MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Similar documents
User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: Fax:

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

User Manual V1.0 SDM230-DR. Single-Phase Two Module DIN rail Meters

SUBJECT TO CHANGE WITHOUT NOTICE

SDM530CT-Modbus USER MANUAL 2015 V1.6. Three Phase Multi-function DIN rail meter. Eastron SDM530CT-Modbus User Manual

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

SDM530-Modbus USER MANUAL 2015 V1.5. Three Phase Multi-function DIN rail meter. Eastron SDM530-Modbus User Manual

USER MANUAL 2012 V1.1

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

EngyVolt RV12 and RV15

EM270. Multi-channel power analyzer. Benefits. Description

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

Digital Multifunction Meters. Digital Multifunction Meters

EM271. Multi-channel power analyzer. Benefits. Description

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

DZT Line Deutsche Zähler Technik

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Energy Management Energy Transducer Type ET112

Installation and Operating Instructions

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Multifuncion Measuring Device 96x96 mm, connection via CT

MIC-2 Multi-instrument DATA SHEET

INTEGRA DIGITAL METERING SYSTEMS

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Multifunction Transducer MT440

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Power Meter PowerMonitor 500

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

CEM-C30 INSTRUCTION MANUAL (M017B A)

NEMO HD MULTI-FUNC METER BASE (MF96001)

COUNTIS E05. Single-phase energy meter Direct - 40 A M-BUS. Instruction manual. en/countis-e0x

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

Energy Management BUS Adapter Type VMU-B

WM20. Power analyzer for three-phase systems. Benefits. Description

Energy Management BUS Adapter Type VMU-B 01

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Technical Specifications. Multi Function Meter

MID Energy Counters. Getting together is a beginning, staying together is a progress, working together is an achievement.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

OB735 Smart Energy Meter

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Product Manual for the Mini Industry Meter MIZ Installation I Device description I Operation

Metering Devices IQ 300

02/11/2015

TECHNICAL DESCRIPTION WM1 6, WM1M6

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Single-phase Energy meter

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

with Backlight Graphic LCD Screen

ANALIZZATORE DI RETE TRIFASE 90A

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

08/07/2015

PMC 530 Series Advanced Multifunction Meter

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Acti 9 iem3000 Series Energy Meters Functions and characteristics

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

User s Manual. Single phase electrical energy meter WM1 6 Single phase electrical energy meter WM1 6Z Single phase electrical energy meter WM1M6

02/11/2015

RM35TF V AC

Energy Division. Crompton Instruments Integra 1630 Low Profile Digital Metering System

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Controls Division. Mounting. Mounting Terminal connections main circuit. Terminal connections control circuit. Insulation characteristics

SPEM Series ... SPARK. Model: SPEM1 USER MANUAL. Spark Energy Management Solutions Private Limited

Data sheet Single phase Energy meter with integrated S-Bus interface

Energy Management Modular Energy meters Type EM2-96

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

PRO1-S PRO1-2T PRO1-Mb PRO1-Mod. PRO1 Series MID Single phase energy meter. User manual. Version: Inepro B.V. All rights reserved

02/11/2015

Smart energy meter. Benefits and Features. User Manual Revision English. 103EM series

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

4 Is this model available for special primary current and special primary voltage?

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Smart Energy Meters Noark Electric Europe s.r.o.

Transcription:

PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight Import and export energy measurement RS485 Modbus or Mbus models available Two module width DIN rail mounted MID +D Certified (SGS Cert. No. : ----/-------) Simple programming and operation Auto or manual page scrolling Product Description The RI-D35-100 series is a range of single phase multifunction DIN rail MID approved energy meters. Suitable for monitoring energy consumption in residential, solar pv, industrial and utility applications. All models are MID approved ( and D) and may be used for billing purposes. A high efficiency white backlit LCD display provides a clear indication of measured values in all light conditions. Displayed Parameters Phase to Neutral Voltage (V) Phase Current (A) Frequency (Hz) Power Factor (PF) Power Max. Demand (MD kw) Active Power (kw) Reactive Power (kvar) The meter is available in two versions:- Single tariff with two pulse outputs and RS485 Modbus communication. Single tariff with two pulse outputs and Mbus communication. The unit is housed in a compact two module width case suitable for 35mm DIN rail mounting. MID MID APPROVED FOR ILLING APPLICATIONS Measuring Instruments Directive Apparent Power (kva) Import Active Energy (kwh) Export Active Energy (kwh) Total Active Energy (kwh) Import Reactive Energy (kvarh) Export Reactive Energy (kvarh) Total Reactive Energy (kvarh) www.rayleigh.com 1

Display Display Type Digit height Page scrolling LCD, high definition with white back-light 4mm (displayed value) Manual by front key / or auto scroll mode Displayed parameters and accuracies Voltage 0.5% of Max. range Current 0.5% of nominal Frequency 0.2% of nominal frequency Power factor 1% of unity (0.01) Active power 1% of range maximum Reactive power 1% of range maximum Apparent power 1% of range maximum Active Energy Class (IEC/EN50470) / Class 1 (IEC/EN62053-21) Reactive Energy 1% of range maximum Time & Date 0.5 Sec/24Hr Energy maximum display 99999.99 Resolution 10wh Programming Programmable parameters Programming access Memory retention Primary address - Mbus version only Secondary address - Mbus version only Pulse output (kwh or kvarh) Pulse output resolution Pulse duration Demand period (for integration) Auto page scroll time ack-light time-out period Reset Max. demand Change password Communication address - Modbus version Communication speed (aud) - Modbus and Mbus versions Communication Parity - Modbus and Mbus versions Password protected (user selectable) Non volatile memory (EEPROM) Input Connection Single phase only Input voltage (Un) 230V Operating voltage range 176 276V Voltage circuit power consumption (Max.) <8VA Current rating (Imin-Iref) 0.5 10A Max current (Imax) Current circuit power consumption (Max.) 0.5VA Starting current 40mA Short time overcurrent 30 Imax/ 10mS (IEC/EN 62053-21 and -23) Impulse voltage withstand 6kV 1.2µS AC voltage withstand 4kV for 1 minute CT ratio range N/A direct connection VT ratio range N/A direct connection www.rayleigh.com 2

Frequency Current distortion factor 50Hz According to IEC/EN50470 Auxiliary Supply Voltage range Operating frequency Power consumption Self supplied from measuring input See input section See input section Outputs Energy pulses Number of pulse outputs 2 Pulse output function Pulse output type Pulse output Max. current Pulse output voltage range Pulse duration 1 x 1000imp/kWh. 1 x User configurable pulse rate and energy type (kwh or kvarh) Semiconductor (does not support volt-free operation) 27mA (Class A to IEC/EN62053-31) 5 27VDC Selectable 60, 100, 200mS Selectable pulse resolution 0.001, 0.01, 0.1, 1 Communication - Modbus Version Communication protocol Modbus Address 1 255 Number of bits Parity 8bits None, odd, even aud rate 1200, 2400, 4800, 9600 Required response time to request Number of meters connected on the bus Max. distance from Master device 100ms 32 (up to 255 with RS485 repeater) 1200M Communication - Mbus Version Communication protocol Communication standard Mbus IEC/EN13757 Primary address 1 250 Secondary address 0 99999999 Parity None, odd, even aud rate 300, 600, 1200, 2400, 9600 Insulation Installation category III Pollution degree 2 Insulation voltage rating 300V www.rayleigh.com 3

Environmental Conditions Reference temperature Specified temperature operating range Storage temperature Relative humidity Mechanical environment Electromagnetic environment Maximum altitude 23 C ±1 C 10 C +55 C 20 C +70 C 0 95%, non condensing M1 E2 3000m Mechanical Housing Housing Type 2 module DIN 43880 Mounting Tamper sealing Housing material Protection degree (IEC/EN60529) Weight Snap-on 35mm rail Terminal cover and meter housing (meter housing by means of a tamper sticker) Self-extinguishing polycarbonate (UL94 V-0) IP20 (terminals), IP51 (front of housing) 170g Termination Current input terminal type Screw type - rising clamp Max. wire size 35mm 2 Voltage input terminal type Max. wire size Output terminal type Combined with current circuit N/A Screw type - rising clamp Max. wire size 2.5mm 2 Conformity Electromagnetic compatibility Emission and immunity tests according to IEC/EN50470 Immunity test according to IEC/EN50470 Accuracy and functionality IEC/EN50470-1:2006 - Electricity metering equipment (a.c.). Part 1: General requirements, tests and test conditions Metering equipment (class indexes A, and C) IEC/EN50470-3:2006 - Electricity metering equipment (a.c.) Part 3: Particular requirements Static meters for active energy (class indexes A, and C) EC Directive 2004/22/EC www.rayleigh.com 4

EN50470-1/3 EN50470-1/3 PRELIMINARY DATA SHEET Wiring Diagrams RI-D35-C (Modbus) RI-D35-M (Mbus) 2 1 GND A 2 1 US1 US2 PULSE OUTPUT RS485 PORT PULSE OUTPUT MUS PORT 4 5 6 7 8 9 4 5 6 7 8 9 RI-D35 RI-D35 Display Window Size : 23.35mm x 21.35mm 1 2 Display Window Size : 23.35mm x 21.35mm 1 2 1 2 3 1 2 3 L IN L OUT L IN L OUT N N Dimensions 47mm 90mm 45mm 90mm 35mm Model Selection Table Tariffs and Communications Single-tariff with Modbus Output Single-tariff with M-bus Output Model RI-D35-100-C RI-D35-100-M www.rayleigh.com 5