broadcast, unknown-unicast, and multicast frames are not transparently passed. Also, broadcast and multicast frames are not supported on Copper Accesses. Refer to TSIS. 15. There is no intent to MEF-certify services on copper accesses or on NBN Accesses. The contents of this document are subject to change with 20 Business Days notice. Telstra has made every effort to ensure the accuracy and completeness of the information in this technical specification, but Telstra does not make any warranties as to the accuracy or completeness of this information. This publication has been prepared and written by Telstra Corporation Limited (ABN 33 051 775 556), and is copyright. Other than for the purposes of and subject to the conditions prescribed under the Copyright Act, no part of it may in any form or by any means (electronic, mechanical, microcopying, photocopying, recording or otherwise) be reproduced, stored in a retrieval system or transmitted without prior written permission from the document controller. Product or company names are trademarks or registered trademarks of their respective holders. and are trade marks and registered trade marks of Telstra Corporation Limited, ABN 33 051 775 556. W009 DEC17 Page 5