ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

Similar documents
ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

ABL8RPS24030 regulated SMPS - 1 or 2-phase V - 24 V - 3 A

ABL8WPS24200 regulated SMPS - 3-phase V AC - 24 V - 20 A

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL7RM24025 regulated SMPS with auto reset - 1 or 2-phase V AC - 24 V A

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ABL1REM24062 regulated SMPS - single phase V input - 24 V output W

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

RM4JA01F current measurement relay RM4-J - range ma V AC

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM35TF V AC

RM4UA33M voltage measurement relay RM4-U - range V V AC

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

7 - Phaseo power supplies and transformers

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

RM4TR31 three-phase network control relay RM4-T - range V

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM4JA31M current measurement relay RM4-J - range ma V AC

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

RM17UB3. Price* : USD

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RM4LA32M liquid level control relay RM4-L V AC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE9RA21MW7 off-delay timing relay s V AC -

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

SR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

XPSMCMDI Input expansion module with screw term

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

RM4TA32 three-phase network control relay RM4-T - range V

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

TM3AI4 module TM3-4 analog inputs

TM3DI16 module TM3-16 inputs

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

TM258LD42DT4L compact base M I/O - 24 V DC

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

TM258LF42DT compact base M I/O - 24 V DC - CANopen

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

TM3TI4 module TM3-4 inputs temperature

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

TM3TI8T module TM3-8 inputs temperature

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

TM3SAC5RG SAFETY MODULE FOR PLC TM2xx, 1 FUNCTION, CAT3, SPRING TERMINALS

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

TM3DI16G module TM3-16 inputs spring

Transcription:

Characteristics regulated SMPS - 1 or 2-phase - 100..240 V AC - 24 V - 5 A Main Range of product Product or component type Power supply type Input voltage Output voltage Rated power in W Input protection type Power supply output current Output protection type Ambient air temperature for operation Complementary Input voltage limits Network frequency Inrush current Oct 10, 2018 Phaseo Power supply Regulated switch mode 100...240 V AC phase to phase, terminal(s): L1-L2 100...240 V AC single phase, terminal(s): N-L1 110...220 V DC 24 V DC 120 W Integrated fuse (not interchangeable) 5 A Against overload, protection technology: 1.1 x In Against overvoltage, protection technology: tripping if U > 1.5 x Un Against short-circuits, protection technology: automatic reset Against undervoltage, protection technology: tripping if U < 0.8 x Un 0...50 C without 50...60 C with 100...250 V 85...264 V 47...63 Hz 30 A Cos phi 0.65 Efficiency 85 % Output voltage limits Power dissipation in W Current consumption 100...120 % adjustable 21.2 W 1.2 A at 240 V 1.9 A at 100 V Line and load regulation +/- 3 % Holding time Connections - terminals >= 10 ms at 100 V >= 10 ms at 240 V Screw type terminals for input connection, connection capacity: 2 x 0.14...2 x 2.5 mm² AWG 26...AWG 14 Screw type terminals for output connection, connection capacity: 4 x 0.14...4 x 2.5 mm² AWG 26...AWG 14 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Marking Mounting support Operating position Operating altitude Output coupling Screw type terminals for input ground connection, connection capacity: 1 x 0.14...1 x 2.5 mm² AWG 26...AWG 14 Screw type terminals for output ground connection, connection capacity: 2 x 0.14...2 x 2.5 mm² AWG 26...AWG 14 CE 35 x 15 mm symmetrical DIN rail 35 x 7.5 mm symmetrical DIN rail 75 x 7.5 mm symmetrical DIN rail Vertical 2000 m Parallel Series Name of test Conducted/Radiated emissions conforming to EN 55011 Conducted/Radiated emissions conforming to EN 55022 Class B Electrostatic discharges conforming to EN/IEC 61000-4-2 Emission conforming to EN 50081-1 Induced electromagnetic field conforming to EN/IEC 61000-4-6 Primary outage conforming to IEC 61000-4-11 Radiated electromagnetic field conforming to EN/IEC 61000-4-3 Rapid transient conforming to IEC 61000-4-4 Surge conforming to EN/IEC 61000-4-5 Status LED Depth Height Width Product weight 1 LED green for output voltage 1 LED orange for input voltage 120 mm 120 mm 54 mm 1 kg Environment Product certifications CCSAus UL EAC KC Standards UL 508 CSA C22.2 No 60950-1 Environmental characteristic EMC conforming to EN 50081-1 EMC conforming to EN 50082-2 EMC conforming to EN/IEC 61000-6-2 Safety conforming to EN/IEC 60950 Safety conforming to SELV IP degree of protection IP20 conforming to EN/IEC 60529 Ambient air temperature for storage -25...70 C Relative humidity 0...95 % without condensation or dripping water Overvoltage category Class I conforming to VDE 0106-1 Dielectric strength MTBF reliability Between input and ground Between output and ground Between input and output Between outputs 104640 H at 110 V AC with MIL-HDBK-217F calculation method 105777 H at 220 V AC with MIL-HDBK-217F calculation method Contractual warranty Warranty period 18 months 18 months 2

Dimensions Drawings Regulated Switch Mode Power Supply Dimensions and Mounting Mounting on 35 mm/1.37 in. or 75 mm/2.95 in. Rail 3

Connections and Schema Regulated Switch Mode Power Supply Internal Wiring Diagram 4

Connections and Schema Regulated Switch Mode Power Supplies Series or Parallel Connection Series Connection (1) Two Shottky diodes Imin = power supply In and Vmin = 50 V Parallel Connection Family Series Parallel ABL 8REM/7RP 2 products max. 2 products max. NOTE: Series or parallel connection is only recommended for products with identical references. 5

Performance Curves Regulated Switch Mode Power Supplies Derating The ambient temperature is a determining factor that limits the power an electronic power supply can deliver continuously. If the temperature around the electronic components is too high, their life will be significantly reduced. The nominal ambient temperature for the Optimum range of Phaseo power supplies is 50 C. Above this temperature, derating is necessary up to a maximum temperature of 60 C. The graph below shows the power as a percentage of the nominal power that the power supply can deliver continuously, depending on the ambient temperature. X Maximum operating temperature ( C) (1) ABL 8REM, ABL 7RP mounted vertically Derating should be considered in extreme operating conditions: Intensive operation (output current permanently close to the nominal current, combined with a high ambient temperature) Output voltage set above 24 Vdc (to compensate for line voltage drops, for example) Parallel connection to increase the total power 6

Performance Curves Regulated Switch Mode Power Supply Load Limit 7