OptiCom Adapter for HD Flex Cassettes

Similar documents
HD Flex Zero RU Cassette Holder and Bracket

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

The Drivers Behind High-Density Systems

2 visit

ASSEMBLY INSTRUCTIONS for 16 WAY GT MIXED 150/280 SEALED CONNECTION SYSTEM

SYSTIMAX 360 ipatch 96F LC Upgrade Kit

Internal tray pulls out towards the user, providing room to manage the fiber cable behind the fiber adapter panels or cassettes.

High Density PEACOC v. 3.0 Fiber Patch Panel& FleT

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

AP-120 Series AP Mounting Kit

Replacing the SATA PCI Controller Card

TDM To MiniMech conversion ProceDure

DATASHEET REV.1.0 Data center System. Datasheet. 2RU Slide-Out Fiber Enclosure Unloaded #51610 FHD-2UFCE. Description. Application

CONTENTS. 1. Motherboard installation Install 5¼ and 3½ drives Install PCI components Case fan setup...5

QuickNet Harness Cable Assemblies Solution Guide for Switching Applications

Field-Replaceable Units

A-MOD DESKTOP OWNER S MANUAL

Ultraloq UL3 Series Fingerprint and Touchscreen Smart Lock

Replacing an Advanced Power and Cooling (APC) Unit

Central Processing Unit (CPU) Replacement

F2A (M527) F2A (M506n/dn) F2A (M506x)

Rack Mount Interconnect Center (RIC3)

HP EVA4400 M6412 drive enclosure

Port Mapping the Cisco Nexus 9K Switch

INFINIUM TM HD FIBER ENCLOSURE

Removing and Replacing Parts

TDM-100/150 TO NMD-50 CONVERSION PROCEDURES RL5000

FIBRE ENCLOSURES AND SPLICING ACCESSORIES

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade

Installation Guide. Copyright 2005 MSI Computer Corp.

with Fiber Management Bar

TrueNet 1U and 2U Fiber Panel Installation and Cable Routing Instructions

Passive Optical LAN Solution

Installation Guide. English. HP LaserJet 5, 5M and 5N Printer Duplex Printing Accessory (C3920A)

Installation. Setting Up Expression 303

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

M204SMB Surface Mount Box Instructions

120Ra-1 Pentium III Processor Installation Insert

SD Splicing Cassette

Datasheet. Fiber Optic Modular Patch Panel Features

120/220 Magazine HM401

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide

Connecting the EN-4000 to DC Power

Installing the Server into a Rack

Cable Entry Easy and secure duct of loose tube or breakout cables at the rear. Marking Numbered ports guarantee clearly arranged patchpanel marking.

Written By: Walter Galan

Snap Server 4400 Power Supply

QuickNet Harness Cable Assemblies Solution Guide for Switching Applications FBAN-07 March 2014

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

APPLICATION SPECIFICATION

User Guide OMNI 97. For ipad 9.7, ipad Pro 9.7 and ipad Air ADVANCE RELEASE! (Product coming F/W 2017) [ Issued

PC9/P9 CPU Card Replacement

Spec Sheet. OmniReach FTTX Solutions DLX Fiber Optic Connector

Fuser Assembly Removal

Instruction Sheet AND 105 POSITION CONNECTORS FOR 196 WAYS HEADER.

Removing and Replacing Chassis Components

Internal tray pulls out towards the user, providing room to manage the fiber cable behind the fiber adapter panels.

Q2 XBee Handheld Controller Assembly Guide

Contivity Extranet Switch Installing Hardware Options Guide

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Heat Containment System (HCS)

Veritas Appliance Hardware Service Procedure

5000, 7000 Series StorSimple Appliance. Rack Installation Guide

Prepare the Media for Loading

To Our Valued Customers

MPS-Lite. A range of Blank and Connectorized panels in 3 standard widths to fit a 2RU / 3.50 vertical space, plus Adapters to accommodate them.

Oracle <Insert Picture Here>

RMX 2000 MPM to MPM+ Migration Procedure

Opening the Computer 1 Before you open your computer, shut it down by choosing Apple (apple) > Shut Down.

Installation Guide Roll Stand Kit for Philips Avalon FM20/30

DIGITAL Server Rackmount Installation Guide

Veritas Appliance Hardware Service Procedure

System Storage EXP3000 Rack Installation Instructions

Replacement Instructions. Backplane PCA for the HP Router 650

EN-CAUH-B. Enclosure. Assembly Guide

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

SYSTIMAX imvision impower Power Extender Installation

WEASEL N/B MAINTENANCE

Eaton Heat Containment System (HCS) Installation Guide

To connect the AC adapter:

Replacing/Upgrading Mac Pro Processors (Early 2008)

Replacing a 3.5-inch disk drive

JUN 2016 Rev B

Migratable cabling in computer centres for all data rates from Mbit/s to 100Gbit/s (DClink)

2 PIECE BOARD-TO-BOARD

Replacing Preamplifier Circuit Boards

Floor Standing Pedestal

Boxer HD-2X Motorized Pan Tilt Head (P-BXR-HD-2X)

Veritas Appliance Hardware Service Procedure

Rack Installation Instructions

Mac mini Late 2014 Power Supply Replacement

Fiber Optic System MPO Fiber Optic Cassettes FOS. Fiber Optic System

IBM System Storage DCS3860 Quick Start Guide

Tower to Rack and Rack to Tower System Conversion Guide

ROV Response: ROV Response: ROV Response: ROV Response:

FIBRE OPTIC ENCLOSURES SYDNEY MELBOURNE BRISBANE PERTH JCSTECH.COM.AU

GPS-FO7309G3 Vehicle Specific Mounting Bracket for Most Portable GPS

Connect Router to the Network

Two Rack Unit (2RU) Fiber Management Tray (FMT) User Manual

Fibre Enlosures and Splicing

Transcription:

OptiCom Adapter for HD Flex Cassettes Part Number(s): Panduit Corp. 2018 INSTALLATION INSTRUCTIONS 1. REMOVING FROM PACKAGING AND PREPARING FOR INSTALLATION 1.1 Remove from individual carton and bag. Figure 1 displays how will be assembled after being removed from packaging. Thumb Latch Figure 1: removed from packaging 1.2 The is made up of 2 individual components, the rear insert and the front insert. To properly install the, the rear insert must be separated from the front insert. To separate the rear insert, press down on the thumb latch and slide the rear insert away from the front insert. Push here Slide rear insert this direction Figure 2: Showing where the thumb latch is located and how to push down on the latch and direction to slide the rear insert Figure 3: Front and rear insert separated from one another Page 1 of 6

2. INSTALLATION OF INTO PANDUIT 1RU PATCH PANEL (PANDUIT PART NUMBER CFAPPBL1) 2.1 Slide the front insert into the patch panel opening (see figure 4) from the front of the patch panel in the orientation shown. Make sure the plungers attached to the front insert (see figure 4) are pulled back to the "unlocked" position when the is slid into the proper holes. Front Insert Front of CFAPPBL1 Push this direction Patch Panel Opening Figure 4: Front insert oriented and in process of being placed into proper patch panel opening with plungers in "unlocked" position Plunger pulled back "Unlocked" position: back portion not flared out 2.2 Lock the front insert in place by pressing the plungers into the "locked" position once plungers have been inserted into the necessary holes in the patch panel. Front of CFAPPBL1 Figure 5: front insert installed into proper patch panel holes with plungers pushed into "locked" position Detail showing plunger pushed into "locked" position Page 2 of 6

2.3 Slide the rear insert of the onto the front insert of the in the orientation shown until an audible "click" is heard as the thumb latch on the front insert snaps into position when interacting with the square cutout on the rear insert. Square Cutout Thumb Latch Figure 6: rear insert positioned to be slid onto front insert Slide U-channels on rear insert over front insert Figure 7: rear insert beginning to slide onto front insert U-channels engaged CLICK! Square cutout engaged with thumb latch Figure 8: rear insert square cutout engaged with front insert thumb latch, seated into final position Page 3 of 6

3. INSTALLATION OF HD FLEX CASSETTES/MPO FAPS INTO Note: The can accept (2) HD Flex Cassettes which have up to 6 ports in front of the cassette. Four port and twelve port HD Flex Cassettes are not compatible with the. HD Flex MPO to LC Cassettes, HD Flex MPO FAPs, HD Flex LC FAPs, HD Flex LC Splice Cassettes, HD Flex 4:1 Conversion Cassettes, and HD Dark Fiber Conversion Cassettes are all compatible to be used with. HD Flex MPO to LC Cassette HD Flex LC Splice and LC FAP Reference Installation Instruction FS117 HD Flex MPO FAP Figure 9: Compatible HD Flex Cassette Modules to be used with HD Flex 4:1 Conversion Cassette HD Flex Dark Fiber Conversion Cassette 3.1 Slide the first cassette module into the lower cassette position in the orientation shown. LC Splice Cassettes are shown in the below pictures. (Panduit part number: FHS**N-12-**N, FHS**-12-**P, FHS**-12-**R) Windows Windows Front Slots Cassette Fins Front Slots Cassette Fins Cassette Ears Figure 10: Lower cassette oriented to be inserted into Cassette Ears Figure 11: Lower cassette partially installed into Page 4 of 6

Lower cassette fully installed Front Slots Windows Figure 12: For proper installation, HD Flex cassette fins are seated within the front slots located on the rear insert. For proper installation, HD Flex cassette ears are seated in the rear insert windows of the. Cassette Fins Cassette Ears Rear legs may need to be deflected to seat ears correctly 3.2 Slide the second cassette module into the top cassette position, following the same procedure as Step 3.1. Figure 13: Upper cassette oriented to be inserted into Figure 14: Upper cassette partially installed into Page 5 of 6

Figure 15: Upper cassette fully installed into 4. Compatible Patch Panels and Enclosures Shown below is a table of patch panels and enclosures which accept the. The installation steps explained above can be used to place the into the necessary enclosure/patch panel. Part Number CFAPPBL1 CFAPPBL2 FMT1 (WHEN PAIRED WITH CFAPPBL1) FMT2 (WHEN PAIRED WITH CFAPPBL2) FCE1 FCE1U FCE1UA FCE2U FCE4 FCE4U FRME1 FRME1U FRME2 FRME2U FRME3 FRME4 FMD1 FMD2 Note: cannot be used with angled patch panels CFAPPBL1A or CFAPPBL2A. Also cannot be used with angled enclosures FMT1A or FMT2A. For Instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp www.panduit.com Page 6 of 6 E-mail: techsupport@panduit.com Phone: 866-405-6654