ED40. Development Kit. Quick Start Guide

Similar documents
Mini DB Development Kit

Dolphin TM 6500 Mobile Computer. Quick Start Guide

Dolphin ebase. Communication Cradle for the Dolphin 9700 Mobile Computer. User s Guide

Dolphin 75e. Quick Start Guide. powered by Android E-AN6-EN-QS Rev A 5/16

Dolphin TM 6110 Mobile Computer. Quick Start Guide

Dolphin 99EX. with Windows Embedded Handheld 6.5. Quick Start Guide

CK75. Preliminary Draft, Not for Release. Please Review 2/1/17. Quick Start Guide. with Windows Embedded Handheld 6.5. CK75-W65-EN-QS-01 Rev (a) 2/17

Dolphin CT60. Quick Start Guide. powered by Android 7. CT60-A7-EN-QS Rev B 12/17

Dolphin 70e Black. Quick Start Guide. powered by Android E-AND-QS Rev B 6/13

Skynax. Push Messaging. Integration Guide

Dolphin CN80. Quick Start Guide. powered by Android. CN80-A7-EN-QS Rev A 3/18

Optimus Quick Start Guide. 如要到中国 简体 ) 5100-QS Rev A 8/11

CN75/CN75e NI. Quick Start Guide. with Windows Embedded Handheld 6.5. CN75NI-W65-EN-QS-0 Rev A 5/17

Coletor de Dados Honeywell Dolphin 60s

Skynax. Remote Assist Console. User Guide

User Manual. August 2008 Revision 1.0. SKH300 ibutton Reader Configuration Utility

Computador Honeywell Thor MV1

Dell OptiPlex All-in-One. Stand Installation Guide

Dolphin CT50. Quick Start Guide. with Windows 10 IoT Mobile Enterprise. CT50-LG-W10-EN-QS Rev A 8/18

User s Manual USB 3.0 Expansion Card TS-PDU3

Marathon. Quick Start Guide. Hand-Held Computer

Skynax. Mobility Management System. Installation Guide

Dolphin CT50 Non-Incendive

PrintPAD MC65. User Guide

MS5100. Eclipse Series. User s Guide

Hardware Replacement Guide

VISTA - CTI Multi-port Serial Adapter. Install Guide

Updating Reader Firmware

RA Triage Procedure. Product: DM8050 & DM8600 series. 1.0 Useful Components & Accessories

8680i Smart Wearable Accessories Guide

Quick Setup & Getting Started

Apex-ICE Universal JTAG Emulator Hardware and Software Installation Guide

2D Imaging Barcode Scanner GLLS. Programming Guide. Advanced Handheld High-Speed Laser Scanner

ViewPoint for GMPT-401 Personal Tracker

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

DISCLAIMER. advanced PANMOBIL Systems GmbH & Co. KG. All rights reserved. International support contact:

* * Agilent Power Distribution Unit (PDU) Installation Guide

Apex-ICE Universal Emulator Hardware and Software Installation Guide

Installing the A4979A PMC Graphics Card. HP Part No. A Edition E1098 Printed in U.S.A.

Bluetooth Version FUZZYSCAN FAMILY. Quick Start Guide CORDLESS SCANNER

PrintPAD MC65. User Guide

Startup Guide C01

Replacing the Battery HP t5730 and t5735 Thin Clients

Coletor de Dados Honeywell Dolphin 6000

2D Image Handheld Scanner

Upgrading and Servicing Guide

Motion LE1700 Tablet PC Hard Disk Drive Upgrade Procedure

Dolphin Power Tools. User Guide. Version 5.x for Honeywell Hand Held Computers. powered by Android 7

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

IMAGETEAM 4200 Hand Held Linear Imager. Quick Start Guide

LPC2148 DEV BOARD. User Manual.

4620, Quick Start

SD61. Base Station. User s Guide

XPS 15 2-in-1. Service Manual. Computer Model: XPS Regulatory Model: P73F Regulatory Type: P73F001

Installing a New Solo 1150 Hard Drive

GV3000/SE AC Drive ControlNet Network Communication Option Board M/N 2CN3000

Hardware Replacement Guide Types 8099, 8116, 8155, 8156 Types 8157, 8158, 8159, 8160 Types 8215, 9210, 9211

For Removable Docking Modules with 3.5"/2.5" HDD. or Optional for zip /SuperDisk LS-120/MO/TR-4 Tape or ATA Flash Memory Reader

INFINEA OMNI For ipad

Magnetek Material Handling IMPULSE LINK 4.1 Basic Instruction Manual

PB21 PB31. Mobile Receipt Printer. User Guide

AerMonitor AM Aer Monitor User's Manual. Version-0.1

Upgrading and Servicing Guide

Dell XPS 14z Owner s Manual

Getting Started. HP Business PCs

Installing the A4504A PMC Bridge Adapter and A4509A Expansion Adapter. HP Part No. A Edition E1197 Printed in U.S.A.

A/V over Gigabit Ethernet Adapter. User s Manual

742S 742i SC742 CHASSIS USER'S GUIDE

STEPPER-MOTOR-RD STEPPER MOTOR REFERENCE DESIGN KIT USER S GUIDE. 1. Kit Contents. 2. Kit Overview. Figure 1. Stepper Motor Reference Design Board

GageWay SM. Copyright MicroRidge Systems, Inc.

SPARC/MEM-20 Installation Guide

Wall-Mounting your HP TouchSmart. User Guide

Upgrading and Servicing Guide

Nuscan 3200 Optical Laser Barcode Scanner

Hardware Replacement Guide Lenovo 3000 J Series. Types 8453, 8454, 8455, 8458, 8459, 8460

LabelWriter. Print Server. User Guide

Upgrading and Servicing Guide

FCC COMPLICANCE STATEMENT

FloBoss S600+ Field Upgrade Guide

MVCI Cable User Manual X-Horse Electronics Co., Ltd.

PacketBand TDM-4 Quickstart Guide V3.2

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

GV-Card Reader. User s Manual

MICROFLASH 4T. User Guide

Inspiron 22. Service Manual Series. Regulatory Model: W17B Regulatory Type: W17B001

SENSORLESS-BLDC-MOTOR-RD

Single Site Flash Programmer. User Guide. Supports GS1011MIE, GS1011MEx, GS1011MIP, GS1011MxxS, and GS1500M Modules

ThinkCentre Hardware Installation and Replacement Guide. Machine Types 6062, 6065, 6071, 6076, 6089, 7103, 9011, 9014, 9071, 9089, 9162, 9182, 9303

User's Manual. USB DOCK - Einstein. Omnidirectional Control Technology Inc.

Upgrading and Servicing Guide

Dell Inspiron N5110 Service Manual

8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A

OWC Mercury Pro Optical ASSEMBLY MANUAL & USER GUIDE

HDD external enclosure for data-storage mobility with LAN sharing LAN MAC. USER Manual

User Manual MHD44. HDMI Matrix Switcher. All Rights Reserved. Version: MHD44_2014V1.0

70/75 Series Mobile Computer Accessories Guide

Laser Barcode Scanner Model no. LS6007 FS5027

Vela Desktop Reader User Guide

Manual Version: V1.00. Video Decoder User Manual

Manual Version: V1.00. Video Decoder Quick Guide

Transcription:

ED40 Development Kit Quick Start Guide

Disclaimer Honeywell International Inc. ( HII ) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII. HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. HII disclaims all responsibility for the selection and use of software and/or hardware to achieve intended results. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII. Copyright 2010-2016 Honeywell International Inc. All rights reserved. Web Address: www.honeywellaidc.com Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners. For patent information, please refer to www.hsmpats.com. ii ED40 Development Kit Quick Start Guide

Contents Disclaimer....................................... ii Before You Begin................................. iv Safety Information........................... iv Contact Customer Support.......................... v Product Service and Repair......................... v Warranty Information.......................... v Send Feedback.............................. v What is the ED40 Development Kit?................... 1 Development Kit Contents...................... 1 Required Accessories......................... 1 Optional Accessories.......................... 1 Introducing the ED40 Development Board.............. 2 Development Board Controls.................... 2 Power Supply Requirements.................... 4 Mounting the ED40+Imager on the Board.............. 5 Mounting the EV14 on the Board..................... 6 Operating the Development Board.................... 7 Standalone Operation.......................... 7 Host Computer Operation....................... 8 Using an RS-232 Cable............... 8 Using a USB Cable................... 9 Configuring the ED40 Using EasySet............ 10 Online Setup with EasySet............ 10 Offline Setup with EasySet............ 11 Troubleshooting.................................. 12 ED40 Development Kit Quick Start Guide iii

Before You Begin This section provides you with safety information, technical support information, and sources for additional product information. Safety Information Your safety is extremely important. Read and follow all warnings and cautions in this document before handling and operating Honeywell equipment. You can be seriously injured, and equipment and data can be damaged if you do not follow the safety warnings and cautions. This section explains how to identify and understand cautions and notes that are in this document. You may also see icons that tell you when to follow ESD procedures and when to take special precautions for handling optical parts. Follow ESD Procedures This icon appears at the beginning of any procedure in this manual that could cause you to touch components (such as printed circuit boards) that are susceptible to damage from electrostatic discharge (ESD). When you see this icon, you must follow standard ESD guidelines to avoid damaging the equipment you are servicing. Optics Because finger oils can impede the performance of scanner parts and dissolve the reflective coating of the plastic mirrors, always wear finger cots or nonpowdered latex gloves when handling optical parts. Note: Notes either provide extra information about a topic or contain special instructions for handling a particular condition or set of circumstances. iv ED40 Development Kit Quick Start Guide

Contact Customer Support To search our knowledge base for a solution or to log in to the Technical Support portal and report a problem, go to www.hsmcontactsupport.com. For our latest contact information, see www.honeywellaidc.com/locations. Product Service and Repair Honeywell International Inc. provides service for all of its products through service centers throughout the world. To find your service center, go to www.honeywellaidc.com and select Support. Contact your service center to obtain a Return Material Authorization number (RMA #) before you return the product. To obtain warranty or non-warranty service, return your product to Honeywell (postage paid) with a copy of the dated purchase record.limited Warranty Warranty Information For warranty information, go to www.honeywellaidc.com and click Resources > Warranty. Send Feedback Your feedback is crucial to the continual improvement of our documentation. To provide feedback about this manual, contact the Honeywell Technical Communications department at ACSHSMTechnicalCommunications@honeywell.com. ED40 Development Kit Quick Start Guide v

vi ED40 Development Kit Quick Start Guide

What is the ED40 Development Kit? The ED40 Development Kit is a design tool for the ED40 decode board and an imager. With the Development Kit you can verify the operation of the ED40 and connect the ED40 to your host PC to configure it. The ED40 development kit can be used with the following scan engines: EA11 EA21 EA30 (all models) EA31 EV14 (does not require ED40 decode board but supported with this development kit) Development Kit Contents Development board (ED40 decode board and scan engine ordered separately) USB cable for connection to a host system RS-232 cable (P/N 236-161-XXX) Honeywell universal power supply Ribbon cables to connect the decode board to the demo board This Quick Start Guide Required Accessories ED40 decode board + imager or an EV14 engine. A Honeywell AC power cord for your country Optional Accessories Software development kit (Contact your Honeywell OEM Sales Representative.) Three 1.5 V AA-type batteries ED40 Development Kit Quick Start Guide 1

Introducing the ED40 Development Board This section introduces the ED40 development board including information on the controls and power supply requirements. Development Board Controls Ribbon cable ED40 decode board and mounted imager Green LED (good read) Red LED (power ON) ED40 ribbon cable connector DC power jack Power switch EA30 Y-ribbon cable connector Trigger Buzzer Operating mod switch RS-232 cable connector USB cable connector Example ED40 and Imager Mounted on the Development Board 2 ED40 Development Kit Quick Start Guide

ED40 Development Board Controls Control Description Power switch ON Turns power on. OFF Turns power off. EA30 ribbon cable connector Used to connect the EA30 imager Y-ribbon cable to the development board. Note: Some EA30 models use a special Y- ribbon cable that connects the EA30 to ED40 decode board and the development board. Trigger Buzzer Operating mode switch USB cable connector RS-232 cable connector DC power jack ED40 ribbon cable connector Red LED Green LED Ribbon cable Press to scan bar codes. To configure different trigger modes see Configuring the ED40 Using EasySet on page 10. Generates an audio signal according to the configuration, for example, a good read beep or error beep. * Normal operating mode (download disabled). DWLD Download mode. The ED40 does not read bar codes in this mode. Note: To upgrade the firmware, use WinFlash (firmware download wizard) available in the EasySet software on the Honeywell website at www.intermec.com/easyset. Used to connect a USB cable. Used to connect an RS-232 cable. A power supply connected to the RS-232 cable is required for RS-232 communication. Used to connect the Honeywell external power supply if necessary. Used to connect the ribbon cable from the ED40 to the development board. The red LED turns on when the scan engine is powered-up. The green LED flashes when the scan engine performs a good read. Connects the ED40 to the development board. End marked ED40 connects to the ED40 decode board, the other end to the development board. Note: If you use your own ribbon cable, be sure to use the proper impedance match for correct USB operation (see the ED40 Integration Guide for details). The ribbon cables provided in this kit are designed to ensure proper USB interface operation. ED40 Development Kit Quick Start Guide 3

Power Supply Requirements Power for the ED40 development board can be supplied in several different ways: External power supply connected to the DC jack (only needed when USB power is insufficient) External power supply connected to the RS-232 cable Host provides power via the USB cable Battery power When the development board is powered-up, it detects the power source. Priority is given first to the DC jack, then the RS-232 or USB cables, and lastly to the batteries. This means that if you have installed batteries as well as an external power supply to the DC jack, at power-up the development board will detect the external power supply first and use this source instead of the batteries.. Note: If you decide to change the power source during operation be sure to turn the development board off, connect your new power source, then turn the development board back on so it will detect the new power source. The type of power supply you use depends on how you will be operating the development board and which cables you will be using. 4 ED40 Development Kit Quick Start Guide

Mounting the ED40+Imager on the Board To mount the ED40+Imager on the development Board 1 Place the mounted ED40+imager on the development board. Line up the screw holes on the bottom of the bracket with the holes on the development board. 2 Use the screws provided to attached the bracket to the development board. 3 Use a small screw driver or other pointed object to carefully open the ribbon cable connector. Attach the end of the ribbon cable marked ED40 to the ED40 decode board and the other end to the development board. Close the connector. An unmounted ED40+imager can also be used with the development board. Just simply connect the ribbon cable to the decode board and development board. There are no screw holes for the engine. Note: If connecting an EA30 or EA31 with a Y-cable, be sure to also connect the 6 pin end of the Y-cable to the development board. ED40 Development Kit Quick Start Guide 5

Mounting the EV14 on the Board To mount the EV14 engine on the development board 1 Use the double-sided tape provided in the kit to secure it on the development board. Double-sided tape Align the EV14 close to the left edge of the development board so that the ribbon cable is as straight as possible. 2 Open the ribbon cable connector on the EV14 and insert the ED40 end of the ribbon cable. Close the connector. EV14 Ribbon Cable Connector Open The cable connector and ribbon cable are fragile. Be very careful when opening the connector and removing the cable. Note: Ribbon cables wear out and need to be replaced after repeated connection. Honeywell recommends having a spare on hand (order from Honeywell). 6 ED40 Development Kit Quick Start Guide

Operating the Development Board You can use one of two operating methods: Standalone operation Host computer operation Standalone Operation Standalone operation allows you to turn on the development board and read bar codes. In standalone mode the development board is powered using the external Honeywell power supply connected to the DC power jack or battery power. To use standalone operation 1 Set the power switch to OFF. 2 Insert three AA batteries as shown or connect the external power supply to the DC power jack on the development board. 3 Set the operating switch to * (normal operating mode). 4 Set the power switch to ON. 5 Aim at a bar code and press the trigger. When the ED40 successfully scans a bar code the green LED flashes and the buzzer sends an audio signal. 6 When finished, set the power switch to OFF to preserve battery power. ED40 Development Kit Quick Start Guide 7

Host Computer Operation Host computer operation is when you connect the ED40 to the host with an RS-232 cable or a USB cable. This type of connection allows you to send and receive data from the host as well as configure the ED40 online using EasySet. Using an RS-232 Cable When using an RS-232 cable the development board is powered by the external power supply connected to the RS- 232 cable. RS-232 Connection with a Connected External Power Supply To use host computer operation with an RS-232 cable 1 Set the power switch to OFF. 2 Connect the RS-232 cable to the host computer and the RS-232 connector on the development board. Note: Be sure to use the correct RS-232 cable (P/N 236-161-XXX). Other RS-232 cables may provide power but will not provide a serial connection. 3 Connect the external power supply to the RS-232 cable. 4 Set the operating mode switch to * (normal operating mode). 5 Set the power switch to ON. 6 For an RS-232 cable, set the host computer serial port to 57,600 bauds, 8 data bits and no parity. 7 Aim the ED40 at a bar code and press the trigger. 8 The development board transmits the bar code data to the host. 8 ED40 Development Kit Quick Start Guide

Using a USB Cable When using a USB cable the development board is powered by the host via the USB cable. However if the host is not able to provide enough power, connect the external power supply to the DC power jack on the development board. By default the USB cable mode is Virtual COM. Install the latest Virtual COM driver before connecting the ED40 to the host for the first time. You can download the driver using the EasySet Configuration Application. Note: If you have an old Virtual COM driver installed, you must uninstall it (see Troubleshooting at the end of this guide). If you use EasySet to install the latest driver, it automatically will uninstall an old driver. Use EasySet to install the USB virtual COM port driver 1 Download and install the latest version of EasySet (we recommend that you install it in the default location proposed by the installer). 2 Start EasySet and select Options > Virtual COM driver installation. If the VCP Installer window proposes options to Repair or Remove the VCP Installer, the driver is already installed - click Cancel to exit the installation procedure. If the VCP Installer window offers to guide you through the installation, click Next and Install each time as requested to complete the VCP driver installation. To test that the install is successful, press the trigger. If the imager turns on (lighting on) the install is successful. Aim the ED40 at a bar code and press the trigger. The development board transmits the bar code data to the host. Note: To change the default Virtual COM USB cable mode to Keyboard HID, see Troubleshooting on page 12. Note: If you do not have EasySet, contact your local Honeywell OEM representative to get the latest USB driver. ED40 Development Kit Quick Start Guide 9

Configuring the ED40 Using EasySet EasySet is a configuration application that provides you with two ways to configure the ED40 development board. Online setup send configuration commands from EasySet directly to the product. Online setup is only possible in host computer operation. Offline setup send configuration commands to a bar code setup sheet, print the setup sheet and scan the bar codes. EasySet is available at www.intermec.com/easyset. Simply download and install. To reset factory default settings, scan this bar code: Reset factory defaults Online Setup with EasySet Online setup is available if you are using an RS-232 cable or a USB cable (virtual COM or keyboard HID USB cable modes). To configure the ED40 online with EasySet 1 Connect the ED40 development board to a host PC with an RS-232 cable or a USB cable as described in Host Computer Operation on page 8. 2 Start EasySet. The first time you start EasySet, the Select product dialog box appears. 3 If the Select product dialog box does not appear, choose Product > Select. 4 Select your product. 5 Select Communication > Select Communication Interface. The Communication Interface dialog box appears. 6 Select the communication interface that you are using for your ED40 and click OK. By default the communication interface is RS serial or USB Virtual Com interface. Only select USB Keyboard HID interface if you have changed the USB cable mode. 10 ED40 Development Kit Quick Start Guide

7 For RS serial or USB Virtual COM interface the Connection parameters dialog box appears. Select the COM port. Click Apply. Note: You can find the USB Virtual COM port by opening the Windows Device Manager (Open the Windows Control Panel and click on System. Click on the Hardware tab and then click on the Device Manager button.). The Virtual COM port is listed under Ports (COM & LPT). For USB Keyboard HID interface the Select Device dialog box appears. Select your device and click OK. Note: If you are using USB Keyboard HID interface, be sure to configure the keyboard for your country in EasySet (Interface > Keyboard settings). The default keyboard is North American Windows. 8 EasySet connects to your ED40 decode board and retrieves the current configuration. These settings are indicated with a blue check mark or blue text. Open the folders to find the configuration commands needed. Double click each command to send it to the ED40. Offline Setup with EasySet To configure the ED40 offline by scanning bar codes 1 Start EasySet. The first time you start EasySet, the Select product dialog box appears. 2 If the Select product dialog box does not appear, choose Product > Select. 3 Select your product. 4 Open the folders to find the configuration commands needed. Double-click each command to send it to the setup sheet. 5 Click on the Word icon to export the setup sheet to Microsoft Word. Print out the setup sheet and scan the commands. ED40 Development Kit Quick Start Guide 11

Note: For instructions on integrating and operating the ED40 with other devices, see the ED40 Decode Board Integration Guide available from your Honeywell OEM Sales Representative. Troubleshooting This section provides information for troubleshooting your ED40 development board. Problem The red LED is flashing continuously. No communication with the host when using an RS-232 cable. Communication issues with the USB interface (reliability or dropping characters) Possible Solution You may have a bad connection between the ED40 and the development board. Reconnect the ribbon cable or replace the ribbon cable. Or the RS-232 cable and USB cable are connected at the same time. Only connect one interface cable at a time. Be sure you are using the correct RS- 232 cable (P/N 236-161-xxx). Any other RS-232 cable will provide power but no communication with the host. Make sure the power supply is plugged into the cable. The red power on LED should light up when you have power plugged in on the cable. Check that the host provides enough power. If in doubt, try using the external power supply. Also, make sure you are using the proper impedance matched ribbon cable (such as the one included in this kit). Do not use ribbon cables from previous development kits. 12 ED40 Development Kit Quick Start Guide

Problem Cannot install the driver for Virtual COM USB cable mode. USB Keyboard HID Possible Solution Try changing the USB mode to Keyboard HID by reading the bar code below. To read the bar code: 1 Switch the power to OFF. 2 Unplug the USB cable. 3 Plug in the external power supply or use batteries. 4 Switch the power to ON. 5 Read the USB Keyboard HID bar code. 6 Switch the power to OFF. 7 Plug in the USB cable. 8 Switch the power to ON. Now you are in Keyboard HID USB cable mode. Depending on your host the power supply may not be necessary. To revert back to Virtual COM USB cable mode, read the reset factory defaults bar code on page 10. By default the international keyboard is North American Windows. If you are using a different keyboard use EasySet to select the correct keyboard. Need to manually uninstall the USB serial driver. To manually uninstall the USB serial driver: 1 Open the Control Panel, Programs and Features. 2 Select the driver in the list of programs. 3 Then click Uninstall. ED40 Development Kit Quick Start Guide 13

Honeywell 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com ED40 Development Kit Quick Start Guide 3-24049-31 P/N 3-24049-31