Time Delay Values (A, B, C & D-Series) AC 10000

Similar documents
PERCENT OF RATED CURRENT

PERCENT OF RATED CURRENT

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

C-Series. Circuit Breaker

C-Series. Circuit Breaker

Time Delay Values (E-Series)

D-Series. Circuit Breaker

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

E-Series General Specifications

D-Series CIRCUIT BREAKER

E-Series General Specifications

APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG

Transforming Customer Needs into Customer Solutions

IELR Rail-Mount Series Magnetic Circuit Protectors

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

M-Series. Circuit Breaker

APL/UPL, 205/295 Series Magnetic Circuit Protectors

Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles

IELR Series

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

PC-Series Ground Fault Circuit Protection

209/219/229/249/279 SERIES HYDRAULIC MAGNETIC CIRCUIT PROTECTORS

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

IELR Rail-Mount Series Magnetic Circuit Protectors

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal-Magnetic Circuit Breaker 2216-S

Introduction Circuit Protection

PD-Series General Specifications

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

V-Series. Contura Rotary Switch

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

IAR/IUR/IER/CUR/CER Series 1RU Magnetic Circuit Protectors

W69-X2Q12-20 Product Details

9926 Series Branch Rated Circuit Breakers AC Version

Circuit Protectors CP31E, 32E, 33E, 34E CP31V, 32V, 33V, 34V

PERFORMANCE SPECIFICATION

Model 720 Electromechanical Hour Meter

1492-SP Supplementary Protectors

W91-X Product Details

M-Series General Specifications

Process Sealed Rotaries

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Thermal-Magnetic Circuit Breaker 4220-T...

3 Series Thumbwheel Switches

Model Number Structure

Sealed Rocker Switches V-Series: Contura IV & V

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

AE/CE Series Industrial Control Transformers

Solid-state Timer H3YN

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Model Number Structure

AE/CE Series Industrial Control Transformers

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

JAY-EL JAY-EL P/N ILLUMINATED PUSHBUTTON SWITCH MEETS REQUIREMENTS OF MIL-S-22885

CROWN LINE Power Bus Bar Distribution System

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

Bulletin 817 Thermistor Protection Relay

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Magnetically Actuated Safety Interlock Switches

Sealed Rocker Switches. V-Series: Contura X, XI & XII

TeSys SK, K, D. Technical Data for Designers. Contents

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

AZ420 MINIATURE GENERAL PURPOSE RELAY

ILLUMINATED PUSHBUTTON SWITCH

PERFORMANCE SPECIFICATION SHEET

Micro Contactor MA Series

General Specifications

60103 Circuit Breaker

ALLEN BRADLEY RELAY Bulletin 700-HF

PERFORMANCE SPECIFICATION SHEET

UP1-1WF UP1-3TF UP1-5TF UP1-8TF. Applications. Ambient temperature Operation Storage. Degree of protection: Accessible range:

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Bulletin 700-HA Tube Base Relay

V REG.-Nr. 3919, Z E214024

KEPCO GIVES YOU ZERO-UP PROGRAMMABILITY IN AN AFFORDABLE POWER MODULE

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

H3CA-8H-AC/100/110/120

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Section 4 Ground-Fault Protection Devices

POWER ROCKER SWITCH. Standard actuator type Wide actuator type UL/C-UL, ENEC/VDE UL/C-UL, ENEC/VDE

PERFORMANCE SPECIFICATION SHEET

Voltage Current Front-mounting bracket

3 Pole Contactors with AC operating coils

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

Type CBW57 Thermal Circuit Breaker Push to Reset Low Profile

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection

Push-Pull and E-Stop Switches. Datasheet

General Specifications

Model Number Structure

7. Approved Standards US: UL, CSA UL: FILE No.E CSA: FILE No.LR31928) 8. Special Function None : Standard U : For ultrasonically cleanable

SECTION DISCONNECT SWITCHES

E-STOP relays, safety gate monitors

Transcription:

Time Delay Values (A, B, & D-Series) A 0 Instantaneous INSTANTANEOUS URVE. 20 0 D D.. INSTANTANEOUS URVE. 0 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0 Ultrashort.00 0 200 300 400 500 600 700 800 900 200 25 50 PERENT OF RATED URRENT ULTRASHORT DELAY URVE. 2.00 0 200 25 50 300 400 500 600 700 800 PERENT OF RATED URRENT 900 D.. ULTRASHORT DELAY URVE. 200 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0 Short.00 0 200 25 50 300 400 500 600 700 800 PERENT OF RATED URRENT 900 SHORT DELAY URVE. 22 200.00 0 25 50 200 300 400 500 600 700 800 900 200 PERENT OF RATED URRENT D.. SHORT DELAY URVE. 2 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0 Medium.00 0 200 300 400 500 600 700 800 900 200 25 50 PERENT OF RATED URRENT MEDIUM DELAY URVE. 24.00 0 200 300 400 500 600 700 800 900 200 25 50 PERENT OF RATED URRENT D.. MEDIUM DELAY URVE. 4 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0 Long.00 0 200 25 50 300 400 500 600 700 800 PERENT OF RATED URRENT 900 LONG DELAY URVE. 26 200.00 0 600 200 300 400 500 700 800 900 200 25 PERENT OF RATED URRENT 50 D.. LONG DELAY URVE. 6 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0.00 200 300 400 500 600 700 800 900 200 25 TES 50 PERENT OF RATED URRENT 50 PERENT OF RATED URRENT UL489 -Series Breakers available with Dealy urves, 2, 4, 6, 2, 22, 24, 26, 42, 44, 46 Delay urves,2,4,6,2,22,24,26,42,44,46: Breakers to hold % and must trip at 25% of rated current and greater within the time limit shown in this curve. Delay urves 32,34,36: Breakers to hold % and must trip at 35% of rated current and greater within the time limit shown in this curve. Delay urves 0,20: Breakers to hold % and must trip at 50% of rated current and greater within the time limit shown in this curve. All urves: urve data shown represents breaker response at ambient temperature of 77 F (25 ) with no preloading. Breakers are mounted in standard wall-mount position. On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 2 times the rated current on standard delays and 25 times the rated current on high inrush delays. These values are based on a 60 Hz /2 cycle, 8 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive and transformer loads..00 200 25 300 400 500 600 700 800 900 200 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

Time Delay Values (A, B, & D-Series) Short 0 HI-INRUSH A Delay urves - HI - INRUSH SHORT DELAY URVE. 42 Dual Rated A/D Delay urves 0 D.., SHORT DELAY URVE. 32 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0.00 200 25 50 300 400 500 600 700 800 PERENT OF RATED URRENT 900 200.00 200 35 50 300 400 600 500 700 800 900 200 PERENT OF RATED URRENT Medium 0 - HI - INRUSH MEDIUM DELAY URVE. 44 0 D.., MEDIUM DELAY URVE. 34 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0.00 200 300 400 500 600 700 800 900 200.00 200 300 400 500 600 700 800 900 200 Long 0 25 50 PERENT OF RATED URRENT - HI - INRUSH LONG DELAY URVE. 46 0 35 50 PERENT OF RATED URRENT D.., LONG DELAY URVE. 36 TRIP TIME IN SEONDS 0. TRIP TIME IN SEONDS 0..0.0.00 200 300 400 500 600 700 800 900 200.00 200 300 400 500 600 700 800 900 200 TRIP TIME (SEONDS) DELAY 0 2 4 6 20 2 22 24 26 32 34 36 42 44 46 52 54 56 25 50 35 PERENT OF RATED URRENT 50 % 25% MAY TRIP.03 -.25.500-6.50 2.00-60.0 45.0-345 MAY TRIP.04 -.50.700-2.0 0.0-60 50.0-700 MAY TRIP MAY TRIP MAY TRIP.700-2.0 7.00-50.0-700.500-6.50.50-50.0 45.0-345 35% - - - - - - - - - -.400-8.00.80-35.0-520 - - - - - - 50%.032 MAX.00 -.070.300-3.00.20-40.0 20.0-50.040 MAX.0 -.095.350-4.00 6.00-60.0 32.0-350.300-4.00.20-60.0 20.0-350.400-6.00 3.00-50.0 3.0-350.340-4.50.750-35.0 9.0-70 PERENT OF RATED URRENT 200%.024 MAX.008 -.032.30 -.20.600-20.0 9.00-60.0.035 MAX.008 -.055.30 -.30 2.20-20.0 0.0-90.0.30 -.30.600-20.0 9.00-90.0.80-2.30.0-8.0 2.0-50.80-2.30.350-8.0 8.50-400%.020 MAX.006 -.020.03 -.220.50-3.00.40 -.4.030 MAX.006 -.035.027 -.220.300-3.00.50-5.0.027 -.220.50-3.00.40-5.0.050 -.600.220-3.00.50-20.0.05 -.600.0-3.00.24-5.0 600%.08 MAX.005 -.020.0 -.20.030 -.30.50-5.80.025 MAX.005 -.027.008 -.30.050 -.30.500-7.00.008 -.30.030 -.30.50-7.00.026 -.300.20 -.70.700-0.0.030 -.320.070 -.70.40-9.00 PERENT OF RATED URRENT 800%.06 MAX.004 -.020.004 -.090.004 -.600.009-3.70.020 MAX.005 -.02.004 -.090.007 -.500.020-3.00.004 -.090.004 -.600.009-3.70.08 -.200.075 -.20.404-7.90.08 -.220.045 -.40.256-8.00 %.05 MAX.004 -.020.004 -.060.004 -..005 -.70.07 MAX.004 -.08.004 -.045.005 -.060.006-2.00.004 -.060.004 -.0.005-2.00.04 -.50.050 -.850.260-6.50.04 -.200.039 -.30.20-5.50 200%.03 MAX.004 -.020.004 -.040.004 -..005 -.500.05 MAX.004 -.07.004 -.040.005 -.040.005 -.00.004 -.040.004 -..004 -.00.02 -.30.042 -.720.98-5.80.02 -.30.035 -.30.98-2.90 TES UL489 -Series Breakers available with Delay urves, 2, 4, 6, 2, 22, 24, 26, 42, 44, 46. Delay urves,2,4,6,2,22,24,26,42,44,46: Breakers to hold % and must trip at 25% of rated current and greater within the time limit shown in this curve. Delay urves 32,34,36: Breakers to hold % and must trip at 35% of rated current and greater within the time limit shown in this curve. Delay urves 0,20: Breakers to hold % and must trip at 50% of rated current and greater within the time limit shown in this curve. All urves: urve data shown represents breaker response at ambient temperature of 77 F (25 ) with no preloading. Breakers are mounted in standard wall-mount position. On 50 amp and less current ratings, the minimum inrush pulse tolerance handling capability is 2 times the rated current on standard delays and 25 times the rated current on high inrush delays. These values are based on a 60 Hz /2 cycle, 8 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration such as switching power supplies, highly capacitive and transformer loads. 2 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

Time Delay Values (A, B, & D-Series) HI-INRUSH D Delay urves Short 0 D.. - HI - INRUSH SHORT DELAY URVE. 52 TRIP TIME IN SEONDS 0..0.00 200 300 400 500 600 700 800 900 200 25 50 PERENT OF RATED URRENT Medium 0 D.. - HI - INRUSH MEDIUM DELAY URVE. 54 TRIP TIME IN SEONDS 0..0.00 400 600 200 300 500 700 800 900 200 25 PERENT OF RATED URRENT 50 Long 0 D.. - HI - INRUSH LONG DELAY URVE. 56 TRIP TIME IN SEONDS 0..0.00 200 300 400 500 600 700 800 900 200 25 50 PERENT OF RATED URRENT arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 3

A-Series A-Series Handle Actuator ompact, temperature stable, magnetic design for precision operation in domestic market applications. -6 poles (handle), -3 poles (rocker), 0.02-50 amps, up to 277 VA or 80 VD, with a choice of time delays, terminals and actuator colors. When front panel operation and aesthetics demand a clean contemporary design, the unique visi-rocker two-color actuator can be specified to indicate either the ON or the TRIPPED/OFF mode. Available in three Visi-Rocker color combinations and seven solid colors. New A-Series Rockerguard and push-toreset bezel help prevent inadvertent actuation. A-Series Rocker Actuator Agency Approvals UL Recognized under the omponent Recognition Program as Protectors, Supplementary (Guide QVNU2, File E75596), UL Standard 077. Switches, Industrial ontrol (Guide NRNT2, File E48683), UL Standard 508. Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596), UL Standard 500 (Ignition - Protection). SA ertified under lass 9090, File LR47848. VDE ertified to DIN VDE 0660, Part 0/09.82 under VDE - Reg.- Nr. 2495. (VDE on rocker style only) UL SA VDE UL500 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 35

A-Series Handle General Specifications ELETRIAL Table A: Lists UL Recognized, SA & VDE ertified configurations & performance capabilities as a omponent Supplementary Protector. (VDE for rocker style only.) IRUIT ONFIGURATION SERIES DUAL OIL SHUNT RELAY SWITH ONLY MAX RATING 65 80 25/ 25/ 277 80 277 80 277 80 277 65 80 277 ( ) AS A OMPONENT SUPPLEMENTARY PROTETOR VOLTAGE FREQUENY D.. D.. D.. D.. D.. D.. D.. PHASE & 3 Ø & 3 Ø Ø Ø Ø ( ) Ø & 3 Ø & 3 Ø Ø & 3 Ø & 3 Ø Ø & 3 Ø & 3 Ø Ø & 3 Ø Ø URRENT RATING FULL AMPS 3-50 0.02-20 2-30 3-50 3-50 0 02-30 0.02-20 2-30 0.02-20 2-30 0.02-20 2-30 0.02-50 0.02-50 INTERRUPTING APAITY, AMPS with BAKUP FUSE without BAKUP FUSE UL/SA UL/SA. VDE. 5000 ( ) 2000 ( ) [5000] ( ) 2000 ( ) 5000 ( ) 5000 ( ) 2000 ( ) [5000] ( ) 5000 ( ) 3500 ( ) 5000 ( ) 2000 ( ) [5000] ( ) 5000 ( ) 3500 ( ) 5000 ( ) 2000 ( ) [5000] ( ) 5000 ( ) 3000 3000 3000 2000 3000 3000 3000 500 500 500 3000( ) 500( ) 500( ) 500 500 500 Table B: Lists UL Recognized, SA ertified configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL Standard 500. UL lassified Small raft Electrical Devices, Marine in accordance with ISO8846 (Guide UZMK, File MQ55) as Marine Supplementary Protectors. UL - 500 (MARINE IGNITION PROTETED) IRUIT ONFIGURATION MAX RATING VOLTAGE FREQ. PHASE URRENT RATING FULL AMPS INTERRUPTING APATIY AMPS SERIES 65 25/ D.. - Ø Ø 0.02-50 0.02-50 500 () 500 () () Maximum Voltage 277VA, 80VD urrent Ratings Standard current coils: 0., 0., 0.500, 0.750,.00, 2.50, 5.00, 7.50, 0.0, 5.0, 20.0, 25.0, 30.0, 35.0, 40.0, 50.0. Other ratings available - consult factory. Standard Voltage oils D - 6V, 2V; A - 20V, other ratings available, consult factory. Auxiliary Switch Rating SPDT; 0. AMPS - VA, 5.0 AMPS-30VD, 0. Amps - 25VA (with gold contacts). Insulation Resistance Minimum of Megohms at 500 VD. Dielectric Strength UL, SA - 500V 60 Hz for one minute between all electrically isolated terminals. A-Series rocker circuit breakers comply with the 8mm spacing and 3750V dielectric requirements from hazardous voltage to operator accessible surfaces per IE Publications 950, EN 60950 and VDE 0805. TES FOR TABLE A:. Interrupting capacities are without backup series fusing. ( ) Requires branch-circuit backup with a UL LISTED Type K5 or RK5 fuse at no more than four times the rating of the highest rated protector (5A minimum). ( ) Same as above ( ) except that the backup fuse is limited to 80A max. ( ) 2 pole protector required (with one pole per power line): for /25VA, 25/VA and 208Y 20VA Power Systems. pole protector required: for 25VA, Ø Power System. ( ) Dual coil shunt trip only, VDE ertified TES FOR TABLE B:. Units do not require backup (series) fusing. 36 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

A-Series General Specifications (cont.) Resistance, Impedance Values from Line to Load Terminal - based on Series Trip ircuit Breaker 0 URRENT (AMPS) 0. - 5.0 5. - 20.0 20. - 50.0 TOLERANE (%) ±5 ±25 ±35 O H M S 0. 0.0 0.00 0.0 0. 0 AMPERE RATING Pulse Tolerance urves 60 Hz /2 ycle Inrush Pulse Tolerance Multiple of Rated urrent 25x 2x I r Time Delay urves 42, 44 & 46 (50 Amps Max.) Time Delay urves 22, 24, 26 (70 Amps Max.) Multiple of Rated urrent 22x 0x I r 50 Hz /2 ycle Inrush Pulse Tolerance Time Delay urves 42, 44 & 46 (50 Amps Max.) Time Delay urves 22, 24, 26 (70 Amps Max) t t 4.65 8.33 6.67 Time in Milliseconds 5.0 0.0 20.0 Time in Milliseconds MEHANIAL Endurance Trip Free Trip Indication ENVIRONMENTAL Environmental Shock Vibration Moisture Resistance Salt Spray Thermal Shock Operating Temperature 0,000 ON-OFF operations @ 6 per minute; with rated urrent and Voltage All A-Series ircuit Breakers will trip on overload, even when the actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the circuit breaker to trip. When mid-trip handle is specified, the handle moves to the mid position on electrical trip of the circuit breaker. When mid-trip handle with alarm switch is specified, the handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. Designed and tested in accordance with requirements of specification MIL--55629 and MIL- STD-202 as follows: Withstands Gs, 6ms, sawtooth while carrying rated current per Method 23, Test ondition I. Instantaneous and ultra-short curves tested @ 90% of rated current. Withstands 0.060" excursion from 0-55 Hz, and 0 Gs 55-500 Hz, at rated current per Method 204, Test ondition A. Instantaneous and ultrashort curves tested at 90% of rated current. Method 06D; ten 24-hour cycles @ + 25 to +65, 80-98% RH.56 days @ +85, 85% RH. Method 0, ondition A (90-95% RH @ 5% Nal Solution, 96 hrs). Method 07D, ondition A (Five cycles @ -55 to +25 to +85 to +25 ). -40 to +85 PHYSIAL Number of Poles - 6 Poles (handle) and -3 poles (rocker) at 30 Amps or less. and 2 poles at 3 Amps thru 50 Amps. Internal ircuit onfigurations Series, (with or without auxiliary switch), Shunt and Relay with current or voltage trip coils, Dual oil, Switch Only with or without auxiliary switch. Weight Approximately 65 grams/pole (Approximately 2.32 ounces/pole) Standard olors Housing - Black; Actuator- See Ordering Scheme. arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 37

A-Series Handle ircuit and Terminal Diagrams 2 TERMINALS IRUIT BREAKER PROFILE IRUIT SHEMATI ANSI SWITH ONLY ( OIL) IRUIT ODE AUX SWITH ODE IRUIT SHEMATI ANSI SERIES TRIP IRUIT ODE AUX SWITH ODE MAIN TERMINALS (SEE TABLE A) A 0 B 0.640 [4.66] 5 TERMINALS.520[3.2] SWITH ONLY ( OIL) WITH AUXILIARY SWITH SERIES TRIP WITH (3) AUXILIARY/ALARM SWITH.205[5.2] 3 TERMINALS N STANDARD AUX. SWITH TERMINALS N ALARM SWITH TERMINALS N N A N0 2 3 4 SHUNT TRIP N0 N STANDARD AUX. SWITH ALARM SWITH DUAL OIL; SERIES TRIP URRENT OIL, SHUNT TRIP VOLTAGE OIL B 2 3 4.390[9.9] SHUNT D E 0 VOLTAGE OIL H 0 4 TERMINALS RELAY TRIP DUAL OIL; SERIES TRIP URRENT OIL, RELAY TRIP VOLTAGE OIL.780[9.8] RELAY F G 0 VOLTAGE OIL K 0.390[9.9] RELAY TES All dimensions are in inches [millimeters]. 2 Tolerance ±.05 [.38] unless otherwise specified. 3 Alarm Switch available with.0 x.020 Q.. & Solder Lug Terminals Only. 38 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

A-Series Handle ircuit and Terminal Diagrams IRUIT BREAKER MODE HANDLE POSITION VS. AUX/ALARM SWITH MODE STANDARD /B HANDLE POSITION AUX. SWITH MODE HANDLE POSITION MID TRIP /B ALARM SWITH MODE 30 30 OFF OFF O N OFF O N ON I ON I ON 30 N 30 N ELETRIAL TRIP 30 OFF O N MID TRIP 90 N AUXILIARY/ALARM SWITH TERMINAL DETAIL TERMINAL DIMENSIONAL DETAIL & RATING.344[8.74].[6.35].25[3.8].360[9.4].392[9.96].392[9.96].050 DIA [Ø.27] TAB (Q..).0[2.79].093[2.36].39[3.53].058 DIA[Ø.47] TAB (Q..) SOLDER E.[6.35].069[.75] DIA TAB (Q..) <=30 AMP UPTURN LUG.375[9.53] #8-32 <= 30 AMP #0-32 <= 30 AMP M5 <= 30 AMP.375[9.53] BUS #8-32 <= 30 AMP #0-32 <= 50 AMP MID TRIP ON I OFF O SEE TABLE B DEPTH BEHIND PANEL.032 [.8] (NETZ).560 [39.62] MAIN TABLE B TERMINAL DESRIPTION SHUNT, RELAY & DUAL OIL TAB (Q..) SREW E TAB (Q..) SREW #8-32 W/UPTURNED LUGS DEPTH BEHIND PANEL 2.000 [50.80] 2.032 [5.60] 2.207 [56.0] 2.364 [60.05].640 [4.66] REF.220 [5.59] (LAST) * AUX. SWITH.093 TAB (Q..).0 TAB (Q..) SOLDER E 2.095 [53.20] 2.89 [55.60].970 [50.00] * AVAILABLE ON SERIES TRIP AND SWITH ONLY IRUITS. WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, AS SHOWN IN MULTI-POLE IDENTIFIATION SHEME. SEE PAGE TES All dimensions are in inches [millimeters]. 2 Tolerance ±.05 [.38] unless otherwise specified. arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 39

A-Series Handle Form and Fit Drawings #6-32 [M3] THREAD X.95 [4.95] DEEP 2 PLS PER POLE.60 [5.49].30 [3.30].640 [4.66] ON -POLE (AA).660 [42.6].590 DIA [Ø4.99] 2.000 [50.80] 60 OFF.560 [39.62].70 [4.32].755 [9.8] MAX.690 [7.50] 2.000 [50.80] 2.032 [5.6] TAB (Q..) E SREW E TAB (Q..) E TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS. IAL - OPTIONAL "ON-OFF" LEGEND 2-POLE (AA2) 2-POLE (AB2).750 [9.05].55 [38.48] MAX.55 [38.48] MAX 3-POLE (AA3) 3-POLE (AB3).750 [9.05] 2.265 [57.53] MAX 2.265 [57.53] MAX 4-POLE (AA4) MULTI-POLE HANDLE TIE KIT SHIPPED BULK 4-POLE (AB4).750 [9.05] 3.05 [76.58] MAX 3.05 [76.58] MAX.56 DIA [Ø3.96] 2 PLS PER POLE +.00 [+.25] -.000 [-.00].630 DIA [Ø6.00] ONE PER POLE.660 [42.6].050 [26.67].750 [9.05] PER POLE AA, AB2, AB3 AA2, AB4 AA3 AA4 PANEL UTOUT DETAIL TOLERANES ±.005 [±.2] UNLESS OTHERWISE SPEIFIED TES All dimensions are in inches [millimeters]. 2 Tolerance ±.00 [.25] unless otherwise specified. 40 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

A-Series Handle Form and Fit Drawings - Front Panel Snap-in Mounting Style 5.25 [3.8].640 [4.66].560 [39.62].755 [9.8] MAX BREAKER WIDTH POLE (AA) 2.598 [65.99] 60 ON 2.000 [50.80].220 [3.00] OFF.744 [8.90].690 [7.50] 2.000 [50.80] 2.032 [5.6]. TAB (Q..) E SREW E TAB (Q..) E TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS. 2 POLE (AA2) 2 POLE (AB2) ±.00 [±.25].530 [38.86] ±.00 [±.25] 2.280 [57.9] ±.00 [±.25] 3.030 [76.96] ±.00 [±.25].770 [9.56].488 [37.80].488 [37.80] ±.02 [±.30] 2.87 [55.55] 3 POLE (AA3) 3 POLE (AB3) AA AA2, AB2 AA3, AB3 2.232 [56.69] 2.232 [56.69] AA4, AB4 PANEL UTOUT DETAIL 4 POLE (AA4) 4 POLE (AB4) 2.976 [75.59] 2.976 [75.59] MULTI-POLE HANDLE TIE KIT SHIPPED BULK TES All dimensions are in inches [millimeters]. 2 Tolerance ±.00 [.25] unless otherwise specified. arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 4

A-Series Handle Form and Fit Drawings - Front Panel Snap-in Mounting Style 7.25 [3.8].640 [4.66].560 [39.62].755 [9.8] MAX BREAKER WIDTH 2.598 [65.99] ON 2.000 [50.80] POLE (AA) 60 OFF.220 [3.00].960 [24.38].690 [7.50] 2.000 [50.80] 2.032 [5.6]. TAB (Q..) E SREW E TAB (Q..) E TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS, SEE IRUIT AND TERMINAL DIAGRAMS. ±.00 [±.25] 3.030 [76.96] 2 POLE (AA2) 2 POLE (AB2) ±.00 [±.25] 2.280 [57.9] ±.00 [±.25].530 [38.86] ±.00 [±.25].770 [9.56].700 [43.8].700 [43.8] ±.02 [±.30] 2.87 [55.55] 3 POLE (AA3) 3 POLE (AB3) AA AA2, AB2 AA3, AB3 2.450 [62.23] 2.450 [62.23] AA4, AB4 PANEL UTOUT DETAIL 4 POLE (AA4) 4 POLE (AB4) 3.90 [8.03] 3.90 [8.03] MULTI-POLE HANDLE TIE KIT SHIPPED BULK TES:. ALL DIMENSIONS ARE IN INHES [MILLIMETERS] 2. REOMMENDED PANEL THIKNESS:.040[.02] TO.[2.54] 3. TOLERANE ±.05 [.38] UNLESS OTHERWISE SPEIFIED. TES All dimensions are in inches [millimeters]. 2 Recommended panel thickness:.040 [.02] to. [2.54]. 3 Tolerance ±.05 [.38] unless otherwise specified. 3 Schematic shown represents current trip circuit. 42 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

A-Series Rocker ircuit and Terminal Diagrams 2 TERMINALS IRUIT BREAKER PROFILE IRUIT SHEMATI ANSI IE SWITH ONLY ( OIL) (NETZ) IRUIT ODE AUX SWITH ODE ANSI IRUIT SHEMATI IE SERIES TRIP (NETZ) (3) IRUIT ODE AUX SWITH ODE MAIN TERMINALS (SEE TABLE A) A 0 B 0 5 TERMINALS.640 [4.66].020 [.5] (LAST) SWITH ONLY ( OIL) WITH AUXILIARY SWITH (NETZ) I > (LAST) SERIES TRIP WITH AUXILIARY SWITH (NETZ) (3) N AUX. SWITH TERMINALS N N A 2 3 4 N I > N B 2 3 4 3 TERMINALS.205 [5.2] SHUNT TRIP (LAST) (NETZ) (3) (LAST) DUAL OIL; SERIES TRIP URRENT OIL, SHUNT TRIP VOLTAGE OIL (NETZ).390[9.9] SHUNT SHUNT (NEBENSHLUSS) I > D E 0 VOLTAGE OIL I > U > H 0 4 TERMINALS (LAST) RELAY TRIP RELAY (RELAIS) (NETZ) (3) (LAST) VOLTAGE OIL DUAL OIL; SERIES TRIP URRENT OIL, RELAY TRIP VOLTAGE OIL VOLTAGE (NETZ) OIL.780[9.8] RELAY I > F G 0 VOLTAGE OIL I > U > K 0.390[9.9] RELAY RELAY (RELAIS) (LAST) (LAST) VOLTAGE OIL.370[9.40]REF SEE TABLE B DEPTH BEHIND PANEL.032[.8] (NETZ).560[39.62] TABLE B TERMINAL DESRIPTION MAIN SHUNT, RELAY & DUAL OIL TAB (Q..) SREW E TAB (Q..) SREW #8-32 W/UPTURNED LUGS DEPTH BEHIND PANEL 2.370 [60.20] 2.402 [6.0] 2.577 [65.46] 2.734 [69.44].640[4.66] REF.220[5.59] (LAST) * AUX. SWITH.093 TAB (Q..).0 TAB (Q..) SOLDER E 2.465 [62.6] 2.559 [65.00] 2.340 [59.44] AUXILIARY SWITH TERMINAL DETAIL TERMINAL DIMENSIONAL DETAIL & RATING.344[8.74].[6.35].25[3.8].360[9.4].392[9.96].392[9.96].050 DIA [Ø.27].0[2.79] TAB (Q..).093[2.36].39[3.53].058 DIA[Ø.47] TAB (Q..) SOLDER E.[6.35].069[.75] DIA TAB (Q..) <= 30 AMP.375[9.53] UPTURN LUG #8-32 <= 30 AMP #0-32 <= 30 AMP M5 <= 30 AMP.375[9.53] BUS #8-32 <= 30 AMP #0-32 <= 50 AMP * AVAILABLE ON SERIES TRIP AND SWITH ONLY IRUITS. WHEN ALLED FOR ON MULTI-POLE UNITS, ONLY ONE AUX. SWITH IS RMALLY SUPPLIED, AS VIEWED IN MULTI-POLE IDENTIFIATION SHEME. SEE PAGE TES All dimensions are in inches [millimeters]. 2 Tolerance ±.05 [.38] unless otherwise specified. 3 Schematic shown represents current trip circuit. arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 43

A-Series Rocker Form and Fit Drawings INDIATE "ON" INDIATE "OFF" & SINGLE OLOR (INDIATE "OFF" SHOWN) #6-32 [M3] THREAD X.95 [4.95] DEEP 2 PLS.945 [24.00].420 [0.67].20 [3.05].755 [9.8] MAX BREAKER WIDTH OPTIONAL "ROKER GUARD".660 [42.6] 2.56 [54.76].245 [3.62].560 [39.62] 2.000 [50.80].745 [8.92] MAX ROKER ADAPTER BRAKET WIDTH A.208 [5.27].370 [9.40] REF.640 [4.66] 2.370 [60.20] TAB E 2.402 [6.0] SREW E.432 [0.97] TAB (Q..) E TERMINALS IN SERIES TRIP IRUIT ONFIGURATION SHOWN. FOR OTHER ONFIGURATIONS SEE IRUIT & TERMINAL DIAGRAMS AF.545 [3.62].432 [0.97] ENTER- OF ROKER, & PANEL UT-OUT.945 [24.00] OPTIONAL "PUSH-TO RESET" ATUATOR.245 [3.62] ON I 2.309 [59.65] OFF.272 [5.82] A2.220 [5.59] OPTIONAL "ROKER GUARD" SHOWN IN DASHED S PANEL UT-OUT DETAIL +.00 [±.25] -.000 [±.00].750 [9.05] AF2.055 x.205 SLOTTED HOLE (ROKER OFF ATUATION).203 [.8] ROKER SHROUDED ON "OFF" POSITION SIDE, SHOWN IN DASHED S.00 [25.65] ±.005 [±.3].660 [42.2].260 [32.00].660 [42.6].660 [42.6].55 [38.48] MAX.750 [9.05].200 [5.08] ±.005 [±.3].56 DIA [Ø3.96] 2 HOLES A3 AF3 2.265 [57.53] MAX P() P(2) P(3) (SEE TE 2) REAR VIEW OF INDIATE "ON" SERIES TRIP W/ AUX SWITH IRUIT ONFIGURATION. P() P(2) P(3) (SEE TE 2) TES Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON. 2 For pole orientation with horizontal legend rotate front view clockwise 90. 3 All dimensions are in inches [millimeters]. 4 Tolerance ±.00 [.25] unless otherwise specified. 44 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

A-Series P Terminal Diagrams.375 [9.53].586 [4.88].25 [3.7].665 [6.90] (3 PL).22 [5.6].558 [39.57] N.632 [6.05] (2 PL) ±.003 ±.076.030 [.76] P.. TERMINALS.295 [7.49].295 [7.49] ±.005 ±.3.060 DIA [Ø.52] 5 HOLES.494 [2.55].528 [38.8] ±.005 ±.3. [2.54] P.. FOOT PRINT TES Drawing illustrates A-Series Rocker with VDE ertification. P Terminals also available on A-Series Handle; consult factory. 2 All dimensions are in inches [millimeters]. 3 Tolerance ±.00 [.25] unless otherwise specified. arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 45

A-Series Handle Ordering Scheme PROD ODE A POLES 2 One 2 Two 3 Three 4 Four 5 Five 6 Six AUXILIARY SWITH 4 0 w/o Aux Switch 0.093 Q.. Term. 2 0.0 Q.. Term. 3 0.39 Solder Lug 4 0.093 Q.. Term. w/ Gold ontacts A A 3 B 0 ATUATOR A a Handle, one per pole B b Handle, one per multipole unit S c Mid-Trip Handle, one per pole T c Mid-Trip Handle, one per pole and alarm switch IRUIT A 3a B D 3b E 3b F 3b G 3b Switch Only (No oil) Series Trip (urrent) Series Trip (Voltage) Shunt Trip (urrent) Shunt Trip (Voltage) Relay Trip (urrent) Relay Trip (Voltage) TES a. Actuator Option A: (One-Six Poles) Handle tie pin, spacer(s) and retainers provided unassembled with multipole units. b. Actuator Option B: Handle location as viewed from front of panel: 2 pole - left pole; 3 pole - center pole; 4 pole - two handles at center poles; 5 pole - three handles at center poles; 6 pole - four handles at center poles. c. Handle moves to mid-position only upon electrical trip of circuit breaker. Actuator code S available with circuit codes B,, D, E, F, G, H & K. When actuator code T is specified, handle moves to mid-position and alarm switch activates only upon electrical trip of circuit breaker. Available with circuit codes B & only. 2. Standard multipole units have all poles identical except when specifying auxiliary switch - (see Note 4 and Fig. A) and/or mixed poles (consult factory). 3a. Switch Only available to 50 amps and six poles. For 30 amps and less, select urrent Rating ode 630. For 3-50 amps, select urrent Rating ode 650. 3b. Available with Terminal odes and 2 only. urrent type limited to 30 amps maximum. 4. Auxiliary switch available on Series Trip and Switch Only circuits to 30 amps. On multipole units, only one auxiliary switch is normally supplied, mounted in extreme right pole per Fig. A. 5a. Voltage coils not rated for continuous duty. Available only with Delay odes 0 and 20. 5b. Available to 50 amps max. and with ircuit odes B & D only. 6. For non-standard voltage or current ratings consult factory. 7. Series Trip current ratings of 35, 40 and 50 amps limited to a maximum of two poles. 8. Screw terminals are recommended on current ratings greater than 20 amps. Ratings 35, 40 and 50 amps available with Terminal ode 5 only. 9. Standard actuator colors are black and white. 0. Terminal barriers available, consult factory. 46 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

A-Series Handle S E L E T O N E OIL RATING 6 URRENT OIL AMPERES 20 0. 225 0. 0.500 275 0.750 40.000 425 2.500 450 5.000 475 7.500 60 0.000 65 5.000 620 20.000 625 25.000 630 30.000 635 7 35.000 640 7 40.000 650 7 50.000 VOLTAGE OIL 5a RATED MIN. TRIP VOLTS VOLTS A06 6 D 5 D A2 2 D 0 D K20 20 A 65 A ATUATOR OLOR 9 OLOR LEGEND B White ON-OFF (Black) D Black ON-OFF (White) G Red ON-OFF (White) N Yellow ON-OFF (Black) AGENY APPROVAL A W/O Approval B UL Recognized UL Recognized; SA ertified I UL Recognized Standard 077; UL Recognized Standard 500 Ignition protected; SA ertified 0 450 B FREQUENY AND DELAY 03 D, 50/60Hz When Delay is not applicable, i.e. Switch Only circuit option. 0 5a D Instantaneous D Ultra Short 2 D Short 4 D Medium 6 D Long 20 5a 50/60Hz Instantaneous 2 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 32 D, 50/60Hz Short 34 D, 50/60Hz Medium 36 D, 50/60Hz Long 42 5b 50/60Hz Short (Hi-Inrush) 44 5b 50/60Hz Medium (Hi-Inrush) 46 5b 50/60Hz Long (Hi-Inrush) 52 5b D Short (Hi-Inrush) 54 5b D Medium (Hi-Inrush) 56 5b D Long (Hi-Inrush) 8, 0 TERMINAL Push-On; 0. Tab (Q..) 2 Screw 8-32 w/upturned Lugs 3 Screw 8-32 (Bus Type) 4 Screw 0-32 w/upturned Lugs 5 Screw 0-32 (Bus Type) PRINTED IRUIT BOARD TERMINAL AVAILABLE; ONSULT FATORY MOUNTING Threaded insert 6-32 x 0.95 inches deep 2/pole 2 0 Threaded insert ISO M3 x 5mm deep 2/pole 5 Front panel Snap-in, 0.75 inch wide bezel/pole 7 0 Front panel Snap-in, 0.96 inch wide bezel on single pole units..05 inch bezel overhang/side on multi-pole units arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 47

A-Series Rocker Ordering Scheme PROD ODE A POLES 2 One 2 Two 3 Three AUXILIARY SWITH 4 0 w/o Aux Switch 0.093 Q.. Term. 2 0.0 Q.. Term. 3 0.39 Solder Lug 4 0.093 Q.. Term. w/ Gold ontacts Figure B ROKER STYLE DESRIPTIONS INDIATE "ON" ODE "" INDIATE "OFF" ODE "F" SINGLE OLOR ODE "J" VERTIAL STYLE HORIZONTAL STYLE ODE "D" ODE "G" ODE "K" SHADED AREAS IDENTIFY INDIATE OLOR LOATION A F B 0 TES. For description of actuator styles and legend positions refer to Figure B. Push to Reset actuators have Off portion of rocker shrouded. 2. Multipole units have one rocker per unit. Rocker location as viewed from front of panel as follows: 2 pole - left pole; 3 pole - center pole. Standard multipole units have all poles identical except when specifying auxiliary switch (See note 4 and Fig A) and/or mixed poles. 3a. Switch Only available to 50 amps and three poles. For 30 amps and less, select urrent Rating ode 630. For 3-50 amps, select urrent Rating ode 650. 3b. Available with Terminal odes and 2 only. urrent type limited to 30 amps maximum. 4. Auxiliary switch available on Series Trip and Switch Only circuits to 30 amps. On multipole units, only one auxiliary switch is normally supplied, mounted in extreme right pole per Fig. A. 5a. Voltage coils can be used on Series, Shunt, or Relay trip Dump circuit applications. These voltage coils are rated for intermittent pulse duty and are only available with delay codes 0 & 20. 5b. Available to 50A (UL/SA), 30A (VDE) and ircuit odes B & D only. 6. For other voltage or current ratings consult factory. 7. Screw terminals are recommended by arlingswitch and are required by VDE on current ratings greater than 20 amps. 8. Ratings 35, 40 & 50 amps available with Terminal ode 5 only. 9a. olor shown is Visi and Legend color with remainder of rocker black. 9b. DUAL=ON-OFF/I-O legend. 9c. Legend on Push-To-Reset Bezel/Shroud is white when single color rocker type is ordered. When visi-rocker types are ordered, the legend matches the visi-color. 9d. Rockerguard available with actuator codes:,d,f,g,j, and K. 9e. Push-To-Reset available with actuator codes: N,O,R and U. 0. onsult factory for VDE certified 2495 constructions.. Terminal Barrier available; consult factory. ATUATOR VISI-ROKER 0 Indicate ON, Vertical Legends D Indicate ON, Horizontal Legends F Indicate OFF, Vertical legends G Indicate OFF, Horizontal Legends SINGLE OLOR ROKER 0 J Vertical Legends K Horizontal Legends PUSH TO RESET (VISI-ROKER) 9E N Indicate Off, Vertical Legends O Indicate Off, Horizontal Legends SINGLE OLOR ROKER 9E R Vertical Legends U Horizontal Legends IRUIT A 3a Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D 3b Shunt Trip (urrent) E 3b Shunt Trip (Voltage) F 3b Relay Trip (urrent) G 3b Relay Trip (Voltage) Dual coil construction available - consult factory. 48 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277

A-Series Rocker S E L E T O N E OIL RATING 6 URRENT OIL AMPERES 20 0. 225 0. 0.500 275 0.750 40.000 425 2.500 450 5.000 475 7.500 60 0.000 65 5.000 620 20.000 625 7 25.000 630 7 30.000 635 7,8 35.000 640 7,8 40.000 650 7,8 50.000 VOLTAGE OIL 5a VOLTS MIN. TRIP VOLTS A06 6 D 5 D A2 2 D 0 D K20 20 A 65 A L40 240 A 30 A SINGLE OLOR ROKER ROKER OLOR LEGEND 9b Black I-O (White) D Black ON-OFF (White) 2 Black Dual (White) F Red I-O (White) G Red ON-OFF (White) 3 Red Dual (White) H Green I-O (White) J Green ON-OFF (White) 4 Green Dual (White) K Blue I-O (White) L Blue ON-OFF (White) 5 Blue Dual (White) M Yellow I-O (Black) N Yellow ON-OFF (Black) 6 Yellow Dual (Black) P Gray I-O (Black) Q Gray ON-OFF (Black) 7 Gray Dual (Black) R Orange I-O (Black) S Orange ON-OFF (Black) 8 Orange Dual (Black) ATUATOR OLOR SELET ONE VISI-ROKER VISI OLOR 9a LEGEND 9b A White I-O (White) B White ON-OFF (White) White Dual (White) F Red I-O (Red) G Red ON-OFF (Red) 3 Red Dual (Red) H Green I-O (Green) J Green ON-OFF (Green) 4 Green Dual (Green) AGENY APPROVAL A W/O Approval B UL Recognized UL Recognized; SA ertified D 0 UL Recognized; SA & VDE ertified I UL 500 Ignition Protected; UL Recognized; SA ertified 24 630 2 3 D FREQUENY AND DELAY 03 D, 50/60Hz When Delay is not applicable, i.e. Switch Only circuit option. 0 5a D Instantaneous D Ultra Short 2 D Short 4 D Medium 6 D Long 20 5a 50/60Hz Instantaneous 2 50/60Hz Ultra Short 22 50/60Hz Short 24 50/60Hz Medium 26 50/60Hz Long 32 D, 50/60Hz Short 34 D, 50/60Hz Medium 36 D, 50/60Hz Long 42 5b 50/60Hz Short (Hi-Inrush) 44 5b 50/60Hz Medium (Hi-Inrush) 46 5b 50/60Hz Long (Hi-Inrush) 52 5b D Short (Hi-Inrush) 54 5b D Medium (Hi-Inrush) 56 5b D Long (Hi-Inrush) TERMINAL 7, Push-On 0. Tab (Q..) 2 Screw 8-32 w/ Upturned Lugs 3 Screw 8-32 (Bus Type) 4 Screw 0-32 w/ Upturned Lugs 5 8 Screw 0-32 (Bus Type) PRINTED IRUIT BOARD TERMINAL AVAILABLE; ONSULT FATORY MOUNTING STANDARD ROKER BEZEL Threaded insert 6-32x0.95 in. deep 2 Threaded insert ISO M3x5mm deep ROKERGUARD BEZEL 9D or PUSH-TO-RESET BEZEL 9,9E 3 Threaded insert 6-32 x0.95 in. deep 4 Threaded insert ISO M3x5mm deep arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277 49

A -Series Rocker Accessories Panel Hole Plug AESSORY ODE 8 ircuit Breaker Accessory POLES One ATUATOR E & MOUNTING STYLE Actuator Mounting 2 Rocker 6-32 Threaded Insert 3 Rocker ISO M3 Threaded Insert PANEL HOLE PLUG FINISH 2 Gloss 8 A 2 2 2 PRODUT SERIES A A-Series Rocker AESSORY E Panel Hole Plug PANEL HOLE PLUG OLOR 2 Black.660 [42.6] # 6-32 [M3] THREAD X.95 [4.95] DEEP 2 PLS ±.003 [±.076].245 [3.62].80 [4.57].20 [3.05] ±.003 [±.076].370 [9.40] +.000 [+.00] -.004 [-.0].744 [8.90] PANEL UT-OUT DETAIL +.00 [+.25] -.000 [-.00].750 [9.05] ±.005 [±.3].260 [32.00].660 [42.6] TES All dimensions are in inches [millimeters]. 2 Tolerance ±.00 [.25] unless otherwise specified..200 [5.08] ±.005 [±.3].56 DIA [Ø3.96] 2 HOLES 50 arlingswitch,inc. (860) 793-928 arlingswitch, LTD. Int + 44 392-364422 arlingswitch Asia-Pacific, LTD. Int + 852-2737-2277