Best Practices in Rapid Deployment of PI Infrastructure and Integration with OEM Supplied SCADA Systems

Similar documents
Telecommunications and Internet Access By Schools & School Districts

DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT. [Docket No. FR-6090-N-01]

CostQuest Associates, Inc.

Panelists. Patrick Michael. Darryl M. Bloodworth. Michael J. Zylstra. James C. Green

Ocean Express Procedure: Quote and Bind Renewal Cargo

A New Method of Using Polytomous Independent Variables with Many Levels for the Binary Outcome of Big Data Analysis

Figure 1 Map of US Coast Guard Districts... 2 Figure 2 CGD Zip File Size... 3 Figure 3 NOAA Zip File Size By State...

Distracted Driving- A Review of Relevant Research and Latest Findings

State IT in Tough Times: Strategies and Trends for Cost Control and Efficiency

NSA s Centers of Academic Excellence in Cyber Security

Accommodating Broadband Infrastructure on Highway Rights-of-Way. Broadband Technology Opportunities Program (BTOP)

2018 NSP Student Leader Contact Form

Global Forum 2007 Venice

IT Modernization in State Government Drivers, Challenges and Successes. Bo Reese State Chief Information Officer, Oklahoma NASCIO President

The Lincoln National Life Insurance Company Universal Life Portfolio

Tina Ladabouche. GenCyber Program Manager

B.2 Measures of Central Tendency and Dispersion

MAKING MONEY FROM YOUR UN-USED CALLS. Connecting People Already on the Phone with Political Polls and Research Surveys. Scott Richards CEO

Moonv6 Update NANOG 34

2018 Supply Cheat Sheet MA/PDP/MAPD

Post Graduation Survey Results 2015 College of Engineering Information Networking Institute INFORMATION NETWORKING Master of Science

Fall 2007, Final Exam, Data Structures and Algorithms

State HIE Strategic and Operational Plan Emerging Models. February 16, 2011

Department of Business and Information Technology College of Applied Science and Technology The University of Akron

Presented on July 24, 2018

2015 DISTRACTED DRIVING ENFORCEMENT APRIL 10-15, 2015

Team Members. When viewing this job aid electronically, click within the Contents to advance to desired page. Introduction... 2

Direct to Controller Integration Using OPC. Senior SCADA Engineer

CSE 781 Data Base Management Systems, Summer 09 ORACLE PROJECT

Contact Center Compliance Webinar Bringing you the ANSWERS you need about compliance in your call center.

THE LINEAR PROBABILITY MODEL: USING LEAST SQUARES TO ESTIMATE A REGRESSION EQUATION WITH A DICHOTOMOUS DEPENDENT VARIABLE

AASHTO s National Transportation Product Evaluation Program

PI Software Usage. Scott Minter, Director, IT Mitsubishi Power Systems Americas, Inc. Copyright 2010, OSIsoft LLC. All rights reserved.

Silicosis Prevalence Among Medicare Beneficiaries,

Charter EZPort User Guide

The Outlook for U.S. Manufacturing

MERGING DATAFRAMES WITH PANDAS. Appending & concatenating Series

DSC 201: Data Analysis & Visualization

Presentation to NANC. January 22, 2003

ACCESS PROCESS FOR CENTRAL OFFICE ACCESS

Expanding Transmission Capacity: Options and Implications. What role does renewable energy play in driving transmission expansion?

Prizm. manufactured by. White s Electronics, Inc Pleasant Valley Road Sweet Home, OR USA. Visit our site on the World Wide Web

A Capabilities Presentation

Amy Schick NHTSA, Occupant Protection Division April 7, 2011

DTFH61-13-C Addressing Challenges for Automation in Highway Construction

Strengthening connections today, while building for tomorrow. Wireless broadband, small cells and 5G

Sideseadmed (IRT0040) loeng 4/2012. Avo

Presentation Outline. Effective Survey Sampling of Rare Subgroups Probability-Based Sampling Using Split-Frames with Listed Households

Name: Business Name: Business Address: Street Address. Business Address: City ST Zip Code. Home Address: Street Address

PulseNet Updates: Transitioning to WGS for Reference Testing and Surveillance

Touch Input. CSE 510 Christian Holz Microsoft Research February 11, 2016

Empowering Operations with the PI System

Medium voltage Marketing contacts

CMPE 180A Data Structures and Algorithms in C++ Spring 2018

2013 Product Catalog. Quality, affordable tax preparation solutions for professionals Preparer s 1040 Bundle... $579

CIS 467/602-01: Data Visualization

Geographic Accuracy of Cell Phone RDD Sample Selected by Area Code versus Wire Center

National Continuity Programs

Selling Compellent Hardware: Controllers, Drives, Switches and HBAs Chad Thibodeau

Steve Stark Sales Executive Newcastle

GATS Subscriber Group Meeting Conference Call. May 23, 2013

What Did You Learn? Key Terms. Key Concepts. 68 Chapter P Prerequisites

Homework Assignment #5

Jurisdictional Guidelines for Accepting a UCC Record Presented for Filing 2010 Amendments & the 2011 IACA Forms

ASR Contact and Escalation Lists

DESCRIPTION OF GLOBAL PLANS

Non-Revenue Water Management as Effective Utility Management. Steve Cavanaugh, P.E.

Panasonic Certification Training January 21-25, 2019

Paralleling Topologies and Uptime Institute Tier Ratings

Increase uptime with a faster, more reliable, connection

SmartECR Business Value Through Real-Time Data

Configuring Oracle GoldenGate OGG 11gR2 local integrated capture and using OGG for mapping and transformations

Real-time Data Infrastructure Applied to the Monitoring of Renewables Assets

On All Forms. Financing Statement (Form UCC1) Statutory, MARS or Other Regulatory Authority to Deviate

Illinois Institute of Technology Smart Grid Lab Partnership. Information Deck 7/11/2014

Free or Reduced Air from Select Gateways for 1st & 2nd guest on reservation

Development and Maintenance of the Electronic Reference Library

Awards Made for Solicitation

Elevation Data Acquisition Update

Azure App Service. Jorge D. Wong Technical Account Manager Microsoft Azure. Ingram Micro Inc.

Using a Probabilistic Model to Assist Merging of Large-scale Administrative Records

Data Visualization (CIS/DSC 468)

STATE DATA BREACH NOTIFICATION LAWS OVERVIEW OF REQUIREMENTS FOR RESPONDING TO A DATA BREACH UPDATED JUNE 2017

How to Make an Impressive Map of the United States with SAS/Graph for Beginners Sharon Avrunin-Becker, Westat, Rockville, MD

Windows 10 Business. Jeff Fabin Senior Microsoft Cloud Specialist. Ingram Micro Inc.

What's New with PI Data Access 2010

Welcome to the Comcast Business SmartOffice Video Monitoring Solution

Be sure to fax AGA a copy of every application you submitted direct along with the fax confirmation page to ensure you receive your commission!

ARE WE HEADED INTO A RECESSION?

Recovery Auditor for CMS

2013 Certification Program Accomplishments

The Altice Business. Carrier Advantage

MOVR. Mobile Overview Report January March The first step in a great mobile experience

Appriss Health Information Solutions. NARxCheck/Gateway Overview June 2016 Provided by Clay Rogers

The Power of Data: Thriving in a World of Change

Multifactor Authentication in Higher Education Tuesday, December 6, p.m. ET

OPERATOR CERTIFICATION

Theme: Transforming HSE Culture for a Resilient Future

Real World Algorithms: A Beginners Guide Errata to the First Printing

Introducing OSIsoft. Presented by Zsolt Oros, Regional Manager DACH & EE

Transcription:

Best Practices in Rapid Deployment of PI Infrastructure and Integration with OEM Supplied SCADA Systems Kevin Schroeder & Mike Liska

OVERVIEW Company Overview Data Background/History Challenges Solutions Benefits & Results SmartSignal Lessons Learned Next Steps Questions

ABOUT INVENERGY LLC Founded in 2001 Based in Chicago, IL Independent Power Producer Wind Largest privately owned wind developer/owner/operator in the U.S.A. 16 Operating Sites 1610 MW Several sites under construction and in development Natural Gas 5 Operating Sites 2210 MW Solar Several projects in various stages of development

Invenergy Wind Projects Willow Creek, OR Nominal Capacity 72.0 Full Willow Capacity Creek, COD OR 2009 Ashtabula, ND Nominal Capacity 48.0 Full Capacity COD 2009 Wolverine Raleigh, Canada Creek, ID Nominal Capacity 64.5 78 Full Capacity COD 2006 2010 Wolverine Vantage, Creek, WA ID Nominal Capacity 64.5 90 Full Capacity COD 2006 2010 Wolverine Creek, ID Nominal Capacity 64.5 Full Capacity COD 2006 Spring Canyon, CO Nominal Capacity 60.0 Full Capacity COD 2006 Invenergy Owned & Operated Projects Invenergy Build/Transfer Projects CA OR WA NV Camp Springs I, TX Nominal Capacity 130.5 Full Capacity COD 2007 Camp Springs II, TX Nominal Capacity 120.0 Full Capacity COD 2008 ID Judith Gap, MT Nominal Capacity 135.0 Full Capacity COD 2006 AZ UT MT WY CO NM McAdoo Wind Energy, McAdoo, TX TX ND SD NE KS TX Nominal Capacity 150.0 Full Capacity COD 2008 OK MN IA MO AR Forward Energy, WI Nominal Capacity 129.0 Full Capacity COD 2008 LA WI IL MS IN MI TN AL Victory, IA KY OH GA PA NJ MD DE WV VA SC NC FL Nominal Capacity 99.0 Full Capacity COD 2007 Grand Ridge, I, IL Nominal Capacity 99.0 Full Capacity COD 2008 ME VT NH NY MA CT RI Sheldon, NY Buffalo Mountain, TN Nominal Capacity 27.0 Full Capacity COD 2004 Wolverine Beech Ridge, Creek, WV ID Nominal Capacity 64.5 99 Full Capacity COD 2006 2010 Nominal Capacity 112.5 Full Capacity COD 2009 Grand Wolverine Ridge Creek, II - IV, ID IL Nominal Capacity 64.5 111 Full Capacity COD 2006 2009 Tymien /Szczecin, Poland Tymien, Poland Nominal Capacity 50.0 Full Capacity COD 2006 Stanton, Wind TX Energy, TX Nominal Capacity 120.0 Full Capacity COD 2008 Turkey Track, TX Nominal Capacity 169.5 Full Capacity COD 2008 Centennial, OK Nominal Capacity 120.0 Full Capacity COD 2007

BACKGROUND Early wind farms had unique challenges Basic SCADA tools were inadequate for trending/reporting data No standard 3 rd party interface Custom communication solutions required for data transfers to 3 rd parties (Markets, Utility Off-takers, Forecasting Firms) Small fleet size No need for ad hoc analysis Only executive summary information needed Tasked one vendor with creating tool Data Access Data Communication with 3 rd Parties

INDUSTRY EVOLVED Quick Growth in 2007-2009 Concern about long-term viability of original vendor OEM SCADA Systems Improved 3 rd Party Interface Ad hoc analysis needed System flexibility needed

DECISION CRITERIA General Ability to connect to multiple data sources Established technical support Screen design flexibility Custom calculations Scalable framework Large customer base Extensive use in power industry Familiar tool to existing employees

DECISION CRITERIA Business Drivers Automate reporting Creation of new metrics/kpi s Improve performance monitoring

SOLUTION OSIsoft PI Data Historian Enterprise Agreement Why? Limited internal resources Need for interface monitoring for system/data reliability Need for many tags Unlimited licensing of client tools and interfaces

INSTALLATION PLAN Design 2 months Key Work Items Design network architecture Order & configure hardware Create deployment schedule Define data sources, tag naming convention, etc Deploy 2-4 months Installation of first site Remote installation of all other sites Create basic screens Usage Training of key people Create additional screens, calculations, reports, etc

PI SYSTEM ARCHITECTURE Architecture Goals Robust Cost effective Production Environment Wind Farm 1 PI server per wind farm 2 interface servers per wind farm Corporate 1 PI server 1 Portal Server 1 Special Purpose Server (Bomgar, ACE, AF Notifications, PI Agent, etc ) Development Environment Located in the corporate office 1 Server, multiple interfaces

PI SYSTEM ARCHITECTURE PRODUCTION

PI SYSTEM ARCHITECTURE DEVELOPMENT

PI SYSTEM ARCHITECTURE Current Data Sources Wind turbines OPC Interface Real Time Data RDBMS Interface 10 minute averages Substation RTU DNP3 Interface Hydran (GSU Fault Gas & Moisture Monitor) DNP3 Interface

OSIsoft SOFTWARE AND SERVICES USED Field Services Enterprise Project Manager (EPM) Network Operation Center(NOC) Center Of Excellence (COE) Architecture Guidance Recommended Best Practices Value Realization Plan (VRP)

BENEFITS & RESULTS Storage & utilization of multiple data sources Ad hoc trending & analysis Flexibility Visibility Scalability One version of the truth Compliance

ONLINE PORTAL

ONLINE PORTAL

ONLINE PORTAL

ONLINE PORTAL

ONLINE PORTAL

PROCESSBOOK

PROCESSBOOK

DATALINK

SMARTSIGNAL PI enabled us to quickly deploy SmartSignal, which detects, diagnoses, and prioritizes impending equipment and process failures Wind farms pose different issues in terms of monitoring and managing Pilot Project Forward Wind Farm, Summer 09 Fleet Implementation 982 Wind Turbines, 13 Sites December 09 March 10 Project goals Better utilize existing SCADA Data Find low-level issues like failed sensors Predict major items like generator and gearbox failures Spot decreases in efficiency On-going work between Invenergy and SmartSignal

SMARTSIGNAL

SMARTSIGNAL Actual Model Alerts Incidents

LESSONS LEARNED What was successful? Senior management support on purchase Quick deployment OSIsoft EA and EPM 8 sites/ 27 machines in 2 months Data visibility from corporate office Built a platform for future reporting/analysis Gained extensive understanding of WTG SCADA

LESSONS LEARNED What would we do different? Have a dedicated PI team and/or admin but train many people on the tools Engage executives on report and screen requirements early on Create a development environment early on

LESSONS LEARNED The most important lesson data source quality and reliability is key. It is the foundation. Screens and reports are of low value if data quality and reliability is not high.

NEXT STEPS Increase data source system reliability More training Expand user base Corporate Site Personnel Remote Operations Control Center (ROCC) Automate reporting Integrate other data sources Market Data Substation Data Revenue Meters Drive train Condition Monitoring

NEXT STEPS Utilize online portal Setup PI Notifications Develop KPI s Continue to Standardize Tag Configuration Module Database/AF Software Versions, etc ) Improve & Expand Communication with 3 rd Parties using PI

Thank you Copyright 2010 OSIsoft, LLC., 777 Davis St., San Leandro, CA 94577