Model XAV2 & XAV2-LED System Installation

Similar documents
EZCommunicator 4 Wire Navigator APS System Installation Manual

Tracer VM Bluetooth Interface

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

APPROVED 07/11/16 EZCommunicator 2 Wire Navigator APS System Installation Manual

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR ACCESSIBLE PEDESTRIAN SIGNAL SYSTEM

MS-4000: ShootingStar Reader

Arrakis Systems 6604 Powell Street / Loveland, Colorado 80538

4 Wire Navigator Accessible Pedestrian Signal Operation Manual

V-9939C MICROPHONE ADAPTER

Rev Cutler-Hammer Smart Breaker Panel Control Manual

ABM International, Inc. Lightning Stitch Checklist 9/13/2013

MS-5000: MiniStar Reader

Trademark Generation II Series Intercom System Installation and Operation Reference Guide

CP150B Vandal & Weather Resistant Keypad Security Systems

MS-3000 MicroStar Reader

MS-7000: SuperStar Reader

inavigator 3 System Manual

Lightning Stitch Assembly

Model: CAM430MV Wired Multi-View Camera with License Plate / Rear Surface Mount Installation Manual Features

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

DC Outdoor Power Supply/Chargers

Connecting the THP-700RTS to a Telephone and Radio Console - Summary. DynaMetric. Made in USA THP-700RTS

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

poly-planar Marine Audio System

508 SERIES MICROPHONE STATIONS

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

MAXIMA + Series ROTARY LEVEL CONTROL

PS/IO Circuit Board Retrofit

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

inavigator 2 Wire System Manual

INSTRUCTION MANUAL A141 High Level Audible Warning System

Blue Point Engineering

5000 Series Audio Matrix

EP/2 Installation Instructions

V-9939B MICROPHONE ADAPTER

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

R-10/16 Module Pinout Connections

Installing a Power over Ethernet injector

Allen-Bradley PLCs. 100 Programmable Controller Processor Unit -Catalog Nos LPI01, -LP102, -LP103, -LP104 SLC TM. The Unit

Infosystem Remote Touchscreen Installation Instructions

Advanced Visual Solutions Ltd

Installation Instructions & User Manual

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

inavigator 2 Wire System Manual

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

APPROVED. EZCommunicator 2 Wire Navigator APS System Installation Manual

inavigator 2 Wire System Manual

232iLM Keypad Installation and Programming Instructions

C-POWER AC AUTOMATIC CONTROL

PO Box 409 Hanover, MD TEL (410)

Installation Instructions

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Installation Instructions

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

APPROVED EZCommunicator 2 Wire Navigator APS System Operation Manual

GF92 Installation, Operation and Troubleshooting Guide

LC3 LIGHTING CONTROLLER OPERATIONS & MAINTENANCE MANUAL 2013 Dec

Rev CH Breaker Gateway Installation and Operation Manual

Expandable Power Systems

BA/BS4S Temperature Sensor Installation & Operating Instructions

LED Maintenance Instructions

Operating Manual AMIS60, 60w Mixer Amplifier & AMIS120, 120w Mixer Amplifier

MAXIMA+ Series Rotary Level Indicator

INTERCOM SYSTEM Model ICA900

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

LPG STM 94442A User s Manual

inavigator 3 System Manual

OPLC Installation Guide

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

inavigator 2 Wire System Manual

Copy Machine Reader. Installation and Setup Guide

ROAM DCM127-NX1 Dimming Control Module. Requirements & Installation Guide

MAXIMA + Series ROTARY LEVEL CONTROL

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

HI SEC Integrated Systems

Smart Monitor User Manual

232iLM Keypad Installation & Programming Instructions

FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

HomeWorks Remote Power Feed-Through Panels

Button Code Kit. Assembly Instructions and User Guide. Single Button Code Entry System

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Microsystems. SCI-6 Sound Card Interface Kit Version 1.09 January 2015

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Installation Notes TII Model 341 Protector


MT400 MOTION CONTROLLER

6222 Two Door Module Technical Operations Manual

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

Product Manual MNX10043 REV A MODEL DSB. Dual Sensor Modular Switch box

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document

Gauge Mount Radio PRIMARY FEATURES. Marine & Powersports Bluetooth Source Units

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

ZC-OH5 TAMPER-RESISTANT INDOOR/OUTDOOR HOUSING INSTRUCTION MANUAL FOR USE WITH GANZ ZC-D5000 SERIES MINIDOME CAMERAS

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

Transcription:

Model XAV2 & XAV2-LED System Installation 10/09/07 This document provides instructions for installing the Polara Push Button Station (PBS) and the XAVCU2 or XAVCU2-DC Control Unit. Mounting the Push Button Stations Use the provided mounting hole diagram on page 7 to drill and tap the pole for the PBS. The maximum recommended distance from the ground to the center of the push button is 39 inches. Less than 39 inches is acceptable. The PBS comes with the button arrow pointing in a certain direction. The button arrow can be made to point left, right, or up, depending on the location of the PBS on the pole. The arrow should always point through the crosswalk. For example, if you stand facing the button and the crosswalk is on your left, the arrow should point to the left. If the crosswalk is directly in front of you, the arrow should point up. If the crosswalk is on the right, the arrow should point to the right. Remove the sign from the PBS by removing the four attachment screws. If the arrow direction is correct, there is no need to open the unit. If the arrow needs to be changed, remove the 6 cover screws and carefully bring the cover to approximately 60º which frees the bottom hinge, then remove the cover. Place the cover on a flat surface with the backside facing you (see the sketch below). To change the arrow direction, loosen the 4 screws holding the diaphragm 1-2 turns each. Press on the front of the button and turn it counter-clockwise until it pops out. Orient the arrow in the desired direction then replace the diaphragm so each tab sits in its pocket with a corner under each screw head. Tighten each screw making sure the diaphragm is not pinched between the screw and cover. The screw head is intended to keep each tab in its pocket. The screw must not bind the tab preventing it from moving freely. Reinstall cover and six screws. Be careful not to drop the cover and break the hinge. Turn while lightly pressing on button from other side to remove. 4 Screws holding diaphragm DOC. 350-020 REV. B22423 7PGS 1

Route the cable into the pole either downward to an access hole, or upward and out the top of the pole. If the XAVCU2 control unit will mount on the same pole, then, route the cable to the XAVCU location. Attach the PBS to the pole using the supplied ¼-20 bolts and washers. Re-attach the sign as shown in the sketch. To XAVCU2 control unit mounted on top of pole. 39 Maximum to ground Additional cable (supplied by installer) to XAVCU2 control unit mounted in light controller box. 2

Mounting the XAVCU2 Control Unit The XAVCU2 is typically installed in the same protective enclosure as the light flashing control system, but if it is mounted on the pole or any other location, it must be in a NEMA 4 or equivalent moisture proof protective box. For mounting within the light flashing control system enclosure, locate a suitable space for the XAVCU2 board inside the same enclosure. The board measures 6.5 x 4.5 and has four mounting holes on 5.4 x 3.9 centers. Drill and attach with four screws. Wiring (Refer to the accompanying wiring diagram) The Model XAV2 system uses 8 conductor cabling between the PBS and control unit. If the PBS and XAVCU2 are mounted on the same pole, then the PBS cable may attach directly to the XAVCU2. Otherwise additional cable is required. Polara recommends a direct burial suitable cable with AWG 18 stranded conductors and matching color coding (Belden 27601A). Polara stocks this cable which can be purchased separately. The 8 conductor cable connects to the 8 terminal blocks along the bottom edge of the XAVCU2. The terminal blocks are labeled with the color of the wire that connects to the block. Each block has two connections which are connected in parallel for easy connection of two PBS units. Strip about 1/4 of insulation off each wire to connect to the terminal block. The functions of the terminal blocks are also marked to aid in troubleshooting so that in case of trouble, you may be able to identify the wires associated with the problem. If additional cable is used, then splicing is necessary. Polara provides 3M Part No. UAL cable splicing connectors for this purpose. These connectors are compatible with the PBS cable and the Belden AWG 18 cable. To make the splice, insert the unstripped ends of the matching color into the connector as far as they will go. Then use pliers to compress the button down approximately flush with the connector body. Splice all 8 wires of matching colors. Note that two of the wires have a black stripe so make sure these are correctly matched. Two connections (4 wires) are required between the XAVCU2 and the crosswalk flashing system. The first is the push button input that triggers the flashing. This wire pair should connect to the BUTT OUT terminals on the XAVCU2. Next is a flashing signal from the flash control. This signal should turn on and off with the flashing lights visible to street traffic. It could be the actual voltage feeding the flashing lights. The voltage may be 10 135 volts, AC or DC. The wire pair should connect to the LTS IN terminals. One wire connects to COM and the other to the terminal best matching the voltage present on the wire (10-35V or over 35V). It is this signal which triggers the audible message from the XAV2 system. DC MODEL If you are installing the XAVCU2-DC, connect a DC source of 10-24 volts to the DC INPUT POS and NEG terminals. If the DC source is two 12 volt batteries in series, connect the XAVCU-DC to only one of those batteries to avoid exceeding 24 volts. Otherwise, connect 115 VAC to the AC INPUT LINE and NEUT terminals. If an earth ground wire is available, connect it to either EARTH terminal. 3

WIRING DIAGRAM 112V AC INPUT 10-24V DC INPUT (Do not exceed 24V. See instructions on page 3.) 4 Two terminals provided for each function to accommodate two buttons.

Operation The XAVCU2 has two LED indicators. The red PWR LED flashes once per second and indicates that the board has operating power and the on-board microcontroller is functioning. The red BUTT LED indicates whenever a PBS button is pressed and activated. MESSAGE REPEAT SELECTI Dip switch positions 1 and 2 are used to select the number of message repeats whenever flashing starts. SW1 SW2 Result 1 Repeat 2 Repeats 3 Repeats Continuous while flashing If any of the message repeats, 1, 2, or 3, is selected, then any button push during the flashing will restart the message count. LOCATE TE SELECTI Dip switch positions 3 and 4 are used to configure the PBS locating tone. SW3 SW4 Result No Locate Tone Locate tone every 2 seconds Locate tone every 3 seconds Locate tone every 4 seconds MESSAGE SELECTI Dip switch position 5 selects the message type. SW5 Result English Language Only English message followed by Spanish message Volume Control The output volume from the XAV2 system is chosen automatically based on the ambient noise level received by the microphone. The volume can self-adjust over a wide range. A microphone sensitivity (MIC SENS) control can increase or decrease the volume change due to a change in ambient noise. MIN and MAX controls are provided for both voice message and locate tone. These adjustments restrict the volume range chosen by the microphone control. The MIN control sets the lower limit for the volume and the MAX control sets the upper limit. If both controls are set the same, or the MAX is set below the MIN, the volume will be fixed. The MAX control takes precedence over the MIN. 5

Troubleshooting Information The following are descriptions of the XAVCU2 terminals to help identify sources of trouble. PWR+ TERMINAL This point should always have a DC voltage present. For the XAVCU2, this voltage should be 13 to 15 volts most of the time. It will typically fluctuate some if the voice message is currently playing. For XAVCU2-DC, the voltage should match the DC INPUT voltage. This voltage is measured between PWR+ and PWR-. PWR- TERMINAL This is the circuit ground for the XAV2 system. BTN TERMINAL Connecting this terminal to ground (PWR-) should cause the BUTT LED to light and cause the BUTT OUT terminals to change to a low resistance state between them. Pressing the PBS button should cause the voltage at the BTN terminal to drop to near zero. LED TERMINAL This is an output from the XAVCU2 to the PBS. It's an open collector type output that connects to ground to turn on the PBS LEDs. This output should turn on the LEDs whenever the voltage is present at the LTS IN input. MUTE TERMINAL This is an output signal which switches the audio amplifier in the PBS between operate and standby modes. It should go to ground whenever a sound is to be played. MIC TERMINAL This is a low voltage signal from the PBS which represents the ambient noise level. It is generally less than 1 volt above ground and can range from 0 to 1.5 volts. It should change as the ambient noise changes. AUD1, AUD2 This is a balanced audio signal which provides the input signal to the audio amplifier. FLSH COM, FLSH1, FLSH2 Output signals for driving external flash relays. These are typically not used, and are intended for special order applications. BUTT OUT Solid state opto-relay contact closure while BUTN terminal is grounded. LTS IN Input from an external flash controller. This signal must be present in order to trigger the voice message and also to flash the PBS LEDs. IMPORTANT! 1. The message will not play without proper inputs from light flashing controller on LTS IN. 2. Check to see that the striped RED/BLK and BLU/BLK and non-striped RED and BLUE wires are not mixed with each other. All wires should be connected to their appropriate matching color. 6

1 4-20 MOUNTING HOLE DIAGRAM FOR PUSH BUTT STATI When printing document in Adobe Acrobat, be sure that "None" is selected in Print Scaling in the printing dialog box to ensure that document is printed to the correct scale. Otherwise, recreate template using dimensions shown. 6.00 3.44 1 4-20 5 8 " MIN Hole for button wires 7