Interfacing with the Biacore instrument

Similar documents
Orifice Flow Meter

GE Healthcare. Biacore Instrument Handbook

EASY-nLC Virtual Instrument for Xcalibur 2.1.x Quick Reference Guide

Sciex QTrap Operational Steps for Trained Personnel

INSTRUMENT HANDBOOK. Biacore 2000

BIAevaluation Software Handbook

Wave User s Guide. Contents

Gen5 & Gen5 Secure User's Guide

Reference Guide for the Value Assignment Web v

Electrophoresis File Run Summary

Validation Sample Set Generator

Getting Good Data with xponent Software for the Luminex MAGPIX, Luminex 100/200, and FLEXMAP 3D Systems

Automating HPLC Analytical Methods Development

Tutorial: FCAP Array Software with BD FACSArray Bioanalyzer

Microplate Systems. Absorbance Microplate Readers 366. Performance Validation and Software Tools 368. Microplate Washer 370

Overview. Experiment Specifications. This tutorial will enable you to

ACQUITY UPLC Systems with 2D Technology Capabilities Guide

ACAS Tutorial. Simple Experiment Loader. Contents:

Enhancing your Lab Workflow with NuGenesis 8 ELN and Empower Waters Corporation 1

Troubleshooting Guide

Wave User Guide XF e Analyzer

Installation Guide for Multidrop Combi with Valve Driver for Polara RS

Using the Chromeleon Summit 2 Tandem Operation Wizard

COBAS INTEGRA 400 plus

LIGHT SOURCE Quartz-iodine lamp 12V-20W.

EASY-nLC Series User Guide for the Xcalibur Data System (Xcalibur version 2.1 or later)

OLI Chemistry Wizard 9.5 User Guide

WHITEPAGES PRO DEEP LINK BUILDER

Issued by: LABORATORY MANAGER Original Date: March 14, 2001 Approved by: Laboratory Director Revision Date: June 6, 2003.

Standard Operating Procedure for the Beckman PA/CE MDQ Electrophoresis System. Last Modified October 19, 2012

June Fairfax County Health Department

3 Starting the chiral HPLC and logging into LC Real Time Analysis.

NEW IMPROVED SCREENING PLATFORM MATERNAL FETAL HEALTH

SPA III Quick Reference Guide for Custom Panels

Xcalibur. QuickQuan. User Guide. XCALI Revision C July For Research Use Only Not for use in Diagnostic Procedures

Standard Operating Procedure for the HPLC-ICP-MS System By Celina Dozier Fall 2017

Crocodile miniworkstation. Your personal ELISA automation

GENESYS ON-BOARD SOFTWARE RELEASE NOTES

Setup for Omnia assays on SpectraMax Paradigm Microplate Detection Platform with SoftMax Pro 6 software

Automating HPLC Analytical Method Development Fusion AE Software Program White Paper

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump

Data Collection Software Release Notes. Real-Time PCR Analysis Software Release Notes. SNP Genotyping Analysis Software Release Notes

OGI-IT (L)IMS. an overview

Spark Holland introduces

FULLY AUTOMATED 2 MICROPLATE ANALYZER

Product Correction Urgent Immediate Action Required

6 th International Conference on Applied Informatics Eger, Hungary, January 27 31, MMA Technology. Robert Tornai

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Luminex Prima

BA-88A Semi-auto Chemistry Analyzer

Report Generator User Guide

Automated Submission for Analysis Processing (ASAP) Operator s Guide Dionex Corporation

The BLR Employee Handbook Builder allows you to create your own customized employee handbook. Benefits include:

CounterTrace. Users manual. Version 1.3.0

Thermo. EASY-nLC User Guide for LC Devices

MiSeqDx Reference Guide

Precision Instruments for Research and Industry. J-KEM Scientific Syringe Pump

Sirius Single Tube Luminometer. Highest Performance Utmost Flexibility

RIDA GENE real-time PCR DNA Assays

Applied Biosystems RapidFinder Software Version 1.0 and SDS Software Version Beta Release 10/05 Release Notes (PN Rev A)

Bio-Rad Laboratories AUTOIMMUNE TESTING. System. PhD. IFA and EIA Instrumentation. One revolutionary platform, two technologies

ATP ELISA. miniworkstation. Microvolume Spectrometer. Microplate Coating. Luciferase. Assays. Microplate Washer. Reader.

Agilent GC/MSD Instructions

BD Accuri C6 with single tube loader protocol. For multiplex assays

Manual HPLC-4 Alliance-UV

PAL Sample Control. Edition Date Version

Data acquisition and analysis of MACSPlex Cytokine Kits using the MACSQuant Analyzer Express Modes in MACSQuantify Software version 2.

Introduction to the HPLC ChemStation and Acquisition

Digital Humidity Probe, HPL1 (#30009)

Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached.

Version 3.0 Quick Reference Guide

Keithley 2100 v1.06 Firmware Release Notes. Contents. General Information. Supported Models. Installation Instructions

eprep Sample Preparation Workstation

Fusion AE LC Method Validation Module. S-Matrix Corporation 1594 Myrtle Avenue Eureka, CA USA Phone: URL:

Getting low-resolution GC-MS data on the JEOL GCMate Introduction

ChromQuest 5.0 Quick Reference Guide

1. What s New in Bio-Plex Manager 6.1

E-Notebook User Guide

Chromatography Software Training Materials. Contents

BD FACSMelody Cell Sorter Quick Reference Guide

Veriti Thermal Cycler

Spark Holland introduces

HID Real-Time PCR Analysis Software

Bulk Creation of Data Acquisition Parameters

ESR-Auto Plus LIS Interfacing Guide

The NGAL Test Application Note for Abbott Architect c8000

Release Notes for Agilent Drivers for Thermo Scientific Chromeleon 7 (Rev. 1.1)

FluoroSELECT Fluorometer User s Manual

For additional information, see these documents on the Breeze 2 software DVD:

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

Table of Contents RURO, Inc. All Rights Reserved

4 plate fully automated ELISA analyzer Reagent system. Open (Human tests predefined) Throughput (max.) Up to 7 plates / run Reaction / reading system

QUALITY OVERALL SUMMARY - CHEMICAL ENTITIES (Applications for Drug Identification Number Submissions) (QOS-CE (DINA))

Roche LightCycler 480

Leveraging ALCOA+ Principles to Establish a Data Lifecycle Approach for the Validation and Remediation of Data Integrity. Bradford Allen Genentech

OEM FRU TECHNICAL WHITE PAPER

Liquid Handling: BioMek 3000; Protocol Plate Washer; SOP Fraction Collector; Description

Quick Guide NC-200. NucleoCounter. to the easiest cell count ever!

Target Drillhole Mapping

MAKE THE CHANGE FOR BETTER NEONATAL SCREENING. Introducing the new AutoDELFIA immunoassay system for newborn screening

Basic CBPro Workflow

Transcription:

Interfacing with the Biacore instrument Different ways of interfacing with the instrument Manual run Wizards Method Builder methods 2 1

Manual Run 3 Application Wizards Guides you through each step in the analysis 4 2

Method Builder Method Builder - Concept Designed for maximum flexibility Built in support for evaluation Integrated assay knowledge 6 3

Method Builder Support Provided Small molecules» Solvent correction» Extra wash procedures Affinity in Solution Buffer change Adaptivity» If Then commands 7 Methods 1(2) Assays are built up step by step in Methods» Possible to save, share and re-use methods 3 approaches to creating methods:» Create Methods from wizards» Start with a Biacore Method» Create your own Method 8 4

Methods 2(2) Pre-defined Biacore Methods» LMW screen» LMW kinetics» Kinetics heterogeneous analyte» Affinity in solution» NTA kinetics» L1 liposome capture 9 Workflow Overview General settings Define method Define run settings and start the run Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Rack Positions Save Method (.method) Save Run (.blr) 10 5

Define Method 1(3) Overview General settings Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Rack Positions Save Method (.method) Save Run (.blr) 11 Define Method 2(3) Assay Steps» Define the purpose of assay components (e.g. start-up, sample, control sample)» Assay steps can be repeated or recurrent» Recurrent for e.g. control samples every 10 th sample Cycle Types» Define the injection sequence for a cycle using commands» Set parameters for each injection» Parameters can be defined as variables Connect Cycle Type to Assay Step 12 6

Define Method 3(3) Overview General settings Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Variable definition In method At run time Some in method, others at run time Rack Positions Save Method (.method) Save Run (.blr) 13 Setup Run Overview General settings Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Define run settings and start the run Rack Positions Save Method (.method) Save Run (.blr) 14 7

More about Method Builder Overview General settings Assay Steps Cycle Types Sample & Assay Setup Verification Setup Run Detection Enter variables Cycle Run List System preparations Create method from Kinetics wizard template Rack Positions 15 Overview Provides a summary of the method (settings cannot be changed here) Left panel shows assay steps Right panel shows settings and cycle type definition for the selected assay step 16 8

General Settings At start: Concentration unit At start: Data collection rate At start: Sample compartment temperature After run: Analysis temperature Detection (single, dual or multi)» Affects which flow paths will be available for each injection command 17 Assay Steps Determines the main structure of the method Steps at the top level are executed in the order given Nested steps (marked with an arrow) are executed within the step they are placed 18 9

Cycle Types Injection parameters are set (contact time, type of injection, etc) Report points may be added or altered Variables may be added or altered For example, one cycle type can include the commands Sample1 and Regeneration1 19 Connect Cycle Type to Assay Step Performed in Assay Steps 20 10

Sample & Assay Setup Determine whether variables are defined in method, at run time, or a mixture of these 21 Verification Checks that the method is correctly and completely defined A method that fails verification can be saved but not run Verification may fail because parameters are missing or the method construction is invalid 22 11

Setup Run - Detection Set the flow path for the detection Only choose flow path consistent with Detection setting for the method 23 Setup Run - Variables Assign values to variables that were not defined in method (for each assay step) 24 12

Setup Run Cycle Run List Complete summary of the cycles in the run 25 Setup Run System Preparations Choose preparation steps to be executed before the run Temperature settings can only be defined in method 26 13

Setup Run Rack Positions Displays the sample and reagent positioning 27 Setup Run Prepare Run Protocol Allows you to enter a run protocol with instructions A general protocol is suggested 28 14

Method Builder - Summary Software tool for user-defined methods» Maximum flexibility» Support features not available in wizards» Built-in evaluation support» Biacore Methods provides user-guidance 29 15